Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
4 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Shri. Shirish Sharma IDSE SE SAG
KALAIKUNDA
COMPREHENSIVE MAINTENANCE OF SOLAR PLANT, FIRE ALARM SYSTEM, EOT CRANES AND MISC NATURE OF WORKS AT AF STN SALUA UNDER GE AF KALAIKUNDA
2026_MES_798500_1
8818/KKD/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
CWE AF KALAIKUNDA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF KALAIKUNDA
₹60,000
Yes
13 Nov 2026
13 Nov 2026
5 Dec 2026
13 Nov 2026
4 Dec 2026
27 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive maintenance for 11 months of solar PV power plant with PV array capacity 500 KWP grid including cosisting of the following:-
Comprehensive maintenance of the solar PV power plant.
1) PV Modules cleaning and visual inspection of Cracked and broken modules;
2) Module interconnects tightness;
3) Connections of cable terminations in junction box;
4) Visual inspection of rodent attacks on cable conduits.;
5) Visual Inspection of junction box & combiner box enclosures;
6) Checking and tightening of structure hardwires;
7) Checking and tightening of post structure Rigidity;
8) Checking and tightening of system and protective earthing strips;
9) Checking and tightening of DC and AC terminations and inverters.
10) Checking electrical parameter of the installed power plant.
11) Replacement of batteries of the SCADA and other instruments;
12) Cleaning of vegetation to be done on daily basis/as required to maintain the entire solar complex free from vegetation growth
13) Any other job other than above indicated jobs would be covered. | 11 | Each Job | - | - |
| 2 | All as per item No 1 above but of roof top grid connected solar PV power plant with PV array capacity 30KWP grid. | 11 | Each job | - | - |
| 3 | Supply, fixing , testing and commissioning in repair/replacement of 30 KWp invertor set TRIO-TM-50.0-400 with AC wiring box, AC disconnect switch, AC surge protection (Type 2 with monitoring), to be assembled with dc wiring box, power module and mounting bracket, suitable and to be integrate with 500 KWp solar power plant complete with AC & DC wiring box as complete set as per sample, IP 65, integration with SCADA system and remote data collection using SCADA and Wi-Fi, including taking out of old U/S complete all as specified and directed. Make :- ABB or equivalent | 1 | Each | - | - |
| 4 | Supply only in replacement AC combiner box complete with safets fuses,MCBs,transite voltage surge supressor,array junction box including taking down of old U/S complete all as specified and directed by Engr-in-charge. | 1 | Each | - | - |
| 5 | Supply, fixing , testing and commissioning in repair/replacement of 50 KWp invertor set TRIO-TM-50.0-400 with AC wiring box, AC disconnect switch, AC surge protection (Type 2 with monitoring), to be assembled with dc wiring box, power module and mounting bracket, suitable and to be integrate with 500 KWp solar power plant complete with AC & DC wiring box as complete set as per sample, IP 65, integration with SCADA system and remote data collection using SCADA and Wi-Fi, including taking out of old U/S complete all as specified and directed. Make :- ABB or equivalent | 1 | Each | - | - |
| 6 | S&F 1core X 4 Sqmm size DC copper cables in replacement as per TUV 2Pfg 1169/08 2007 for inter connection between module to module ,DC junction box , Invertor,etc with supply of PVC conduit pipe or flexible PVC roll including taking down of old U/S cable as per site requirement and as directed by EIC | 665 | RM | - | - |
| 7 | Supply and fixing in replacement rigid non-metallic PVC conduit/flexible roll of size 20 mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.incl taking out of old U/S complete all as specified and as directed. | 380 | RM | - | - |
| 8 | Supply and fixing in replacement rigid non-metallic PVC conduit/flexible roll of size 25 mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. .incl taking out of old U/S complete all as specified and as directed. | 280 | RM | - | - |
| 9 | Supply, laying and testing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 3.5 core including taking out of old U/S cable complete alls as specified and directed | 900 | RM | - | - |
| 10 | Material and labour for 40 mm dia galvanized iron tube Medium grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, complete all as specified and directed including clamps, nut, bolt and washers in.incl taking out of old U/S complete all as specified and as directed. | 45 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
TDFINAL.pdf
Tender Documents • 0.84 MB
BOQ_895768.xls
BOQ • 1.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .