| 2 | L2₹44.5 L+₹2.6 L (6.17%)Admitted-Fee/PreQual/Technical/Finance 34 KHALID BASHIR FIRST FLOOR SHOP NO 34 REGAL LANE MUNICIPAL COMPLEX SRINAGAR SRINAGAR SRINAGAR JAMMU KASHMIR 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | -30.99% | ₹44.5 L+₹2.6 L (6.17%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | L3₹56.8 L+₹14.8 L (35.4%)Admitted-Fee/PreQual/Technical/Finance | -12.00% | ₹56.8 L+₹14.8 L (35.4%) | L3 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹64.6 L
EMD Value
₹1.3 L
Closing Date
12 Sept 2026, 6:55 pmClosed
Executive Engineer
Shalimar
Balance Electrification Work by Way of LV Panels and Cabling etc and SITC of 30 KVA 3 phase Online UPS Compact Type with Lithium Backup for Lab Cum Lecture Block (A Block) Under (HADP/CAPEX) at Main Campus Shalimar, SKUAST-K.
2026_SKUST_323054_1
E-NIT-48 of 2026-27
Open Tender
Electrical Works
Percentage
20 days
main campus shalimar, SKUAST-K
Please refer Tender documents.
5 documents required · 5 mandatory
₹3,000
Assistant comptroller
₹1.3 L
17 Sept 2026
1 Sept 2026
14 Sept 2026
1 Sept 2026
12 Sept 2026
4 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Design ,supply ,installation, testing & commissioning of double door outdoor cubicle type IP66 panel suitable for 415v 3phase 4-wire 50Hz AC supply systeme fabricated, in compartmentized design from CRCA sheet of 2mm thickness including cleaning and finishing complete with 7 tank process for power coating in approved shade having 1000 amp capacity extensible type TPN aluminium Busbar of high conductivity connections, interconnections with adequate size copper wire, copper links, connectors and terminal blocks (on outgoing) etc alon with necessary nuts and bolts , clamps DMC Busbar support etc mounted on 40x40x6mm angle frame dully painted with for
Details as under
Panel Powder Coated 2.0mm 495 Kg Base Channel 100mm 85 Kg
Air Circuit Breaker 800A 4P 50kA MDO, Microprocessor release L&T 1 No.with Bus bar 1000 Amp
Digital V,A,F, PF Meter Class 1.0 L&T 2 No.CT 600/5 AE 2 Set
Outgoing
MCCB 250A 4P 50kA L&T 3 No with shunt trip coils
MCCB 125A 4P 36kA L&T 1 No with shunt trip coils
MCCB 400A 4P 50kA L&T 2 No. with shunt trip coils
Spreader Terminals For DN2/DN1, MCCB 3 Set
Spreader Terminals For all
Accessories like nut bolts, locks,
insulators, control wire etc 1 Set | 1 | Job | 6,49,000 | ₹6,49,000 |
| 2 | POWER PANEL
Fabrication, supply, installation, testing & commissioning of double door indoor type compartmentalized feeder pillar having front area not less than depth 45 Cm (NS) made out of 2mm thick CRCA sheet with tappered roof having separate cable and bus bar alley, 1 door arrangement i/c locking arrangement, having 1000 Amp four pole aluminium bus bar of full length with base frame made out of 50mmx50mmx6mm (thick) angle iron having 80cm legs for erection in ground with construction of cement concrete suitable foundation size complete with connections and interconnections with copper conductor PVC insulated cables/ insulated aluminium busbar strips of appropriate size and terminal blocks (on outgoing) including supplying & fixing following switchgears & accessories there in, powder coating, labelling, earthing etc. complete as required. Providing and fixing following accessories in existing cubical panel board i/c making connection etc. as reqd.
INCOMER
Thermal Magnetic Based MCCB 400 Amps FP Icu=Ics=100% with Breaking Capacity 50 KA (01 Nos)
Indicating Lamps RYB (1 Set)
Voltmeter-0-500 Volts(1 Nos)
Ammeter(0-150 A)(1 Nos)
Selector Switch (2 Nos)
Current Transformer 100/5 A 10 VA Burden, Class-1(1 sets)
Aluminium Busbar 1000 Amps FP E-91 E Grade Electrolytic Aluminium
DP MCB 32A(03Nos) | 2 | Job | 2,95,000 | ₹5,90,000 |
| 2.01 | OUTGOINGS
Thermal Magnetic Based MCCB 125 Amps FP Icu=Ics=100% with Breaking Capacity 36 KA (08 Nos)
Load Bearing Members to be made out of 2.0 mm CRCA Sheet.
Partitions to be made out of 1.6 mm CRCA Sheet
Gland Plates to be 3.0 mm Thick.
Cable Alley spacing | - | - | - | - |
| 3 | LIGHTING PANEL
Fabrication, supply, installation, testing & commissioning of double door indoor type compartmentalized feeder pillar having front area not less than depth 45 Cm (NS) made out of 2mm thick CRCA sheet with tappered roof having separate cable and bus bar alley, 1 door arrangement i/c locking arrangement, having 1000 Amp four pole aluminium bus bar of full length with base frame made out of 50mmx50mmx6mm (thick) angle iron having 80cm legs for erection in ground with construction of cement concrete suitable foundation size complete with connections and interconnections with copper conductor PVC insulated cables/ insulated aluminium busbar strips of appropriate size and terminal blocks (on outgoing) including supplying & fixing following switchgears & accessories there in, powder coating, labelling, earthing etc. complete as required. Providing and fixing following accessories in existing cubical panel board i/c making connection etc. as reqd.
INCOMER
Thermal Magnetic Based MCCB 250 Amps FP Icu=Ics=100% with Breaking Capacity 50 KA (01 Nos) with shunt trip coils
Indicating Lamps RYB (1 Set)
Voltmeter-0-500 Volts(1 Nos)
Ammeter(0-150 A)(1 Nos)
Selector Switch (2 Nos)
Current Transformer 100/5 A 10 VA Burden, Class-1(1 sets)
Aluminium Busbar 600 Amps FP E-91 E Grade Electrolytic Aluminium
DP MCB 32A(03Nos) | 2 | Job | 2,52,000 | ₹5,04,000 |
| 3.01 | OUTGOINGS
Thermal Magnetic Based MCB 125 Amps FP Icu=Ics=100% with Breaking Capacity 25 KA (04 Nos)
Load Bearing Members to be made out of 2.0 mm CRCA Sheet.
Partitions to be made out of 1.6 mm CRCA Sheet
Gland Plates to be 3.0 mm Thick.
Cable Alley spacing
Bypass changeover 3 P- 100A = 4 No | - | - | - | - |
| 4 | INSIDE AC/VRV PANEL
Fabrication, supply, installation, testing & commissioning of double door indoor type compartmentalized feeder pillar having front area not less than depth 45 Cm (NS) made out of 2mm thick CRCA sheet with tappered roof having separate cable and bus bar alley, 1 door arrangement i/c locking arrangement, having 1000 Amp four pole aluminium bus bar of full length with base frame made out of 50mmx50mmx6mm (thick) angle iron having 80cm legs for erection in ground with construction of cement concrete suitable foundation size complete with connections and interconnections with copper conductor PVC insulated cables/ insulated aluminium busbar strips of appropriate size and terminal blocks (on outgoing) including supplying & fixing following switchgears & accessories there in, powder coating, labelling, earthing etc. complete as required. Providing and fixing following accessories in existing cubical panel board i/c making connection etc. as reqd.
INCOMER
Thermal Magnetic Based MCCB 160 Amps FP Icu=Ics=100% with Breaking Capacity 36 KA (01 Nos) with shunt trip coils
Indicating Lamps RYB (1 Set)
Voltmeter-0-500 Volts(1 Nos)
Ammeter(0-150 A)(1 Nos)
Selector Switch (2 Nos)
Current Transformer 100/5 A 10 VA Burden, Class-1(1 sets)
Aluminium Busbar 600 Amps FP E-91 E Grade Electrolytic Aluminium
DP MCB 32A(03Nos) | 2 | Job | 96,500 | ₹1,93,000 |
| 4.01 | OUTGOINGS
Thermal Magnetic Based MCB 100 Amps FP Icu=Ics=100% with Breaking Capacity 16 KA (04 Nos) with RCCB as outgoing for all MCBS
Load Bearing Members to be made out of 2.0 mm CRCA Sheet.
Partitions to be made out of 1.6 mm CRCA Sheet
Gland Plates to be 3.0 mm Thick.
Cable Alley spacing | - | - | - | - |
| 5 | S/L of Cable 3.5 core XLPE A2XWY A2XFY 1.1 KV 300 Sq mm Al armoured with termination works etc | 110 | Mtr | 4,000 | ₹4,40,000 |
| 6 | S/L of Cable 3.5 core XLPE A2XWY A2XFY 1.1 KV 185 Sq mm Al armoured with termination works etc | 250 | Mtr | 2,500 | ₹6,25,000 |
| 7 | S/L of Cable 3.5 core XLPE A2XWY A2XFY 1.1 KV 120 Sq mm Al armoured with termination works etc | 315 | Mtr | 1,720 | ₹5,41,800 |
stage.html
html • 0.02 MB
finance_1086128.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.05 MB
BOQ_1086128.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .