| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-AOC EAST VIVEKANANDA PALLY MANGAL PANDEY SARANI PO RABINDRA SARANI SILIGURI 734 006 WB | JALPAIGURI | WEST BENGAL | 734006 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹38.9 L+₹75,377 (1.98%)Rejected-Finance MAHANANDA PARA GOVT SAW MILL ROAD P O SILIGURI DIST JALPAIGURI WB | DARJEELING | WEST BENGAL | 734001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹39.4 L+₹1.3 L (3.28%)Rejected-Finance HAKIMPARA NEAR PAKURTALA MORE SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹39.6 L+₹1.4 L (3.77%)Rejected-Finance SIMULBARI T E PO VILL SIMULBARI PS KURSEONG DIST DARJEELING PIN 734009 WEST BENGAL | SIMULBARI | DARJEELING | WEST BENGAL | 734009 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹44.4 L+₹6.3 L (16.4%)Rejected-Finance ATUL PRASAD SARANI DUDH MORE SILIGURI 06 DARJEELING WB | DARJEELING | WEST BENGAL | 734001 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
25 Sept 2024, 6:00 pmClosed
Garrison Engineer Sukna
Garrison Engineer Sukna, Post-Simulbari, Dist.-Darjeeling, WB-734009
PERIODICAL SERVICES INTERNAL WIRING AND OTHER ALLIED WORKS AT U AREA UNDER AGE BR I OF GE SUKNA
2024_MES_669564_1
GE Sukna/8707
Open Tender
Civil Works
Works
270 days
Sukna
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹0
₹90,000
Yes
5 Nov 2024
4 Sept 2024
27 Sept 2024
4 Sept 2024
25 Sept 2024
18 Sept 2024
4 Sept 2024 - 25 Sept 2024
Amount
Supply only liquid water proofing compound complete all as specified.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L Rendering 15 mm thick on fair faces of brick work or concrete sur-faces in cement mortar 1:4 using water proofing compound @ 3% by wt of cement for finished even and smooth (without using extra cement) complete all as specified and directed. (WPC will be measured and paid separately)and directed.
M&L preparation of old decorated wall surface and including applying one coat of cement base paint complete all as specified and directed.
M&L preparation of old decorated wall surface and including applying one coat of oil bound distemper complete all as specified and directed.
M&L for prepration of new plastered surfaces of wall and applying two coat of oil bound distemper over a coat of primer over a thin layer of wall care putty on wall surfaces complete all as specified and directed.
M&L complete removal of existing treatment of old decorated surfaces of wall and applying two coat of oil emulsion distemper over a coat of alkali resistant cement primer over a thin layer of wall care putty to obtained smoothness of plastered surfaces complete all as specified and directed.
M&L preparation of old decorated ceiling surface and including applying one coat of oil bound distemper complete all as specified and directed.
M&L preparation of old decorated wooden surfaces of any description, not otherwise described over 10 cm width or girth and including applying one coats of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coats of synthetic enamel paint complete all as specified and directed.
M&L complete removal of existing treatment of old decorated wall surfaces and including applying two coats of weather coat acrylic exterior emulsion paint over a coat of primer complete all as specified and directed. Note : Rate shall be included for necessary scaffolding and safety arrangement.
M&L for repair to broken/damaged RCC chajjas by making good with PCC 1:2:4 type B1 or rendering 15 mm thick in cement mortar 1:4 mixed with water proofing compound to top and sides and rendering 5 mm thick to soffits in cement mortar 1:3 including necessary form work, reinforcement duly welded if required including demolition of broken/loose PCC or taking down old plaster at any storey of building complete all as specified and as directed.
M&L writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high with synthetic enamel paint complete all as specified and directed.
M&L preparation of old painted surfaces of CGI / PGI sheets in roof and including applying one coat of anti corrosive paint complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall by Vacuum based sanding machine, applying one coat of primer using auto roller and applying a thin layer of thick wall care putty and sanding the same by Vacuum based sanding machine till obtaining even and smooth finish and applying two coats of oil bound distemper by auto roller complete all as specified and directed as per manufacturers instructions. Note:-Multipurpose mixer shall be used for uniform and proper mixing of putty.
M&L for preparation of newly plastered surfaces of wall by Vacuum based sanding machine, applying one coat of primer using auto roller and applying a thin layer of thick wall care putty and sanding the same by Vacuum based sanding machine till obtaining even and smooth finish and applying two coats of exterior weather coat paint using auto roller complete all as specified and directed as per manufacturers instructions. Note:-Multipurpose mixer shall be used for uniform and proper mixing of putty.
M&L for complete removal of existing treatment of old decorated wall surfaces by Vacuum based sanding machine, removal of nails etc & filling cracks / hole with putty, applying one coat of primer using auto roller and applying a thin layer of wall care putty and sanding the same by Vacuum based sanding machine till obtaining even and smooth finish and applying two coats of oil bound distemper by auto roller complete all as specified and directed as per manufacturers instructions. Note:-Multipurpose mixer shall be used for uniform and proper mixing of putty.
M&L for complete removal of existing treatment of old decorated wall surfaces by washing with jet washer machine, removal of nails etc & filling cracks / hole with putty, applying one coat of primer using auto roller and applying a thin layer of thick wall care putty and sanding the same by Vacuum based sanding machine till obtaining even and smooth finish and applying two coats of exterior weather coat paint using auto roller complete all as specified and directed as per manufacturers instructions. Note:-Multipurpose mixer shall be used for uniform and proper mixing of putty.
M&L for point wiring for light points / fan points controlled by one, one way switch with (FRLSH) PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including , PVC medium grade Concealed conduit not less than 20 mm dia with sheet metal boxes concealed fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch, in wall with cast suitable for housing modular accessories & all necessary wall cutting and making good disturbed surface including taking down complete all as specified and as directed. (Note- (i) Making good to match with the adjoining surface shall be included in the unit rate. (ii) Cutting chases shall be included in the unit rate.)
All as per Sl. item No. 20.00 above but for one 5 / 6 Amps socket outlet point on same board.
All as per Sl. item No. 20 above but for one 5 / 6 Amps socket outlet point on independent board.
All as per Sl. item No. 20 above but for one light point controlled by two, 2 - way switches.
All as per SI. Item No 20 above but using pvc insulated unsheathed 2.5 sqmm cross sectional area cable for phase/ neutral & for earth 1.5 Sq mm green PVC insulated cable for 15 Amps socket point on independent board controlled by one switcch.
M&L point wiring with 1.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including PVC casing caping (double lock pattern) and accessories on wall / ceiling surfaces etc. with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc including all other fixing accessories for one light / fan / exhaust fan point controlled by one 5 / 6 Amps switch including taking down complete all as specified and directed.
All as per Sl. item No. 25.00 above but for one 5 / 6 Amps socket outlet point on same board.
All as per Sl. item No. 25 above but for one 5 / 6 Amps socket outlet point on independent board.
All as per Sl. item No. 25 above but for one 16 Amps socket outlet point on independent board with 2.5 sqmm cable and 2.5 sqmm earth wire.
All as per Sl. item No. 25 above but for one light point controlled by two, 2 - way switches.
S&F in repair switch piano modular type one way, 5 / 6 Amps, 240 volt complete all as specified and directed.
S & F in repair Socket outlet modular type 6 Amps 5 pin flush type complete all as specified and as directed.
S & F in repair modular type Socket outlet 16 Amps 6 pin combined 2 module complete all as specified and as directed.
S&F in repair modular type Bell push, flush type, 6 Amps single pole complete all as specified and as directed.
S & F in repair modular type switch 6 Amps single pole two way one module all as specified and as directed.
S & F in repair modular type switch 16 Amps single pole one way one module all as specified and as directed.
S&F in repair switch piano flush type one way single pole, 5 / 6 Amps, 230 volt complete all as specified and directed.
S&F in repair switch piano flush type two way, 5 / 6 Amps, 230 volt complete all as specified and directed.
S&F in repair socket outlet 5 pin 5 / 6 Amps, 230 volts complete all as specified and directed.
S&F in repair switch piano flush type one way single pole , 15 / 16 Amps, 240 volt complete all as specified and directed.
S&F socket outlet flush type 2 in 1, 3 pin, 15 Amps, 230 volts complete all as specified and directed.
S&F in repair Bell push, flush type, 6 Amps single pole complete all as specified and as directed.
S & F in repair for 100mm x 100mm x 50mm deep PVC rectangular block for mounting switches, sockets, regulators etc with including 2.8 mm thick plastic laminated white sheet cover complete all as specified and directed.
All as per Sl. item No.42 above but 175mm x 100mm x 50mm deep.
All as per Sl. item No.42 above but 200mm x 150mm x 50mm deep.
All as per Sl. item No.42 above but 250mm x 200mm x 50mm deep.
All as per Sl. item No.42 above but 350mm x 300mm x 50mm deep.
S&F in repair ceiling rose, surface bakelite 65 x 50 mm three terminal complete all as specified and directed.
S&F in repair lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings including taking down complete all as specified and as directed.
S&F in repair modular type stepped electronic fan regulator two module, flush type with 5 step, AC 50 Hz 240 Volts grade, 450W, complete all as specified and directed.
S&F in repair stepped type electronic fan regulator two module, flush type with 5 step, AC 50 Hz 240 Volts grade, 100 W, complete all as specified and directed.
S &F in repair Bell buzzer, Ding Dong AC. 230 volts, single pole completed as directed.
S&F in repair call bell, ding dong, AC 230 V, single pole complete all as specified and directed.
S&F in repair call bell, multi tune, single pole, AC 240 V complete all as specified and directed.
M&L Sub main wiring power/circuit using FRLS, PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 2.5 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through and including PVC conduit 20mm dia medium Grade Concealed in walls/roof/floors complete all as specified and as directed. (Note : (i) Two single core wires of 2.5 Sqmm and one wire of 2.5 Sqmm and one run of PVC conduit shall be measured as one unit). Make-Finolex/KEI/ Polycab. (ii) The unit rate included for making good the disturbed surface including finishes to match with the adjoining surfaces alongwith cutting chases) .
All as per item No. 54 but 2 Single core of size 4 Sqmm and earth continuity conductor of size 4 Sqmm complete all as specified and as directed.
All as per item No. 54 but 2 Single core of size 6 Sqmm and earth continuity conductor of size 6 Sqmm complete all as specified and as directed.
All as per item No. 54 but 4 Single core of size 10 Sqmm and earth continuity conductor of size 10 Sqmm complete all as specified and as directed.
S&F in repairs LED battery backup inverter bulb of Lamp wattage: - 9 to 12 Watts, Battery: - Not less than 2200mAh or not less than 4 hrs backup,Efficeacy: - Not less than 110 Lm/Watt including taking down old unsv ones complete all as specified and directed.
S & F in repairs Surface and wall mounted LED batten 20 watt 4ft long with Aluminum extruded housing , high quality polycarbonate diffuser & integrated Electronic Driver with IP20, PF 0.90, Efficiency not less than 110 lm/W color temp 6500k CRI ≥ 80, Operating Voltage range 140 V - 270 V complete all as specified and as directed.
S&F LED batten light fitting 1 x 10 watt inverter (backup) type, 230 Volts, suitable for surface mounting, lithium ion battery with minimum 4 hrs backup time, extruded polycarbonate housing & extruded polycarbonate diffuser, lumen efficacy 100 Lm/watt (minimum), colour temperature 6500K (minimum), CRI 80 (minimum), IP-20 (minimum), PF 0.90 (minimum), in-built surge protection 3.5 KV (minimum) inlcuding all fixing arragnement and electrically connecting from ceiling rose to light fitting & taking down complete all as specified and directed.
S&F in repairs LED Bulk Head fitting 10 watt with Injection molded polycarbonate housing IP66, IK10, 3.5kV inbuilt surge protection, PF ≥0.95, total System Lumens not less than 1100 lm, 6500k CRI ≥ 80, Operating Voltage range 140 V - 270 V. complete all as specified and directed.
S & F in repair LED Street Light 25 watt made up of pressure die cast aluminiun housing with highly efficient LEDs and PC cover with integrated lens with IP66, IK07, System Lumen Efficasy ≥100 Lm/W, 5 kV Surge Voltage Protection,Operating Voltage range 140 V - 270 V and bracket suitable for street light made out of GI pipe light grade of 25 mm bore & 0.75 mtr length (minimum), bend to shape including 2 pairs of MS flat iron clamps made out of 40 x 5 mm MS flat, nuts, bolts & washers etc, & painting the bracket with two coat of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
S & F in repair recessed Mounted Round LED Downlighter 15 watt having slim edge with die cast aluminium housing finished in premium white powder coating & PC Opal diffuser with integral Electronic LED Driver. IP20, PF ≥0.95, total System Lumens Efficiency not less than 110 lm/W and color temp 5700k CRI ≥ 80, Operating Voltage range 140 V - 270 V. complete all as specified and as directed.
S & F in repair Surface Mounted Round LED Downlighter 15 watt having slim edge with die cast aluminium housing finished in premium white powder coating & PC Opal diffuser with integral Electronic LED Driver. IP20, PF ≥0.95, total System Lumens Efficiency not less than 120 lm/W and color temp 5700k CRI ≥ 80, Operating Voltage range 140 V - 270 V. complete all as specified and as directed.
S&F in repair Recessed Mounted Square (2'x2') LED Panel light 36 watt suitable for mounting with Armstrong/Grid ceiling with CRCA powder coated housing & high transmittance Opal diffuser for glare free with Electronic LED Driver. IP20, PF ≥0.95, System Lumens ≥120 lm/W, 5700k CRI ≥ 80, Operating Voltage range 140 V - 270 V.complete all as specified and directed.
S&F in repair VTPN DB, 4 way, IP-43, IK 09, double door type with metal door, with 250 A copper neutral and earth bus bar, suitable for fixing upto 160 Amp MCCBs as incomer fixing DPX 250+12 flush to wall & making good the disturbed surfaces and including taking down old unsv ones complete all as specified and as directed.
S&F in repair MCB DB, TPN 4 way, IP-43, IK 09, double door type with metal door, with 100A copper neutral and earth bus bar for fixing MCB, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed.
S&F MCCB 4 pole 125 Amps breaking capacity 25 KA, Ics = 100% Icu including spreader link and taking down complete all as specified and directed.
S&F MCB TPN 40 to 63 Amp, 10 kA, 240V 'C' curve complete all as specified and as directed.
S&F MCB ,SPN DB, 8 ways double door, Metal door, IP-43 IK 09 in 100A rated bus bars,earth bar,neutral links complete incl. blanking plates as required & fixed flush to wall and making good the disturbed surfaces including dismantling taking down unsvericeable ones complete all as specified and directed.
S&F MCB, SPN DB, 12 ways double door, Metal door, IP-43 IK 09 in 100A rated bus bars,earth bar,neutral links complete incl. blanking plates as required & fixed flush to wall and making good the disturbed surfaces including dismantling taking down unsvericeable ones complete all as specified and directed.
S&F MCB SPN 40 Amp, 10 kA, 240V 'C' curve including dismantling taking down unsvericeable ones complete all as specified and as directed.
S&F MCB SP 6 to 32 Amp, 10 kA, 240V 'C' curve including dismantling taking down unsvericeable ones complete all as specified and as directed complete all as specified and directed.
S&F GI tubing light grade 40 mm dia for protection pipe along the wall to TPN DB for protection of cable including taking down old unsv ones complete all as specified and directed.
S&F in repair Metal Plug Socket DB with sheet metal enclosures with two pin and earth plug and socket one double pole MCB 20 Amps,240V for Geysor connenction complete all as specified and as directed.
S&F Exhaust fan 300 mm sweep, colour grey, heavy duty, metal body, 1400 RPM (minimum), AC single phase, 230 V, 50Hz along with louwer Shutter / bird guard, nuts, screws, bolts including electrical connection, writing MES number in 2 cm height with synthetic enamel paint and cutting wall for making hole and making good the disturbed surface to match the existing surface complete all as specified and directed. (Note : The quoted rate is including for taking down and depositing old fan to MES store.)
S&F Exhaust fan 250 mm sweep, non metallic plastic body, AC single phase, 230 V, 50Hz with & including self closing louvers, nuts, screws, bolts of specified sizes, electrical connection with twisted three core PVC insulated unsheathed flexible cord of size 0.75 sqmm copper conductor from ceiling rose to exhaust fan and writing MES number in 2 cm height with synthetic enamel paint and cutting wall for making hole awriting MES number in 2 cm height with synthetic enamel paint and cutting wall for making hole and making good the disturbed surface to match the existing surface complete all as specified and directed. (Note : The quoted rate is including for taking down and depositing old fan to MES store).
M &L of Earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connected using galvanised iron earth lead wire 4 Sqmm as earthing electrode by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe (medium grade) and other end connected to earthing test point as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth up to a distance not exceeding 50 Mtr etc all as shown on electrical plate No. 5 of MES Schedule Part-I complete including testing on completion. On testing after completion if the desired earth resistance is not obtained the earthing will be made again by the contractor at no additional cost and including dimantling complete all as specified and directed.
S&F in repair switch socket combination 2 in 1, 3 Pin, 6 & 16 Amp, flush type 230 volts universal complete all as specified and directed.
All as per item No.79 but 3 pin 6 Amps complete all as specified and as directed.
S GUHA (BID ID -3110756)
SHRI N.DAS (BID ID -3110449)
R N SAH N CO (BID ID -3109570)
MS ESSCON (BID ID -3109545)
KARMIBRINDA (BID ID -3113010)
Embee associates (BID ID -3106822)
R N De (BID ID -3107365)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .