GE(W)/HSR-48/2021-22 PROVN OF CHAIN LINK FENCING OF FAFA QTRS P-596 TO P-601 AT MANEKSHAW ENCLAVE AT HISAR MIL STN UNDER GE (WEST) HISAR
2022_MES_506156_2
GE(W)/HSR-48/2021-22
Open Tender
Civil Works
Item Rate
180 days
Garrrison Engineer (West) HISAR MILITARY STATION
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE WEST HISAR
₹34,500
Yes
25 Mar 2022
9 Mar 2022
18 Mar 2022
9 Mar 2022
16 Mar 2022
9 Mar 2022
Amount
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15 deep and getting out including site clearance complete all as specified and directed.
Excavation in post holes each n. exc .50 cum, getting out in soft/loose soil and removing surplus material n. exc 50 mtr and making good disturb surfaces all as specified.
M& L PCC 1:4:8 type D-2 as in fdn of posts and struts complete all as specified and directed.
M&L for plain cement concrete type C-2 1:3:6 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
M & L 10 mm dia MS round bar for fixing of chain link fencing with post complete all as specified and directed.
S & F MS work in posts and struts in fencing including cutting tops to shape as directed , drilling holes notching for wire etc, flat iron fillets for securing wire mesh including all necessary drilling, bolting or riveting etc and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
S & F 10mm dia 40mm long MS screw bolt machine made with hexagonal or Square head at one end and screwed the other,screwed end fixed with washer complete all as specified and directed.
Supply only chain link fencing, galvinised mild steel of mesh 100x100mm size,10 gauge complete all as specified.
Fixing only chain link fencing, including line wires 100x100 mesh, 10 gauge galvinised mild steel to any type of standards, rails, straining bolts, etc. complete all as specified and directed.
M & L two coats of synthetic enamel paint over red oxide primer on new steel surfaces of any description over 10 cm in width or girth not otherwise described including preparation of surfaces complete all as specified.
M & L two coats of synthetic enamel paint over red oxide primer on new steel surfaces of any description not exc 10 Cm in width or girth including preparation of surfaces complete all as specified.
Excavation in trenches n.exc. 1.50 m wide and n.exc. 1.50m in depth for foundation and getting out complete all as specified and directed.
Returning filling in incldg spreading,levelling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated material soils n.exc. 50m and deposited where directed at a level n.exc. 1.5m above the starting point complete all as specified and directed.
M&L for formwork to sides of Concrete foundations ,fottings ,bases of columns ,raft and raft beams ,sides and soffits (if any )of foundation and plinth beams ;and similar work ;vertical or to batter complete all as specified and directed.
M&L for formwork to sides of pillars,posts ,struts,piers,columns and stanchions complete all as specified and directed.
M&L reinforced cement concrete 1:2:4 type B1(20 m graded aggregates) in Foundationas, includings rafts ,footings,foundation beams;plinth beams,bases for columns etc ;basement slabs ,under-reamed piles and mass concrete complete all as specified and directed.
M&L reinforced cement concrete 1:2:4 type B1 (20m graded aggregates)in columns ,pillars ,piers,postsand struts complete all as specified and directed.
M& L for preparation of newly plastered surfaces of wall and applying two coat of cement base paint over one coat of white wash complete all as specified and directed
M&L Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L mild steel bar 5 mm dia over and upto and including 10mm dia in stirrups spacers and binders complete all as specified and directed.
M&L Rendering 10mm thick in cement mortar 1:4 on faces of brick work or concrete work, finished even & fair without using extra cement complete all as specified and directed.
S&FMild steel confirming to Fe 290 Grade E-165 in framned work such as grills ,gratings etc with ends of bars Shouldered and/or riveted or forged into spikes ;framed guard bars;barred iron doors,ladders;rallings and similar as in side hung gate s work complete all as specified and directed.
Supply & fixing Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and l2mm x 279mm at bottom, class 10
S&F FRLS PVC insulated multi stranded FRLS cooper conductor 3X2.5 Sqmm single core 1100 volt from junction box to street light fittings including making the elctric connection both side all as specified and directed
S&F LED street light fitting 60 watt Epoxy coated cover sheet aluminium housing with heat resistant toughtened glass & IP 66 protection complete all as specified and directed.
S&F in street light bracket made to shape out of GI pipe 40 mm bore light grade 1.5 meter length fixed with & including necessary MS Clamps of size 40X5mm including nuts, bolts & washer on pole etc complete all as specified and directed.
S&F of street fixing of Street light PVC junction box of size not less than 310 mm x285mmx180mm made out of polycarbonate having front side openable duly provided with locking arrangement and also provided with 2 Nos aluminium bus bars of rating 32 Amps and 10 amps MCB single pole neutal and provision of 2 Nos cable entries complete fixed to street light pole with proper MS clamp and connected complete all as specified and directed.
M&L for rigid non-metalic PVC conduit 25mm dia including fixing on pole/ wall with fittings such as TEE bends, elbow reducers bell mouth tube ends & fixing accessories such as coupler lock nuts saddlesppie hook etc complete all as specified and directed.
M&L for GI tubing light grade 40mm bore ISI marked for cable protecion fixed to pole under floor/ground complete all as specifed (clams to be measured and paid for separately)
Supply lay jointing, commissioning and testing LT cable XLPE insulated armoured electric power cable with aluminium conductor (heavy duty) 1100 volt grade 10 Sqmm 2 core laid in trenches/duct or fixed to wall /passing through pipe with suitable size cable glands cable lugs complete all as specified and directed.
Excavation in trunches n exc. 1.5 mtr wide and n exc 1.5 mtr in depth for fdn cable pole stay etc and getting out complete all as specified and directed.
All as per above Ser No 32.00 but depth exceeding 1.5 mtr & not exceeding 3.00 mtr complete all as specified and directed.
Returning filling with earth obtained from excavation including spreading watering and consolidating in layers not exc 25 cm thick complete all as specified and directed.
Removing surplus soil to a distance not exc 50 mtr and depositing whrere directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L sand filling in trenches with clean dry and unwashed including gently punning around cables complete all as specified and directed.
supplying and laying bricks common burnt clay building bricks sub Class A designation 75 for cable protection for LT cable aid in trenches complete all as specified and directed.
M&L for PCC 1:2:4 type C-1 using 20mm graded stone aggregate in coping to poles complete including fair finishing to surface all as specified and directed
M&L for PCC 1:2:6type C-1 using 20mm graded stone aggregate as in mass concrete including necessary form work all as specified and directed
M&L for PCC 1:2:8 type D 2, 40 mm graded stone aggregate) as in as for foundation of pole complete all as specified and directed.
S&F to replacement of micromax analog timer T-31 daily switches in accordance with IEC 60730-1 and 60730-2-7 mannual swiching dial with capacity segments clock prescision +/-5 min for the daily time switch -10C to +55C operating temp & suitable contactor relay with complete assy all as specified and directed
M/S RAJINDER SINGH
M/s Devendera construction
PRINCE CONSTRUCTION
moti construction company
M/s INDER CONSTRUCTION COMPANY
m/s AR Construction co
fauji electric works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .