| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹10.1 L+₹30,520 (3.11%)Rejected-AOC HOUSE NO 22 BHAGADUTTAPUR BELTOLA RUKMINIGAON ROAD GUWAHATI 781028 | KAMRUP METRO | ASSAM | 781028 | L2 | Rejected-AOC OK | |
| 3 | L3₹10.5 L+₹69,970 (7.13%)Rejected-AOC | L3 | Rejected-AOC OK |
Tender Value
₹9.2 L
EMD Value
₹18,400
Closing Date
12 Dec 2019, 6:00 pmClosed
AGE (I) AF Digaru
AGE (I) AF Digaru PO Digaru Dist Kamrup Assam 782401
Repair/Maint of switch gear, FLP fitting and other misc works at TP Complex AFS Digaru.
2019_MES_301461_1
8338/E8 of 2019-20
Open Tender
Miscellaneous Works
Item Rate
180 days
DIG
MES contractor enlisted as class E cat b (i) having deposited standing security of Rs 50,000 with dept.
5 documents required · 5 mandatory
₹500
Yes
AGE (I) AF Digaru
₹18,400
Yes
17 Feb 2020
27 Nov 2019
14 Dec 2019
27 Nov 2019
12 Dec 2019
2 Dec 2019
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc
Material and Labour point wiring with FRLS PVC insulated unsheathed, stranded copper conductor single core 1.5 Sqmm cable for one light point controlled by one one way in PVC Cassing capping with all accessories, junction box etc incl one FRLS PVC insulated, un sheathed Single core stranded/solid copper conductor cable of size 1.0 Sqmm for continues earth wire connected to main earth dolly , including matching the disturbed surface with cement work and white washing/colour washing/distembering to match the disturbed surfaces complete all as directed by Engr -in Charge.
One light/fan point controlled by one switch.
3 pin 5 amps socket outlet on independent board.
All as per item No 2 above but with cables of size 2.5 sqmm for phase,neutral and 1.5 sqmm for earthing for 3 pin 15 amps socket outlet on ind board.
M & L modular switch 1 way 6 amps 1 module complete all as directed (Make: MK/Havells/schneider)
M & L modular switch 1 way 16 amps 1 module (Make :MK/Havells/schneider)
M & L modular socket 6 amps 3 pin complete all as directed. (Make : MK/Havells/schneider)
M & L modular socket 6/16 amps 5 pin complete all as directed. (Make : MK/Havells/schneider)
Taking down unserviceable Flame proof light fitting of any type any size and any capacity from its existing position after disconnecting all electrical connection.
Material and Labour point wiring concelled for flame proof fitting with FRLS PVC insulated unsheathed, stranded copper conductor single core 2.5 Sqmm cable for one light point controlled by one one way flame proof switch, drawn in and including heavy duty ERW steel conduit pipe of dia ( 20mm) complete with all flame proof fitting accessories, junction box etc incl one FRLS PVC insulated, un sheathed Single core stranded/solid copper conductor cable of size 1.5 Sqmm for continues earth wire connected to main earth dolly , including matching the disturbed surface with cement work and white washing/colour washing/distembering to match the disturbed surfaces complete all as directed by Engr -in Charge.
Supply and fix Flame proof -weather proof LED fluorescent fixture 2x20W with tube rod.Cat No-EXTN2LT8-16/20. (Make :Havells/Crompton or equvilent as approved by E-in-Cs) .
Supply and fixing Flame proof -weather proof switch /isolator 10/16 amp single pole ON/OFF.
Taking down unserviceable DB of any capacity
Taking down unserviceable MCB SP SPN.TPN of any capacity .
Supply and fixing of MCB SPN DB 8 way made of sheet steel phos phatised, powder painted with bus bar, neutral link, earth bar and Din rail ,230 Volts with Double door.(Make : Legrand /L&T/Schiender/ Indoasian/Havells/Standard)
Supply fixing, connection and testing MCB SPN 240 Volts, 'B' series, breaking capacity 10 KA of rating 40- 63 Amps.(Make : Legrand /L&T/Schiender/ Indoasian/Havells/Standard)
Supply fixing, connecting and testing MCB SP 6-32 Amps (Make : Legrand /L&T/Schiender/ Indoasian / Havells/ Standard)
Disconnecting and taking down surface mounted/flush mounted defective light fitting of any type from wall/ceiling complete all as directed.
S & F LED light fitting with tube 2x18 watt T8 LED tube surface mounting IP65 industrial type luminaires complete including LED tubes , single side connection complete all as directed. Cat No LHFKAWN2TC6J018 Make : Havells or equv model of Bajaj/Wipro.
S & F in repairs LED tube rod 28 watt capacity suitable for fixing in existing T5 fittings complete all as directed. Cat No LHLDCNVENL8Z018 Make Havells or equv model of Bajaj/Wipro
M & L LED tube light fitting with tube comprising of batten and LED tube light 18 watt capacity for batten and 112066 for LED tube light of (Make: Bajaj Havells/CG)
S & F in repairs LED tube rod 18 watt capacity suitable for fixing in existing T5 fittings complete all as directed. (Make : Havells/Bajaj/Wiproor or equivalent)
Supply and fixing electronic chowk for LED light fitting of cap 18 Watt.
Supply and fixing electronic chowk for LED light fitting of cap 28 Watt.
Taking down unserviceable Flame proof light fitting of any type any size and any capacity from its existing position after disconnecting all electrical connection and replacement of the following items as under-
Supply and fixing in replacement of HPSV Lamp of capacity 70 Watt. (Make: BAJAJ/CROMPTION GREAVES/Havells).
All as Per items No 25 of cap 150W .
All as Per items No 25 of cap 250W .
All as per item No 25 here in before but ignitor 70 W (Make : BAJAJ/CROMPTION GREAVES/Havells).
All as per item No 25 here in before but ignitor 150 W (Make : BAJAJ / CROMPTION GREAVES/ Havells).
All as per item No 25 here in before but ignitor 150 W (Make : BAJAJ/CROMPTION GREAVES/Havells).
All as per item No 25 here in before but bulb Holder threaded of cap 70 W
All as per item No 25 here in before but bulb Holder threaded of cap 150 W
All as per item No 25 here in before but bulb Holder threaded of cap 250W
Supply and fixing in replacement of copper chowk ballast of capacity 70 Watt. (Make :- BAJAJ / CROMPTION GREAVES/ Havells).
All as per item No 34 here in before but of cap 150 W (Make : BAJAJ / CROMPTION GREAVES/ Havells).
All as per item No34 here in before but of cap 250 W (Make : BAJAJ / CROMPTION GREAVES/ Havells).
Supply and fixing in replacement of ignator of capacity 10 MFD suitable for 70/150 W fitting.(Make :- BAJAJ/ CROMPTION GREAVES/Havells).
All as per items No 37 of ignator of cap 33 MFD suitable for 250 W Supply and fixing in replacement of ignator of capacity 10 MFD suitable for 75 W fitting. (Make: BAJAJ/CROMPTION GREAVES/Havells)
Taking out U/S LED floodlight and supply and fixing with new luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP 66 complete 100 watt capacity. WIPRO or equv in CG/Havells incl fixing and making electric connections and testing for proper working all as directed.
M & L for repairing/servicing of electrically operated shutter operating mechanism at parking/storage areas complete for both electrical as well as manual operation of the shutters, by checking/repairing of all the parts/systems, cleaning and tightening of all contacts & electrical connections, oiling/lubrication of the gears, bearing & chains etc, checking and properly tightening of all the hardwares, replacing worn out / rusted nuts/bolts/washers etc with new one, checking and setting the mountings for proper alighnment and for smooth/trouble free opening/closing of the shutters, checking insulation value of the motor and testing the sysytem for automatic (electric motor mode) and manual operation for trouble free opening and closing of the shutters all as directed.
Disconnecting and taking down the defective ceiling fan 1200 mm sweep and refixing the same at the original postion after repairs incl supply and fixing safety/locking split pins, making electrical connections and testing for proper working complete all as directed.
Disconnecting and taking down the defective exhaust fan 380 mm sweep and refixing the same at the original postion after repairs incl making electrical connections and testing for proper working complete all as directed.
Dismantling the fan motor, taking out burnt out windings,bearings etc cleaning the slots and rewinding with super enamelled copper winding wire as per existing gauge incl all insulating materials, reassembling and testing for proper working complete all as directed for the following:-
1200 mm sweep ceiling fan.
380 mm sweep exhaust fan
S & F fan capacitor 2.5 mfd complete all as directed. Make: Bajaj/CG/Havells
S & F ball bearing suitable for 380 mm sweep exhaust fan.
S & F ball bearing suitable for 1200 mm sweep ceiling fan.
S & F in repair RCCB 4pole 415 volt 63 amp complete all as directed.
Taking out following old U/S MCB from DB and replacement with new all as specified and directed :-
Supply only MCB SP 6-20 AMP.
Supply only MCB SPN 20-32 AMP.
Supply only MCB TPN 20-32 AMP.
M/S B.H. ENTERPRISE
M/S TRADE CENTRE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .