LEKAWADA PATIA CHILODA GANDHINAGAR 382042
DEMOLITION OF CERTAIN BUILDINGS AND RECONSTRUCTION OF SMQ AT SION AREA AT AF STN MUMBAI
2021_MES_481434_1
84186
Open Tender
Civil Works
540 days
SION AREA AT AF STATION MUMBAI
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹3,000
GE (AF) THANE
₹12.8 L
Yes
7 May 2022
13 Oct 2021
19 Mar 2022
13 Oct 2021
17 Mar 2022
4 Mar 2022
14 Oct 2021 - 8 Nov 2021
Amount
NOTE: Schedule ‘A’ Part I to XVI are under Ser No. 1.00 to 16.00. are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for BUILDINGS / STRUCTURES as listed in Sch 'A’ Part I.
Lump sum price worked out for DEMOLITION as listed in Sch 'A’ Part II.
Lump sum price worked out for EXCAVATION AND EARTH WORK as listed in Sch 'A’ Part III
Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch 'A’ Part IV
Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch 'A’ Part V
Lump sum price worked out for HARD STANDING/ PAVED AREA as listed in Sch 'A’ Part VI
Lump sum price worked out for AREA DRAINAGE as listed in Sch 'A’ Part VII
Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch 'A’ Part VIII
Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch 'A’ Part IX
Lump sum price worked out for STAND BY SUPPLY (DG SET) as listed in Sch 'A’ Part X
Lump sum price worked out for FIRE FIGHTING SYSTEM as listed in Sch 'A’ Part XI
Lump sum price worked out for LIFTS as listed in Sch 'A’ Part XII
Lump sum price worked out for COMPOUND WALL as listed in Sch 'A’ Part XIII
Lump sum price worked out for LIGHTENING PROTECTION as listed in Sch 'A’ Part XIV
Lump sum price worked out for AVIATION OBSTRUCTION LIGHT as listed in Sch 'A’ Part XV
Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch 'A’ Part XVI
16.01 SCHEDULE `A' PART-XVII MISCELLANEOUS ITEMS OF WORK (Note for items 17.00 to 60.00 The contractor shall quote his rate for each of these items separately. The estimated rate is left blank since the same is not prepriced by MES)
EXCAVATION & EARTHWORK
Removing excavated material or soil outside MD land depositing complete all as specified and as directed.
INTERNAL ELECTRIFICATION
Suppyling, installing, testing and commissioning of factory made Indoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system including bus bar chamber in centre ( vertically) and cable alley either side, outer shell shall be made out of 2 mm thick CRCA sheet duly powder coated coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitable to accomodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, inlcuding provision for taking out incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc including double compression type cable gland with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregates blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accesories with provision for glass for taking reading of KWH Meter without opening door complete all as specified and directed :-
OUTGOINGS (a) MCCB, 40 Amp, rating 4 Pole, 16 KA, 415 Volts -14 Nos (b) MCB SPN, 32 Amps, rating 2 Pole - 02 Nos (c) ISI Marked Digital tamper proof electronic SINGLE PHASE KWH Meter 10-60amp- 14 Nos Note :- Before procurement GA drawing shall be got approved from GE by the contractor.
LIFTS
Supply, installation, testing, commissioning, putting into operation and final testing of automatic lift (MRL Type) complete in the shaft well and pit constructed including automatic rescue device(ARD), all standard equipments, accessories and control equipments as per manufacturer design complete all as specified and directed conforming to NBC/Statutory norms and fulfilling the following requirements:-
(i) Type: Passenger lift (ii) Load: As specified elsewhere from 2 passenger to 8 Passenger (For each person standard weight 68 Kg) (iii) Speed: 1.50 Metre/Sec (iv) Control: ACV3F,32bit Microprocessor integrated serial communication control system with RMS(Remote Monitoring system)/BMS(Building monitoring system) supporting software (v) Motor/Machine: Permanent magnetic synchronous gearless motor (vi) Operation: Simplex full collective (vii) Total rise: Near about 48 Mtrs(Approx), 15 stops (G+14) only (viii) Landing: All floors on the same side (ix) Floor Served:G+14
(x) Signals: Digital car position indicator, car travel direction indicator inside car & at all landings, voice announciator with suitable music shall be provided in the lift car (xi) Guide rail: As per manufacturers specification (xiii) Lift and car size: As per manufacturers specification (xiv) Car door: Side sliding (xv) Car door: S.S (Stainless steel) Hairline finish centre/Telescopic opening door with vision panel (xvi) Landing door: S.S (Stainless steel) Hairline finish centre/ Telescopic opening door with vision panel
(xvii) Door Operation: Automatic electric power operated door, full height infra red curtain with multiple criss cross light beams (xviii) Car interior: S.S (Stainless steel) panel with hair line finish on all sides. (xix) Car floor: Anti skid PVC flooring on heavy duty MS (Mild steel) platform (xx) Car ceiling & lighting: S.S (Stainless steel) finish with aesthetic appearance with LED ceiling lights (xxi) Car Ventilation: Pressure fan/blower fan (Car fan with automatic sleep timer shall be provided) (xxii) Emergency lighting in car: Battery operated emergency lighting in the lift car (xxiii) Intercom system : battery operated Intercom system in lift car and ground floor/control room
(xiv) Emergency alarm: Battery operated alarm bell system in lift car &control room/ground floor. (xxv) Position of head room: Directly above the hoist-way (xxvi) Electric power supply: AC, 415V, 3phase, 50 Hz & AC, 230 V, 1 phase, 50 Hz, terminated in machine room (xxvii) Fire man switch: Fire man switch at machine room/terminal landing (xxviii) All car panel buttons and all floor switches must be with brail language as per lift act. (xxix) Audio visual indication in the lift car showing overloading shall be provided such that doors kept open till excess load removed. (xxx) Spring buffer/hydraulic buffers shall be provided.
(xxxi) Mechanical over speed governor, door key holes in the floor doors shall be provided. (xxxii) Lift machine hoisting arrangement in the lift head room and monkey ladder for lift pit should be provided by the lift agency, along with the other steel structure works, foundations for the machines etc. (xxxiii) In the hoist way fascia plate shall be provided. (xxxiv) Permanent writing in the lift head room and lift well with proper No. of light point, with fixtures, exhaust fan, plug point and 3 phase, 440V power supply shall be made available by the department in the lift shaft, head room or at desired level (xxxv) Car top safety barricade shall be provided.
(xxxvi) ARD (Automatic rescue device): Solid state inbuilt automatic rescue device (ARD) for automatic rescue passengers trapped in the lift car in between floors in the event of power failure.Automatic operation and immediate action in the event of mains failure capable to move the lift to the nearest landing, opens the automatic door of the lift car and floor. Sealed maintenance free battery backup with automatic charging unit and auto changeover device on main failure. Passenger Capacity (i) 8 Passenger (544Kg)
Note:- (i)Out of 02 Lift one lift will be used as fire lift and its specification will be as per fire lift specification issued by NBC and in normal circumstances all two lift will be used as passenger lift. (ii)Before placing order GA drawing and specification and make will be approved by Eng-in-Charge and GE. (iii) Shaft & pit size available as per drawings made part of tender.
Supply, installation, testing, commissioning, putting into operation and final testing of automatic lift (MRL Type) complete in the shaft well and pit constructed including automatic rescue device(ARD), all standard equipment, accessories and control equipment as per manufacturer design, complete all as specified and directed conforming to NBC/Statutory norms and fulfilling the following requirements:-
(i) Type: Passenger lift (ii) Load: As specified elsewhere from 2 passenger to 13 Passenger (884KGS) (iii) Speed:1.50 Meter/Sec (iv) Control: AC V3F, 32bit, Microprocessor, integrated serial communication control system, with RMS (Remote Monitoring system)/BMS (Building monitoring system) supporting software (v) Motor/Machine: Permanent magnetic synchronous gearless motor (vi) Operation: Simplex full collective (vii) Total rise: Near about 48 Mtrs (Approx) 15 stops(G+14) only (viii) Landing: All floors on the same side (ix) Floor Served: G+14
(x) Signals: Digital car position indicator, car travel direction indicator inside car & at all landings, voice annuciator with suitable music shall be provide in the lift car (xi) Guide rail: As per manufacturers specification (xiii) Lift and car size: As per manufacturers specification (xiv) Car entrance: As per manufacturers specification (xv) Car door: S.S (Stainless steel) Hairline finish centre/Telescopic opening door with vision panel (xvi) Landing door: S.S(Stainless steel) Hairline finish centre/ Telescopic opening door with vision panel (xvii) Door Operation: Automatic electric power operated door, full height infra red curtain with multiple criss cross light beams
(xviii) Car interior: S.S (Stainless steel) panel with hair line finish on all sides. (xix) Car floor: Anti skid PVC flooring on heavy duty MS (Mild steel) platform (xx) Car ceiling & lighting: S.S (Stainless steel) finish with aesthetic appearance with LED ceiling lights (xxi) Car Ventilation: Pressure fan/blower fan (Car fan with automatic sleep timer shall be provided) (xxii) Emergency lighting in car: Battery operated emergency lighting in the lift car (xxiii) Intercom system : battery operated Intercom system in lift car and ground floor/control room (xiv) Emergency alarm: Battery operated alaram bell system in lift car & control room/ground floor. (xxv) Position of head room: Directly above the hoist-way (xxvi) Electric power supply: AC, 415V, 3phase, 50 Hz & AC, 230 V, 1 phase, 50 Hz, terminated in machine room
(xxvii) Fire man switch: Fire man switch at machine room/terminal landing (xxviii) All car panel buttons and all floor switches must be with brail language as per lift act. (xxix) Audio visual indication in the lift car showing overloading shall be provided such that doors kept open till excess load removed. (xxx) Spring buffer/hydraulic buffers shall be provided. (xxxi) Mechanical over speed governor, door key holes in the floor doors shall be provided. (xxxii) Lift machine hoisting arrangement in the lift head room and monkey ladder for lift pit should be provided by the lift agency, along with the other steel structure works, foundations for the machines etc. (xxxiii) In the hoist way fascia plate shall be provided.
(xxxiv) Permanent writing in the lift head room and lift well with proper No. of light poins, with fixtures, exhaust fan, plug point and 3 phase, 440V power supply shall be made available by the department in the lift shaft, head room or at desired level (xxxv) Car top safety barricade shall be provided. (xxxvi) ARD (Automatic rescue device): Solid state inbuilt automatic rescue device (ARD) for automatic rescue passengers trapped in the lift car in between floors in the event of power failure. Automatic operation and immediate action in the event of mains failure capable to move the lift to the nearest landing, opens the automatic door of the lift car and floor. Sealed maintenance free battery backup with automatic charging unit and auto changeover device on main failure. Passenger Capacity (i) 13 Passenger (884Kg)
Note:- (i) Before placing order GA drawing and specification and make will be approved by Eng-in-Charge and GE. (ii) Shaft & pit size available as per drawings made part of tender.
STAND BY SUPPLY (DG SET)
Supply, erecting, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 160 KVA, water cooled, 415 Volts (AC Three phase, 4 Wire system of supply), 50 HZ, at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet , outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Kochi.
(Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation( of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB guidelines and Comprising of followings:-
(i) ENGINE(Prime Mover): Diesel Engine 1500 RPM, direct injection, 6 cylinders, four stroke, confirming to ISO3046/BS 5514, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 160 KVA at outdoor atmospheric conditions at Fort Kochi, (Taking all derating factor into consideration), 12/24 Volt (as per manufacturer recommendations) electric battery start, complete with fly wheel all standard fittings/ fixtures as per manufacturer and including suitable panel with techometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, High water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc complete all as specified and directed with the following:-
(ii) ALTERNATOR: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 200 KVA Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class "H", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine. (iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications. (iv) AMF CONTROL PANEL: Factory made cubicle type floor mounted LT Panel board, indoor type, made out of MS angle not less than 40X40X5 mm, and 2 mm thick MS CRCA sheet, front opening type, protection class IP-54, duly powder coated after seven tank process with electrolytic grace copper bus bar of 400 Amps capacity for four poles, with all standard switchgear and protection, internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of followings complete all as specified and directed:-
(v) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 metre at 75 % load under field condition and ox, 70DB at 3 metre from Gen set when DG set is working at full load along with testing conformance, labeling certification etc as laid down in GSR No 371(E) dt 17 May 2002. (vi) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 0.5 metre Space should be available all around the Set and height of plinth shall not be less than 0.5 metre. (vii) External cubicle Diesel storage tank of capacity adequate for storage of diesel for 12 hours operation of Gen Set. (viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer's standard practices.
AVIATION OBSTRUCTION LIGHT
Supply and fix aviation obstruction LED integral aviation light of Philips make cat part No.919515810001 x LED-K2/RD, 240 volts with timer switch of Indoasian cat part No.SVL 188g and one 10A MCB SP, 230 Volts, fixed in sheet metal enclosure complete all as specified and directed.
EXTERNAL WATER SUPPLY
Supply and laying Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-9", of 150mm size, with Socket and Spigot ends, conforming to IS - 8329, in standard lengths, suitable for Push-On Rubber Gasket Jointing, with inside Cement Mortar Lining and Black Bitumen external coating, including taking down any description and any size of pipe complete all as specified and as directed. Note : Excavation earth work and DI special shall be measured separately.
Supply and laying Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-9", of 100mm size, with Socket and Spigot ends, conforming to IS - 8329, in standard lengths, suitable for Push-On Rubber Gasket Jointing, with inside Cement Mortar Lining and Black Bitumen external coating including taking down any description and any size of pipe complete all as specified and as directed. Note : Excavation earth work and DI special shall be measured separately.
Material and labour for construction of Valve Chamber of size 900 X 900 X 900 mm internal size, suitable for Sluice Valve, with PCC 1:4:8, Type D2, using 40mm graded aggregate in foundation, 200 mm thick precast sement soncrete solid block masonry of 1:5:8, Type D5 graded stone aggregate in Cement Mortar 1:6, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of strata etc., removal of surplus spoil off the premises complete all as specified and directed.
Supply , Install, testing and commissioning of Submersible pumping set of 20 HP at 50 metre Head, 3 Phase, 415 Volts, AC, horizontal type, suitable for pumping of water from underground sump complete all as specified and directed.
Supply, installing, testing and commissioning of high pressure single head adjusteable chemical dozing system, High pressure maximum 5 Kgs/Sqcm maximum out put capacity 10 Ltrs/Hours, Power input 230 Volts, 50Hz, 40SPM 1/30 fractional HP, Single head gear motored adjustable dozing pump with prepation tank of net capacity 170 Ltrs, FRP dozing tank dia 650mm, Net height 375mm, Conical 300mm and gross height with stand 1000mm and mondatory accessories like lead tubing, connecting ferrules, Nuts, injection check valve, clay weight etc, service tank of net capacity 100Ltrs, FRP dozing tank top dia 540mm, bottom dia 480mm, Net height 575mm, consisting of with water inlet &outlet line with stainer, drain, overflow, level gauge, conical bottom for sludge deposition, pot hole with cover, Inspection port and including Agitator, 120 watt 900 RPMsingle phase flange mounted motor with plastic shaft and impeller, shaft and blade in plastic, mounting on tank , Lid will also have provision for mounting Dozing Pump on the Lid inlet and outlet connection to tank with size 20/25mm GI tubing medium grade including all special fittings like bend, elbow,tee,tapers,short pieces (single & double branch) type and angle/radius and straight connecting pieces of GI tubingas required with suitable control Gun Metal Gate valve from dozing system, PCC work for sport to pipe & valves, cutting and welding works etc complete all as specified and directed.
Supply and fix valve, reflux, with by-pass arrangement, 80 mm dia complete all as specified and directed.
Supply of calcium based high strength chlorination chemical for water in granular form, chlorine concentration level having 65%-70% Chlorine content, packed in 45 Kg capacity in factory, sealed in HDPE Container, superior quality, suitable for treatment of drinking water complete all as specified and directed. Make : Declibac /Potter and watts/Agitator/Varima (Ravi Enterprises)
Note :- (i) Approval of chemical (Calcium hypochlorine) shall be given after verification of test certifiate of chemical of various manufacture and other factors like chemical and safety and health hazard aspect of usage of chlororonation. (ii) The branch/make of the chlorination of chemical must be sealed in production and certified by Govt laboratory confirming compliance of specification suitable for drinking water with a declaration from the laboratory that from the technical strength, stability, health, safety and operation point of view, this product is used for drinking water applications for consumption by humans and the brand.make of calcium hypochlorite is suitable for drinking water chlorination and its sample has been tested by Govt Laboratory.
EXTERNAL ELECTRIC SUPPLY
Supply, install, testing and commissioning of factory made and CPRI tested, out door type, Panel board, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system, having bus bar chamber with air insulated PVC sleeved, with heat shrink, of colour code on copper bus bar of rating 1000 Amps for phases and neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof, IP-54 class protection and fabricated out of 3.15mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. The panel shall be both front and back openable type adequate space all around acessories such as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade, IS 694 marked or PVC sleeved copper strips of appropriate size as per standard practices and comprising of following accessories complete all as specified and directed:-
INCOMINGS (a) MCCB, 630 Amp, rating 4 Pole, microprocessor based Service Breaking Capacity 50 KA- 1 No. (b) Digital volt meter 0-500 Volts-01 No (c) Digital Ampere meter 0-300 Amps with and including CTs OUTGOINGS (a) MCCB, 250 Amp, rating 4 Pole, 25 KA, 415 Volts, 50 Hz- 01 No (AMF Panel) (b) MCCB, 200 Amp, rating 4 Pole, 25 KA, 415 Volts, 50 Hz- 02 Nos (Building and one spare) (c) MCB SPN, 32 Amp, rating 2 Pole - 01 No (Security light) (d) Internal wiring of panel with stranded copper cable of suitable size (e) Neon phase indicating lamp (Set of three)-01 Set (f) Stenceling of panel board including marking of distribuitions
Supply, install, testing and commissioning of factory made and CPRI tested, outdoor type, Panel board, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system, having bus bar chamber with air insulated PVC sleeved, with heat shrink of colour code on copper bus bar, of rating 400 Amps for phases and neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof, IP-54 class protection and fabricated out of 3.15mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. The panel shall be both front and back openable type adequate space all around acessories such as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated, multi stranded copper conductor cable, 1100 Volts grade, IS 694 marked or PVC sleeved copper strips of appropriate size as per standard practices and comprising of following acessorties complete all as specified and directed:-
INCOMINGS (a) MCCB 415 Volts,250 Amp rating, 4 Pole microprocessor based (Service Breaking Capacity 50 KA 1 Nos. (b) Digital volt meter 0-500 Volts-01 (c) Digital Ampere meter 0-300 Amps with and including CTs OUTGOINGS (a) MCCB ,200 Amp , rating 4 Pole , 25 KA 415 Volts50 Hz- 01 Nos(Pump house) (b) MCCB ,100 Amp , rating 4 Pole , 25 KA 415 Volts50 Hz- 02 Nos(Lift) one number spare
Supply, install, testing and commissioning of factory made and CPRI tested outdoor type Panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 400 Amps for phases and neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 3.15mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories sucxh as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of following acessories complete all as specified and directed:-
INCOMINGS (a) MCCB 415 Volts,250 Amp rating, 4 Pole microprocessor based (Service Breaking Capacity 50 KA 1 Nos. (b) Digital volt meter 0-500 Volts-01 (c) Digital Ampere meter 0-300 Amps with and including CTs OUTGOINGS (a) MCCB ,100 Amp , rating 4 Pole , 25 KA 415 Volts50 Hz- 04 Nos(For four floors each in Building) (b) MCCB ,80 Amp , rating 4 Pole , 25 KA 415 Volts50 Hz- 02 Nos(For Stair case and fire Panel)
Supply, install, testing and commissioning of factory made and CPRI tested outdoor type Panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 300 Amps for phases and neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 3.15mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories sucxh as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of following acessories complete all as specified and directed:-
INCOMINGS (a) MCCB 415 Volts,200 Amp rating, 4 Pole microprocessor based (Service Breaking Capacity 50 KA- 1 No. (b) Digital volt meter 0-500 Volts-01 No (c) Digital Ampere meter 0-300 Amps with and including CTs OUTGOINGS (a) MCCB, 100 Amp, rating 4 Pole, 25 KA, 415 Volts, 50 Hz- 04 Nos (lift)
Supply and fix LED street light fitting, 70W, 230V CCT 5700K/ 6000K, IP 65, with energy efficient with lumen efficiency not less than 110 lumen/watt, pf 0.8 with lamp and internal connection including bracket made of 40mm dia GI Pipe light grade fixed with MS Clamps, bolts and nuts of suitable size etc complete all as specified and directed.
S&F of street light mounting bracket made out of light grade GI pipe of size 35/40mm dia not less than 1.5 mtr length, bent to shape complete with two Nos GI clamps with suitable GI nuts, bolts and washers for fixing on pole complete all as specified and directed.
Supply and fixing of fibre looping box with connector and MCB SP, 6 Amps, 10 KA, 230 Volts, AC, of size 250 X 200 X 100 mm including making connections complete all as specified and directed.
DEMOLITION
Taking down main Switches, MCB DB with MCBs complete
Taking down sub main wiring of any sizes
Taking down electric meters complete and depositing to E/M store yard
Taking down Old unserviceable LT cable 10 Sqmm x 2 Core fixed on wall/ floor.
Taking down Old unserviceable LT cable 35 Sqmm x 3.5 Core fixed on wall/ floor.
Taking up or down GI tubing and connections including removal of GI pipe of size 80mm dia.
Removing unserviceable Gate valve/ stop valve of water supply lines closing the opening with plug or preperation for new as reqd necessary fitting complete
(a) 80 mm dia
(b) 50 mm dia
FIRE FIGHTING
Material and labour for providing and fixing, testing and commissioning of flanged end basket strainer, made from MS body with bottom and top removable flanges of size 250MM, etc all complete as per standard specification and as directed.
Material and labour for providing & fixing double flanged flexicon expansion joint (expansion bellows) of standard length as per manufacturers specifications including rubber gaskets, flanges, nuts, bolts and washers etc all complete as per standard specification and as directed for the following:-
(a) 250 mm dia
(b) 200 mm dia
Supply and Erection of Autostart panel (24 V) for the diesel engine complete with auto/manual switch, indication lamps protective fuses with battery charger, suitable of working on 230 V, AC, single phase, enclosure being vermin & dust proof. Also potential free conducts shall be provided for connecting to the building automation system. Battery shall be 2 x12 V, 180 AH. Two sets of battery bank controlled by a suitable change over switch, DC control on/off switch, Battery charger on/off switch, Hooter, Push Button,Terminal Block, Supply of 100mm Cable Tray of suitable size and material, Supply of Panel to Main Pump 70Sq mm/3 Core Cable (2 Run), Supply of Panel to Jockey pump 25 Sq mm/ 3 Core, Supply of Diesel Panel to Engine Control panel 2.5Sq mm/10Core, Supply of 70Sq mm Gland, Supply of 25Sq mm Gland, Supply of 70 Sq mm Lugs, Supply of 25Sq mm Lugs, Supply of 2.5Sq mm/10 Core Gland, Supply of dressing materials etc all complete as per standard specification complete all as specified and directed.
Supplying and laying for the Diesel and Electrical Panels (only to Pump from Main Panel)- incoming cables from the Main Contactor (cable for Pressure switches of Sprinkler system and cable for pump room) consisits of Supply of 100 mm cable tray, Supply of Panel to Main pump 70 Sqmm/3 core, Supply of panel to Jockey pump, Supply of Diesel panel to Engine control panel, Supply of 70Sqmm Gland, Supply of 255 Sqmm Gland, Supply of 70 Sqmm Lugs, Supply of 2.5 Sqmm Lugs, Supply of 2.5Sqmm/10 Core Gland and supply of dressing material etc all complete as per standard specification complete all as specified and directed.
Supplying and erecting of Pre fabricated M.S structural steel supports such as angle, channel, plates etc. conforming to relevant IS standards for laying/fixing above ground and grouting in concrete for Hydrant Pipes in Pump Room, Raiser, Yard Hydrant and Sprinkler Systems etc all complete as per standard specification complete all as directed and directed.
Material and labour for providing Sight Glass 100mm at alocations where directed complete all as directed.
Material and labour for making RCC core cutting of required dia and size in slab, floor, wall, beam etc with RCC core cutting machine without damaging the structure etc all complete as per standard specification complete all as specified and directed.
(a) 100 mm Dia
(b) 200 mm Dia
Material and labour for providing, laying, jointing and testing of R.C.C Hume pipe, NP2 class, conforming to IS-458 to cover and overlap correct levels below ground and laid to levels or falls and jointed complete with collars in CM 1:1 for following size of pipes complete all as specified and directed.
(a) 100 mm Dia
(b) 200 mm Dia
FIRE EXTINGUISHER
Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket fixed with anchor fastner, 2 Nos in Panel Room and 2 Nos.in Generator room complete all as specified and directed.
(a) ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg, Flat base including valve, discharge hose of not less than 10 mm dia, 1 metre long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket etc all complete as per standard specification complete all as specified and directed.
(b) ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 2 Kg, Flat base including valve, discharge hose of not less than 10 mm dia, 1 metre long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket etc all complete as per standard specification complete all as specified and directed.
(c) ISI marked (15683) Portable ABC Type Fire Extinguisher (6 Kg) with SQUEEZE Grip nozzle complete in all respects including initial fill and wall suspension bracket etc all complete as per standard specification complete all as specified and directed.
Supply and installation at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold and inclusive of providing MS stand duly painted over a coat of primer (4 nos.) etc all complete as per standard specification complete all as specified and directed.
Supply, installation, testing and commissioning of following types of Trolley (Wheel) Mounted extinguishers "CO2" type Fire Extinguisher of 22.5 Kgs capacity assembled out brand new cylinders with wheel valve arrangement; fitted with discharge hose and horn duly charged and ready for use manufactured conforming to I.S.2878 with ISI Mark etc complete as per standard specification, fixed at directed locations complete all as specified and directed.
FIRE ALARM SYSTEM
Supply, Installation, Testing & Commissioning of 2 x 1.5 Sq.mm. Copper Armoured FRLS-H PVC Cable etc all complete as per standard specification for the system complete all as specified and directed.
PUBLIC ADDRESSABLE SYSTEM
SIGNAGES
Material and labour for providing and installing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut PVC non- reflective self adhesive vinyle painted foam board, complete with mirror fasteners complete all as specified and directed.
(a) Signages with printed "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" of 1.5cm height letters in red with white back ground. The size of the board shall be 25cm x 30cm and shall be fixed at the height of 2mts from finished floor near Manual Call Points.
(b) Floor indentification signage (i.e, GROUND FLOOR, FIRST FLOOR, 2ND FLOOR, … ETC.,) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5cm with contrasting colour from back ground and size of board shall be 15cm x 60cm and fixed at locations all as directed.
(c) Providing and fixing in position the Sticker type, signage of "Fire Extinguisher" to be pasted immediately above the every extinguisher all as directed.
(d) Providing and fixing in position the Sticker type signage of "Fire Hydrant & Hose Reel" to be pasted on door of the every fire shaft at all floors all as directed.
(e) Providing and fixing in position the sign board of "ASSEMBLY POINT" complete with 1 mm thick rigid plastic board size of 400 mm x 300 mm, fixed on ground by using a steel rod / pipe at designated places as per drawing all as directed.
Material and labour for providing and installing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut PVC non- reflective self adhesive vinyle painted foam board, complete with mirror fasteners complete all as specified and directed.
(i) Type -I comprising the following A) ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS. B) EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY AND ASSEMBLE AT VARIOUS ASSEMBLY POINTS. C) IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER. D) BE CALM AND DO NOT GIVE ANY ROOM FOR PANIC. WALK, DO NOT RUN. E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUTION, FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM.
(ii) Type - II comprising the following ACTION BY SECURITY / RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM. A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM. B) INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS: xxxxxxxxxxxxxxxxxxx C) REFER EVACUTION PLAN FROM EVACUATING STANDARD PEOPLE. D) GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE. E) IN CASE OF THE CASUALITIES, CALL AMBULANCE BY DIALLING NUMBER…………….
NOTE : Amount of credit of Rs. 29,89,368.00 for retrieved materials is mentioned in schedule of credit on Srl Page No. 65 of tender documents in pdf form which will be deducted offline while acceptance of tender.
SOOD ASSOCIATES PVT LTD
SANKALP INFRACON
Mukund Enterprises Private Limited
RAMDEV CONSTRUCTION CO.
Hariom Projects Pvt Ltd