| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-Finance KARNATAKA | RAICHUR | KARNATAKA | 584123 | ₹1.4 Cr | L1 | Accepted-Finance Low Rate |
| 2 | L2₹1.4 Cr+₹39,879.41 (0.29%)Rejected-Finance | ₹1.4 Cr+₹39,879.41 (0.29%) | L2 | Rejected-Finance High Rate |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹2.7 L
Closing Date
28 Oct 2021, 1:00 pmClosed
Superintendent Engineer
UPSCIDCO Ltd Jhansi
Construciton of Upgration workof KGAV Nadigaon Jalaun
2021_SCIDC_633297_1
222/SE/Jhansi/2021-22
Open Tender
Civil Works - Others
Item Rate
270 days
Nadigaon Jalaun U.P.
Please refer the tender document
2 documents required · 2 mandatory
₹2,596
Yes
UPSCIDCO LTD
₹2.7 L
Yes
13 Nov 2021
20 Oct 2021
28 Oct 2021
20 Oct 2021
28 Oct 2021
20 Oct 2021
20 Oct 2021 - 28 Oct 2021
Amount
Gorund Floor
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :Base concrete in foundation in 1:4:8 c:c/s:ballast the cost of centering and shuttering - All work up to plinth level :
Providing & Supply sand Filling in Foundation
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in foundation and plinth in:Brick work in Foundation in 1:6 cement:sand mortar
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement : R.C.C. Footing in M20
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement : R.C.C. Column in M20
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement : R.C.C. Plinth Bend
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement : R.C.C. Lintel Beams
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement : R.C.C. Loft in M20
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement : R.C.C. Stair in M 20
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement : R.C.C. Slab Beam in M 20
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement : G.F. R.C.C. Slab in M20
Sand Filling in Plinth including supply of necessary quantity of sand from a distance not exceeding 8 km . ( 5 miles ) from the from the site of work and including watering dressing etc. Rate to including cost of all material , labour and T&P etc. required for proper completion of the work .( Rate is including Royality)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :Lean concrete in 1:4:8 under floor
40 mm thick cement concrete flooring with concrete hardener topping,under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 20 mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardenermix : 2 graded stone aggregate 6 mm nominal size) by volume, hardeningcompound mixed @ 2 litre per 50 kg of cement or as per manufacturer’sspecifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
providing and laying damp proof course 25mm Thick D.P.C.In 1:2:4 (1 cement:2coarse sand :4 stonne agg. 10 mm nominal size) and curing complete.
Brick work with common burnt clay machine moulded perforated bricks of class designation 15 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) :Brick work in Super structure in 1:6 cement:sand mortar in 230 tk Brick work, for superstructure in 1:6 c:sand mortar
Brick work with common burnt clay machine moulded perforated bricks of class designation 15 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:4 (1 cement : 4 coarse sand) :Brick work in Super structure in 1:4 cement:sand mortar in 115 mm wall
6-10 mm ceiling plaster in 1:3 cement:sand mortar inluding all material labour T&P and safloding complete
15 mmplaster in 1:6 cement:sand mortar in rough surface inluding all material labour T&P and safloding complete . Including internal rounded angles chamfers and rounded angles not exceeding 80 mm . In girth and finished even and smooth .
12 mmplaster in 1:6 cement:sand mortar in rough surface inluding all material labour T&P and safloding complete . Including internal rounded angles chamfers and rounded angles not exceeding 80 mm . In girth and finished even and smooth .
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Matt finish Rectified flooring in toilet floor
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.dado/skirting in toilet
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Entrance Door (ED) Aluminium door
Sliding Door
Providing and fixing factory made ISI marked steel glazed l doors; windows and ventilators;side/top/centre hung; with beading and all members such asF7d;F4b;k11b etc complete of standard rolled steel section;joints mitred and flash butt welded and sash bars tenoned and reveted; including providingand fixing of necessaryt hinges ;pivots inckuding applying a priming coat of approved steel red oxide primer.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:& commercial quantity (kanju) sitapur ply or other approved ply wood flush sshutters 30 mm (1 1/4") thick.
Painting or Vanishing on Iron works in small areas or new wood work with one coat of ready mixed printing paint & one coaty of approved superior quality ready mixed paint of clear synthetic varnish i/c supply of all materials, labourand T&P etc. Required for proper completion of the work. Paint to be used should confirm to the I.S.I. No. 103 1950 but for every coat after first coat details of cost for 650 sft. area.
20mm Bearing plaster in 1:3 cement:sand mortar with neat finish including supply of materials labour and T&P etc. required for proper completion of the work.
Two coat oil bound distemper Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade.Two Coat Oil bound distempar inside
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm Two coat weather coat Apex/ultima
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing cutting bending MS bar Reinforcement in RCC Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
20mm Bearing plaster in dedo or skirting 1:2 cement:sand mortar with neat finish including supply of materials labour and T&P etc. required for proper completion of the work.
Providing and fixing Glass pan equal or equivalent I.S.I marked quality putty . Drands and springs and including supply of all material and labour etc. complete.in window /ventilator (4.8 to 5.7 mm thick)
Supply & fixing glavanished Mosquitos proof,heavey quality iron wire gauge or expanded metal of heavey quality over windoes and i/c supply and fixing of C.P. teak wood/Ms flat battens 8 cm X 1 cm (3"X3/8") and i/c supply of necessary screws, all materials, labour and T&P etc. required for proper completion of the work.
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diameter.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe 110mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5°
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand)and making good the wall etc. complete.
Providing and fixing Oxidized door fittings
Supply and filling of Moorum soil in plinth protection /appron
Brick work with common burnt clay machine moulded perforated bricks of class designation 15 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:4 (1 cement : 4 coarse sand) :Brick work in appron .
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :Lean concrete in 1:4:8 under floor
40mm cement concrete flooring in 1:2;4 (1 cement : 2 coarse sand :4 stone agg. Of 20 mm nominal size ) laid in one layer finished with floating cost of neat cement .
Providing and fixing Granite stone in water quash platform and 600 high in wall Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge
Providing and laying of 20mm thick Kota stone flooring over 20mm thick base of Cement mortar 1:4 (1cement: 4 coarse sand) laid over jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete.
Providing & laying of 8 to 10mm thick ivory or light shade Vitrified tiles of 600mmX600 mm size in flooring or skirting laid with 1:3 ( 1cement : 3 Coarse sand) finishing with cement slurry & with pigment grouting & polishing complete i/c supply of all materials, labour T&P required for proper completion of work. in Skiting
First Floor
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :and super structure in M20 R. C. C. Column
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :and super structure in M20 R. C. C. Lintel Beams
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :and super structure in M20 R. C. C. Loft & Chajja
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :and super structure in M20 R.C.C. Stair
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :and super structure in M20 R.C.C. Slab Beam
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :and super structure in M20 F.F. R.C.C. Slab
40 mm thick cement concrete flooring with concrete hardener topping,under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 20 mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardenermix : 2 graded stone aggregate 6 mm nominal size) by volume, hardeningcompound mixed @ 2 litre per 50 kg of cement or as per manufacturer’sspecifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Brick work with Class-150 class bricks instead of Class-75 informing to IS: 2222 -1991 in superstructure above plinth level upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) :super structure 230 tk Brick work, for super structure in 1:6 in 230mm wall
Brick work with Class-150 class bricks instead of Class-75 informing to IS: 2222 -1991 in superstructure above plinth level upto floor five level in cement mortar 1:4 (1 cement : 4coarse sand) :115MM THICK WAL
Brick work with Class-150 class bricks instead of Class-75 informing to IS: 2222 -1991 in superstructure above plinth level upto floor five level in cement mortar 1:4 (1 cement : 4coarse sand) :115MM THICK WAL Half Brickwork For S. F. Parapet
6-10 mm ceiling plaster in 1:3 cement:sand mortar inluding all material labour T&P and safloding complete
15 mmplaster in 1:6 cement:sand mortar in rough surface inluding all material labour T&P and safloding complete . Including internal rounded angles chamfers and rounded angles not exceeding 80 mm . In girth and finished even and smooth .
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing of M.S. angle iron Z section window (approved Section) with Specified design of grill out side openable design of window and gril as per approved drawing 10mmsq bar 75mm c/c and 3no. bar group @ 75mm and four group in horizontal including providing stay and one coat of red oxide primer excluding glass pans.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
Painting or Vanishing on Iron works in small areas or new wood work with one coat of ready mixed printing paint & one coaty of approved superior quality ready mixed paint of clear synthetic varnish i/c supply of all materials, labourand T&P etc. Required for proper completion of the work. Paint to be used should confirm to the I.S.I. No. 103 1950 but for every coat after first coat details of cost for 650 sft. area.
20mm Bearing plaster in 1:3 cement:sand mortar with neat finish including supply of materials labour and T&P etc. required for proper completion of the work.
12 mmplaster in 1:6 cement:sand mortar in rough surface inluding all material labour T&P and safloding complete . Including internal rounded angles chamfers and rounded angles not exceeding 80 mm . In girth and finished even and smooth .
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Two coat oil bound distemper Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade.Two Coat Oil bound distempar inside
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications;-Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @0.75 ltr /10 sqm
Providing and fixing 10 mm thick 300x300mm resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.
Providing and laying rectified Glazed Ceramic Wall tiles of size 300x450mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mmsquare 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
20mm Bearing plaster in dedo or skirting 1:2 cement:sand mortar with neat finish including supply of materials labour and T&P etc. required for proper completion of the work.
Providing and fixing Glass pan equal or equivalent I.S.I marked quality putty . Drands and springs and including supply of all material and labour etc. complete.in window /ventilator (4.8 to 5.7 mm thick)
Supply & fixing glavanished Mosquitos proof,heavey quality iron wire gauge or expanded metal of heavey quality over windoes and i/c supply and fixing of C.P. teak wood/Ms flat battens 8 cm X 1 cm (3"X3/8") and i/c supply of necessary screws, all materials, labour and T&P etc. required for proper completion of the work.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe 110mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5°
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand)and making good the wall etc. complete.
Providing and fixing Oxidized door fittings
Providing and fixing MS sheet gate in mumty
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge
Providing and laying of 20mm thick Kota stone flooring over 20mm thick base of Cement mortar 1:4 (1cement: 4 coarse sand) laid over jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete.
Providing and laying of 20mm thick Kota stone flooring over 20mm thick base of Cement mortar 1:4 (1cement: 4 coarse sand) laid over jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete.
Providing and fixing glass strips in joints of terrazo/ cement concrete floors.
Sanatory Work
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
Providing and fixing C.P. brass bib cock of approved quality conformingto IS:8931 : 15 mm nominal bore
Providing and fixing white vitreous china pedestal type water closet(European type) with seat and lid, 10 litre low level white vitreouschina flushing cistern & C.P. flush bend with fittings & C.I.brackets,40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore
Providing and fixing 600x450 mm beveled edge mirror of superiorglass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washerscomplete.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm,78 mm wide and effective height of 88 mm, weighing not less than 170 gms
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing PTMT grating of approved quality and colour.150 mm nominal size square 100 mm diameter of the inner hinged round grating
Providing and fixing G.I. pipes complete with G.I. fittings and clamps,i/c cutting and making good the walls etc. 15 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps,i/c cutting and making good the walls etc. 20 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps,i/c cutting and making good the walls etc. 25 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps,i/c cutting and making good the walls etc. 32 mm dia nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting andthreading the pipe and making long screws etc. complete (New work) : 20 mm dia nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting andthreading the pipe and making long screws etc. complete (New work) : 32 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) : 32 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing, laying and jointing PVC SWR pipes of Type A as per IS 13592 of approved make for soil, waste and vent pipes with solvent joints including necessary fittings like bends, tees, Y, hanger bars of required length at regular intervals etc,including cutting and making good masonry or concrete floor, walls for taking the pipelines outside the building into the ducts / crossing of beams and testing of pipelines, Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. Making proper connection with joint as required as per manufacturer. Cutting, chases / holes in floors / walls / slab including making good the walls, ceiling etc. all complete as per specifications and as directed by the engineer incharge. 110mm Dia PVC SWR Pipe Type'A'
Providing, laying and jointing PVC SWR pipes of Type A as per IS 13592 of approved make for soil, waste and vent pipes with solvent joints including necessary fittings like bends, tees, Y, hanger bars of required length at regular intervals etc,including cutting and making good masonry or concrete floor, walls for taking the pipelines outside the building into the ducts / crossing of beams and testing of pipelines, Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. Making proper connection with joint as required as per manufacturer. Cutting, chases / holes in floors / walls / slab including making good the walls, ceiling etc. all complete as per specifications and as directed by the engineer incharge. 75mm Dia PVC SWR Pipe Type'A'
Supply & fixing 100 dia inlet 75 mm (3”) outlet PVC Floor trap ( Supreme / Prince) first quality, ISI marked and supported with brick masonry seat as per site requirement with standard practice including cost and conveyance of all materials, taxes, labour charges etc, complete and as directed by the as direcyted by the Engineer-in-charge.
Providing and fixing C.P. Health faucet (spray Nozzle) of approved quality for European water closet conforming to IS:8931 a) 15 mm nominal bore
Construction of Septick tank 100 USER Size as per ISI sstandered 5.70x2.10x1.70
Earth work in excavation in foundation/tank
Base concrete in 1:4:8 cement:sand:stone ballast
Brick work in 1:4 cement:sand mortar in septick tank wall
Brick work in 115mm wall in 1:4cement:sand mortar baffle wall
R.c.c. work in 1:1.5:3 cement:sand:stone grit in Slab and beam
Providing cutting beding MS bar Reinforcement in slab @2%
20mm plaster in 1:3 cement:sand mortar with neat cement finish wall
P.c.c. in 1:2:4 cement:sand :stone grit in base to making slope
Providding and fixing C.I. man hole chembar 600x600mm size in slab
Providing and fixing C.I. vent pipe 100mm dia
Providing and fixing c.i. cowel guard 100mm dia
Providind and fixing 150mm dia inlet and out let pipe
Construction of Soak pit
Earth work in excavation in foundation/tank
Brick work in 1:3 cement:sand mortar in soak pit tank wall
Supply and filling of Brick bat bat in soak pit in base
R.c.c. work in 1:1.5:3 cement:sand:stone grit in Slab and beam Slab
Providing cutting beding MS bar Reinforcement in slab @2%
Providind and fixing 150mm dia inlet and out let pipe
Construction of man hole 45x45 cm size complete
Earth work in excavation in foundation/tank
Base concrete in 1:4:8 cement:sand:stone ballast
Brick work in 1:4 cement:sand mortar in septick tank wall
R.c.c. work in cover of man hole
Providing cutting bending MS bar reinforcement
20mm plaster in 1:3 c:sand mortar with neat finish
Appron drain 20x15 cm size complete
Earth work in excavation in foundation/tank
Base concrete in 1:4:8 cement:sand:stone ballast
Brick work in 1:4 cement:sand mortar in septick
20mm plaster in 1::2 cement:sand mortar with neat finish
CONSTRUCTION OF TUBE WELL BORING AND INSTALLATION OF SUB.PUMP
Tube well Boring 4.5" dia by heavey Rig machine
Providing of 6 kg/cm2 Kisan make Casing pipe
Providing and fixing of KSB make submersiable Three phase 7 stage 1/2 HP pump(m.R.)
Providing and fixing starter pannel board
Providing and fixing of of sub. Cable
Providing and fixing of M.S.clamp
Providing and fixing of G.I. Pipe 32 mm dia B class meadium
Installation of pump labour/fixing
making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter
Providing and fixing of G.I. Pipe 32 mm dia B class meadium
Electrical Work
Wiring point for light with 1.50 sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab along with the reinforcement before concreting complete with 1.50 sq. mm FRLSH PVC insulated multi strand copper conductor cable as earthwire drawn inside the conduit, piano type switch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc. complete in all respects, as directed including matching colour wash.
Wiring point for two way light with 1.50 sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall, and partly laid in slab along with the reinforcement before concreting complete with 1.50 sq. mm FRLSH PVC insulated multi strand copper conductor cable as earthwire drawn inside the conduit, piano type switch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc. complete in all respects, as directed including matching colour wash.
Wiring point for fan/fresh air fan with 1.50 sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall, and partly laid in slab along with the reinforcement before concreting complete with 1.50 sq. mm FRLSH PVC insulated multi strand copper conductor cable as earthwire drawn inside the conduit, piano type switch & ceiling rose on 3 mm thick phenolic laminated backelite sheet etc. complete in all respects, as directed including matching colour wash.
Wiring point for plug with 1.50 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall,and partly laid in slab along with the reinforcement before concreting complete with 1.50 sq mm FRLSH PVC insulated multi strand copper conductor cable as earthwire drawn inside the conduit,piano type switch& socket on 3 mm thick phenolic laminated backelite sheet etc.complete in all respects, as directed including matching colour wash.
Wiring point for Exhaust fan with 1.50 sq. mm FRLSH PVC insulated mulatistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab along with the reinforcement before concreting complete with 14 SWG copper earth continuity wire, 15 Amp.piano type switch and ceiling rose on 3 mm thick phenolic laminated bakelite sheet etc. complete in all respects including matching colour wash.
Supply and fixing of Switch box 200 x 250 x 65 mm size of approved make made up of 1.00 mm thick ISI marked G.P. sheet all 4 corners folded & spot welded for screw and holes plugged with PVC Nylon caps. Two or more holes for pipe entry of 25.4 mm or upper and lower sides of the box. Holes Should be semi - shuttered type and fitted with heavy brass earth Piller duly screwed & brand name should be embossed. Box flushed in wall including cutting of brick work, fixing it to the level with cement sand mortar, including matching colour wash with s/o all materials, labour and T & P required for proper completion of work as directed at site by the Engineer in charge.
Supply and fixing of Switch box 200 x 250 x 65 mm size of approved make made up of 1.00 mm thick ISI marked G.P. sheet all 4 corners folded & spot welded for screw and holes plugged with PVC Nylon caps. Two or more holes for pipe entry of 25.4 mm or upper and lower sides of the box. Holes Should be semi - shuttered type and fitted with heavy brass earth Piller duly screwed & brand name should be embossed. Box flushed in wall including cutting of brick work, fixing it to the level with cement sand mortar, including matching colour wash with s/o all materials, labour and T & P required for proper completion of work as directed at site by the Engineer in charge.
S/W of submain with two number 2.50 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm heavy duty (2 mm thick ) PVC conduit pipe concealed in wall, and partly laid in slab along with reinforcement before concreting with one number 1.50 sq mm FRLSH PVC insulated multi strand copper conductor cable as earth continuity wire drawn in conduit. respects.
S/W of submain with four number 2.50 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 25 mm dia heavy duty (2 mm thick ) PVC conduit pipe concealed in wall, and partly laid in slab along with reinforcement before concreting with one number 1.50 sq mm FRLSH PVC insulated multi strand copper conductor cable as earth continuity wire drawn in conduit. respects.
S/W of submain with two number 4.00 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2 mm thick ) PVC conduit pipe concealed in wall, and partly laid in slab along with reinforcement before concreting with one number 2.50 sq mm FRLSH PVC insulated multi strand copper conductor cable as earth continuity wire drawn in conduit. respects.
S/W of submain with four number 10.00 sq. mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in PVC conduit pipe concealed in wall, and partly laid in slab along with reinforcement before concreting with two number 6.00 sq mm FRLSH PVC insulated multi strand copper conductor cable as earth continuity wire drawn in conduit. respects.
S/F of 100 Amp. Four pole Change over switch on 40 mm x 40 mm x 6 mm angle iron frame. Includingthe costof labour T & P, painting and other material required completion of the work as per direction and satisfaction of Engineer in charge.
Supply & laying of aluminium conductor PVC insulated armoured served sheated cables 1100 Volt grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps of suitable size or as directed by the Engineer-Incharge, complete in all respeted.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 35.00 sq. mm x 3.50 core
S/F of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. comolete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. 35.00 sq. mm x 3.50 core
S/F fo palm or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. comolete in all respect.as per direction of Engineer - Incharge. 25.00 sq.mm.
S/F fo palm or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. comolete in all respect.as per direction of Engineer - Incharge. 35.00 sq.mm.
Supply and laying of 25 mm x 3 mm G.I. strip from earth electrode directly in the ground as required complete in all respects.
Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000 mm, outer pipe dia 50 mm , inner dia 25 mm , terminal dia 12 mm, outer G I pipe of 16 SWG and inner G I pipe of 12 SWG with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of rateining capacity along with 30 cm square C.I. frame with hinged cover and masonary housing (from electrode terminal to switch board cost of 25 x 3 mm G I strip will be extra) Make: As approved in U.P.P.W.D. & C.P.R.I. Certified.
S/F of 6 - 32 Amp. SP MCB (10KA) C Curve , CAT-A
S/F of 40 Amp. DP MCB (10KA) C Curve , CAT-A
S/F of 63 Amp. 4 Pole MCB (10KA) C Curve , CAT - A
S/F surface/ flush mounting 8 ways SPN distribution board without MCB complete in all respect and as directed at site by Engineer in charge. CAT - A
S/F surface/ flush mounting 12 ways SPN distribution board without MCB complete in all respect and as directed at site by Engineer in charge. CAT - A
S/F Surface / flush mounting 6 ways TPN distribution board with additional metal door without MCB complete in all respect and as directed at site by Engineer in charge. CAT - A
Supply and fixing danger board fabricated from 10 gauge. M.S. Sheet as per I.E. Rules.
S/F of 16 SWG M.S. durm with louvers duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respects .
S/F of crimping, solderless, copper tin electroplated lugs of Dowells / Ismail make suitable for 1.50 sq. mm To 10.00 sq.mm cables, including tapping with insulating tape, complete in all respect.
S/F of shock treatment chart duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work.
S/L of 1800 mm x 900 mm x 12 mm thick chequred rubber matting of tested quality.
S/F of power plug with 15 Amp. / 250V flush type switch and 5 pin 15 Amp./ 250 V flush type universal socket in suitable M.S. box of 175 mm x 100 mm x 50 mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer.
S/F of Hexagonal fan box with hexagonal / Round G P fan box of approved make made up of 1.00 mm thick ISI marked G P sheet spot welded four to eight holes for pipe entry of 25.40 mm on upper and lower sides of the box . Holes should be semi shuttered type with 0.50 mm G. P. sheet made upper and lower cover duly screwed fitted with 300 mm round zinc coated M. S. Bar x 12 mm and brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreating along with supply of all material, labour, T&P etc. required for proper completion of the work.
S/F of electronic fan regulator 120 - 280 V. ISI marked, on the existing switch board including making connections, required material, labour T/P etc.for proper completion of work to the satisfaction of Engineer in charge of work.
S/F of Recess / Surface / Pendent mounting round 15 to 18 watt LED Down lighter having powder coated die cast aluminium housing with heat sink, diffuser / Reflector and driver set complete in all respects. CAT - AA.
S/F of LED Tube Light Batten Fitting suitable for up to 1 x 22 Watt LED tube light on surface complete in all respects. CAT - AA.
S/F of LED Street Light fitting having die cast aluminium body and diffuser with driver set suitable for 45 Watt to 50 Watt. confirming to IP 66 protection complete in all respects. CAT - AA.
S/F of Ceiling fan 1200 mm sweep, Double ball bearing , Capacitor type ISI marked complete. etc. Usha / Crompton Greaves / Bajaj / Khaitan make.
S/F of Exhaust fan (Not fresh air fan) 300 mm sweep, Double ball bearing complete on the existing hole with suitable size of rag bolts, nuts and washers etc. Complete in all respects. Usha / Crompton Greaves / Bajaj make.
S/F of Exhaust fan 450 mm sweep ISI Marked heavy duty, Double ball bearing complete on the existing hole with suitable size of rag bolts, nuts and washers etc. Complete in all respects. Usha / Crompton Greaves / Bajaj/ panasonic make.
S/F of Bakelite fan box sheet on existing fan box complete in all respects.
S/F of 100 Amp / 415 Volt Rewireable Type (kit-kat) Fuse unit- 3 No. & 1 No. Neutral link on wooden board with the help of ragbolt / hold fastner complete in all raspects.
S/F of LED Bulb 12 - 15 watt. Bajaj / Crompton / Philips make.
S/F of water tight oblong bulkhead fitting of approved make complete with prismatic glass holder rubber gasket, G.I. Guard etc.
S/F of 35.00 sq. mm x 4 core umarmoured cable ISI marked for connection with G.I. support wire complete in all respects.
Fire Extinguisher work
S/F of fire extinguisher, ABC type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all mateials and labour for proper completion of work.
S/F of fire bucket, round bottom made of G.I.sheet 9 - 11 litres capacity duly painted as per fire brigade design, supported on hanging chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge.
AMRIT SINGH THEKEDAR
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .