Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹77.6 LAccepted-AOC HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | 1 | Accepted-AOC Acceptance Of Tender | |
| 2 | 2₹83.4 L+₹5.8 L (7.45%)Rejected-Finance NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹84.7 L+₹7.1 L (9.18%)Rejected-Finance 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | 3 | Rejected-Finance Not L1 | |
| 4 | 4₹93.3 L+₹15.7 L (20.2%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | 4 | Rejected-Finance Not L1 |
Tender Value
₹86.5 L
EMD Value
₹1.7 L
Closing Date
9 Dec 2024, 6:00 pmClosed
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, Lucknow Cantt, Lucknow-226002
SPL REPAIR/ REPLACEMENT OF AC WATER COOLER DESERT COOLER REFRIGERATOR AND DEEP FREEZER AGAINST BER UNDER GE (E/M) LUCKNOW
2024_MES_682364_1
CWE/LKO/EM/T-58 Of 2024-25
Open Tender
Miscellaneous Works
Item Rate
180 days
LUCKNOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE EM Lucknow
₹1.7 L
Yes
23 Jan 2025
4 Nov 2024
16 Dec 2024
4 Nov 2024
9 Dec 2024
25 Nov 2024
4 Nov 2024 - 25 Nov 2024
Amount
Taking down of old unserviceable window/ Split AC of any size capacity and make from different location in lucknow cantt Note:- Old U/S AC will deposited in MES AC Yard
Taking down of old unserviceable water cooler of any size capacity and make from different location in lucknow cantt Note:- Old U/S water cooler will deposited in MES AC Yard
Taking down of old unserviceable Desert cooler of any size and make from different location in lucknow cantt Note:- Old U/S desert cooler will deposited in MES AC Yard
Taking down of old unserviceable Refrigerator and Deep Freezer of any size and make from different location in lucknow cantt Note:- Old U/S Refrigerator and Deep Freezer will deposited in MES AC Yard
Supply and install wall mounted hi wall split Air Conditioner capacity 1.5 TR (Hot & Cold) indoor & outdoor, 100% copper, Inverter type complete with cordless remote control unit, electric cable, supply and discharge copper tube upto 3 RM with inbuilt air ioniser and plasma filter for better indoor air quality with minimum 3 star rated and EER 3.2 complete all as directed and detail as under :- The rate is included for following item-: (a) All other connected civil work like hole cutting & other misc work reqd for installation of split AC for proper functioning as directed by EIC. including making good disturbed surfaces as per existing. (b) S&F PVC pipe 15 mm dia transparent flexible heavy duty for water drainage pipe of upto 06 RM at site. (c) S&F copper pipe as per site requirement with insulation of complete pipe with PVC casing & caping of size 75 x 75 mm/reqd size for mechanical protection complete. (d) S&F Wall mounted stand for outdoor unit as suitable for fixing of AC. (e) Sheet metal enclosures with socket plug top and MCBs 20 Amp for single pole and neutral enclosures with a two pin and earth plug and socket Plug top provided by contractor with AC wire.
Supply and install wall mounted hi wall split Air Conditioner capacity 2.0 TR (Hot & Cold) indoor & outdoor, 100% copper, inverter type complete with cordless remote control unit, electric cable, supply and discharge copper tube upto 3 RM with inbuilt air ioniser and plasma filter for better indoor air quality with minimum 3 star rated and EER 3.2 complete all as directed and detail as under :- The rate is included for following item-: (a) All other connected civil work like hole cutting & other misc work reqd for installation of split AC for proper functioning as directed by EIC. including making good disturbed surfaces as per existing. (b) S&F PVC pipe 15 mm dia transparent flexible heavy duty for water drainage pipe of upto 06 RM at site. (c) S&F copper pipe as per site requirement with insulation of complete pipe with PVC casing & caping of size 75 x 75 mm/reqd size for mechanical protection complete. (d) S&F Wall mounted stand for outdoor unit as suitable for fixing of AC. (e) Sheet metal enclosures with socket plug top and MCBs 20 Amp for single pole and neutral enclosures with a two pin and earth plug and socket Plug top provided by contractor with AC wire.
Supply and install Split convertible AC ductable type 11 TR, (double compressor in single outdoor) twin circuit indoor & outdoor complete, 100% copper, energy efficient, designed for high ambient conditions, these units guarantee reliable operationeven at 52 degree C outdoor air temperature complete all as directed by Engineer-in-Charge. Note : The rate is included for following items :- (i) All other connected civil work like hole cutting & other misc work reqd for installation of split AC for proper functioning as directed by EIC. including making good disturbed surfaces as per existing. (ii) S&F Copper pipe suitable for indoor & outdoor unit (5/8" x 1/2")-40 RM. Note : (ii) Drain pipe - 20 RM (iv) Insulation of both the copper pipes with insulating material and covering the complete pipe with PVC casing & caping of size 75 x 75 mm/reqd size for mechanical protection of copper pipe complete.
Supply, installation,commisioning of Water cooler partially stainless steel, electric driven single phase having approx storage and nominal cooling capacity 40/80 Ltrs
Supply and installation evaporative desert coolers (steel body) factory made 22/24 gauge PGI sheet of size 100x70x60cm appx , front and side panels are made of same gauge with wood wool pads having nominal air flow capacity of 4000 cfm, or nearest size,having exhaust fan motor with copper winding of capacity 280 to 310 watt with 18” steel blade size, and submersible pump of capacity 1.5m head , and powder coated, with all fittings and fixtures as directed by ENG-IN- CHARGE on site complete all as specified and directed.”(Make-Champion or equivalent.) Note- make of exhaust fan- Champion/ Bajaj/Usha/Crompton greaves/Khaitan. Note :- The rates are included of material and labour for Fabrication cooler stand size 60x70x80 cm( LxWxH) angle iron of 35x35 x 5 mm as directed conforming to Fe-290 Gde E-165, including cutting, welding, cross support in upper side and lower side with flat iron or angle iron of 35x35x5etc, two coats synthetic enamel paint over one coat red oxide primer, installed in location complete all as specified and directed.
Supply, install and testing of refrigerators of gross volume 185 Ltrs single door smart inverter compressor, frost free BEE star rated suitable for working on 230 Volts SP 50 HZ supply shade as approved complete all as specified and directed
Supply, install and testing of refrigerators of gross volume 290Ltrs double door smart inverter compressor Door Cooling, smart diagnosis auto smart connrct frost free BEE star rated suitable for working on 230 Volts SP 50 HZ supply shade as approved complete all as specified and directed
Supply, install and testing of refrigerators of gross volume 310 Ltrs double door smart inverter compressor Door Cooling, smart diagnosis auto smart connrct frost free BEE star rated suitable for working on 230 Volts SP 50 HZ supply shade as approved complete all as specified and directed
Supply, installation, commissioning and testing of metal top/hard top Deep freezer of capacity 300/ 320 Ltrs Single door suitable for working on 240 Volts SP 50HZ complete all as specified and directed.
ANKIT SHIP REPAIRERS AND SUPPLIERS (BID ID -3178834)
M/S S.B. Singh and Sons (BID ID -3179067)
M/s A.K Construction (BID ID -3184282)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .