Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹10.3 LAdmitted-Finance | -15.15% | ₹10.3 L | L1 | Admitted-Finance |
| 2 | L2₹11.2 L+₹87,756.11 (8.53%)Admitted-Finance | -7.91% | ₹11.2 L+₹87,756.11 (8.53%) | L2 | Admitted-Finance |
| 3 | L3₹11.3 L+₹1.0 L (9.86%)Admitted-Finance | -6.78% | ₹11.3 L+₹1.0 L (9.86%) | L3 | Admitted-Finance |
| 4 | L4₹13.3 L+₹3.0 L (29.4%)Admitted-Finance | +9.79% | ₹13.3 L+₹3.0 L (29.4%) | L4 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | - | Rejected-Technical Digital electric Licence Not Enclosed |
Tender Value
₹12.1 L
EMD Value
₹24,240
Closing Date
24 Apr 2026, 6:00 pmClosed
EXECUTIVE ENGINEER
EE PWD Electric Dn Bikaner
SUGANI DEVI JESRAJ BED HOSPITAL AND RESEARCH CENTER INSTALLATION OF SOLAR PLANT IN BIKANER ( Electrical Work)
2026_CEPWD_551679_1
E NIT 02/2026-27 EE PWD Electric Dn Bikaner
Open Tender
Electrical Works
Percentage
60 days
Bikaner
Please refer tender document
2 documents required · 2 mandatory
₹500
Through Online E-Grass Challan BKN Office ID 4934
₹24,240
Yes
EE PWD Electric Dn Bikaner
12 Jul 2026
14 Apr 2026
27 Apr 2026
14 Apr 2026
24 Apr 2026
14 Apr 2026
14 Apr 2026 - 24 Apr 2026
20 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SITC of Grid interactive Solar Photovoltaic Power Plant of required capacity having specifications as per A, B, C, D, E, F and G | - | - | - | - |
| 2 | A. Solar Photovoltaic module : MNRE approved and ALMM listed, SPV module of capacity 580 Wp or above, Anodized Aluminium Alloy Framed Topcon N- type Bifacial, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. , 2 mm Low Iron ARC semi-tempered glass, IP-68 PPL Junction box, 4.0 sq.mm cable with MC4 solar connector, conversion efficiency shall not be less than 21.0 % on STC, performance warranty for their output peak watt capacity > 90 % at the end of 10 years and > 80% at the end of 25 years. | - | - | - | - |
| 3 | B. Inverter / PCU : MPPT integrated, IGBT/MOSFET based and microprocessor/ DSP controlled Power Conditioning Unit (PCU) of AC nominal power output rating equal or greater than the required KWp of the module in IP-65 Enclosure, of 250-1500 V DC Input voltage range and 400 V AC, TPN, 50Hz +/- 2.5 Hz, Efficiency > 97%, THD < 3%, Overloading capacity > / = 10%, remote monitoring facility and PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. | - | - | - | - |
| 4 | C. Module mounting structure : MMS Steel shall be as per latest IS 2062:2011 and galvanization of the mounting structure shall be in compliance of latest IS 4759, All bolts, nuts, fasteners shall be hot dip galvanized, MMS shall be designed and installed to withstand the speed for the wind zone of the location with factor of safety >1.5, STAAD report of structure to be submitted | - | - | - | - |
| 5 | D. Array Junction Box / DCDB : IP 65 AJB / Enclosure mounted on MMS with Polyamide glands and MC4 Connectors and cable ferrules for identification. DC fuses with SPD type-II/MOV type surge arrester to be provided. | - | - | - | - |
| 6 | E. ACDB : IP 65 ACDB / Enclosure mounted on MMS with Polyamide glands and MC4 Connectors and cable ferrules for identification. MCB/MCCB with SPD type-II/MOV type surge arrester to be provided. | - | - | - | - |
| 7 | F. Earthing and Lightning protection: The entire space occupying the SPV array shall be suitably protected against Lightning by deploying required number of Lightning Arrestors (LAs). as per NFC17-102:2011/IEC 62305 standard and three no. of Earthing with suitable size earth conductor | - | - | - | - |
| 8 | G. Solar meter and Cable : Laying of array cables to PCU/ DCDB unit along with supplying & fixing of necessary GI raceways/MS conduit lugs and suitable size aluminium armoured cable from ACDB to Electrical panel (up to 50 Mtr.) Discom approved solar meter (Direct or CT operated) with suitable size IP65 enclosure or MIP Box with CT | - | - | - | - |
| 9 | 25 KWp | 1 | Set | 12,12,101 | ₹12,12,101 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
BOQ_983215.xls
BOQ • 0.93 MB
Newtermandconditiion.pdf
Tender Documents • 4.68 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .