| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC TUPKHANA PART 1 PO ARUNACHAL PS SILCHAR DIST CACHAR ASSAM 788025 | CACHAR | ASSAM | 788025 | L1 | Accepted-AOC Being L1 Bid | |
| 2 | L2₹5.5 L+₹26,868.50 (5.14%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹6.0 L+₹73,603.50 (14.1%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹6.1 L+₹87,956.90 (16.8%)Rejected-Finance KALIBARI BAZAR TUPKHANA PART I PO ARUNACHAL P S SILCHAR DISTT CACHAR ASSAM 788 025 | SILCHAR | CACHAR | ASSAM | 788025 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
20 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE
GE SILCHAR, PO-ARUNACHAL, DIST-CACHAR, ASSAM-788025
SPECIAL REPAIRS TO ELECTRIC METERING SYSTEM AT VARIOUS LOCATIONS AND CERTAIN OTHER MINOR WORKS AT CIJW SCHOOL VAIRENGTE UNDER GE SILCHAR
2023_MES_580782_1
8771/E8
Open Tender
Civil Works
Item Rate
120 days
VAIRENGTE
Please refer Tender documents
7 documents required · 7 mandatory
₹500
GE Silchar
₹10,000
6 Apr 2023
13 Feb 2023
27 Mar 2023
13 Feb 2023
20 Mar 2023
28 Feb 2023
20 Feb 2023 - 24 Feb 2023
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
Supplying, fixing / laying steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches for water connections complete all as specified and as directed for the following bores:
Supply, laying, connecting and testing XLPE sheathed, armored LT electric power cable (heavy duty) with stranded aluminium conductor of size 10sqmm, 2 core, 1100V grade laid through ducts /pipes /trenches, etc. including necessary cable glands, lugs, etc. complete all as specified and as directed
S&F 2 core 6sqmm cable (flat or circular), 1100V grade, PVC insulated aluminium conductor, served with inner sheathed of PVC tape and overall PVC sheathed in service connections in pump and suspended by insulating hangers not more than 1m apart with and including 4mm suspention wire complete all as specified and as directed
M&L for cutting into existing GI water pipes in position and any location for insertion of tees, tail piece, collars, branch pipes, reducers, etc. at any required length or for additions / alterations, complete all as specified and as directed for the following sizes of pipes: Notes: (a) Excavation and earthwork will be measured and paid separately under respective items herein (b) Both sides cut shall be measured as one unit
M&L for GI/MS flange 6mm thick suitable GI pipes and welding in existing GI pipelines at site, with all necessary allied works complete all as specified and as directed for the following bores of pipes:
S&F gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed, heavy duty, including necessary cutting into existing pipe, threading, inserting new piece of GI pipe of existing size, and earthwork in any type of soil or breaking/cutting into road/interlocking tiles/cement concrete, etc. and making good the disturbed surfaces including taking out old unserviceable valves and disposing off complete all as specified and as directed of the following sizes:
Supplying, fixing and testing on installation sluice valve, cast iron body class PN 1.6, conforming to IS-14846, ISI marked, both ends fanged with brass spindle and brass check nuts with cast iron hand wheel including jointing material like rubber insulation sheet 3mm thick, bolts, nuts and fixed to pipe line complete all as specified and as directed of the following sizes:
S&F ball PTMT valves, high pressure, with polythene float and flynut, screwed suitable for GI pipe or brass ferrule and fixed including taking out old unserviceable valves and disposing off complete all as specified and as directed of the following sizes:
20mm dia
25mm dia
Supplying, installing in position and testing pumping set, monoblock water pump, 1500RPM, 1HP, 220V, 50Hz, electric driven, 3 phase for suitable discharge as required at site, with and including all connected accessories like inlet, outlet, nipples, etc. complete all as specified and as directed
S&F cover fabricated out of 3mm thick MS sheet, higed or welded with frame of MS flat and angle iron of size 50x50x5mm in shapes required at site, with suitable locking arrangements, painting with two coats of black synthetic enamel paint over a coat of red oxide primer duly grouted in position in PCC 1:2:4 type B1 (using 20mm graded stone aggregates) complete all as specified and as directed
M&L for construction of brick masonry valve pit chamber of size 900x900x900mm (internal dimensions) with 100mm thick foundation using PCC 1:3:6 (type C-2) using 40mm graded stone aggregates, 230mm thick brick masonry wall built in CM 1:6, 10mm thick internal and 15mm thick external plastering in CM 1:4, finished even and smooth without using extra cement and 6mm thick MS sheet cover including 50x50x6mm MS angle frame fixed in PCC 1:2:4 type B-1 coping with 25x6mm flat iron hinges, hold fasts, handles, locking arrangements, applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer to all steel surfaces including excavation and earth work in any type of soil and disposal of surplus soil to a distance of not exceeding 50m and demolition of old chamber, including foundation, etc. and disposing off complete all as specified and as directed Note: The cost shall be inclusive of all items of work required for the execution and entire completion of this item and nothing extra shall be paid separately in any other items of BOQ
S&F single phase electronic tamper proof, digital electric energy meter, AC, CT operated with CT ratio of 100/5 energy meter for LT supply, accuracy class 0.5, 240V, 1/5A, 50Hz, with backlit LCD display of rating 5-30A, conforming to IS: 13779, duly fixed in suitable MS box with locks including taking down old / unserviceable meter any type complete all as specified and as directed
S&F three phase electronic tamper proof digital electric energy meter, AC, of rating 10 to 60A, accuracy class 0.5, 240V,50Hz, counter type display, fixed in transparent hinged box conforming to IS: 13779 including taking down old / unserviceable meter any type complete all as specified and as directed
Notes for item Nos. 27 & 28: (i) Old / unserviceable electric meters taken down shall be deposited at MES store including all loading, unloading, carting, etc. and rate quoted shall be deemed to be inclusive of all loading/unloading and carting, etc. as required (ii) Energy meter shall be of makes as stipulated hereinafter (iii) Meters shall be tested for performance as per relevant IS
S&F metering board, powder coated, double door, fabricated outof 1.6mm thick CRCA sheet, of size 750x750x150mm, having bus bar of capacity 150A, with suitable locking arrangements, suitable for mounting switch gears and energy meters including taking down old damaged board and disposing off complete all as specified and as directed
Taking down old submain wiring, any type and size from any location / position and disposing off and making good the disturbed surfaces, etc. complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 4sqmm and 1 run of 4sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC casing capping 25mm wide, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories including taking down old sub-main wiring any type complete all as specified and as directed Notes: (i) 2 runs of 4sqmm main cable, 1 run of earth conductors and 1 run of PVC casing capping as per item shall be measured as one length (ii) Separate casing capping shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of casing shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of conduit as per requirement at site
S&F in repairs MCB TPN 63A, 415V, 'B' series 10kA complete all as specified and as directed
S&F in repairs MCB SP 6 to 32A, 240V, 'B' series, 10kA complete all as specified and as directed
P K ROY & SONS
Anup Kumar Paul Choudhury
M/S SANJIB DEB
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .