| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC 131 SANGAM NAGAR OPP NATIONAL SCHOOL SANGHVI PUNE 411027 | PUNE | MAHARASHTRA | 411027 | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹32.7 L+₹2.9 L (9.82%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹33.7 L+₹4.0 L (13.5%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹34.0 L+₹4.2 L (14.3%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹36.8 L+₹7.0 L (23.6%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹48.4 L
EMD Value
₹96,820
Closing Date
14 Jun 2021, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIR MAINTANANCE REPLACEMENT OF LT PANELS SERVICING OF ACBS WITH CONNECTED ITEMS UNDER AGE EM II IN GE C KIRKEE
2021_MES_443204_1
8477/E8 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹96,820
Yes
20 Jul 2021
17 May 2021
16 Jun 2021
17 May 2021
14 Jun 2021
31 May 2021
17 May 2021 - 29 May 2021
Amount
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in Hard/dense soil complete all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand/fine crushed stone dust for cushioning to under ground cable providing with a layer of and 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge (Note : punning thickness of 18 cm will be measured for payment)
M&L for providing of bricks, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
Supply, Laying , jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed of following size:-
3.5 core 120 sq.mm.
3.5 core 95 sq.mm.
3.5 core 70 sq.mm.
3.5 core 50sq.mm.
3.5 core 35 sq.mm.
4 core 25 sq.mm.
4 core 16 sq.mm.
Repairs/overhauling of LT air circuit breakers of any make & capacity 1600 to 3200Amps and replacement of minor items like springs, washers, bolt & nuts and other insulating materials etc and also including calibration and testing of control and protection devices of equuipments in the following steps all as directed by Engineer-in-Charge:- (i) Disconnecting and taking out the breaker after taking shut down of the respective panel and check the defects. (ii) Overhauling the ACB by opening all parts and lubricasting the moving parts as per the requirement. (iii) Re-assembling the air circuit breaker complete, installing to its original position, testing and commissioning the breakers for both tripping mechanism and closing mechanism for proper functioning of the breaker all as specified and as directed. Note:- (i) Cost of lubricants or cleaning agent shall be deemed to be included in the unit rate quoted. (ii) Replacing of defective parts will be measured and paid separately.
Repairs/overhauling of LT air circuit breakers of any make & capacity 650 to 1200Amps and replacement of minor items like springs, washers, bolt & nuts and other insulating materials etc and also including calibration and testing of control and protection devices of equuipments in the following steps all as directed by Engineer-in-Charge:- (i) Disconnecting and taking out the breaker after taking shut down of the respective panel and check the defects. (ii) Overhauling the ACB by opening all parts and lubricasting the moving parts as per the requirement. (iii) Re-assembling the air circuit breaker complete, installing to its original position, testing and commissioning the breakers for both tripping mechanism and closing mechanism for proper functioning of the breaker all as specified and as directed. Note:- (i) Cost of lubricants or cleaning agent shall be deemed to be included in the unit rate quoted. (ii) Replacing of defective parts will be measured and paid separately.
Supply only following spares for execution under overhauling item No 1.00 and 2.00 above as per existing ACBs make all as per specified and as directed by Engr-in-Charge at site:-
Indication lamp assembly with LED and reflector of colours RED/YELLOW/GREEN/AMBER
LED type 3 phase digital volt meter Class 1 Make: L&T/Schneider or Equivalent
LED type 3 phase digital Ammeter Class 1 Make: L&T/Schneider or Equivalent
Cast Resin type CT 800/0.2A capacity of suitable size
Cast Resin type CT 1600/0.2A capacity of suitable size
Auxialiary Isolating Contact Assly-24 Way
-do but 36 way
5 (NO+NC) Contacts Auxialiary Switch
UVT Coil
Shunt trip Coil
Closing Coil
Trip indication switch
Spring Charged indication switch
Position indication switch (RS)
Position indication switch (LS)
Mal insertion preventor
Mechanical interlock
Arcing Contacts 6D-8D (Set of 1 Fixed and 1 moving)
Arcing Contacts 10D-12D (Set of 1 Fixed and 1 moving)
Arcing Contacts 16D/16N (Set of 1 Fixed and 1 moving)
Arcing Contacts 20N/20S (Set of 1 Fixed and 1 moving)
Main Isolating (Jaw) Contacts 6N-8N/10N
Main Isolating (Jaw) Contacts 10D-12D/12N
Main Isolating (Jaw) Contacts 16D/16
Main Fixed Contacts (Upper Terminals) 6N-10N
Main Fixed Contacts (Upper Terminals) 10D-12D/12N
Main Fixed Contacts (Upper Terminals) 16D/16N
Main Fixed Contacts (Upper Terminals) 20N(AHA)-20S Drawout type ACB
Lower Terminals with Fitting Plates 6D-10D/06N
Lower Terminals with Fitting Plates 10D-12D/12N(AHA)
Lower Terminals with Fitting Plates 16D/16N(AHA)
Main Moving Contact Assembly 6D-8D
Main Moving Contact Assembly 6N-10N
Main Moving Contact Assembly 10-20D/12N
Main Moving Contact Assembly 16D/16N
Arc Chutes 6D-16D/6N-20N
Spring Charge Motor 6D-16D/06N-20S(AHA)
Control Relay for Spring Charge motor
FRP Safety Shutter Assy 3Pole for 800 to 1600 A
FRP Safety Shutter Assy 4Pole for 800 to 1600 A
Lockable trip Push button
Locking of ACB in isolated position
ACB Mechanical operation counter
Mounting kit for front mounted counter
Shunt Release 240V AC
Shunt release 415V AC
Under voltage release 240V AC
Under voltage release 415V AC
Vertical terminal adaptor for drawout type ACB for 630-1000A ACB
Vertical terminal adaptor for drawout type ACB for 1250-1600A ACB
Microprocessor based protection release type SR18Gi+D
Thermal Magnetic type release type DN1
CTs for L&T ACBs type 800 to 1000 C/H Fix & Drawout
CTs for L&T ACBs type 1250 to 1600 C/H Fix & Drawout
Aluminium Cable lugs/Thimbles upto size 16 to 25 sqmm complete all as specified.
Aluminium Cable lugs/Thimbles of size 35 to 50 sqmm complete all as specified.
Aluminium Cable lugs/Thimbles of size 70 to 120 sqmm complete all as specified.
Aluminium Cable lugs/Thimbles of size 150 to 240 sqmm complete all as specified.
Aluminium Cable lugs/Thimbles of size 300/400 sqmm complete all as specified. Note: (i) The above spares needs to fixed in the existing breakers. cost for fixing is deemed in the item No 7.00 and 8.00 above. (ii) Contractor shall check the suitability before ordering the spares. (iii) Addition/alteration for fixing the the above spares including M&L for minor spares and control wiring is deemed to be included in the rates quoted. No extra payment will be entertained on this account.
Disconnect taking down the unserviceable ACB and S&F new ACB in the existing panel air circuit breaker of rating 800A 4 pole 50 KA, MDO microprocessor based SR 18G release , , fully interlocked casette door, automatic saftey shutters, mechanical ON & OFF indiacators, closing coil and shunt trip coil voltage 220-250 V AC and as per existing CT ratio ACB ensures validity of short circuit tests , service/test isolated position with indicators, Make : Legrand/L&T/ABB/ C&S
Disconnect taking down the unserviceable ACB and S&F new ACB in the existing panel air circuit breaker of rating 1600A 4 pole 50 KA, MDO microprocessor based SR 18G release, fully interlocked casette door, automatic saftey shutters, mechanical ON & OFF indiacators, closing coil and shunt trip coil voltage 220-250 V AC and as per existing CT ratio ACB ensures validity of short circuit tests , service/test isolated position with indicators. Make : Legrand/L&T/ABB/C&S. Note : Contractor has to inspect the site before quoting item Nos 10 to 11. Any modifications/frame work and renewal of suitable size of bus bar for ACB panels and fixing, Testing and commissioning is deemed to be included in the quoted rates.
Taking down old corroded existing LT danger boards and supply and fix new danger notice plate for 440/380V made out of 1.6mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS Clamps/bolts & nuts of approved size 200X150mm complete all as specified and directed by the engineer-in-Charge
All as per item No.12.00 but HT notice plate 11000 Volts of size 250 x 250mm complete all as specified
M&L for earthing complete with hot dip galvanized steel pipe in pipe electrode, outer pipe 88mm dia medium grade and inner pipe 55 mm dia including testing, 3 mtr long and having 50x6 mm terminal on inner pipe to connect earthing strip with 14 mm holes for nut bolts, buried directly and vertically in ground with top edge at 30 cm below ground level after making bore hole of 100 mm dia and 3.3 mtr deep using suitable mechanical drilling machine (for drilling near the specified bldg) connected with galvanized steel earthing lead of 32x6 mm strip with minimum two Nos of GI nut bolits and connected to test point from earthing pit. The electrode pipes should be filled with 2x 25 kg bags of carbon based earthing compound. The resistance of the compound should be less than 0.1 Oms . The compound should be highly conductive, hygroscopic, non magnetic, non corrosive in nature and have best moisture retaining qualities with ph value between7-9. Connected to the earthing test point, Fiber reinforced plastic pit not less than 300x300 mm with pit cover, including necessary returning filling & removal of extra soil , to achieved earth resistance value less than 5 Oms including testing complete all as specified Make U-Protect or equivalent NOTE: IF the desired result not obtained after testing the contractor should do re-eathing without any extra cost.
Supply and lay in trenches GI strip 25 mm x 4 mm for earth continuity earthing all as specified and directed.
-ditto- but 32 x 6 mm complete all as specified and as directed.
M&L for servicing the existing panel duly Isolate/de-energize the supply to the LT Panel Board of capacity from 200 Amps to 1000 Amps and voltage 415 Volts/230 Volts, opening the doors/covers of the cubicle enclosure for carrying out the servicing/maintenance/repairs of the Panel Board, switch gear, metering etc and re-fixing the same in place after repairs including testing and commissioning of the paenl board comprising of the following:- (a) Cleaning the inside switch gear chambers for removing dust, carbon and rusted surfaces including cleaning with blower and apply insulating varnish. (b) Check the condition of the DMC/SMC support insulators including cleaning applying Dr beck red for better IR values and replacement of insulators if required. (c) Tightening up of all bus bar connections, cable connections, replace bolt, nuts wherever required. Note: Contractor has to inspect the site before quoting. Any modifications/frame work and renewal is deemed to be included in the quoted rates.
Disconnecting and taking down existing bus bars 4 wire system from LT panel board cleaning with CTC applying with becktol solution, removing old insulation and providing new heat shrink insulating sleeves, connecting and fixing in the same panel with new nuts, bolts, washers of suitable size complete all as specified and directed.
Disconnecting and taking out old existing worn out control wiring connections incl cable lugs of LT panel board of 4 wire system and supply and connect with new cable PVC insulated, stranded copper conductor 2.5 sqmm incl new copper lugs and nuts, bolts, washers complete all as specified and directed.
Disconnecting and taking out old existing worn out cable lugs, nuts, bolts, washers etc from LT panel board of 4 wire system (incomming and outgoing) and supply and connect with new aluminium lugs and nuts, bolts, washers etc complete all as specified and directed.
Taking out old existing worn out neoprene gasket from shutters of LT panel board single door /double doors or openable on both sides and supply and fix new neoprene gasket complete all as specified and directed.
Removing of old MCCB/ ICTP main switch after disconecting the incoming and out going cables,making modificatin to panel for fixing of MCCB and supply & fixing MCCB 63 Amps 3 pole 25 KA and making conections of cables with & including suitable size nut bolt cable lugs etc in old existing panels all as specifide and directed.make L&T/Legrand/seimens
Removing of old MCCB/ICTP main switch after disconecting the incoming and out going cables,making modificatin to panel for fixing of MCCB and supply & fixing MCCB 100 Amps 3 pole 25 KA and making conections of cables with & including suitable size nut bolt cable lugs etc in old existing panels all as specifide and directed.make L&T/Legrand/seimens
Removing of old MCCB/ICTP main switch after disconecting the incoming and out going cables,making modificatin to panel for fixing of MCCB and supply & fixing MCCB 160 Amps 3 pole 25 KA and making conections of cables with & including suitable size nut bolt cable lugs etc in old existing panels all as specifide and directed.make L&T/Legrand/seimens
Removing of old MCCB/ ICTP main switch after disconecting the incoming and out going cables,making modificatin to panel for fixing of MCCB and supply & fixing MCCB 200 Amps 3 pole 25 KA and making conections of cables with & including suitable size nut bolt cable lugs etc in old existing panels all as specifide and directed.make L&T/Legrand/seimens
Removing of old MCCB/ ICTP main switch after disconecting the incoming and out going cables,making modificatin to panel for fixing of MCCB and supply & fixing MCCB 250 Amps 3 pole 36 KA and making conections of cables with & including suitable size nut bolt cable lugs etc in old existing panels all as specifide and directed.make L&T/Legrand/seimens
Removing of old MCCB/ ICTP main switch after disconecting the incoming and out going cables,making modificatin to panel for fixing of MCCB and supply & fixing MCCB 320 Amps 3 pole 36 KA and making conections of cables with & including suitable size nut bolt cable lugs etc in old existing panels all as specifide and directed.make L&T/Legrand/seimens
Removing of old MCCB/ ICTP main switch after disconecting the incoming and out going cables,making modificatin to panel for fixing of MCCB and supply & fixing MCCB 400 Amps 3 pole36 KA and making conections of cables with & including suitable size nut bolt cable lugs etc in old existing panels all as specifide and directed.make L&T/Legrand/seimens
Removing of old MCCB/ ICTP main switch after disconecting the incoming and out going cables,making modificatin to panel for fixing of MCCB and supply & fixing MCCB 630 Amps 3 pole 50 KA and making conections of cables with & including suitable size nut bolt cable lugs etc in old existing panels all as specifide and directed.make L&T/Legrand/seimens. NOTE FOR ITEM NO 22 TO 29 :(1) The make of spreader link and phase separator should be of the same make of the MCCB (2) The quoted rates are deemed to be included the cost of Nut-bolts washares or clamps required for modification and for fixing of cables for complete work. (3) T he quoted rates are also deemed to be included labour charges for replacement of Lugs/thimbles if required However the Cost of the Lug/ thimble shall be paid separately as supply only under relevant items.
S&F swift- Poly phase Energy Meter Digital Type 3 Phase 4 wire AC 230 Volts 50 Hz of rating 5 Amps with communication port all as per IS- 13779/IEC 61036 Class 1.0 with Provision for housing the energy meter & control wiring with 2.5 Sqmm PVC insulated unsheathed multistranded copper conductor and “Set of CTs (3 Nos) 230V/5A of suitable ratio, 50 Hz including testing & Commissioning complete Make Schneider Cat No EM 6400 all as specified and as directed by the Engineer-in-Charge. Note: Any modification to panel or any enclosure for fixing energy meter is deemed to be included in the rates quoted. No extra payment will be done on this account.
S&F digital type multifunction meter VAF ,PF 3 Phase 4 wire AC 440 Volts 50 Hz of rating 5 Amps with Class 1.0 with Provision for housing the meter & control wiring with 2.5 Sqmm PVC insulated unsheathed multistranded copper conductor and “Set of CTs (3 Nos) 230V/5A of suitable ratio, 50 Hz including testing & Commissioning complete Make Schneider Cat No EM 6459 all as specified and as directed by the Engineer-in-Charge. Note: Any modification to panel or any enclosure for fixing MF meter is deemed to be included in the rates quoted. No extra payment will be done on this account.
Supply and string ACSR Conductors of any size on insulators including binding with conductor complete for LT/HT OH lines on steel tubular pole including jumper connections including dismantling of existing ACSR conductor and removing connections complete all as specified and as directed.
M&L for taking down burnt jumpers and M&L for jumper connection between GOD and drop out fuses and transformers with ACSR conductor of size 6 of 1/3.5mm n.exc. 2m long including aluminium socket clamped both ends and PVC sleeves complete all as directed.
S&F lightning arrester expulsion type complete with all fittings, transmission class, discharge capacity 65 KA suitable for earthed system 22/33 KV complete all as specified including dismantling existing arrester complete all as specified and as directed.
S & F shakle type porcelain,vitreous, white brown insulator including galvanised mild steel straps, washers, insulation bolts,washers and nuts for1100 volt and size of 75 x 90 mm including taking down complete all as specified and as directed at site.
Supply and fix pin type porcelain, vitreous white , brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height , 150 mm dia for 11000 volts grade complete including taking down complete all as specified and as directed.
Restringing only ACSR conductor of any type/ size on existing LT/ HT poles, etc including binding on to insulators with and including aluminium wire complete all as directed.
M & L for cross arms , brasings, supports, clamps, and back plate fabricated from structural steel sections including nuts, bolts, washers, weldings, bending cold or hot drilled holes for bolts of any shape or size as indicated or directed including of one primer coat, one under coat and one finishing coat of paint including dismantling of existing.
M & L for fixing of PVC 3/4 way spacers on OH lines between two conductors complete all as specified and as directed.
M/S. OM ENTERPRISES
Om Construction
M/S. Niksun Electro-Infra Private Limited
M/S VR Construction Services
Adinath Technical Services
Mahindra Electric Stores
CHAITANYA WINDWELL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .