| 1 | L1₹16.5 LAccepted-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹18.0 L+₹97,624 (5.75%)Rejected-AOC | L2 | Rejected-AOC L2 BIDDER | |
| 3 | L3₹18.3 L+₹1.3 L (7.70%)Rejected-AOC B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-AOC L3 BIDDER | |
| 4 | L4₹20.6 L+₹3.6 L (21.4%)Rejected-AOC | L4 | Rejected-AOC L4 BIDDER |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
5 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Amla
GE AF Amla, Betul Dist 460553 (MP)
Repair/Maintenance of lightening protection system at AF Station Amla.
2020_MES_362912_2
8379/E8 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF Amla
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹40,000
Yes
14 Oct 2020
14 Aug 2020
7 Sept 2020
14 Aug 2020
5 Sept 2020
21 Aug 2020
60 days
Amount
Laying and Jointing PVC Pipe. Heading
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for taking out pipe / cables/ earthing and earth lead etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ soil complete all as specified and directed.
All as per item No 1 here in before but depth exceeding 1.5m and not exceeding 3 metres and getting out in soft/ soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/ soil complete all as specified and directed.
Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Supply & install of steel tubular swaged poles complete with cast iron base plate 6mm thick of size 450mm x 450mm finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) pole made out of ERW MS tubing confirming to IS 2713 / IS 1161 Part II including drilling of holes of required size and nos for fixing of cross arms bracing support/ taking out of cables etc, and painting with one coat of red oxide primer and two coat of aluminium paint for exposed surface and two coat of black bituminious paint for the portion embeded in concerete after taking down old one complete all as specified and as directed. Note: Excavation of earthwork, PCC concrete bed etc will be measured & paid in respective item of works)
Material & Labour for cement concrete Type C2 1:3:6 (40 mm graded aggregate) as in foundations of pole etc complete all as specified as directed.
Material & Labour for cement concrete Type C1 1:3:6 (20 mm graded aggregate) as in coping of poles and mass concrete including all necessary formwork complete all as specified & as directed.
Supply and fix ready made type heavy duty PVC chamber box IP 65 having minimum dimension 98mm x 98 x 52mm with provision of earthing strip entry glands including taking down old one complete all as specified and directed Make: Hensel / Neptune / Syntex
Material & labour from Cross arms, bracing, clamps,and and back plates fabricated from structural steel sections including nuts, bolts,washers, welding , bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium silver paint including removel of extisting unsv one complete all as specified and as directed.
Material & labour for aluminium conductor, steel reinforced fixed on poles as suspended conductor after taking down old one complete all as specified and directed.
Supply & fixing porcelain, vitreous, white, brown or green insulator shackle type 50mm height, 65mm dia with 9mm dia bolts washers and nuts including galvanised and mild steel straps, after taking down old one including complete all as specified and directed.
Supply & fixing stay assembly for angle iron / pole of lightening conductor comprising of 7/3.15 mm galvanised mild steel stranded stay wire of required length fixed to angle iron / pole with and including flat iron clamp of 50 x 6mm size, bolts nuts, washers stay rod of 16mm dia, 2.15 metres long, stay bow, with nuts bolts, washers, galvanised steel plate 230 x 230 x 6mm and 2 No thimble, including necessary PCC 1:2:4 type C2 (20 mm graded stone aggregate) for foundation complete all as specified and as directed. Note :- Rates for excavation/returning filling/removal etc. is deemed to be included in unit rate quoted by the contractor.
Taking down old defective copper conductor multi stranded of any size from roof / angle iron and making good to the disturbed surfaces to match the existing surface complete all as specified & directed.
Taking down old defective conductor strips of any type/description from wall/ roof and making good to the disturbed surfaces to match the existing surface complete all as specified & directed.
Taking down old defective stay alongwith all accessories and making good to the disturbed surfaces to match the existing surface complete all as specified & directed.
Supply & fixing multi stranded copper conductor of size 7 strands 8 SWG each strand on poles/ angle iron complete all as specified and as directed.
Rejuvenate the existing earthing (GI/copper plate earthig) with provision of new layers of charcoal and salt all as specified in electrical plate No 3 of SSR Part-I, including cleaning of existing GI/Copper earth plate, conductors etc, connecting with new bolts, nuts and washers including replacement of watering pipe, funnel with wire mesh, earth lead and protection pipe including necessary testing on complete all as specified and directed. Note : - (i) Excavation will be measured & paid under item No 1 to 4. (ii) Watering pipe, funnel with wire mesh will be measured & paid under item No. 21, 22 & 23
Material & labour for earthing complete with galvanized steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. Note :- (a) Rates for excavation and earthwork in soft/loose soil and 40 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. (b) On testing after completion if less than 5 Ohm earth resistance is not obtained the earthling will be redone at no extra cost with the department.
Material & labour for earthing complete using copper plate 60×60cm ×3.15mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to 20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion. NOTE :- (a) Rates for Excavation and earthwork in any type of soil/strata, testing on completion, Copper strip 20x3 mm and 40 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. (b)On testing, after completion, if the earth resistance < 5 ohms is not obtained, earthing will be rejuvenated at no extra cost till the desired earth resistance is obtained.
Material & labour for maintenance free grounding solution set earthing comprising of high tensile low carbon steel rod of 3 meter length & 17.2 mm dia with 250micron (Average) molecularly bonded copper on the outer surface along with back-fill compound strictly be a carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr. back-fill compound should be electronically conductive (Like in metals) and should not depend on moisture for conduction. The earth electrode should finally be housed in a heavy duty readymade type PVC chamber with future access cover. Back-fill compound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. Make: JEF Technology /Excel Fibro tech / Trupower solution Note :- (a) Rates for excavation and earthwork in soft/loose soil, testing on completion, copper strip 20x3 mm and 40 mm dia protection pipe up to 7.5 mtr from earth plate is deemed to be included in rate quoted. (b) On testing, after completion, if the earth resistance < 5 ohms is not obtained, earthing will be rejuvenated without any extra to the department. (c) Test certificate from the OEM has to be produced by the contractor for the material used in earthing.
Supply only funnel made out of aluminium sheet in conical shape, dia of the funnel should be similar to existing funnel complete all as specified and as diirected. [Note: Material to be incorporated against item No.17]
Supply only light grade GI pipe 20 mm dia for watering in earthing Pit complete all as specified and directed. [Note: Material to be incorporated against item No.17]
Supply only light grade GI pipe 40 mm dia for protection of earthing lead complete all as specified and directed. [Note: Material to be incorporated against item No.17]
Material & labour for "Test Point Terminal Block" made of gun metal or phosphorus bronze of having size 75 X 75 X 25 mm drilled and screwed by providing 3 nos 8 mm dia 25 mm long hexazonal head screw and connected to Copper/ Aluminium / GI strips complete housed in a PVC junction box after taking down old one complete all as specified and directed. Note : The test points wil be properly fixed on epoxy insulators. Cost of epoxy insulators are inclusive of unit rate quoted by the contractor.
Supply and fix ready made outdoor type heavy duty polymer earth pit chamber box of inner size 450x450x300 mm with provision of earthing strip/ GI pipe entry glands and cover after demolishing / taking down old brick Masonry/PCC chamber complete all as specified and directed. Make: Allied power solution/True power earthings pvt ltd/S G Power products Pvt Ltd
Material & labour Copper strip of size 100 X 50 X 5 mm drilled and screwed including 3 nos 8 mm dia screw and washers connected to Copper/ Aluminium / GI strips after taking down old one complete all as specified and directed.
Supply & fixing Air termination single pointed aluminium rod not less than 12mm dia and 300mm long end threaded all as specified and as directed.
Supply & fixing Air termination single pointed Copper rod not less than 12mm dia and 300mm long end threaded after taking down old one complete all as specified and directed.
Supply & fixing Post insulator epoxy LV type suitable for aluminium/ GI strip 25 x 4 mm lightening conductor fixed on wall/roof/pole including screw after taking down old one complete all as specified and directed.
Supply & fixing Post insulator cetrally threaded epoxy LV type suitable for holding threaded aluminium/ copper AT rod 12 mm dia fixed on stand post including screw after taking down old one complete all as specified and directed.
Material & labour for fixing aluminium strip of size 25 x 4 mm fixed to wall with aluminium saddles and screws / buried in ground/ drawn in conduit/ fixed to poles or any other indicated situation for loop earthing including connected upto test terminal point complete all as specified and directed. Note : - Insulators/conduit/pipe shall be measured and paid separately under appropriate items here in after
Material & labour for fixing Copper strip of size 20 x 3 mm fixed to wall with aluminium saddles and screws / buried in ground/ drawn in conduit/ fixed to poles or any other indicated situation for loop earthing including connected upto test terminal point complete all as specified and directed. Note : - Insulators/conduit shall be measured and paid separately under appropriate items here in after
Supply and lay in trenches / fixed to walls 32 mm bore class 3 grade PVC pipe for protection of earth strip complete fixing with suitable clamps at 0.5 meter apart spancomplete all as specified and directed. Make Finolex, Polycab ( NOTE :- Rates for flat iron clamps, bolts, nuts and washer etc are deemed to be included in rate quoted.
Material & labour for fixing Galvanised iron strip of size 25x4 mm fixed to wall with Galvanised iron saddles and screws / buried in ground/ drawn in conduit/ fixed to poles or any other indicated situation for loop earthing including connected upto test terminal point complete all as specified and directed. Note : - Insulators/conduit/pipe shall be measured and paid separately under respective iteam of works
Taking down old unserviceable roof earth continuity conductor/ static discharge strips of any type and description/ size from wall/roof/floor and refixing the same with insulator epoxy coated at 0.5 metre span including brass nut , bolts, washers etc. and making good to the disturbed surfaces to match the existing complete all as specified and directed at site. Note : - Insulators shall be measured and paid separately.
Note:- (i) The amount against Schedule of Credit on Page No. 25 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contarct Sum for Acceptance.
M/s Shree Ganesh Traders
Shri Sai Enterprises
M/s Vinod Yadav
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .