Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹26.4 L+₹32,615.75 (1.25%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹27.2 L+₹1.1 L (4.27%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹27.5 L+₹1.4 L (5.42%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest Bidder | |
| 5 | L5₹28.5 L+₹2.4 L (9.22%)Rejected-Finance 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L5 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
23 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
SPL REPAIR TO BLDG NO T-12 AND T-16 AT SEKLU AND SPL REPAIR TO BLDG NO T-10 AND T-1A AT NATU UNDER GE 881 EWS
2023_MES_619726_1
GE/PNH-50/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹72,000
Yes
8 Jan 2024
20 Sept 2023
30 Oct 2023
20 Sept 2023
23 Oct 2023
9 Oct 2023
Amount
B&R PORTION:- Demolition of cement concrete (unreinforced) on ground floor or paving not exc 15 cm thickness (below or above ground level), complete all as specified and directed.
M&L for glazed ceramic coloured/printed digital tiles, Premium quality of size 450x350x7 mm thick fixed as in vertical surfaces such as skirting, dados & repairs to step etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, fixed over and including 10mm thick plaster in CM (1:4), complete all as specified and as directed.
M&L for 50mm thick PCC 1:3:6 Type C-1 (using 20mm graded crushed stone aggregates) laid in alternate bays (not exceeding 2 sqm each) as in plinth protection, finished the surfaces even & fair, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base of hard standing/ floor complete all as specified and directed.
M&L for machine cut Kota stone slab flooring 20-25mm thick , bedded and jointed with grey cement slurry and pointed with grey cement with admixture or pigment to match the shade of Kota stone slab as approved by GE, laid over and including screed bed or bedding layer of mortar 20mm thick in Cement Mortar (1:6) including cutting, grinding and mirror polishing, complete all as specified and directed.
M&L for machine cut pre polished Kota stone 20-25mm thick as in riser of steps, skirting, dado and pillar fixed over & including cement plaster 10mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the kota stone including cutting, grinding and mirror polishing, complete all as specified and directed.
Dismantling plain/corrugated steel sheeting, any gauge, thickness, complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for roof trusses and purlins, complete all as specified and as directed.
S&F Rolled mild steel works as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 410W(Gde E-250), quality 'A' complete all as specified and directed.
All as per item No 9 above but fixing only complete all as specified and directed.
M&L for mild steel work as in hand rails, half round or other stock section or core for wooden hand -rail, straight portion drilled and countrsunk for ballusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cuttings, tops to shapes, as directed, drilling, holes, notching for wire etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-250 Gde E-165 complete all as specified and as directed.
All as per item No 11 above but fixing only complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, valley gutter, ridge & similar works fixed with self tapping screws complete all as specified and directed.
S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and as directed.
S&F in repair galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aparture 1.18 mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M&L for preparation of old steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coats of synthetic enamel paint complete all as specified and directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.5 Sqm each, complete all as specified and directed.
S&F mild steel butt hinges, medium weight, cold rolled, 100mm long, complete all as specified and directed.
S&F aluminium anodised, barrel tower bolts of extruded section of size 100mm and fixed, complete all as specified and directed.
S&F aluminium anodised, barrel tower bolts of extruded section of size 150mm and fixed, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5 Sqm and not exceeding 4Sqm each, complete all as specified and directed.
S&F plain, solid, 2nd class hard wood straight chowkats and frames wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joint etc ,complete all as specified and as directed.
S&F Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20m graded crushed stone aggregate as in bed block or for embedding of holdfasts, complete all as specified and as directed.
S&F 35 mm thick Flush shutters, solid core, construction, with particle board core and plywood face panels, commercial type on both sides, complete all as specified and as directed.
S&F 35 mm thick 2nd Class hard wood gauged and skeleton shutters, open rebated and prepared to receive gauge etc (with sash bars), edges of framing plain, chamfered or grounded, fitted with cut of and mitred beads for securing gauge etc of size of members of shutters as specified in SSR Part-I section 8 clause No. 8.2(a) and fitted to chowkats complete all as specified and as directed.
S&F 300mm long aluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding of extruded section ,complete all as specified and as directed.
M&L for two coat of synthetic enamel paint over a coat of pink primer including preparation of new or previously untreated wooden surfaces of any description, over 10cm width or girth, complete, all as specified and directed.
S&F 2nd class hard wood, 30 mm thick, glazed and skeleton shutter, divided into square, with plain, chamfered or rounded mitered and rebated sash bars, any number of panels, prepared to receive glass, gauge etc. edges of frames chamfered or rounded, fitted with cut and mitered beads for securing glass etc. size of members as specified in SSR Part I clause 8.24 (b) kiln seasoned and chemically pressure treated, complete all as specified and directed.
S&F mild steel butt hinges, medium weight, cold rolled,75mm long, complete all as specified and directed.
S&F aluminium alloy handles, cast type, anodised of size 100mm and fixed, complete all as specified and directed.
S&F aluminium alloy handles, cast type, anodised of size 150mm and fixed, complete all as specified and directed.
S&F 300 mm, mild steel ordinary rat tail, rod pattern springs including roller and roller plate, complete all as specified and as directed.
Taking down cement plaster on wall of any desription incl racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed.
M&L for 15 mm thick rendering in CM 1:6 on stone masonry surfaces or other than fair faces of brick work or on one side of lathing, finished even & smooth without using extra cement, complete all as specified and as directed.
M&L for 15 mm thick rendering in CM 1:4 on stone masonry surfaces or other than fair faces of brick work or on one side of lathing, finished even & smooth without using extra cement, complete all as specified and directed.
M&L for applying two coats of distemper on walls over newly plastered surfaces of wall incl preparation of surfaces complete all as specified and as directed.
M&L for applying two coats of cement base paint on walls over newly plastered surfaces of wall incl preparation of surfaces complete all as specified and as directed.
M&L for applying one coats of distemper on walls over old plastered surfaces of wall incl preparation of surfaces complete all as specified and as directed.
M&L for applying one coats of cement base paint on walls over old plastered surfaces of wall incl preparation of surfaces complete all as specified and as directed.
Material & Labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces of walls complete all as specified and as directed.
M&L for preparation of new plastered wall surfaces , and applying three coat of white wash on walls including cornices, pilasters etc, complete all as specified and directed.
Demolition of RCC of any thickness and any size as in columns, roof slab, chajja, facia and beam etc., complete all as specified and as directed.
M&L for RCC (1:2:4) nominal mix type B1 (using 20mm graded crushed stone aggregates) as in beams, cantilevers, bressumers, lintels, chajjas ,complete all as specified and as directed.
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, binding spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) n. less than 0.9mm dia, complete all as specified and as directed.
Description all as per item No-47 above but 5mm dia and over upto and including 10mm dia in stirrups, spaces, binders,complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams for flat rough finished surface etc, complete all as specified and as directed.
Dismantling of wall and ceiling boards any thickness including cover cover fillets, complete all as specified and directed.
Dismantling timber in scantling 40 sqcm and over in section unframed work, complete all as specified and directed.
S&F 2nd class soft wood (Kail) as in scantling clean swan and fitted in unframed works complete all as specified and directed.
Dismantling of timber scantling under 40sqcm in section unframed work as in fillets, rails, posts, rafters, purlins etc, complete all as specified and directed.
S&F Anodised aluminium snap grid frame work for false ceiling of size 605 x 605mm with hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long 4mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm grid complete all as specified and as directed.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
M&L for walling of random rubble stone masonry brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed.
M&L for walling of random rubble stone masonry brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), (except stone) complete all as specified and directed.
E&M PORTION:- Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
M&L for point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following :-
One light/fan point controlled by one way switch 6 Amp complete all as specified and directed.
One 3/5 pin socket outlet 6 amp on same board complete all as specified and directed.
One 3/5 pin socket outlet 6 amp independent board complete all as specified and directed.
All as per srl item No 59 here in before but for one 3 pin socket outlet 16/20 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 2.5 Sqmm as in continuous earth wire complete all as specified and directed.
S&F in repair ceiling rose, 3 terminal, surface bakelite 65 mm x 50mm, PVC/poly carbonate, insulated body, complete all as specified and directed.
S&F in repair switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed.
S&F in repair socket outlet 2 in 1, 5 pin, 6 Amp flush type universal, complete all as specified and directed.
S&F in repair Switch socket multipurpose combination 2 in 1, 5 pin, 5 Amp flush type universal, complete all as specified and directed.
S&F in repair Switch socket multipurpose combination 2 in 1, 5 pin, 5 and 15 Amp flush type universal, complete all as specified and directed.
S&F in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, complete all as specified and directed.
Supply and fixing in repair inverter LED batten 1x 20W, with square profile and polycarbonate channel, lithium iron battery with charging time of 8 to 10 hours and backup tile upto 04 hours with driver, holder incl LED tube light connecting up with with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Havells cat part No. LHEXACP7FN1W020 or equivalent make as specified in PS
Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver including suitable bracket fixed to wall/ pole complete with IP 65/66 protection complete all as specified and directed.
S&F in repair Lamp holder along with LED inverter type bulb of 12 watt, complete all as specified and directed. Make of LED lamp:- Havells cat part No LHLDEUEEML8R010 or Equivalent cat part of make as specified in Appx 'A' to P.S.
S & F in repair LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Taking out old unsv exhaust fan from site and replacement of exhaust fan steel body, AC single phase, voltage 230 V, 50 Hz, copper winding of sweep 300mm incl all connecting accessories complete all as specified and directed by Engineer-in-charge.
Taking out old unsv ceiling fan from site and replacement with new BLDC ceiling fan of 1200mm sweep, 230 volt, 50 Hz incl all connecting accessories complete all as specified and directed by Engineer-in-charge.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 4 ways built in bus bars suitable for 240 volts, AC, 50 Hz , including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 8 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 12 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair MCB SPN 40-63 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCSNF040 - DHMGCSNF063 or Equivalent cat part of make as specified in P.S.
S&F in repair MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series complete all as specified and directed. Make:-Havells cat part No-DHMGCSPF006-032 or Equivalent cat part of make as specified in P.S.
S&F Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including dismantling unsv earthing, complete all as specified and directed.
S&F in repair Sub main wiring with single core cable 2x 6 Sqmm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade including surface PVC casing caping medium grade alongwith 1x 6 Sqmm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly, complete all as specified and directed. Note:-Three wire of 6 Sqmm and one run of pvc conduit/casing caping shall be measured as one unit.
Supply, laying , jointing and testing in repair of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 16 sqmm 2 core, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts including cable gland of suitable sizes and aluminium lugs for connection, complete all as specified and directed. Make: Finolex / KEI Industries Pvt Ltd / Polycab / Gloster / Universal Cables.
Supply, laying , jointing and testing in repair of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 10 sqmm 2 core, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts including cable gland of suitable sizes and aluminium lugs for connection, complete all as specified and directed. Make: Finolex / KEI Industries Pvt Ltd / Polycab / Gloster / Universal Cables.
M/S BADRI NATH GUPTA
M/S Farooq Ahmed Bhat
M/S KEWAL KRISHAN SANJEEV KUMAR VAID
NATIONAL TRADING COMPANY
JAMWAL CONSTRUCTION CO
M/S KHAN TRADING COMPANY
SUNIL KUMAR SANGEET KUMAR AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .