Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAccepted-AOC MANEGAON CHAMPANAGAR KHAMARIA JABALPUR 482005 MP | JABALPUR | JABALPUR | MP | 482005 | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹3.7 L+₹23,828.36 (6.92%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 |
Tender Value
₹3.8 L
EMD Value
₹7,700
Closing Date
22 Jun 2022, 6:00 pmClosed
AGE (I) Naya Raipur
AGE (I) Naya Raipur C/o HQ COSA, Near International Cricket Stadium, Atal Nagar Raipur 492101
As per BOQ
2022_MES_525698_1
8400/324/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Naya Raipur
As per tender documents
8 documents required · 8 mandatory
₹300
AGE (I) Naya Raipur
₹7,700
15 Jul 2022
23 May 2022
24 Jun 2022
23 May 2022
22 Jun 2022
8 Jun 2022
Amount
Disconnecting and taking out DG set electric connection from both side incoming and out going electric and DG set supply of 30 KVA DG Set and serving the DG set with authotrised dealer/rep of dealer (Kirloskar) and make it complete with all respect as servicing , connecting ,testing etc with duly change of US Parts of DG Set same shall be measured paid separately and checking the battery terminals, apply necessary Vaseline on it and fresh connection complete all as specified and directed. Note: rate deemed to included the T&P used for this purpose bring by the contractor and If again any fault occur of same nature of repair during the defect liability period shall be rectified by the contractor at free of cost.
S&F in replacement of Fuel filter of DG set 30 KVA Silent type as per existing size specifications and make as approved by AGE (I) complete all as specified and directed.
S&F in replacement of coolant of DG set as per existing size specifications and make as approved by AGE (I) complete all as specified and directed.
S&F in replacement of Oil filter of DG set 30 KVA Silent type as per existing size specifications and make as approved by AGE (I) complete all as specified and directed.
S& filling/ changing in replacement of old US oil with of Kirloskar Engine Oil as per prescribed grade of Kirloskar complete all as specified and directed by engr-in-charge
Disconnecting and taking out DG set electric connection from both side incoming and out going electric and DG set supply of 62.5/63 KVA DG Set and serving the DG set with authorised dealer/rep of dealer (kirloskar) and make it complete with all respect as servicing , connecting ,testing etc with duly change of US Parts of DG Set same shall be measured and paid separately and checking the battery terminals, apply necessary Vaseline on it and fresh connection complete all as specified and directed Note: rate deemed to included the T&P used for this purpose bring by the contractor and If again any fault occur of same nature of repair during the defect liability period is rectified by the contractor at free of cost.
S&F in replacement of Fuel filter of DG set 62.5/63 KVA Silent type as per existing size specifications and make as approved by AGE (I) complete all as specified and directed.
S&F in replacement of Oil filter of DG set 62.5/63 KVA Silent type as per existing size specifications and make as approved by AGE (I) complete all as specified and directed.
S&F in replacement of battery terminal brass suitable for 12 volt 150 Ah battery of DG set as per existing size specifications and make as approved by AGE (I) complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out for laying of pipe cables etc,. and getting out complete all as specified and directed
Returning filling in, including spreading levelling, watering and well ramming in layers not exceeding 25cm thick with earth obtained from excavation complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. (Note :- Punned thickness will be measured)
Supply and laying bricks sub class 'B' laid dry abutting each other with gap between adjacent slab not exceeding 10mm over UG cable as in cable protection all as directed.
Taking out carefully existing unserviceable LT cable from pole, panels and trenches any size any capacity and removing connection from existing switch board/ over head line etc complete all as specified and directed by engr-in-charge
Supply/Laying or fixing or passing through pipe, jointing and testing 1100 volt grade XLPE insulated armoured heavy duty PVC insulated, PVC sheathed armoured electric cables 16 sqmm 4 core with aluminium stranded conductor, complete all as specified and as directed
All as per item No 16 here and above but size of cable 50 sqmm 3.5 core
All as per item No 16 here and above but size of cable 70 sqmm 3.5 core
Taking down and supply and laying galvanised iron pipe “Light Grade” 40mm bore dia in trenches, under floors, roads, along poles for protection of cables with all necessary fittings , including sealing ends complete all as specified and as directed.
All as per item No 19 here and above but pipe size 50mm bore dia
S& F for on load change over switch TPN 32 Amps capacity complete in sheet steel enclosure type FN (TPN) suitable for DIN fuse link and removing existing unserviceable one complete all as specified and directed by Engr-in-charge.
All as per item No 21 here and above but TPN 63 Amps.
All as per item No 21 here and above but TPN 100 Amps.
Taking down MCCB of any type and any capacity all as specified and directed by engr-in-charge.
Supply and fixing MCCBs 4 pole 415 volt adjustable type 250 amps, 36 KA three pole, incl necessary cable connection complete all as specified and directed by Engr-in-charge.
Supply and fixing MCCBs 4 pole 415 volt fixed type 25 to 100 amps, 16 KA three pole, incl necessary cable connection complete all as specified and directed by Engr-in-charge.
M & L for cable glands of size 16 sqmm to 50 sqmm complete all as specified and directed.
M & L for cable glands of size 70 sqmm to 95 sqmm complete all as specified and directed.
M & L for aluminium cable lugs off sizes 16 sqmm to 35 sqmm complete all as specified and directed by Engr-in-Charge.
M & L for aluminium cable lugs off sizes 50 sqmm to 95 sqmm complete all as specified and directed by Engr-in-Charge.
M & L for Earthing complete with galvanised steel earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground (earth pit not less than 2.25 metres deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected to GI strip 32 x 6 mm by means of GI bolts, nuts, check nuts and washers and earth strip protected by 40 mm dia GI pipe medium grade and connected to main distribution board/earthing test point all as shown on electrical plate No.3 of SSR Part I and complete all as specified including testing on completion. Notes: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix, type B1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe for earth lead upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II and also refer Plate No-03. Earth strip and protection pipe beyond 7.5m shall be measured and paid separately. Note :- Earthing will be redone if desired earth result not found during testing of the same at site.
Supply and fix aluminium strip 25 X 3.15 mm with PVC saddle and PVC gutties for keeping the gap with roof and wall complete all as specified and directed.
Supply and fix GI strip 32 x 6 mm with PVC saddle and PVC gutties for keeping the gap with roof and wall complete all as specified and directed.
Total contract sum shall be calculated after deduction of schedule of credit amount of Rs. 24,100.00.
FIRST SOLAR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .