| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.9 CrAccepted-AOC ROHTAK | ROHTAK | HARYANA | 124001 | ₹18.9 Cr | 1 | Accepted-AOC Accepted |
| 2 | 2₹19.4 CrRejected-AOC 1791 GT SECTOR 7 PART 2 GURGAON | GURGAON | ₹19.4 Cr | 2 | Rejected-AOC Rejected |
| 3 | Rejected-Technical VPO BARI TEHSIL GANAUR SONEPAT 131101 | SONEPAT | SONIPAT | HARYANA | 131101 | - | - | Rejected-Technical Non responsive |
Tender Value
₹16.5 Cr
EMD Value
₹32.9 L
Closing Date
13 Jun 2022, 5:00 pmClosed
Executive Engineer
Provincial Division, PWD B and R Charkhi Dadri,
Construction of SDO (Civil) Complex with 550 Sft (G 2), 950 Sft (G 3), 1900 Sft (G 1), SDM residence and servant quarter at Badhra in Charkhi Dadri Distt. under Provl. Divn. PWD B and R Br., Charkhi Dadri
2022_HRY_222876_1
Construction of SDO (Civil) Complex at Badhra
Open Tender
Civil Works - Buildings
630 days
Charkhi Dadri
Please refer Tender documents.
3 documents required · 3 mandatory
₹20,000
₹32.9 L
Yes
8 Aug 2022
21 May 2022
15 Jun 2022
21 May 2022
13 Jun 2022
21 May 2022
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. (HSR 4.12.1) All kinds of soil
Filling available excavated earth (excluding rock) in trenches, cum plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m..(HSR 4.32)
Deduct - Excavating, supplying and filling of local earth (including royalty) cum by mechanical transport up to a lead of 1 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.(HSR 4.33)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: (HSR 6.1.2) 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: (HSR 6.1.6) 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete 1:5:10 (1 cement : 5 coarse sand zone-Ill graded 10 stone aggregate 40 mm nominal size) of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level. (HSR 6.1.7)
Providing and laying damp-proof course with cement concrete 1 :2:4 (1 cement : 2 coarse sand (zone-Ill): 4 graded stone aggregate 12.5mm nominal size) (HSR 6.8.1) 50 mm thick
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level : (HSR 6.14.1) 1 : 1. 5: 3 ( 1 cement : 1. 5 coarse sand (zone-Ill): 3 cum graded stone aggregate 20 mm nominal size)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Less cement used as per design mix is recoverable. However no extra payment shall be made if excess cement is used as per design mix). (HSR 6.25.1) All works up to plinth level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Less cement used as per design mix is recoverable. However no extra payment shall be made if excess cement is used as per design mix). (HSR 6.25.2). All works above plinth level up to floor IV level First storey
Second storey
Third storey
Fourth storey
Fifth storey/mumty & machine room
Centering and shuttering including strutting, propping etc. and removal of form for (HSR 6.30.1) Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for (HSR 6.30.2) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc First storey
Second storey
Third storey
Fourth storey
Fifth storey/mumty & machine room
Centering and shuttering including strutting, propping etc. and removal of form for (HSR 6.30.3) Suspended floors, roofs, landings, balconies First storey
Second storey
Third storey
Fourth storey
Centering and shuttering including strutting, propping etc. and removal of form for (HSR 6.30.4) Shelves (Cast in situ) First storey
Second storey
Third storey
Fourth storey
Centering and shuttering including strutting, propping etc. and removal of form for (HSR 6.30.5) Lintels, beams, plinth beams, girders, bressumers and cantilevers First storey
Second storey
Third storey
Fourth storey
Fifth storey/mumty & machine room
Centering and shuttering including strutting, propping etc. and removal of form for (HSR 6.30.6) Columns, Pillars, Piers, Abutments, Posts and Struts First storey
Second storey
Third storey
Fourth storey
Fifth storey/mumty & machine room
Centering and shuttering including strutting, propping etc. and removal of form for (HSR 6.30.7) Stairs, (excluding landings) except spiral-staircases First storey
Second storey
Third storey
Fourth storey
Centering and shuttering including strutting, propping etc. and removal of form for (HSR 6.30.13) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards First storey
Second storey
Third storey
Fourth storey
Fifth storey/mumty & machine room
Extra for shuttering in circular work (20% of respective centering and shuttering items) (HSR 6.30.14) First storey
Second storey
Third storey
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 6.33.6) Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, over1aps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 6.34.6) Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1 :3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1:1½ :3 (1 Cement: 1½ coarse sand (zone-111) : graded stone aggregate 20 mm nominal size). (HSR 6.39.1)
Brick work with common burnt clay non-modular bricks Cement mortar 1:4 (1 cement: 4 coarse sand) of class designation 7.5 in foundation and plinth in: (HSR 7.21.1) Cement mortar 1:4 (1 cement: 4 coarse sand)
Brick work with common burnt clay non-modular bricks of class designation 7.5 in foundation and plinth in: (HSR 7.21.2) Cement Mortar 1:6 (1 cement: 6 coarse sand).
Brick work with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : (HSR 7.22.2) Cement mortar 1:6 (1 cement: 6 coarse sand) First storey
Second storey
Third storey
Fourth storey
Fifth storey/mumty & machine room
Half brick masonry with common burnt clay non-modular bricks of class designation 7.5 in superstructure above plinth level up to floor IV level. (HSR 7.28.2) Cement mortar 1 :4 ( 1 cement :4 coarse sand) First storey
Second storey
Third storey
Fourth storey
Brick work with non modular fly ash bricks conforming to IS :12894, class designation 10 average compressive strength in super structure above plinth level up to floor IV level in : (HSR 7.47.2) Cement mortar 1:6 (1 cement: 6 Coarse sand) First storey
Second storey
Third storey
Fourth storey
Fifth storey/mumty & machine room
Brick work with modular extruded brunt fly ash clay sewer bricks (Conforming to IS: 4885 ) in cement mortar 1 :4 (1 cement : 4 coarse sand) in foundation and plinth : (HSR 7.48.1) Cement Mortar 1 :4 ( 1 cement : 4 coarse sand)
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (HSR 8.27.2) Granite work Ground floor
First floor
Second floor
Providing gola 75x75 mm in cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1 :3 (1 cement : 3 fine sand) as per standard design : (HSR 9.17.1) In 75x75 mm deep chase First storey
Second storey
Third storey
Fourth storey
Fifth storey/mumty & machine room
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1 :3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (HSR 9.18) First storey
Second storey
Third storey
Fourth storey
Fifth storey/mumty & machine room
Supplying and fixing in position 60 cm long G.I. pipe class 'B' spouts in chajjas and cantilevers (HSR 9.55.5) 50 mm internal dia First storey
Second storey
Third storey
Fourth storey
Fifth storey/mumty & machine room
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (HSR 9.57.2) 110 mm diameter First storey
Second storey
Third storey
Fourth storey
Fifth storey/mumty & machine room
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (HSR 9.57.3) 150 mm diameter First Storey
Second Storey
Third storey
Fourth storey/mumty & machine room
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 1 O mm gap for thermal expansion. (HSR 9.58.5.2) Bend 87.5". 110 mm bend First Storey
Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling. (HSR 10.1)
Providing and laying of screed of 50 mm thick cement concrete 1 :8:16 to be laid below the topping. (HSR 10.4) Ground floor
First Floor
Second floor
Third floor
Fourth floor/mumty & machine room
Providing and laying of conglomerate floor 50mm thick cement concrete topping 1 :2:4 (HSR 10.7)
Providing and laying of chequered terrazzo tiles 20 to 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement sluny mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1 :4 (1 cement : 4 coarse sand) (HSR 10.29.4) Ordinary cement without any pigment Ground floor
Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 ( 1 cement : 4 coarse sand) : (HSR 10.37.1) 25 mm thick Ground floor
First Floor
Second floor
Third floor
Fourth floor/mumty & Machine room
Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (HSR 10.38) Ground floor
First floor
Second floor
Third floor
Fourth floor/mumty & Machine room
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. (HSR 10.42) Ground floor
First Floor
Second floor
Third floor
Fourth floor/mumty & Machine room
Fixing of marble stone flooring with 16 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1 :4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with: (HSR 10.44.1) Makrana white second quality. (Labour Rate) Ground floor
First Floor
Second floor
Third floor
Extra for pre finished nosing to treads of steps of marble stone. (HSR 10.45) Ground floor
Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre. (HSR 10.46) Ground floor
First Floor
Second floor
Third floor
Laying Baroda Green marble stone 17mm and above thick in risers of step, skirting , dado, pillars and wall lining included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1 :3 and jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. (HSR 10.47) (Marble shall be Supplied by the department). (Labour Rate) Ground floor
First floor
Second floor/mumty & machine room
Laying Baroda Green marble stone 17mm and above thick flooring included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1 :3 and jointed with white slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. (HSR 10.48) (Marble shall be Supplied by the department). (Labour Rate) Ground floor
First floor
Second floor/mumty & machine room
Laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1 :4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (HSR 10.50.1) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. (Labour Rate) Ground floor
First floor
Second floor
Third floor
Fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1 :3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. (HSR 10.51). (Labour Rate) Ground floor
First floor
Second floor
Third floor
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1 :3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (HSR 10.58) Ground floor
First floor
Second floor
Third floor
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1 :4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc.,complete. (HSR 10.59) Ground floor
First floor
Second floor
Third floor
Laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (HSR 10.63.2) Size of Tile 600x600 mm. (Labour Rate) Ground floor
First floor
Second floor
Laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. (HSR 10.67.2) Size of Tile 600x600 mm. (Labour Rate) Ground floor
First floor
Second floor
Providing and laying 80mm thick factory made cement concrete inter1ocking paver block of M -35 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over (BIS 15658:2006) and including 60mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. (HSR 10.77)
Cement Concrete 1:8:16 with stone aggregate 40 mm size in cum foundation and plinth.(HSR 10.100.2)
Plastering on walls 10 mm thick cement plaster 1 :3 (1 cement: 3 fine sand) (HSR 11.4.2) First Storey
Second Storey
Third storey
Fourth storey
Fifth storey/mumty & machine room
Plastering on walls12 mm cement plaster of mix 1 :4 (1 cement: 4 fine sand) : (HSR 11.5.3) First Storey
Second Storey
Third storey
Fourth storey
Fifth storey/mumty & machine room
Plastering on wall 12 mm cement plaster of mix 1 :6 (1 cement: 6 fine sand) : (HSR 11.5.4) First Storey
Second Storey
Third storey
Fourth storey
Fifth storey/mumty & machine room
Plastering on walls 15 mm cement plaster on the rough side of single or half brick wall of mix 1 :6 (1 cement: 6 fine sand): (HSR 11.6.2) Internal Plaster
First Storey
Second Storey
Third storey
Fourth storey
Fifth storey/mumty & machine room
Applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete (HSR 11.58). (Labour Rate)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: (HSR 11.64.1) New work (two or more coats) over and including water thinnable priming coat with cement primer. (Labour Rate)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer. (HSR 11.67.1). (Labour Rate)
Applying priming coat With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works. (HSR 11.68.3). (Labour Rate)
Wall painting on a cement plaster surface with acrylic emulsion paint of approved brand and manufacture to give an even shade: (1) Two or more coats on new work. (HSR 11.71.1). (Labour Rate) First storey
Second storey
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. (HSR 11.76). (Labour Rate)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. (HSR 11.77). (Labour Rate)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 11.78). (Labour Rate)
Painting over the wooden/metal surface with aluminium paint of approved brand and manufacture to give an even shade. (HSR 11.84.1) Two or more coats on new work. (Labour Rate)
Finishing walls with water proofing cement paint of required shade (HSR 11.93.1) New work (Two or more coats applied@ 3.84 kg/10 sqm). (Labour Rate)
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gmnitre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. (HSR 11.98.1) New work (Two or more coats applied@ 1.43 litre/ 10 sqm Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. (Labour Rate)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid separately). Kiln seasoned and chemically treated Hollock wood (HSR. 12.1.3)
12 mm thick pre-laminated particle board (decorative lamination on both sides) grade -1, medium density flat pressed, three layer particle board FPT- I or graded wood particle board FPT- I, conforming to IS : 3087, bonded with BWP type synthetic resin adhesive as per IS : 848 and pre-laminated conforming to IS : 12823, Grade 1, Type - II marked: (HSR 12.8.2)
Float glass panel. (HSR 12.9.7.1) 4 mm thick glass panel (weight not less than sqm 10kg/sqm).
Float glass panes. (HSR 12.9.7.2) 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISi marked M.S. pressed butt hinges bright finished of required size with necessary crews. (HSR 12.10.2.1) Kiln seasoned and chemically treated Hollock wood. 35 mm thick shutters
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws: 30 mm thick shutters. (HSR 12.19.2.1.2) Kiln seasoned and chemically treated Hollock wood
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (HSR 12.36.1) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Fixing aluminium e xtruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS: 3564, embossed on the body, door weight up to 3 6 kg to 80 kg and door width from 701 mm to 1 000 mm), with double speed adjustment with necessary accessories and screws etc. complete.(HSR 12.89). (Labour Rate)
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (HSR 12.90)
Fixing ISi marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: (HSR 12.97.6) 75x63x4 mm. (Labour Rate)
Fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (HSR 12.98.1) 300x16 mm. (Labour Rate)
Fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (HSR 12.98.2) 250x16 mm. (Labour Rate)
Fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete (HSR 12.99.1) 300x10 mm. (Labour Rate)
Fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete (HSR 12.99.2) 250x10 mm. (Labour Rate)
Fixing aluminium handles, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete. (HSR 12.102.1) 125 mm. (Labour Rate)
Fixing aluminium handles, ISi marked, anodised (anodic coating not less than grade AC 1 O as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete. (HSR 12.102.3) 75 mm. (Labour Rate)
Providing Aluminium Jali of thickness 7mm thick with openings - 75mm X sqm 75mm of including anodizing and fixing in frame with cost of screws etc. (HSR 12.107)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). (HSR 12.157.1.1) Anodised aluminium (anodised transparent or kg dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). (HSR 12.157.2.1) .Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B (HSR 13.3.1.1) Fixing with adjustable lugs with split end tail to each jamb First storey to fourth storey & fifth storey /Mumty & machine room
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C (HSR 13.3.2.1) Fixing with adjustable lugs with split end tail to each jamb
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (HSR 13.29.2) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpos only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (HSR 13.41)
Construction of Embankment CBR 8% (for new road/ raising/ berms/ etc.) with approved material obtained from borrow pits, including compensation of earth with all lead and lift transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2, as per technical clause 305 of MORT&H specifications. (HSR 17.6) Note:- Compensation for earth w ill vary from place to place and will have to be assessed realistically as per particular ground situation. In case earth is available from Govt. land, compensation for earth will not be required. The position is required to be clearly stated in the cost estimate.
Compaction of & preparation of sub grade including loosening, levelling of earth 225 mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 3000-2 as per technical clause 305 of MORT&H specifications (HSR 17.5.3)
Granular Sub-Base with Coarse Graded Material - Grading-I or II or Ill (Table:- 400-2) Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.of MORT&H specifications. (HSR 17.15.1) Grading I material
Water Bound Macadam - II with crushable screenings Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications (HSR 17.23.3)
Dry Lean Cement Concrete Sub- base Construction of dry lean cement concrete Subbase over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15: 1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing, as per clause 601 of MORT&H specifications Note:- Quantity provided for aggregate is for estimating purpose. Exact quantity shall be as per mix design. (HSR 17.44)
Cement Concrete Pavement:- Construction of un-reinforced M-40 grade concrete pavement with dowel jointed, over a prepared sub base with 43 grade OPC cement concrete coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a fully computerised batching and mixing plant as per approved mix design, transported to site in transit mixer with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing, complete as per clause 602 of MORT&H specifications. (HSR 17.45)
Providing and fixing Pre-laminated medium density fibre board IS: 14587:1998 marked, with one side decorative lamination other side balancing lamination Grade-l(exterior grade) in shelves with screws and fittings wherever required, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand (fittings to be paid separately).(HSR 18.12.1) Pre-laminated with decorative lamination one side and other side balancing lamination exterior Grade - I MDF Board 18 mm thick confirming to 15:14587 First storey
Second storey
Third storey
Fourth storey/mumty & machine room
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1 :4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1: 1, including rubbing and polishing of the surface up to 3 cuts complete, including providing skirting up to 150 mm height along the parapet walls in the same manner. (HSR 28.43) First storey
Second storey
Third storey
Fourth storey
Fifth storey/mumty & machine room
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface# 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face# 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevant Item). "(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VL T) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0. 25- 0.28) and U value of 3.0 to 3.3 W/m 2 K etc . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. (HSR 29.5)
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (HSR 29.6)
(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part Ill (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminium sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimensional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon separator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers
(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass
(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight
(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer,dully approved by Engineer-in charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.
Notes for Item 29.6: (1). The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm up to two decimal places
2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately.
3. Competent authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work
3.1. Performance Laboratory Test for Air Leakage Test (-50pa to· 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr
3.2. Static Water Penetration Test (50pa to 1500pa) as per ASTME· 331·09 testing method for a range up to 2000 ml
3.3 Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01· 05 testing method for a range up to 2000 ml
3.4 Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range up to 50 mm
3.5 Seismic Movement Test (up to 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site
3.6 Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) up to 2000 ml
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: (HSR 4.16.1.1) All Kinds of soil. Pipes, cables etc, not exceeding 80 mm dia.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: (HSR 4.16.1.2) All Kinds of soil. Pipes, cables etc. exceeding 80 mm metre dia. but not exceeding 300 mm dia.
Drilling and tapping cast iron pipe line of all diameters and screwing in ferrule and connections. (HSR 20.24.6) 40mm I/d
Cutting holes upto 23 cm square through brick work in mud walls for pipes and making good including repointing replastering and finishing according to existing finish where required. (HSR 20.25.1) (a) 11.43 cm thickness of walls
Cutting holes upto 23 cm square through brick work in mud walls for pipes and making good including repointing replastering and finishing according to existing finish where required. (HSR 20.25.2) (b) 22.86 cm thickness of walls
Bailing out water from the trenches for making new connections in fully charged pipe lines including cleaning, trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge. (HSR 20.49.1) (a) Upto 200mm I/d
Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below: Top layer: - Fine sand screened, cleaned and washed and graded (effective size 0.2 to 0.4 mm with uniformity coefficient 2.0 to 3.0) from Ghaggar or other approved source. (HSR 20.52.1)
Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below: Second layer :- coursed sand screened, cleaned and washed and graded from 3 mm to 6 mm (from Ghaggar or approved equivalent quarry) (HSR 20.52.2)
Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below: Third layer: - Bajri screened washed and graded from 6 mm to 20 mm (from Ghaggar or approved equivalent quarry) (HSR 20.52.3)
Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below: Fourth layer: - Bajri (coarsed) screened and washed graded from 20 mm to 25 mm (from Ghaggar or approved equivalent quarry) (HSR 20.52.4)
Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below: Bottom layer:- Broken stone, screened, washed and graded from 50 mm to 75 mm (from Ghaggar or approved equivalent quarry) (HSR 20.52.5)
Providing, lowering, laying, cutting (cut surface to be uniformly finished), jointing with rubber rings marked with IS : 5382 and testing of SPIGOT AND SOCKETTED RCC, NP2 MARKED WITH IS : 458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete is all respects to the satisfaction to the Engineer - in -charge. (HSR 20.62.1) 200 mm i/d
Providing & fixing steel bar embedded plastic steps of size 263mm x each 143 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS : 1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1 :2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge. (HSR 21.28)
Constructing brick masonry inspection chamber sizes as given below upto 0.60 meters average depth in cement mortar 1:5 lime concrete with 40 percent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement RCC 1:2:4 slab 100mm thick/C.C. topping 50mm thick with 455 mm x 455 mm / 455 mm x 610mm inside light duty C.I inspection chamber cover and frame weight as per I.S.I specification painted with 3 coats of black bitumastic superior paint complete as per standard design. (HSR 21.84.1) (a) Size 450mm x450mm inside (with 455mmx455mm cover and frame light duty single seal weighing 20 kg with C.C topping
Constructing brick masonry inspection chamber sizes as given below upto 0.60 meters average depth in cement mortar 1:5 lime concrete with 40 percent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement RCC 1:2:4 slab 100mm thick/C.C. topping 50mm thick with 455 mm x 455 mm / 455 mm x 610mm inside light duty C.I inspection chamber cover and frame weight as per I.S.I specification painted with 3 coats of black bitumastic superior paint complete as per standard design. (HSR 21.84.3) (C) Size 600mm x900mm inside (with 455mmx455mm cover and frame light duty single seal weighing 20 kg with C.C topping RCC slab
Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1 :3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. C Type: Extra heavy duty set (MD-10) 560 mm clear opening. (HSR 21.93.1) Type: Extra heavy duty set (EHD-35) 560 mm clear opening
Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink without drain board (HSR 22.10.2.1) 610x510 mm bowl depth 200 mm
Providing and Fixing in position C.I. plain Nahani Trap conforming to I.S.I. specifications and of self cleaning design with C.P. brass hinged grating with frame complete. (HSR 22.20.2) (b) With 75mm I/d outlet.
Fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (HSR 22.22.1) White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. (Labour Rate)
Fixing white vitreous chinaware pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinaware flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (HSR 22.24.1) W.C. pan with ISi marked white solid plastic seat and lid . (Labour Rate)
Fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass)with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required HSR 22.26.3 Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern. (Labour Rate)
Providing and Fixing G.I. inlet connection for flush pipe connecting with W.C. pan. (HSR 22.35)
Providing and Fixing 8 mm dia C.P. I S.S. Jet with flexible tube up to 1 metre ong with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. (HSR 22.38)
Fixing toilet paper holder: (HSR 22.42.1) C.P. brass. (Labour Rate)
Providing and Fixing 32 mm diameter GI. extension pipe for Indian type Water Closet suite complete with accessories(as approved by the Engineer -in charge. (HSR 22.44)
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work· Exposed on wall :- (HSR 22.88.3) 25mm.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work· Exposed on wall :- (HSR 22.88.4) 32mm
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work· Exposed on wall :-(HSR 22.88.5) 40mm
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : (HSR 22.89.2) 20mm
Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. (HSR 22.90)
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : (HSR 22.94.2) 20 mm
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : (HSR 22.94.3) 25mm
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : (HSR 22.94.4) 32mm
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : (HSR 22.94.5) 40mm
Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). (HSR 22.95)
Providing and fixing Gun Metal Gate valve with CI wheel of approved qualtity screwed end. (HSR 22.98.1) 25mm internal diameter
Providing and fixing Gun Metal Gate valve with CI wheel of approved qualtity screwed end. (HSR 22.98.2) 20mm internal diameter
Providing and fixing Gun Metal Gate valve with CI wheel of approved qualtity screwed end. (HSR 22.98.3) 32mm internal diameter
Providing and fixing Gun Metal Gate valve with CI wheel of approved qualtity screwed end.(HSR 22.98.4) 40mm internal diameter
Fixing C.P. brass bib cock of approved quality conforming to IS:8931. (HSR 22.104.1) 15mm nominal bore. (Labour Rate)
Fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. (HSR 22.106.1) 15mm nominal bore. (Labour Rate) .
Fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. (HSR 22.107.1) 15mm nominal bore. (Labour Rate)
Fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. (HSR 22.108). (Labour Rate)
Fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. (HSR 22.109). (Labour Rate)
Fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (HSR 22.119.2) 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. (Labour Rate)
Fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. (HSR 22.120). (Labour Rate)
Providing and Fixing Unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. (HSR 22.128.2). 15 mm nominal bore with 45 cm length. .
Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536: (HSR 22.152.1) 100 mm dia pipe.
Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536: (HSR 22.152.2) 125 mm dia pipe.
Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead. (HSR 22.153.1) 100 mm dia pipe
Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead. (HSR 22.153.2) 125 mm dia pipe
Supplying pig lead at site of work. (HSR 22.154)
Providing and laying S&S C.I. Standard specials such as tees, bends, collars apers and caps etc, suitable for flanged jointing as per IS : 1538 : (HSR 22.157.1). Up to 300 mm dia
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1: 1 (1 cement : 1 fine sand) including testing of joints etc. complete: (HSR 22.163.1) (i) 100 mm i/d
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1: 1 (1 cement : 1 fine sand) including testing of joints etc. complete: (HSR 22.163.2) (ii) 150 mm i/d
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design (HSR 22.164.1) (i) 100 mm i/d
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design. (HSR 22.164.2) (ii) 150 mm i/d
Providing and Providing and Fixing square-mouth S.W. gully trap (180x150 mm) size P type class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg andframe to be not less than 2.70 kg as per standard design: (HSR 22.166.3.1) (a) 100mm internal diameter S.W gully trap.
Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. (HSR 22.182)
Providing and Fixing 600x450 mm bevelled edge mirror of superior glass of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (HSR 22.209).
Providing and fixing in position best Indian make coat and hat hooks fixed into wall with C.P. brass screws and rawl plugs etc. complete including cutting and making good the walls etc. (HSR 22.212.1.2). C.P Brass Two Way
Fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. (HSR 22.221.9) Size 560mm x 450mm (Under counter oval). (Labour Rate)
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single socket Type A (HSR 22.222.1.1). 160mm old SWR UPVC pipe lines laid complete
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, up to 90 metre depth below ground level. (HSR 33.6.1.1) Up to 300 mm dia
FIRE HYDRANT SYSTEM Providing laying ,testing & commissioning of ( C ) class heavy duty MS pipe conforming to IS 3589/ IS 1239 including Welding ,fittings like elbows ,tees ,flanges,tapers ,nuts bolt ,gaskets etc . And fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complite as required. MAKE HISAR JINDEL, TATA ,PARKSH SURYA. 250 mm dia (MINIMUM 6.3 MM THIKNESS) (N.S)
200 mm dia (MINIMUM 6.3 MM THIKNESS) (N.S)
100 mm dia (N.S)
80 mm dia (N.S)
25 mm dia (N.S)
Providing laying ,testing & commissioning of (C) class heavy duty MS pipe conforming to IS IS 1239 /3589 i/c fitting like elbows ,tees ,flanges ,tapers ,nuts bolt , gaskets etc .in ground including welding ,excavation & providing cement concrete blocks as supports , anticorrosive treatment with coaltar /asphalt tape as per IS 10221 reffilling the trench etc .of following sizes complete as required make PYPECOAT/COALTEK 150 mm dia (MINIMUM 6.3 MM THIKNESS) (N.S)
Supplying and fixing single headed internal and external yard hydrent valve with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (TYPE -A) with blank stainless steel cap and chain as required (DSR code No. 9.2)
SITC of INTERNAL OR EXTERNAL weather proof standard fire hose cabinet (750 mm x 600 mm x 250 mm deep) for yard hydrants made of 16 SWG powder coated M.S. sheet having single or double opening glazed (4.0 mm thick glass) shutter including necessary locking arrangement by allan key, stove enamelled Fire red finish with " Fire Hose" marked on front, suitable for housing 2 nos. Hose pipe, 1 No. branch pipe & nozzle spanner. (For external hydrant system) (MAKE: / FIRE CUT / MINIMAX / NEW AGE/ SUPEREX / CEASE FIRE / SAFEX ) ( N.S )
Supplying and fixing 63 mm dia ,15 m long RRL hose pipe with 63 mm dia male and femaile coupling duly bond with GI WIRE , RIVETS ETC. CONFORMING TO IS 636 (Type -A ) as required. (MAKE: / FIRE CUT /NEWAGE/ / MINIMAX/,/ SAFEX (DSR code No. 16.2)
Supplying & fixing 63 mm dia Stainless Steel (grade 304 ) short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 sutitable for instantaneous connection to iIS 903 sutitable for instantaneous connection to interconnect hose pipe coupling as required (MAKE: / FIRE CUT / MINIMAX / NEW AGE/ SUPEREX / CEASE FIRE / SAFEX ) (DSR code No. 18.2)
Supplying and fixing firsr-aid Hose Reel with MS construction spray painted in post office red , conforming to IS 884 complite with the follwing as required . 20 mm nominal internal dia water hose thermoplastic (Textile reinforced ) type-2 as per IS 12585. 20 mm normal internal dia gun metal globe & nozzle. Drum and brackets for fixing the equipmets on wall.connections from riser with 25 mm dia stop gunmetal valve & MSpipe and socket (MAKE: / FIRE CUT / MINIMAX / NEW AGE/ SUPEREX / CEASE FIRE / SAFEX ) (DSR Code No.17.1)
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd , for sutitable dia MS pipe connection conforming to IS 904 AS REQUIRED .4 WAY -150 mm dia MS pipe (MAKE: / FIRE CUT / MINIMAX / NEW AGE/ SUPEREX / CEASE FIRE / SAFEX ) (DSR code No. 19.2)
Providing , installation , testing and commissioning of stainless steel Y- strainer fabricated out of 1.6 mm thick stainless steel, grade 304 , sheet with 3 mm dia hole with stainless steel flange . 250 mm dia . MAKE KARTAR / SANT (DSR code No. 15.5)
Supplying and fixing air vessel made of 250 mm dia ,8 mm thick MS sheet , 1200 mm in height with air release valve on top and flanged connection to riser , drain arrangement with 25 mm dia gun metal wheel valve with required accessories , pressure gauge and paintingwith synthetic enamel paint of approved shade as required . (MAKE: / FIRE CUT / MINIMAX / NEW AGE/ SUPEREX / CEASE FIRE / SAFEX ) (DSR code No. 20)
SITC OF Providing & Fixing of air vessel 450/1600 0mm dia,height with dish top made in 6mm thick ms pipe complete with 20 mm dia brass air valve , 200mm dia stop valve , pressure gauge ,stop cock, nipple for fire control room (MAKE: / FIRE CUT / MINIMAX / NEW AGE/ SUPEREX / CEASE FIRE / SAFEX ) ( NS )
Supplying and fixing orifice plate made out of 6mm thick stainless steel (Grade 304) with orrice of required size to be fitted between flange & landing valve of external and internal hydrent to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required .MAKE-SANT,LEADER,KARTAR / SAFEX OR EQULENT (DSR code No. 13)
Supplying, fixing, testing and commissioning of butterfly vave of PN 1.6 rating with bronze /gunmetal seat duly ISI markedcomplete with nuts, bolt, washers, gaskets conforming to IS 13095 OF FLOWING SIZES AS REQUIRED MAKE KARTAR / SANT / CASTLE 250 mm dia (DSR code No. 11.8)
150 mm dia (DSR code No. 11.6)
100 mm dia (DSR code No. 11.5)
80 mm dia (DSR code No. 11.4 )
50 mm dia (DSR code No. 11.2)
Providing , installation , testing and commissioning of non-return valve of following sizes confirming to IS 5312 complete with rubber gasket . GI bolt ,nuts , washers etc .as required MAKE- KARTAR / SANT/ CASTLE 250 mm dia (DSR code No. 14.9)
150 mm dia (DSR code No. 14.7)
100 mm dia (DSR code No. 14.5)
providing & fixing of pressure switch in M.S pipe line including connection (DSR code No. 22)
SITC of fire brigade draw off connection confirming to IS : 4038-1986 with 150 mm Non return valve/ strainer incluiding necessary fittings the word FIRE BRIGADE DRAW OFF to be painted on the box complete all as specified and directed.( (MAKE: / FIRE CUT / MINIMAX / NEW AGE/ SUPEREX / CEASE FIRE / SAFEX ) ( N.S )
Providing, fixing, testing & commissioning of 100 mm dia Burden type, Stainless Steel dial type pressure gauge (in Pump Room) including brass isolation valve and pipe having caliberation of 0-15 Kg/cm2. MAKE H.GURU/FIEBIG ( N.S )
MECHANICAL/ELECTRICAL PUMPS-Fire Hydrants Supplying, installation, testing and commissioning of electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required . (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520 (b) suitable HP squirrel cage induction motor ,TEFC , synchronous speed 1500 RPM ,suitable for operation on 415 volt , 3 phase 50 Hz ,ac supply with IP 55 protection for enclosure , horizontal foot mounted type with class ' F ' insulations , conforming IS -325 (c) M.S fabricated ,common base plate coupling ,coupling guard , foundation bolt etc .as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. (Make - 1620 LPM at 70 Mtr Head, (DSR- 1.8)
Supplying , installation , testing and commissioning of electric driven Main Fire Pump suitable for automatic operation and consisting of following , complete in all respects , as required . (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520 (b) suitable HP squirrel cage induction motor ,TEFC , synchronous speed 1500 RPM ,suitable for operation on 415 volt , 3 phase 50 Hz ,ac supply with IP 55 protection for enclosure , horizontal foot mounted type with class ' F ' insulations , conforming IS -325 FOR HYDRENT SYSTEM (DSR- 1.4) 2280 LPM suitable for 88 Mtr Head (DSR- 1.4 )
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required ; (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS; 1520. Suitable HP squirell cage induction motor tefc type suitable for operation on 415 volt , 3 phase 50 HZ AC supply with IP 55 class of protection for enclosure , horzontal foot mounted type with class- ' F 'insulation, conforming to IS; 325 M .S fabricated common base plate , coupling ,coupling guard, foundation bolt etc as required . M.S fabricated bolt etc as required. Suitable cement concrete foundation duly plastered and with anti vibration pad180 LPM suitable for 70 Mtr (DSR- 3.2)
Supplying , installation , testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following , complete in all respects , as required ; (Terrace Pump) (a) Horizontal type , multistage , centrifugal , split casing pump of cast iron body & bronze impeller with stainless steel shsft , mechanical confirming to IS; 1520 (b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volt ,3 phase ,50 Hz , AC supply with IP55 class of protection for enclosure , horiziontal foot mounted type with class - 'F 'insulation , conforming to IS- 325 (c) M.S fabricated common base plate ,coupling ,coupling guard, foundation bolt etc as required . (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 LPM at 35 m head (DSR- 4.2)
SITC OF DOL type fire pump panel suitable for 450 lpm fire pump 415 V+/-6 volts,panel shall be free standing floor mounting sheet metal enclosed dust and verming proof.Panel shall be provided with heat shrinkable sleeves and shall be coloour coded. The panel shall be suitable for cable entry from top or bottem. The minimum fault rupturing for all incoming and outgoing switch/ breakers shall be 35 KA. The panel shall be fabricated.Auto mannual Starters with change over system. MAKE ( N.S )
Supplying and making end termination with brass compression gland and almminium lugs for following size of PVCand PVCsheathed /XLPE almuminium conductor cable of 1.1 KV grade as required (MAKE:RR/FINOLEX/polycab) 3.CORE x 95 sq. mm (From Fire Fighting Control Panel to main fire AND SPRINKLAR pump) (DSR E & M code No. 9.1.13)
3 CORE x 35 sq. mm (From Fire Fighting panel to jockey pump) (DSR E & M code No. 9.1.10)
3.CORE x 10 sq. mm (From Fire Fighting Control Panel to main fire pump) (DSR E & M code No.9.1 .7
Providing , fixing , testing & commissioning of installation control valve of cast iron body , brass /bronze working parts comprising of water moter alarm , bronze seat clapper , clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser / sprinkler system activates , pressure switch, cock valve complete with drain valve and bypass , test control box , ball valves MS PIPE OF REQUIRED SIZE , FLANGES , ORIFICE PLATE , GASKET ETC OF FOLLWING SIZES AS REQUIRED 150 MM DIA (DSR code No. 24.3)
Fabrication , supply, insallation testing & commissioning of electrical control panel of cubical construction , floor mounted type , fabricated out of 2mm thick Crca sheet , compartmentalised with hinged lockable door ,dust and vermin proof ,powder coated of approved shade after 7 tanktreatment process , cable alley ,interconnection with suitable size copper conducor cable /solid copper strip , having switchgears and accessories , numbering etc , completein all respect ,suitable for main fire pump , pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and outgoing , suitable for opreraton on 415v , 3 phase, 50 Hz Ac Supply with enclosure protection class IP 42 as required .
LED type RYB phase indicating lamps , ON , OFF , trip indicating lamps
Set of copper bus baar 500a.
AUTO GLOW EXIT SIGNS AUTO GLOW EXIT SIGNS AND INDICATION SIGNS SIZE 12 "x 6", MAKE FIRE CUT AND ATTACK FIRE ,DP lndication every exit point,fire point,fire extinguisher. (N.S)
FIRE EXTINGUISHERS SUPPLY AND INSTALLATION of ISI marked (ISI MARK 15683) portable Co2 fire extinguisher of capacity 4.5 kg flat base including valve , dischargeone metar long hose of . meter complete in all respect with explosive certificate . MAKE- CEASE FIRE / FIRE CUT/MINIMAX /SAFEX ( N.S )
SITC of ISI marked (IS: 15683) portable ABC multipurpose filled by 90% (MAP ) mono amonioum phosphate powder , nitrogen pressurised type fire extinguisher, Capacity 6 kg with 90% map complete in all resp. MAKE- CEASE FIRE / FIRE CUT/MINIMAX /SAFEX (N.S )
SITC of Clean Agent type ISI mark IS code 15683 2006 Fire Extinguisher capacity: 2 kg location - o.t room ,nursing station ,lab machinry room pantry kitchen MAKE- CEASE FIRE / FIRE CUT/MINIMAX /SAFEX ( N.S )
SITC of 5 kg modular type self operated on 68o temperature Clean Agent type CE certified Fire Extinguisher filled with NAFPIV clean agent gas MAKE location electrical shaft ,electrical control room servar room other places where water or other camical are prohibited .MAKE- CEASE FIRE / FIRE CUT/MINIMAX /SAFEX ( N.S )
SITC of 50 KG DCP (Dry Chemical Powder) Trolley type fire extinguisher as per IS 16018I jet length minimum 8 mtr minimum discharge time 40-50 sec,tested on 30 kgf/cm2 MAKE .location dg room , fire control room , ground floor of every block .MAKE- CEASE FIRE / FIRE CUT/MINIMAX /SAFEX (N.S )
SITC of 50 KG Mechanical Foam AFFF Trolley type fire extinguisher as per IS 16018 jet length minimum 10 mtr minimum discharge time 60-180 sec,tested on 35 kgf/cm2 with 2 kg co2 external fire extinguisher MAKE location dg room , fire control room , ground floor of every block .MAKE- CEASE FIRE / FIRE CUT/MINIMAX /SAFEX ( N.S )
SITC of 9 ltr capacity Fire Bucket made in 16 guage MS filled by 9 kg sand with MS angle stand having arrangement of hanging 6 buckets with shed MAKE- CEASE FIRE / FIRE CUT/MINIMAX /SAFEX ( N.S )
FIRE CHECK DOOR SITC OF 46 mm steel fire check door of 120 minut fire rating confirming to bs 476 part -22 and is 3614 part-11 fabricated with 2 no , 1mm thick galvnized steel sheet sandwiching with proprietary fire resistant insulation materials in between . The door frames are manufactured from 1.5mm thick galvanized steel sheet pressed from to double rebate profile of size 143mm x 57 mm . the door frame and door shutters to finish with powder coating SITC OF 2HR FIRE RATED METAL DOOR MAKE. location- basement stair case, electrical cantrol room and all floor stir case where there is no natural vantilation
UG WATER TANK AND MACHINARY ROOM Supply and fixing of 20000 ltr plastic water tank (5000) for fire fighting system. (HSR 22.182) In case of any difference in the unit & nomeclature of any of the HSR /DSR items of Civil & P.H. work depicted in this DNIT and that given in HSR /DSR, the unit and nomenclture given in HSR /DSR shall be applicable.