Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC 06 KHASRA NUMBER 56 KIRAN NAGAR BASNI JODHPUR JODHPUR RAJASTHAN 342001 UDYAM RJ 22 0002214 | JODHPUR | RAJASTHAN | 342001 | ₹34.8 L Quoted ₹35.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹37.6 L+₹2.2 L (6.15%)Rejected-Finance FLAT NO 1004 BUILDING NO L 11 KEDAR HOUSING SOCIETY 10TH FLOOR SECTOR NO 21 TALOJA PHASE 2 PANVEL RAIGAD NAVI MUMBAI 410208 | NAVI MUMBAI | RAIGAD | MAHARASHTRA | 410208 | ₹37.6 L+₹2.2 L (6.15%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹42.7 L+₹7.3 L (20.7%)Rejected-Finance | ₹42.7 L+₹7.3 L (20.7%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹42.8 L+₹7.4 L (21.0%)Rejected-Finance C 40 BHAGAT SINGH NAGAR BHIND ROAD GWALIOR MP 474005 | NA | NA | 474005 | ₹42.8 L+₹7.4 L (21.0%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹43.7 L+₹8.3 L (23.4%)Rejected-Finance | ₹43.7 L+₹8.3 L (23.4%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
15 Jul 2023, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer - 345001
COMPLETION OF INCOMPLETE WORK OF REPAIR TO EARTHING AND LIGHTNING CONDUCTOR IN MD ACCN/OTM ACCN UNDER THE JURISDICTION OF GE (A) JAISALMER
2023_MES_604089_1
8316/23-24/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹99,000
Yes
5 Apr 2024
17 Jun 2023
17 Jul 2023
17 Jun 2023
15 Jul 2023
1 Jul 2023
Amount
Taking out carefully copper/GI earthing complete including GI pipe and removing materials for taking credit and making good disturbed surface complete all as specified and directed by Engineer-in-charge.
Taking down carefully copper/GI earthing Strip Copper/Aluminium /GI wire complete including and removing materials for taking credit and making good disturbed surface complete all as specified and directed by Engineer-in-charge.
Taking down the existing unservicable earthing Test point terminal block as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-charge.
Taking down Air termination, single pointed copper rod 12 mm dia 300 mm long and making good disturbed surface of walls, floors etc complete all as specified and directed by Engineer-in-charge.
Taking down porcelain insulators as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to galvanized iron strip 32x6 mm as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point , earth dolly and earth chamber as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified and directed by Engineer-in-charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to 4.00 mm dia GI wire as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point , earth dolly and earth chamber as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified and directed by Engineer-in-charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with copper pipe of dia 40 mm bore and thickness of pipe not less than 1.80mm 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to copper strip 32x6mm as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point , earth dolly and earth chamber as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified and directed by Engineer-in-charge.
NOT FOR ITEM No. 6 to 8 [i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m. (vi) Test result for item No. 6 to 8 and all earthing testing result using ISI marked digital/ analoge earth tester of reputed make and test result shall be entered in a earth testing register and put to the Engr-in-Charge before completion of work. Earth tester to be provided by the contractor himself.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to DBs or any other indicated situation for loop earthing with galavanised iron strip of 25X4 mm size and suitable size porcelain insulator complete all as specified and directed by Engineer-in-charge.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit or fixed to DBs or any other indicated situation for loop earthing with 4.00 mm dia GI wire size complete all as specified and directed by Engineer-in-charge.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in pipe or fixed to DBs or any other indicated situation for loop earthing with copper strip of 32X6 mm size and suitable size porcelain insulator complete all as specified and directed by Engineer-in-charge.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in pipe or fixed to DBs or any other indicated situation for loop earthing with aluminium strip of 25x3 mm size and suitable size porcelain insulator complete all as specified and directed by Engineer-in-charge.
M&L Air termination, single pointed copper rod 12 mm dia 300 mm long with 200x200x100 mm pcc block base fixing complete all as specified and directed by Engineer-in-charge.
M & L Earthing Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hex. head screw.Material and labour for testing/termination point made out of 32 x 6 mm copper strip of length 150 mm duly housed in suitable MS box insulators etc for linking the down conductor and the earth terminals of the lightening arrester system complete all as specified and directed by Engineer-in-charge.
Supply and fix insulators made out of porcelain for fixing the lightening roof conductor and the down conductor complete all as specified and directed by Engineer-in-charge.
M & L earth chamber for GI strip/ GI wire/ Copper strip earthing as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle and funnel for 20 mm dia GI watering pipe etc complete all as specified and directed by Engineer-in-charge.
M&L for GI Tubing light grade 40mm dia.for earthing strip protection complete all as specified and directed by Engineer-in-charge.
M&L for GI Tubing light grade 25mm dia.for cable protection complete all as specified and directed by Engineer-in-charge.
M/s ASPIRE ENGINEERING ENTERPRISES
M/S SHRI HARI CONSTRUCTION COMPANY
SHRI HARI CONSTRUCTION
AMBEY MAA CONSTRUCTION COMPANY
M/S PRASHANT BENIWAL
SHREE BHAGWATI ENTERPRISES
M/S SUMAN ENTERPRISES
M/s Yash Electrical and Maintenance
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .