Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78.5 LAccepted-AOC | L1 | Accepted-AOC The tenderer is the lowest | |
| 2 | L2₹83.3 L+₹4.8 L (6.05%)Rejected-Finance NO 11 91 KAMARAJ STREET THIRUVALLUVAR NAGAR AYYANAVARAM CHENNAI 600 023 | CHENNAI | CHENNAI | TAMIL NADU | 600023 | L2 | Rejected-Finance The tenderer is not lowest |
Tender Value
₹79.1 L
EMD Value
₹1 L
Closing Date
12 May 2022, 3:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commissioner Karaikal Municipality
Dr. Ambedkar Street, Karaikal
Manufacture Supply Delivery Installation Testing and Commissioning of Liquefied Petroleum Gas LPG based Scientific Crematorium furnace all units and Construction of Crematorium Building at Patchur Graveyard in Karaikal Municipality on turn key basi
2022_DLA_10136_1
01/KM/e-tenders/2022-23
Open Tender
Civil Works
Item Rate
90 days
Karaikal
as specified in Request for proposal
4 documents required · 4 mandatory
₹1,050
₹1 L
Karaikal Municipality
6 Jan 2023
27 Apr 2022
12 May 2022
27 Apr 2022
12 May 2022
27 Apr 2022
4 May 2022
90 days
Amount
Design, Supply & Construction of Cremation Chamber having the inner dimensions of 940mm x 1150mm x 2350mm and Outer Dimention will be 1900mm X 3000mm X 2100mm fabricated out of heavy duty material & provided with necessary openings for gasous fuel firing through burners and feeding body. The Primary Chamber shall be constructed with 4 Layers inner most will be 115mm IS-8 quality fire bricks (Dalmia Make only ) 2nd layer will be 115mm Hot face Insulation Bricks Rajestan Make 3rd layer will be75mm Cold face Insulation brick 4th layer will be 150mm Country Brick for the Outer Glazed tile provission to with stand temperature and insulation bricks to ensure minimum heat loss. The furnace shall have Ash collection chamber with door size of 400mm X 350mm & provision for periodic ash removal. The furnace shall have ceramic tiles finishing on the outer side. The front side of furnace will be covered by moving MS fabricated door lined with Insulation Bricks. Door operation will be the Mororised /manual.
Design Supply and Construction of Seconadary Chamber for the Re-Incineration Flue Gas having the inner Sixe of 400mmX1800mmX400mm. The Secondary Chamber shall be constructed with 4 Layers inner most will be 115mm IS-8 quality fire bricks (Dalmia Make only ) 2nd layer will be 115mm Hot face Insulation Bricks Rajestan Make 3rd layer will be75mm Cold face Insulation brick 4th layer will be 150mm Country Brick for the Outer Glazed tile provission to with stand temperature and insulation bricks to ensure minimum heat loss. High Alumina Fire Bricks backked with insulation bricks and the outter sixe of 1400mmX2100mmX700mm and the Providing of Flue Gas Entry and Outlet
Design, Supply, delivery and Erection of Chimney shall be fabricated out of MS material of thick 8/5 mm varying from bottom to top with bottom diameter shall not be less than 1000mm and top diameter 324 mm to a height of 30 m (min). Deisgn shall conform to IS 6533 norm and chimney shall be provided with accessories such as Ladder / Platform, Sampling Nozzle, Lightning Arrestor, Drain Plug, Bottom Door guy rope (6mm G.I galvanized wire rope) etc., and not restricted to only these complete system complying to Std norms. Chimney jointing flange gasket shall be provided by asbestos gasket instead of rubber flange gasket including testing and commissioning etc., complete.The Base Segment will the 1000mm to 800mm cone, second Segment will the 800mm to 600mm cone, Third Segment will be 600mm to 400mm Cone, Forth segment will be the 400mm to 325mm Cone, The Final Segment will be the 325mm straight Pipe. All the Segments length will be the 6000mm. All the Chimney Flanges Shall be 12mm thick. The Base Plate of the Chimney shall be 25mm thick plate
Duct Line From Cremation Chamber to Scrubbing Unit with Insulating of Refractory Cement The Outer Duct will be Made out of Mild Steel and the Inner will be Lined with Refractory Cement with the thickness of 50mm.the Outer Dia will be 400mm
Supply, Delivery and fixing of Centrifugal Fan should be the 10 HP Motor of suitable rating for Sucking of Fumes from the Furnce and letout to the Chimney in terms of Volumetric Flow Rate & Pressure Head development. The Impeller Should be the Stainless Steel SS-304 Grade and the Casing should be the Mild Steel 4mm thickness.The MoC shall be MS/SS as dictated by the Incinerator System operation
Duct Line From Scrubber to ID Fan Blower and ID Fan Blower and to the Chimney. The Duct will be Made out of Mild Steel construction with Flanges of 280mm to 325mm Dia
Supply and Installation Motorised Door Movement by using of Reduction gear and bearing Systems. The Motor will be 1/2 HP and the Reduction gear will the 1:150 Ratio for the Smooth Operation
Electrical Panel Board, Back, Electrical cables, Wiring etc., as directed by the departmental officers.The Panel Board will be capable for the Door Operation, Blower and Pump ON/OFF controls, and Burner Control Operations. The Total no. of 4 Burners will have individual Control Switch for Ignition and the Common Switch for the Blower Controls.The Control panel will be Neatly wired with Idienty marked Numbers and the cables for the Door will be the 1.5 Sq mm 3 core wire for the Suitable length from the Control panel o motor, The 4 Nos Burner Cable will the 1.5 Sq.mm 3 core suitable length from the control panel to Burners and the Motor will controlthe Limit with limit switches. The Fume Duct ID Blower cable will be the 4Sq.mm 3 Core cable from Controlpanel to Motor. The Control Panel Should have the MCB. Indicating Lamps, Push Buttons, ON/OFF Switches, Contactors, Temperature Controller, Over load Relays and Thermocouple etc..
LPG burner sets ECOFLAME make with LPG bank and control panel supply of 4Nos of burners with blower and fully auto control system. LPG fired ignition, flame sensor and auto cut off imcorporated in a separate controller equivalent to imported control system for air and LPG with auto ignition system and supply of 10 cylinder bank with pipeline from LPG cylinder back upto each burner end by using TATA; C class grade material pipe
Supply and Fixing of 2HP High Presure Pump for the Scrubbing System with Water Line Connections to the Scrubbing unit and Drain connections to the Tank
Supply and Fixing of Hydraulic Trolley with using of 2 Nos Hydraulic Pistons, The trolley should place at the floor Level for the loading of Human Body will have the Dimentions of 780mm width and 4500mm Length for the easy operation for the Loading of Human Body to the Cremation Chamber.
Supply of High Presure Stainless Steel Tube Burners with Suitable Lenth for the Cremation Chamber with having the Needle Valve, Non-Reurn Valveand Main Shutoff Valve etc…
High Pressure venturi Wet Scrubber for entrainment of particulate matters, removal of soluble emissions and sudden quench the emissions, fabricated out of mild steel. The emissions enter in to the scrubber having high-pressure water spray, there by entrained particulate matter is washed down with water with the removal of soluble emissions and also helping in the reduction of the Emission temperature. This system is provided within built RCC/masonry water storage cum circulation Tank. Necessary powerful centrifugal Pump for Circulation of water will be provided with Pipeline
Construction of structurally designed RCC framed building with steel structure of 6.10m inner width and 17.79 inner length. The crematorium hall foundation 10 columns raised upto lintel level ceiling height suitable for LPG gas crematorium proposed to be installed at Patchur graveyard in Municipality, Karaikal. The I sections size 150cmx75cm should be provided over the columns with base plate. Necessary truss is required with a span length of 6.10m with pitch height is 1.50m grill work is provided for around the crematorium building for proper ventilator for the 1.80m above lintel beam. Galvalume sheet for 450MPA is used for roofing with necessary gutters. The brick work upto lintel beam above basement level for a height of 2.70m with cement mortar 1:6 necessary lintel beam required for around the wall with a size of 0.23x0.15cm. All the RCC members should be 1:1 1/2 :3 concrete using OPC 43 grade cement and Fee 500 D steel reinforcement. Plastering should be in CM 1:6 of 12mm thick and 15mm thick outer plastering. The flooring should be Kotastone flooring 25mm thick with a base of cement mortar 1:4. The Kotastone should be laid over the base course of cement mortar 1:4. Finishing whould be in epoxy painting of three or more coats on exterior and water bound distemper of three or more coats in the interior ov+A14er a base coat of primer. The rolling shutter and windows should be of M.S sheets of minimum 1.6mm thick with suitable frames as directed by the Engineer-in-charge. Necessary ramp and steps should be provided. The rate should be quoted for gas storage room and scrubber with necessary pile foundation for 4 nos pile for 450mm dia and 4 nos of pile for 300mm dia for chimney foundation. Necessary pile cap should be provided for 450mm thickness. Brick work with 1:4 is provided upto basement above grade beam around scrubber room and gas storage room. The brick work above basement is CM 1:6 upto roof level with a height of 2.70m and 2.10m (sloped roof). The Galvalume sheet is provided for roofing with necessary purlin and rafters of size 60mmx40mm and 60mmx40mm respectively. The two nos of cross grade beam should be provided for scrubber room. Necessary 1:2:4 reinforced cement concrete is provided with a size 1.20mx1.20m for the base of chimney. Necessary electrification, plumping and sump should be provided. The rate is excluding the existing 10 nos of columns with dimension of 0.23mx0.23mx2.40m along with foundation brick work upto basement level including charges, walls, etc. The work should be carried out as per prescribed IS codes and standards and CPWD specification.
YES YES JEE ENGINEERING
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .