Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹3.7 LAccepted-AOC 232 PATEL CHOWK PHUSRO BAZAR BOKARO 829104 | BOKARO | JHARKHAND | 829104 | l1 | Accepted-AOC l1 | |
| 2 | l2₹3.8 L+₹7,991.40 (2.14%)Rejected-Finance MAIN ROAD PHUSRO DIST BOKARO JHARKHAND 829144 | BOKARO | JHARKHAND | 829144 | l2 | Rejected-Finance l2 | |
| 3 | l3₹3.9 L+₹12,491.80 (3.35%)Rejected-Finance OLD KARO BERMO DIST BOKARO | BERMO | BOKARO | l3 | Rejected-Finance l3 |
| Sl No | Description | Qty | Unit | Sagar Enterprises L2 | M/s Jitendra Enterprises L3 | SANJAY KUMAR TIWARI L1 |
|---|---|---|---|---|---|---|
| 1.01 | Erection of Metalic Pole of above 8 meter and upto 10 meter in cement concrete 1:3:6 (1 cement:3coarse sand:6graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required | 15 | no. | 6,000 ₹90,000 Lowest | 6,000 ₹90,000 Lowest | 6,000 ₹90,000 Lowest |
| 1.02 | Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required. (14 span x 50 m x 2 wire) = 1400 m x 0.394 kg/m = 551.6 kg. | 551.6 | kg | 215 ₹1,18,594 | 215 ₹1,18,594 | 210 ₹1,15,836 Lowest |
| 1.03 | Erection of 6 SWG G.I. wire (for Earthing & Cradling): (50 m x 3) x 11 span = 1650 m x 0.116 kg = 191.4 kg | 191.4 | kg | 35 ₹6,699 Lowest | 40 ₹7,656 | 35 ₹6,699 Lowest |
| 1.04 | Supplying and erection of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required. | 34 | set | 1,000 ₹34,000 Lowest | 1,000 ₹34,000 Lowest | 1,000 ₹34,000 Lowest |
| 1.05 | Supplying and erection of 100 mm X 110 mm shackle insulator complete with G. I. Bolt, nuts and straps etc. as reqd. | 68 | set | 175 ₹11,900 | 175 ₹11,900 | 170 ₹11,560 Lowest |
| 1.06 | Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required. [(50 m x 2 wire x 14 span)] x 0.394 kg/m = 551.6 kg + 22 no. Channel Iron = 551.6 kg + (7.14 kg x 22 no.) = (551.6 + 157.08) kg = 708.68 kg | 708.68 | kg | 75 ₹53,151 | 80 ₹56,694.4 | 70 ₹49,607.6 Lowest |
| 1.07 | Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. | 12 | no. | 2,000 ₹24,000 Lowest | 2,000 ₹24,000 Lowest | 2,000 ₹24,000 Lowest |
| 1.08 | Supplying and erection of stay set complete (galvanised) with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required | 9 | no. | 4,750 ₹42,750 | 4,750 ₹42,750 | 4,600 ₹41,400 Lowest |
| 2.00 | Total impact of GST for the purpose of CTC | 1 | Nos | - | - | - |
Tender Value
₹4.0 L
EMD Value
₹5,100
Closing Date
27 Feb 2025, 11:00 amClosed
PE EnM Karo OCP
OFFICE OF PE EnM Karo OCP
Repair, dismantling cum erection of 220 V OH Electric OH Line in the approach road leading to the H patch Pump location, in Mine, w.r.t. Karo OCP, under BnK Area
2025_CCL_329300_1
P.E. (EnM)/ Karo OCP/ e-tender/ 2024-25/ 100
Open Tender
Electrical and Maintenance Works
Item Rate
5 days
KARO OCP
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,100
14 Mar 2026
17 Feb 2025
28 Feb 2025
17 Feb 2025
27 Feb 2025
17 Feb 2025
17 Feb 2025 - 27 Feb 2025
Amount
Erection of Metalic Pole of above 8 meter and upto 10 meter in cement concrete 1:3:6 (1 cement:3coarse sand:6graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required. (14 span x 50 m x 2 wire) = 1400 m x 0.394 kg/m = 551.6 kg.
Erection of 6 SWG G.I. wire (for Earthing & Cradling): (50 m x 3) x 11 span = 1650 m x 0.116 kg = 191.4 kg
Supplying and erection of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required.
Supplying and erection of 100 mm X 110 mm shackle insulator complete with G. I. Bolt, nuts and straps etc. as reqd.
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required. [(50 m x 2 wire x 14 span)] x 0.394 kg/m = 551.6 kg + 22 no. Channel Iron = 551.6 kg + (7.14 kg x 22 no.) = (551.6 + 157.08) kg = 708.68 kg
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Supplying and erection of stay set complete (galvanised) with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required
Total impact of GST for the purpose of CTC
Sagar Enterprises (BID ID -1132343)
M/s Jitendra Enterprises (BID ID -1132339)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .