Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-Finance | L1 | Accepted-Finance Admitted | |
| 2 | Not Admitted-Finance | - | Not Admitted-Finance Not qualified for AOC | |
| 3 | Not Admitted-Finance | - | Not Admitted-Finance Not qualified for AOC |
| Sl No | Description | Qty | Unit | Hinduja Asphalt Cropration L1 |
|---|---|---|---|---|
| 1.001) The estimated amount is inclusive of GST. 2) The Bidder should quote basic rates exclusive of GST and quote GST percentage separately. GST should be revised from time to time. | ||||
| 2.00 | I. Exterior Expansion Joint Treatment for horizontal area - a) Chipping:- Removal of existing concrete upto mother slab and disposal of concrete generated debries from terrace to dumpyard | 35 | Rft | 2,206 ₹77,210 Lowest |
| 3.00 | 2 Exterior Expansion Joint Treatment:- a)Making 25mm groove using Levelling chemical Mortar/ Polymer mortar b)Fixing the Backer rod of 40/50 mm dia c)Filling the Groove with PU Sealant size; 40mm X 15mm | 35 | Rft | 5,514 ₹1,92,990 Lowest |
| 4.003 Application Water Guard:- a) Application of one coat of Water Guard Acrylic polymer modified cementious slurry coating over the RCC mother slab surface after saturating the surface with water and continuing the coating upto the width of 400 mm b) Laying Fleece over the Water Guard applied surface when the coating is still green c) Fixing the Backer rod of 40/50 mm dia d) Application of second coat of WATER GUARD – Acrylic Polymer Modified cementitious Brush Topping over the Fleece cloth laid surface 4 Concrete M25 Grade:-Re-concretting the Chipping width of 500 mm with M25 Grade Concrete by leaving Groove of 25mm/RMC/ MANUAL MIX to match exisint flooring. 5 PU Sealent:-a)Fixing the Backer rod of 25 mm dia b)Filling the Groove with PU Sealant size; 25mm X 12mm c) Finally entire surface shall be finished with APP membrance of 3mm thick i)Cleaning of surface thoroughly ii)Application of Primer iii)Laying of 3 mm thick APP Modified bitumen based water proofing membrane Aluminium paint shall be coated | ||||
| 5.00 | II. Exterior Expansion Joint Treatment for vertical area:- a)Removal of damaged portion from the groove b) Making 25mm groove using Levelling chemical Mortar/ Polymer mortar c) Fixing the Backer rod of 40/50 mm dia d)Filling the Groove with PU Sealant size; 25mm X 15mm Application Water Guard:- i) Application of one coat of Water Guard Acrylic polymer modified cementious slurry coating over the RCC mother slab surface after saturating the surface with water and continuing the coating upto the width of 400 mm ii) Laying Fleece over the Water Guard applied surface when the coating is still green iii) Application of second coat of WATER GUARD – Acrylic Polymer Modified cementitious Brush Topping over the Fleece cloth laid surface | 165 | Rft | 3,309 ₹5,45,985 Lowest |
| 6.00 | 3. Interior Expansion Joint covering with aluminium profile (100mm x 2mm)Supply and application: joint cleaning, edge correction, protection with 2mm aluminium plate anchored on one side and slotted on other side as per the specification. | 200 | Rft | 1,103 ₹2,20,600 Lowest |
| 7.00 | 4. Scaffolding to carry above works | 2,500 | Sft | 34 ₹85,000 Lowest |
| 8.00 | 5. Damaged brick wall repairs – providing clay brick masonry using clay bricks | 35 | Cft | 331 ₹11,585 Lowest |
Tender Value
₹13.9 L
EMD Value
₹27,862
Closing Date
14 Oct 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer A/C
UWD, Admin Bldg, UoH, Gachibowli, Hyd 500046
Expansion joints Interior and exterior Ladies Hostel I in UoH campus
2026_UoH_929272_1
UH/ENGG/UWD/2026-27/20
Open Tender
Civil Works
Item Rate
90 days
University of Hyderabad, Hyderabad
Please refer as per tender document
7 documents required · 7 mandatory
₹0
₹27,862
Yes
6 Nov 2026
8 Oct 2026
15 Oct 2026
8 Oct 2026
14 Oct 2026
8 Oct 2026
8 Oct 2026 - 14 Oct 2026
90 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | 1) The estimated amount is inclusive of GST. 2) The Bidder should quote basic rates exclusive of GST and quote GST percentage separately. GST should be revised from time to time. | - | - | - | - |
| 2 | I. Exterior Expansion Joint Treatment for horizontal area - a) Chipping:- Removal of existing concrete upto mother slab and disposal of concrete generated debries from terrace to dumpyard | 35 | Rft | - | - |
| 3 | 2 Exterior Expansion Joint Treatment:- a)Making 25mm groove using Levelling chemical Mortar/ Polymer mortar b)Fixing the Backer rod of 40/50 mm dia c)Filling the Groove with PU Sealant size; 40mm X 15mm | 35 | Rft | - | - |
| 4 | 3 Application Water Guard:- a) Application of one coat of Water Guard Acrylic polymer modified cementious slurry coating over the RCC mother slab surface after saturating the surface with water and continuing the coating upto the width of 400 mm b) Laying Fleece over the Water Guard applied surface when the coating is still green c) Fixing the Backer rod of 40/50 mm dia d) Application of second coat of WATER GUARD – Acrylic Polymer Modified cementitious Brush Topping over the Fleece cloth laid surface 4 Concrete M25 Grade:-Re-concretting the Chipping width of 500 mm with M25 Grade Concrete by leaving Groove of 25mm/RMC/ MANUAL MIX to match exisint flooring. 5 PU Sealent:-a)Fixing the Backer rod of 25 mm dia b)Filling the Groove with PU Sealant size; 25mm X 12mm c) Finally entire surface shall be finished with APP membrance of 3mm thick i)Cleaning of surface thoroughly ii)Application of Primer iii)Laying of 3 mm thick APP Modified bitumen based water proofing membrane Aluminium paint shall be coated | - | - | - | - |
| 5 | II. Exterior Expansion Joint Treatment for vertical area:- a)Removal of damaged portion from the groove b) Making 25mm groove using Levelling chemical Mortar/ Polymer mortar c) Fixing the Backer rod of 40/50 mm dia d)Filling the Groove with PU Sealant size; 25mm X 15mm Application Water Guard:- i) Application of one coat of Water Guard Acrylic polymer modified cementious slurry coating over the RCC mother slab surface after saturating the surface with water and continuing the coating upto the width of 400 mm ii) Laying Fleece over the Water Guard applied surface when the coating is still green iii) Application of second coat of WATER GUARD – Acrylic Polymer Modified cementitious Brush Topping over the Fleece cloth laid surface | 165 | Rft | - | - |
| 6 | 3. Interior Expansion Joint covering with aluminium profile (100mm x 2mm)Supply and application: joint cleaning, edge correction, protection with 2mm aluminium plate anchored on one side and slotted on other side as per the specification. | 200 | Rft | - | - |
| 7 | 4. Scaffolding to carry above works | 2,500 | Sft | - | - |
| 8 | 5. Damaged brick wall repairs – providing clay brick masonry using clay bricks | 35 | Cft | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.76 MB
LHISEC.pdf
Tender Documents • 1.25 MB
BOQ_976735.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .