Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC NO 9 6 203 1 G2 DURGA BHAVANI NAGAR CHAMPAPET HYDERABAD 500059 | HYDERABAD | TELANGANA | 500059 | ₹37.2 L Quoted ₹38.4 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹40.4 L+₹1.9 L (4.98%)Rejected-Finance | ₹40.4 L+₹1.9 L (4.98%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹44.8 L+₹6.3 L (16.5%)Rejected-Finance | ₹44.8 L+₹6.3 L (16.5%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹48.2 L+₹9.8 L (25.4%)Rejected-Finance 94A APR COLONY BILHARI JABALPUR MP | JABALPUR | MADHYA PRADESH | 482020 | ₹48.2 L+₹9.8 L (25.4%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹49.8 L+₹11.3 L (29.4%)Rejected-Finance | ₹49.8 L+₹11.3 L (29.4%) | L5 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | S.S.ENGINEERING CORPORATION L13 | CHITRA ENGINEERING CORPORATION L12 | BHAGYARAM ENTERPRISES L2 | SUN LIGHT HOUSE L9 | M/S DIVIJA BUILDERS L7 | SHILPA CONSTRUCTION COMPANY L3 | UNITY ENGINEERING TRADERS L11 | M/s ANUSHA ENTERPRISES L6 | Ravi Enterprises L4 | M/S GDR CONSTRUCTIONS L1 | vvcenterprises L5 | M.R.ENTERPRISES L10 | M/S PAVANI ENTERPRISES L8 | Bismi Engineering L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5m deep for foundation of poles/stay/cable etc including getting out in any type of soil complete all as specified and directed by Engr-in-Charge. | 290 | CUM | 404 ₹1,17,160 | 401 ₹1,16,290 | 300 ₹87,000 | 388 ₹1,12,520 | 405 ₹1,17,450 | 375 ₹1,08,750 | 400 ₹1,16,000 | 400 ₹1,16,000 | 365 ₹1,05,850 | 250 ₹72,500 Lowest | 300 ₹87,000 | 388 ₹1,12,520 | 385 ₹1,11,650 | 400 ₹1,16,000 |
| 2.00 | Excavation in trenches beyond 1.5 m wide and n.exc. 3 m deep for foundation of poles/stay etc including getting out in any type of soil complete all as specified and directed by Engr-in-Charge. | 1.9 | CUM | 565 ₹1,073.5 | 563 ₹1,069.7 | 350 ₹665 | 559 ₹1,062.1 | 505 ₹959.5 | 465 ₹883.5 | 562 ₹1,067.8 | 500 ₹950 | 50 ₹95 Lowest | 300 ₹570 | 550 ₹1,045 | 555 ₹1,054.5 | 555 ₹1,054.5 | 500 ₹950 |
| 3.00 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in depth. | 130.05 | CUM | 149 ₹19,377.45 | 147 ₹19,117.35 | 100 ₹13,005 | 141 ₹18,337.05 | 89 ₹11,574.45 | 141 ₹18,337.05 | 146 ₹18,987.3 | 75 ₹9,753.75 | 120 ₹15,606 | 50 ₹6,502.5 Lowest | 50 ₹6,502.5 Lowest | 139 ₹18,076.95 | 141 ₹18,337.05 | 75 ₹9,753.75 |
| 4.00 | Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point. | 155.5 | CUM | 35 ₹5,442.5 Lowest | 332 ₹51,626 | 150 ₹23,325 | 319 ₹49,604.5 | 160 ₹24,880 | 285 ₹44,317.5 | 331 ₹51,470.5 | 150 ₹23,325 | 300 ₹46,650 | 100 ₹15,550 | 50 ₹7,775 | 322 ₹50,071 | 321 ₹49,915.5 | 150 ₹23,325 |
| 5.00 | M&L Sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying complete all as specified.
Note : Only punned thickness shall be measured. | 94.8 | CUM | 2,157 ₹2,04,483.6 | 2,153 ₹2,04,104.4 | 700 ₹66,360 Lowest | 2,112 ₹2,00,217.6 | 1,200 ₹1,13,760 | 1,860 ₹1,76,328 | 2,152 ₹2,04,009.6 | 1,150 ₹1,09,020 | 1,700 ₹1,61,160 | 900 ₹85,320 | 800 ₹75,840 | 2,060 ₹1,95,288 | 2,045 ₹1,93,866 | 1,150 ₹1,09,020 |
| 6.00 | M&L Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all as specified. | 10.5 | Per 1000 Nos | 5,132 ₹53,886 | 5,128 ₹53,844 | 5,100 ₹53,550 | 5,090 ₹53,445 | 11,000 ₹1,15,500 | 4,830 ₹50,715 Lowest | 5,126 ₹53,823 | 10,000 ₹1,05,000 | 5,100 ₹53,550 | 9,000 ₹94,500 | 9,000 ₹94,500 | 5,200 ₹54,600 | 4,900 ₹51,450 | 10,000 ₹1,05,000 |
| 7.00 | M&L Plain cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified. | 0.22 | CUM | 5,631 ₹1,238.82 | 5,627 ₹1,237.94 | 5,000 ₹1,100 Lowest | 5,612 ₹1,234.64 | 7,600 ₹1,672 | 6,000 ₹1,320 | 5,625 ₹1,237.5 | 7,500 ₹1,650 | 5,300 ₹1,166 | 6,000 ₹1,320 | 6,000 ₹1,320 | 5,460 ₹1,201.2 | 5,595 ₹1,230.9 | 7,500 ₹1,650 |
| 8.00 | M&L Plain cement concrete (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in coping including necessary formwork to poles etc complete all as specified. | 1.9 | CUM | 6,162 ₹11,707.8 | 6,158 ₹11,700.2 | 5,100 ₹9,690 | 6,051 ₹11,496.9 | 6,200 ₹11,780 | 6,000 ₹11,400 | 6,156 ₹11,696.4 | 6,000 ₹11,400 | 5,500 ₹10,450 | 5,000 ₹9,500 Lowest | 5,500 ₹10,450 | 6,080 ₹11,552 | 6,100 ₹11,590 | 6,000 ₹11,400 |
| 9.00 | S & F in repair of Pin type insulators porcelain, vitreous, white/ brown or green insulators including one galvanized MS spindle, two galvanized iron washer, GI nut of size 100 mm height and 65mm dia 1100 volts grade incl dismantling of old unsv complete all as specified . | 12 | Each | 218 ₹2,616 | 214 ₹2,568 | 150 ₹1,800 Lowest | 201 ₹2,412 | 250 ₹3,000 | 186 ₹2,232 | 213 ₹2,556 | 200 ₹2,400 | 175 ₹2,100 | 150 ₹1,800 Lowest | 220 ₹2,640 | 208 ₹2,496 | 205 ₹2,460 | 200 ₹2,400 |
| 10.00 | S & F in repair of Shackle type insulators, porcelain, vitreous white/ brown or green including galvanised MS strips, bolt, nuts and washer of size 75mm height and 90mm dia, size of strap section 31x3mm and dia of 12 mm for working pressure 1100 volts grade incl dismantling of old unsv complete all as specified | 12 | Each | 215 ₹2,580 | 211 ₹2,532 | 150 ₹1,800 Lowest | 209 ₹2,508 | 320 ₹3,840 | 186 ₹2,232 | 210 ₹2,520 | 300 ₹3,600 | 175 ₹2,100 | 160 ₹1,920 | 330 ₹3,960 | 200 ₹2,400 | 206 ₹2,472 | 300 ₹3,600 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
18 Jun 2025, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
REPAIR / MAINTENANCE OF LT /OH LINES, UG CABLE AND LT SWITCH GEARS INSTALLED AT DRDL /ASL AREA UNDER GE(I) RND KANCHANBAGH HYDERABAD
2025_MES_709827_1
8961
Open Tender
Civil Works
Item Rate
270 days
GE I R and D Kanchanbagh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹96,000
Yes
30 Aug 2025
23 May 2025
20 Jun 2025
23 May 2025
18 Jun 2025
6 Jun 2025
Amount
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5m deep for foundation of poles/stay/cable etc including getting out in any type of soil complete all as specified and directed by Engr-in-Charge.
Excavation in trenches beyond 1.5 m wide and n.exc. 3 m deep for foundation of poles/stay etc including getting out in any type of soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in depth.
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point.
M&L Sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying complete all as specified. Note : Only punned thickness shall be measured.
M&L Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all as specified.
M&L Plain cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified.
M&L Plain cement concrete (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in coping including necessary formwork to poles etc complete all as specified.
S & F in repair of Pin type insulators porcelain, vitreous, white/ brown or green insulators including one galvanized MS spindle, two galvanized iron washer, GI nut of size 100 mm height and 65mm dia 1100 volts grade incl dismantling of old unsv complete all as specified .
S & F in repair of Shackle type insulators, porcelain, vitreous white/ brown or green including galvanised MS strips, bolt, nuts and washer of size 75mm height and 90mm dia, size of strap section 31x3mm and dia of 12 mm for working pressure 1100 volts grade incl dismantling of old unsv complete all as specified
M&L in repair of earth wire/guard cradle hexagonal/rectangular fabricated with 4mm dia galvanized mild steel, binding wire including dismantling of old unsv complete all as specified and directed by Engr-in- Charge.
M&L in repair of Aluminium conductors, reinforced (ACSR) conductor of any size for OH lines including stretching, binding wire ,jumpers, line taps etc including dismantling of old unsv complete all as specified.
Supply and fixing in repairs of damaged steel tubular swaged pole with cast iron base plate finial tapper plug, bolts nuts and screws and specified type 410-SP-31 ( 9 Mtr long) in truly vertical position 1.5 m length of pole above ground level shall be painted with two coats of synthetic enamel paint in strips of 30 cm width, black and yellow alternatively and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts complete all as specified laying 40mm GI pipe light grade for cable protection and fixing to existing pole with flat iron clamp 25x3mm including nuts bolts and washers etc complete including taking out old unserviceable pole complete all as directed by Engr-in-Charge
M & L in repair of Cross arms, bracings, supports, clamps and back plate fabricated from structural steel section including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shapes size as indicated or directed and inclusive of one primer coat, and one under coat and one finished coat of aluminium paint incl dismantling of old unsv complete all as specified.
S & F in repair heavy duty PVC flat two core cable weather proof with aluminium solid conductor,1100 Volts grade 16 Sqmm 2 core for service wire pole or passing through pipe including all accessory etc complete all as specified.
S & F in repair heavy duty PVC flat two core cable weather proof with aluminium solid conductor, 1100 Volts grade 10 Sqmm 2 core for service wire pole or passing through pipe including all accessory etc complete all as specified.
S & F in repair heavy duty PVC flat two core cable weather proof with aluminium solid conductor, 1100 Volts grade 06 Sqmm 2 core for service wire pole or passing through pipe including all accessory etc complete.
Supply & fixing in repairs MCCB 4 pole, 415 volts adjustable type, 160 Amps with breaking capacity 35/36 KA complete all as specified.
Supply & fixing in repairs MCCB 4 pole, 415 volts adjustable type, 200 Amps with breaking capacity 25 KA complete all as specified.
Supply & fixing in repairs MCCB 4 pole, 415 volts adjustable type, 250 Amps with breaking capacity 25 KA complete all as specified.
Supply & fixing in repairs MCCB 4 pole, 415 volts adjustable type, 400 Amps with breaking capacity 25 KA complete all as specified.
Supply & fixing in repairs MCCB 3 pole, 415 volts adjustable type, 160 Amps with breaking capacity 35KA complete all as specified.
Supply & fixing in repairs MCCB 3 pole, 415 volts adjustable type, 200 Amps with breaking capacity 50KA complete all as specified.
Supply & fixing in repairs MCCB 3 pole, 415 volts adjustable type, 350 Amps with breaking capacity 50KA complete all as specified.
Supply & fixing in repairs MCCB 4 pole, 415 volts adjustable type, 630 Amps with breaking capacity 50KA complete all as specified.
M&L in repair anti climbing device spike type fabricated out of MS bars round, square and flat in shape including nuts , bolts and washers and welding in two halves made to shape to suit the cross section of the pole all as specified and directed by Engr-In-Charge
Supply and replacement in repairs of danger notice board 1.6mm thick M.S sheet, vitreous enameled white with letters, figures and conventional skull and bone in signal red colour and fixed with M.S clamps, bolts and nuts of approved size for LT 20x15cm size. by replacing the unserviceable one.
S&F in repair 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 35 Sqmm nominal cross section 3.5 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed. Note- Earth work and protection work shall be measured and paid for separately under respective items of BOQ.
All as per item No. 28 above but cross sectional area 25 Sqmm 4 core complete all as specified and directed.
All as per item No. 28 above but cross sectional area 70 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 28 above but cross sectional area 95 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 28 above but cross sectional area 120 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 28 above but cross sectional area 185 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 28 above but cross sectional area 240 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 28 above but cross sectional area 300 Sqmm 3.5 core complete all as specified and directed.
Supply & fixing in replacement of cable end heat shrink type jointing kit 1100 Volts for indoor/outdoor termination with jointing material and accessories suitable for 35 to 50 Sqmm 3.5/4.0 core XLPE/PVC armoured aluminium conductor cable complete all as specified and directed by EIC.
Supply & fixing in replacement of cable end heat shrink type jointing kit 1100 Volts for indoor/outdoor termination with jointing material and accessories suitable for 70 Sqmm to 95 Sqmm 3.5/4 core XLPE/PVC armoured aluminium conductor cable complete all as specified and directed by EIC.
Supply & fixing in replacement of cable end heat shrink type jointing kit 1100 Volts for indoor/outdoor termination with jointing material and accessories suitable for 120 Sqmm to 185 Sqmm 3.5/4.0 core XLPE/PVC armoured aluminium conductor cable complete all as specified and directed by EIC.
Supply & fixing in replacement of cable end heat shrink type jointing kit 1100 Volts for indoor/outdoor termination with jointing material and accessories suitable for 225 Sqmm to 300 Sqmm 3.5/4.0 core XLPE/PVC armoured aluminium conductor cable complete all as specified and directed by EIC.
S&F in repair cable route indicator made out of 50x6 mm angle iron 60 mm long embedded in PCC block of suitable size with moulded letter HT cable or LT cable suitable inscribed on cast iron circular plate 8 mm thick 100 mm dia complete including PCC (1:3:6) type C-2 (using 40mm graded aggregate block of 150x150x150 mm size) all as specified and directed by Engineer - in - Charge
Supply and laying in repair GI tubing light grade 40 mm dia with all fitting laid in trenches or fixed on wall along pole complete for protection of electric cable/strip complete all as specified by Engineer-in-Charge.
M&L for ACB 4 pole ,415 V , with thermal Magnetic release (manual fixed type) of capacity 630 Amp including dismantling complete all as speicified and as directed
M&L for ACB 4 pole ,415 V , with thermal Magnetic release (manual fixed type) of capacity 800Amp complete all as speicified and as directed
M&L for ACB 4 pole ,415 V , with thermal Magnetic release (manual fixed type) of capacity 1000 Amp complete all as speicified and as directed
M&L for ACB 4 pole ,415 V , with thermal Magnetic release (Manual drawout type) of capacity 630 Amp complete all as speicified and as directed
M&L for ACB 4 pole ,415 V , with thermal Magnetic release (Manual draw type) of capacity 800 Amp complete all as speicified and as directed
M&L for ACB 4 pole ,415 V , with thermal Magnetic release (Manual draw type) of capacity 1000 Amp complete all as speicified and as directed
Supply and fixing in repairs "ON LOAD" type change over switch front handle operated, on existing LT/AMF panels, of capacity 1000 Amps and suitable for three phase, 415 V, 50Hz AC as per existing make suitable to be fitted with the existing panels or any other make as mentioned in CA including taking down old one and making all connection including renewal of cable lugs/terminals if required complete all as specified and directed.
All as per item No. 51 above but of capacity 630 Amps
All as per item No. 51 above but of capacity 320 Amps
Supply and fixing in repairs "OFF LOAD" type change over switch front handle operated, on existing LT/AMF panels, of capacity 320 Amps and suitable for three phase, 415 V, 50Hz AC as per existing make suitable to be fitted with the existing panels or any other make as mentioned in CA including taking down old one and making all connection including renewal of cable lugs/terminals if required complete all as specified and directed.
All as per item No. 54 above but of capacity 200 Amps
Supply & fixing in replacement of junction box of size 250x200x150 mm made of MS Sheet 1.6mm thick, front door openable with fixing screw painting with two coats of synthetic enamel powder coated paint over a coat of red oxide including alumn bus bar 4 Nos of size 25x3mm mounted on epoxy based post insulators and drilled holes for connection including 01 Nos MCB SPN 20 Amps , 1 Nos MCBs 06 amps incl magnetic lock system all as required and fixed to poles using MS strip of size 32x6mm and nuts & bolts of required size all as required at site or directed by Engr-in-charge.
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing shall be re-done by the contractor at his own.
BHAGYARAM ENTERPRISES (BID ID -3321617)
SHILPA CONSTRUCTION COMPANY (BID ID -3321925)
Ravi Enterprises (BID ID -3327254)
vvcenterprises (BID ID -3321596)
M/s ANUSHA ENTERPRISES (BID ID -3322525)
Bismi Engineering (BID ID -3322305)
M/S DIVIJA BUILDERS (BID ID -3321837)
M/S PAVANI ENTERPRISES (BID ID -3321557)
SUN LIGHT HOUSE (BID ID -3321654)
M.R.ENTERPRISES (BID ID -3321527)
UNITY ENGINEERING TRADERS (BID ID -3322274)
CHITRA ENGINEERING CORPORATION (BID ID -3321513)
S.S.ENGINEERING CORPORATION (BID ID -3321475)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .