Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.2 L+₹77,303 (3.98%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹24.0 L+₹4.6 L (23.6%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹24.1 L+₹4.6 L (23.9%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹25.9 L+₹6.5 L (33.4%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
27 Jun 2023, 6:00 pmClosed
GE NORTH DELHI CANTT-10
GE NORTH DELHI CANTT-10
REPAIR MAINT OF INTERNAL ELECTRICATION WORK SERVICE INCL REPLACEMENT OF UNSV LIGHT FITTINGS FIXTURS WIRING SUBMAIN WIRING DISTRIBUTION BOARD MCCBs MCBs BLDG SECURITY LIGHTS ETC OF OTM ACCN CENTRAL ORDANANCE DEPOT COD AREA CICG FOL DEPOT AND VARIOUS O
2023_MES_599916_1
GE/NORTH-47/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE NORTH DELHI CANTT-10
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE NORTH DELHI CANTT-10
₹90,000
Yes
16 Aug 2023
31 May 2023
28 Jun 2023
31 May 2023
27 Jun 2023
14 Jun 2023
Amount
Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing all as specified and directed.
M&L for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for One light / bell / buzzer point controlled by one, one way switch 06 Amps.
All as per the description of srl item No 02 here-in-before but one fan point controlled by one, one way switch 06 Amps.
All as per the description of srl item No 02 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch complete all as specified and as directed. .
All as per the description of srl item No 02 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch complete all as specified and as directed.
All as per the description of srl item No 02 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F switch piano flush type, 06 Amps, single pole, one way, 230 volts complete all as specified and as directed.
S&F in repair of switch piano type 2 way 5/6 Amp, 230 Volt, flush button single pole two way complete all as specified and directed by Engineer -in-Charge.
S&F in repair switch piano flush type, 16 Amps, single pole, one way, 230 volts with switch frame complete all as specified and as directed.
S&F in repair socket outlet 2 in 1, 5 pin, 06 Amps, flush type, 230 volts with socket frame complete all as specified and as directed.
S&F in repair socket outlet 2 in 1, 3 pin, 06 Amps and 3 pin, 16 Amps, flush type, 230 volts with socket frame complete all as specified and as directed.
S&F in repair ding dong bell, AC, 230 volts, single pole complete all as specified and as directed.
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S&F in repair ceiling rose, 6 Amps, 230 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete all as specified and as directed.
Supply and fix in rapair lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 9W LED bulb complete all as specified and as directed.
S&F in repair 10/12W LED TL fitting (2 fit) attractive wall mounted type suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete
S&F in repair on wall / ceiling LED batten lighting fixture 20 watts LED 5700K (4'), with extruded aluminium heat sink, integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete
S&F in reapair decorative wall mounting light SS finish fixture with extruded glass difuser suitable for up to 40 watt mini glass lamp, lamp holder, including 9 Watts LED bulb for fixing in decorative wall mounting light and all accessories pre-wired including connecting up including taking down of existing u/s light fitting complete
S&F in repair Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete complete
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 50 mm bore light grade G. I. tube mounting bracket of 1.5 meter in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts & washers complete
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 50 mm bore light grade G. I. tube mounting bracket of 1.5 meter in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts & washers complete
Taking down of existing u/s highbay lights and Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. and all accessories complete, arrangements for mounting of fitting i.e. bracket, clamps, nuts, bolts and washers etc all as per site requirement including connecting up with provision of PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections complete.
Removal of existing UNSV fitting, Supply and fixing garden light fitting 10 watts, IP65 rated LED Bollard light including of brick/PCC work all as specified and directed
Supply and fixing in repair ultra bright compact 6/8 Watt round LED downlighter recess/surface with high efficiency LED,s idealy suited for low ceiling areas to give glare light IP-54 in 6500K with integraed driver to delivered superior light output and uniformity utilising the latest LED technology, ceiling cutout 95 mm mm dia hight max 83 mm recess luuminaries all as specified and directed.
Supply and fixing in repair 12 Watt round LED panel recess/surface mounting downlight in CDL with integraed driver to delivered superior light output and uniformity utilising the latest LED technology, ceiling cutout 145mm mm dia hight max 35mm recess luuminaries all as specified and directed.
Supply and fixing in repair 15 Watt round LED panel recess/surface mounting downlight in CDL with integraed driver to delivered superior light output and uniformity utilising the latest LED technology, ceiling cutout 145mm mm dia hight max 35mm recess luuminaries all as specified and directed.
Material and labour for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed, including taking down old sub main wiring.
All as per the description of srl item No 27 above but for 02x1.5 Sqmm for phase & neutral and 01x 1.5 Sqmm for continuous earth wire
All as per the description of srl item No 27 above but 06 Sqmm nominal cross sectional area.
All as per the description of srl item No 27 above but 10 Sqmm nominal cross sectional area, four single core, with and including continuous earth wire of size 06 Sqmm nominal cross sectional area.
S&F in repair industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 230 volts of 20 Amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete
S&F in repair industrial type TPN enclosure with a three pin and neutral and earth plug and socket complete with and including 32 Amps MCB, four pole, AC, 415 volts and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete
S&F in repair industrial type TPN enclosure with a three pin and neutral and earth plug and socket complete with and including 63 Amps MCB, four pole, AC, 415 volts and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete
S&F in repair sheet metal enclosure distribution board, single pole and neutral, AC, 230 volts, 08 way, with 200 Amps rated copper bus bar and metal double door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete
S&F in repair sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 200 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed and comprising of the following :- (a) MCCB, 125 Amps, 04 pole, AC, 415 Volts,16 KA - 01 No. (b) MCB, SP, AC, 230 volts of 06 to 32 Amps, "C" curve, 10 KA - 12 Nos.
S&F sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 400 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed and comprising of the following:- (a) MCCB, 250 Amps, 03 pole, AC, 415 Volts, 25 KA - 01 No. (b) MCB, SP, AC, 230 volts of 63 Amps, "C" curve, 10 KA - 12 Nos.
S&F in repair MCB, SP, AC, 230 volts of 06 to 32 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using copper lugs complete
All as per the description of srl item No 32 here-in-before but SPN 16-40 AMP
S&F in repair MCB, DP, AC, 230 volts of 40 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using copper lugs complete
S&F in repair MCB, DP, AC, 230 volts of 63 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using copper lugs complete
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200mm, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed
S&F in repair MCCB, 63 Amps, 03 pole, AC, 415 Volts of 16 KA breaking capacity complete
S&F in repair MCCB, 100 Amps, 03 pole, AC, 415 Volts of 16 KA breaking capacity complete all as specified & directed.
S&F in repair MCCB, 125 Amps, 03 pole, AC, 415 Volts of 16 KA breaking capacity complete.
S&F in repair MCCB, 160 Amps, 04 pole, AC, 415 Volts of 36 KA breaking capacity complete
S&F in repair MCCB, 200 Amps, 04 pole, AC, 415 Volts of 36 KA breaking capacity complete
S&F in repair MCCB, 250 Amps, 04 pole, AC, 415 Volts of 36 KA breaking capacity complete
S&F or passing through pipe, 10 Sqmm, 2 core, 1100 Volts grade, heavy duty, multi-stranded, PVC insulated, aluminium conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed service cable for service connections from existing LT Panel/Pole to DB/busbar chamber including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete
S&F in repair Supply and fixing LED luminaire 4 X 1 feet, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete complete
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450MM sweep with, blades, and frame and louvers and taking down old exhaust fan and depositing to MES store yard, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300MM sweep with, blades, and frame and louvers and taking down old exhaust fan and depositing to MES store yard all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete. (Note: On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.)
J V ENGINEERS / JAI SINGH
M P TYAGI ENGINEERS AND CONTRACTORS
M/s Prakash Enterprises
Shiv Enterprises
SANJEEV ENTERPRISES
NEETU TRADERS (INDIA)
POONAM ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .