Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹2.1 CrAccepted-AOC | ₹2.1 Cr Quoted ₹2.2 Cr | 1st | Accepted-AOC Being Lowest |
| 2 | 2nd₹2.3 Cr+₹9.9 L (4.54%)Rejected-Finance CHHATABAD HABIB MENSION KATRASGARH DHANBAD DHANBAD 828113 JHARKHAND INDIA | DHANBAD | DHANBAD | JHARKHAND | 828113 | ₹2.3 Cr+₹9.9 L (4.54%) | 2nd | Rejected-Finance Being not lowest |
| 3 | 3rd₹2.3 Cr+₹10.6 L (4.86%)Rejected-Finance | ₹2.3 Cr+₹10.6 L (4.86%) | 3rd | Rejected-Finance Being not lowest |
| 4 | 4th₹2.3 Cr+₹12.6 L (5.75%)Rejected-Finance D 89 SHASTRI NAGAR MEERUT UTTAR PRADESH PIN 250004 | MEERUT | UTTAR PRADESH | 250004 | ₹2.3 Cr+₹12.6 L (5.75%) | 4th | Rejected-Finance Being not lowest |
| 5 | 5th₹2.5 Cr+₹27.5 L (12.6%)Rejected-Finance KALU BASS SHRI DUNGARGARH BIKANER RAJASTHAN 331803 | BIKANER | BIKANER | RAJASTHAN | 331803 | ₹2.5 Cr+₹27.5 L (12.6%) | 5th | Rejected-Finance Being not lowest |
Tender Value
₹1.8 Cr
EMD Value
₹2.5 L
Closing Date
25 Jun 2021, 6:00 pmClosed
CHIEF ENGINEER R AND D DELHI
Chief Engineer Rand D Delhi Timarpur New Delhi 110054
COMPLETION OF INCOMPLETE WORK FOR PROVISION OF ACCOMMODATION FOR DSC PLATOON AT ADRDE AGRA
2021_MES_424744_3
CE R and D/DLI-25/AGRA/2020-2021
Open Tender
Civil Works
Lump-sum
300 days
AGRA
As per Tender
8 documents required · 8 mandatory
₹1,000
Yes
GE I R and D Delhi
₹2.5 L
Yes
5 Jul 2021
3 Jun 2021
28 Jun 2021
3 Jun 2021
25 Jun 2021
13 Jun 2021
3 Jun 2021 - 13 Jun 2021
Amount
Lump sum price worked out by the Contractor for balance work pertaining to “EXACAVATION AND EARTH WORK” as listed in Schedule ‘A’ section II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION WORK ” as listed in Schedule ‘A’ Section III
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Section IV
Lump sum price worked out by the Contractor for “ PCC PATH ” as listed in Schedule ‘A’ Section V
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL WORK ” as listed in Schedule ‘A’ Section VI
Lump sum price worked out by the Contractor for balance work pertaining to “AREA DRAINAGE ” as listed in Schedule ‘A’ Section VII
Lump sum price worked out by the Contractor for balance work pertaining to “ Compound Wall and Steel Gate WORK” as listed in Schedule ‘A’ Section VIII
Lump sum price worked out by the Contractor for “ EXTERNAL WATER SUPPLY WORK ” as listed in Schedule ‘A’ Section IX
Lump sum price worked out by the Contractor for “ EXTERAL ELECTRIFICATION WORK” as listed in Schedule ‘A’ Section X
Lump sum price worked out by the Contractor for ' HOT WATER SUPPLY WORK ” as listed in Schedule ‘A’ Section XI
Lump sum price worked out by the Contractor for 'REFRIGERATION AND AIR CONDITIONING WORK ” as listed in Schedule ‘A’ Section XII
Provisional sum price worked out by the Contractor for 'BADMINTON AND VOLLEY BALL COURT ” to be priced on SSR 2010
BUILDING WORK SCH 'A' SEC-I
Completion of balance work and rectification of defects for construction of building for single living accommodation for one JCO single storey including scoter shed including all fittings and fixtures complete all as specified and shown on drawings. Present work done in percentage completed by defaulting contractor is 66.85%. For details refer to annexure-4
Completion of balance work and rectification of defects for Construction of building for SM barrack for 4 Havs & 50 ORs double storey including staircase with all fittings & fixtures complete all as specified & shown on drgs. Present work done in percentage completed by defaulting contractor is 48.45%. For details refer to annexure-4
Completion of balance work and rectification of defects for Construction of building for guard room single storey including all fittings & fixtures complete all as specified and shown on drawings Present work done in percentage completed by defaulting contractor is 66.95%. For details refer to annexure-4
Completion of balance work and rectification of defects for Construction of building for cook house and dining hall single storey including all fittings & fixtures complete all as specified and shown on drawings. Present work done in percentage completed by defaulting contractor is 53.30%. For details refer to annexure-4
Completion of balance work and rectification of defects for Construction of building for storage accommodation single storey including all fittings & fixtures complete all as specified and shown on drawings. Present work done in percentage completed by defaulting contractor is 65.90%. For details refer to annexure-4
Completion of balance work and rectification of defects for Construction of building for tradesmen shop single storey including all fittings & fixtures complete all as specified and shown on drawings. Present work done in percentage completed by defaulting contractor is 71.20%. For details refer to annexure-4
Completion of balance work and rectification of defects for Construction of building for parking shed single storey including all fittings & fixtures complete all as specified and shown on drawings. Present work done in percentage completed by defaulting contractor is 83.30%. For details refer to annexure-4
Completion of balance work and rectification of defects for Construction of office building single storey including all fittings and fixtures complete all as specified and shown on drawings. Present work done in percentage completed by defaulting contractor is 63.60%. For details refer to annexure-4
Completion of balance work and rectification of defects for Construction of pump house building single storey including all fittings & fixtures complete all as specified and shown on drawings. Present work done in percentage completed by defaulting contractor is 65.75%. For details refer to annexure-4
Construction of underground sump 3 meter dia and 3 meter depth complete all as specified and shown on drawings.
SCHEDULE `A' Section - XIII MISC ITEMS as under is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
S&F wall mounted decorative CFL fitting un breakable made up of poly carbonate suitable for 11 watt retrofit CFL including 15 Watt CFL with acrylic cover complete all as specified and as directed.
S&F exhaust fan 300 mm sweep with louvers complete, connecting up with provision of flexible cable PVC twisted twin core copper conductor of size 23/.0076 from ceiling rose or connector to fan complete all as specified and as directed.
S&F MCB SPN 32 Amps, 240 V AC complete all as specified and as directed.
S&F MCB SP 6 to 32 Amps, 240 V AC complete all as specified and as directed.
S&F PVC blanking plate of suitable size for incorporating in the DB's complete all as specified including testing complete.
Supply and fixing 2 core 2.5 sqmm stranded aluminium conductor PVC insulated unsheathed cable to connect from junction box to direct light fiting through inside of pole including testing and commissioning complete all as specified and as directed.
Material and labour for earthing complete with galvanised steel earth plate electrode size 600mm x 600mm x 6.0mm thick, buried directly in ground (earth pit not less than 2.25 mtr below ground levels) with top edge of the earth plate not less than 1.50 mtr below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavatoin and earth work and from work GI pipe 20 mm bore medium grade for watering and GI pipe 40 mm bore light grade for protection of GI strip, charcoal dust, common salt, PCC M-10 (Normal mix) type C-1 chamber and frame of suitable size made out of MS angle iron 40x40x3 mm and RCC M-15 (Normal mix) type B-1 using 20 mm graded stone aggregates as in cover 40 mm thick reinforced with 6 mm dia MS round bras @ 75 mm centre spacing both ways with MS handle 12 mm dia for lifting, PGI funnel and wire mesh complete all as shown in elctrical plate No 3 of SSR Part-I (2009) and connected to and including test point and testing on completoin complete all as specified and as directed.
Supply and fixing security light fitting with reflector with half glass half cover accessories 150 watt HPSV complete with acrylic cover copper ballast, with lamp 150 watt necessary prewired including provision of bracket made oaut of GI pipe light grade 40 mm bore, 1.2 m long, fixed to wall with clamps complete fitting all as specified and directed by engineer in charge.
Supply , laying jointing and connecting 2 pair 0.61 mm dia tinned copper conductor PVC insulated and PVC sheathed screened telephone cable conforming to DOT specificatoin (ISI marked) including provision of lugs, gland jointing material etc in and including 20 mm dia PVC concealed conduit heavy duty for telephone point complete all as specified and as directed.
Supply and fixing RJ-11 telephone socket outlet in and including mild steel box 75x75 mm with thick laminated sheet cover complete all as specified and as directed.
Supply and laying of underground XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (Heavy duty ) with aluminium conductor 11000 volts grade earthed of cross sectional area 95 sqmm 3 core complete all as specified and as directed. (Note :- HT cable drum of length as per site requirement shall be brought to avoid cable joint in between the route of cable).
Supply install test and commissioning of LT feeder pillar box (KIOSK) type floor mounted of size 1.8m x 0.80m x 0.45m made out of 3.15 mm thick mild steel black sheet and angle iron frame 40x40x5 mm size front rear door openable of totally enclosed and vermin proof duly painted with spray painting with two coat of 1st quality syenthtic enamel paint over one coat of red oxide zinc chromate primer complete with 04 Nos alumunium strip busbar of size 40x6 mm mounted on porcealain insulator including internal wiring using suitable size copper conductor cable with the following accessories ;- (a) MCCB 4 pole 200 A 440 volt, 36 KA - 01 No (Incomer) (b) MCCB 3 pole 160 A 440 volt, 36 KA - 02 No (c) MCCB 3 pole 63 A 440 volt, 16 KA - 02 No (d) Power contactor ML-3 suitable for three phase 415 volt - 01 Nos (e) Programable time switch single phase 240 volt- 01 (f) Digital voltmeter flush type 0-500 volt (g) Digital ammeter flush type 0-600 A - 01 Nos (h) Indication lamp with neon lamp - 03 Nos (j) Cut out fuse 5 Amps for metering equipment as required
M&L for earthing complete with galvanised steel earth plate electrode size 600mm x 600mm x 6.0mm thick, buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.50 mtr below normal ground level surrounded from all sides by mixtures of charcoal and common salt and electrode connected to and including galvanised iron strip 32 x 6 mm earth lead by means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20 mm dia bore for watering funnel with wire mesh, CI cover with frame PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No.3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
Supply and fix outdoor feeder pillar box size 75cm x 60cm x 30cm factory made fabricated cubical 3 phase, 4 wire made out of MS sheet 1.6mm thick mounted on suitable angle iron frame grouted in PCC block n.exc 0.6 mtr height from ground level consisting of weather proof double hinged door alongwith locking arrangement finished with 2 coat of spray painting with super enameled paint over a coat of red oxide primer comprising of the following accessories :- (a) Bus bar chamber 200 Amps comprising of 04 Nos aluminium bus bar fixed on suitable post insulator.
Drilling of trial bore well 300mm dia at approved site for 200 mm dia MS casing pipe for various depth as shown below including all works pertaining to boring complete in all respects and all as specified in any type of strata from 0 to 30 meter below Ground Level.
Description complete all as per item no 39 here in before but Depth exc. 30 m but n.exc 60 meter below ground level.
Description complete all as per item no 39here in before but Depth exc. 60 m but n.exc 110 meter below ground level.
Supply and fix for 200 mm dia (bore) ERW MS pipe 8 mm thick as per IS-4270-1992 and lowering into bore hole in the perfectly vertical position upto required depth below ground level and welding the same including cutting , threading complete all as required and specified.
Description complete all as per item No.42 here-in-before above, but 200 mm dia (Bore) ERW MS slotted pipe 8 mm thick having slots of 03mm wide and 75 mm long each as per IS-4270-1992 all as specified and directed .
Supply and fix of screwed MS bail plug 200mm dia 6 mm thick of 01 mt. long with MS rod 25mm dia size welded to it and 300 mm from bottom bail hook all as specified and directed.
Supply and fixing mild steel cap for top of 300mm bore well with locking arrangement including two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply and packing with pea gravel of size 05 mm to 10 mm of approved quality free from dust and other foreign material packed gravels all around casing pipe/slotted pipe in bore well complete all as specified and directed .
Development of bore well by using of compressed air (rig compressor) for minimum Hrs to give optimum yeild and submit test report along with strata chart and strata sample complete as per IS-11189-1985. Yeild test shall be carried out in last two hours of development by using 'V' notch complete all as specified and directed.
Carrying out Chemical and bacteriological test of water sample to ensure portability of water complete all as specified and as directed.
Supply and fixing submersible water proof cable with stranded copper conductor 3 core PVC insulated & PVC sheathed cable of size 6 Sqmm 1100 volts grade including cable lugs complete all as specified and directed.
M&L of MS work as in holding pipe clamps 02 Nos fabricated out of flat 100x10mm made to shape drilling , fixing with and including 08 Nos of 16 mm dia botl, nuts washer etc complete all as specified and as directed .
Supply installation , lowering, testing, commissioning submersible pump set multistage with submersible motor 3 Phase , 415V , 2800 rpm not less than 10HP complete with column pipe 70 mtr head and discharge as recommended and according to yield of well as directed for 300mm bore well and 200 mm casing complete all as specfied and directed.
S&F of pressure gauge for indicating of water flow of pressure from 0 to 10 Kg/Sqmm complete all as specfied and directed.
M&L for providing PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in platform of bore well, Indluding all necessary form work complete all as specified.
M&L for providing 100mm thick hard core of gauge 63mm of broken stone boulder complete all as specified.
Supply and installed and testing complete of electronic liquied chlorination dozing having capacity @ 1.5 to 10 LPH and frequency upto 400 SPM alongwith single phase 230 volts , 50Hz AC power consume 30 watt alongwith suction and discharge tubing of size 6 mm , suction filler with NRV & 200 liters PVC tank camplete all as specified and as directed.
Supply installation testing and commissioing of horizontal centrifugal pumping sets electric operated multistage having minimum discharge capacity of 330 LPM at 60M, 1500 RPM, 3 phase, 415 volt, head with steel shaft , CI impeller, CI casing totally enclosed fan cooled , with suitable capacity squirrel cage induciton motor 10HP for suitable operation on 3 phase , 50 Hz, 415 V, including making PCC foundation of suitable size. The pump set will be fixed on common base channel frame supported by anti viberation pad including necessay electric connection with multi stranded copper conductor cable of suitable size from starter to motor and making inlet/outlet pipe line connection using nuts, bolts, rubbers gaskets etc and other required materials for smooth funciton of pump sets complete all as specified and as directed.
supply , installatation , testing and commissioning of diesel driven generating set to give an out put of 20 KVA, 415V AC supply 3 phase, 50 HZ, 4 wire radiator mounted on common base plate complete with fuel tank, vibration damper and other accessories with fuel tank viberation damper and other accessories with acoustic enclouser as per latest CPCB morms and AMF panel include foundations work complete all as specified and directed, interalla comprising of following . (A) DIESELDRAIVENENGINE :- Developing a net output suitable matched to give a net rated output of minimum 28 HP/suitable to drive 20KVA alternator, at 0.8 power factor 415 volts. The engine should be capable of delivering the required output at 1500 RPM, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified. (i) Fly wheel to suit flexible coupling and fly wheel housing, (ii) Air cleaner complete as per manufacturer specification, (iii) Fuel injection pump, (iv) Flexible coupling with guard, nuts and bolts., (v) Fuel filter with mounting., (vi) Oil filter with mounting. (vii) Starter motor as per manufacture's design. viii) Exhaust, silencer industrial type with exhaust pipe suitable length. (ix) Batteries 12 volts 1x180 AH maintenance free batteries with copper lead, terminals etc. (x) Instrument panel complete with microprocessor based controller comprising shut down valve indication, LCD hour counter indication, RPM indication , LED lamps for fail to start, over speed /under speed . Low lub oil pressure, high engine coolant temperature. gaugae. (xi) Dynamo/alternator suitable rating. (B) ALTERNATOR . The above engine will be coupled through flexible coupling on an indigenous alternator mounted on a strong steel fabricated common base frame suitable for mountingin an acoustic enclousre. The alternator will be 3 phase 50 HZ 1500 RPM self reglating self existing type and have class H insulation of stator and rotor windings and generate 20 KVA output at .8 Power factor 4 wire 415 volts AC supply under NTP condition with a provision of 10% overload for 1 hour in every 12 hrs running. The alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltabe regulator. (C) CONTROL PANEL :- S&F AMF (Automatic on mains failure) control panel CPRI approved outdoor ype KIOSK ' water, dust and vermin proof and fabricated out of 3.15 mm thick CRCA sheet and 50mm x 50mm x 6mm angle iron powder coated suitable for 415 volts 3 phase 50 Hz AC supply with and incl the following :-
(i) MCCB of suitable capacity (ii) Necessary relays, times and power contractors of suitable rating/capacity for auto ON-OFF the DG set and changeover of the load in case of power failure. (iii) Digital mulfifunctional meter for phase wise reading of amps, voltage KWH and frequency -01 (iv) Internal wriring with single core solid copper conductor cable of appropriae gauge incl mumbering ferrules and control fuses. (v) Earthing terminals 02 Nos (vi) Auto/Manual start switch to by pass auto start. (vii) Battery charging system suitable for charging for charging the battery provided with the DG Set incl boost/stickle switch and system, DC voltmeter digital type (viii) Angle iron 50mm x50mm x 6mm size legs 04 Nos 650 mm guouted in PCC 1:2:4 type B-1 of size 300mm x 300mm x 500mm with 450 nn griybd clearance. (D) FUEL TANK :- One No built in sheet metal steel tank of 14 SWG thickness mounted inside the acoustic encloser and of adequate capacity to hold diesel for 12 hrs countinuous running with inlet and outlet connection including the following :- (i) Level indicator with float and gauge. (ii) Fuel piping for fuel supply to engine and over flow to tank (iii) Fuel strainer (E) ACOUSTIC ENCLOSURE :- Enclousre be designed for reducing the sound level up to 75+/ 5db (average) as per IS 8528 part 10 and as per approved CPCB morms. the acoustic encloure must consist of the following :- (i) CRCA sheet with body 16 SWG thick. (ii) Base frame fabricated from ISMS Channel (iii) Insulated rock wool fire retardant/non-igniting noice reduction type and properly clamped provided on all doors, roof and sides. (iv) Special designed SS doors locks and door hinges.. (v) Thermostate switch to shut off the engine in case the temperature inside the accoustic enclousre increases beyond 70 degree Celsus. (vi) Glass windows in acoustic enclousre suitably located to read/check the various meters and controls.
SUB TOTAL OF SCH 'A' SEC- I & XIII
national engineering workshop
SHRANGI RISHI CONSTRUCTION
MOHAN LAL GUPTA
M/s R L PAREEK
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .