| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹70.7 L+₹2.7 L (3.91%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹79.4 L+₹11.4 L (16.7%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹85.4 L+₹17.4 L (25.5%)Rejected-Finance FLAT NO S 2 SHRI CHINTAMANI S NO 1 1148 MAHAJAN PETH MODEL COLONY SHIVAJI NAGAR PUNE 411016 | PUNE | PUNE | MAHARASHTRA | 411016 | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹85.7 L+₹17.6 L (25.9%)Rejected-Finance 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L5 | Rejected-Finance Not lowest |
Tender Value
₹79.9 L
EMD Value
₹1.4 L
Closing Date
18 Jul 2023, 6:00 pmClosed
Chief Engineer Rnd Secunderabad
Chief Engineer Rnd Opp Jubilee bus station Picket Secunderabad 500003
SPECIAL REPAIR FOR RENEWAL/REPLACEMENT OF VARIOUS BER E/M EQUIPMENT AT DIAT (DU) GIRINAGAR PUNE
2023_MES_603034_1
85318
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Girinagar
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Garrison Engineer I RnD Girinagar
₹1.4 L
Yes
29 Jan 2024
13 Jun 2023
25 Jul 2023
13 Jun 2023
18 Jul 2023
4 Jul 2023
Amount
Supply , installation, commissioning and testing water cooler electric driven (single phase),Fully Stainless steel having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour all as specified and directed.
Supply , installation, commissioning and testing wall mounted split air conditioner with inbuilt air ionizer & plasma filter for better indoor air quality with one cordless remote control unit,electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated with suitable heavy duty AC mounting bracket and suitable size of 3 core PVC cable from indoor to outdoor including removing old AC unit and depositing in MES store yard all as specified and directed.
Supply , installation, commissioning and testing wall mounted split air conditioner with inbuilt air ionizer & plasma filter for better indoor air quality with one cordless remote control unit,electric driven, single phase of capacity of 2.0 TR, BEE 5 star rated with suitable heavy duty AC mounting bracket and suitable size of 3 core PVC cable from indoor to outdoor including removing old AC unit and depositing in MES store yard all as specified and directed.
Supply and fix voltage stabiliser for automatic operation , single phase naturaly air cooled indoor type and designed for input variation between 170 to 270 volts with out put voltage stabilised at 230 volts with accuracy +/- 2.5% and of capacity 1KVA incl dismentling and disconnecting old UNSV voltage stabilizers and depositing in MES store yard all as specified and directed.
Supply and fix voltage stabiliser for automatic operation , single phase naturaly air cooled indoor type and designed for input variation between 170 to 270 volts with out put voltage stabilised at 230 volts with accuracy +/- 2.5% and of capacity 2KVA incl dismentling and disconnecting old UNSV voltage stabilizers and depositing in MES store yard all as specified and directed.
Supply and fix voltage stabiliser for automatic operation , single phase naturaly air cooled indoor type and designed for input variation between 170 to 270 volts with out put voltage stabilised at 230 volts with accuracy +/- 2.5% and of capacity 4KVA incl dismentling and disconnecting old UNSV voltage stabilizers and depositing in MES store yard all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep Five star rated with brushless direct current motor (BLDC) regulator type all as specified and directed.
Supply, installation, connecting and testing of storage type water heater, 25 litres capacity 5 star rated, with temperature adjustable knob and itemperature analogue displayincluding shock safe plug top, 02 Nos 2 feet steel hot and cold water connections including necesary all fixing arrangments suitable for working on AC single phase,230 V, 50 Hz including removing old geyser and depositing in MES store yardall as specified and directed.
Supply, installation, connecting and testing of storage type water heater, 50 litres capacity 5 star rated, with temperature adjustable knob and itemperature analogue display including shock safe plug top, 02 Nos 2 feet steel hot and cold water connections including necesary all fixing arrangments suitable for working on AC single phase,230 V, 50 Hz including removing old geyser and depositing in MES store yard all as specified and directed.
Supply, installation, connecting and testing refrigerators , electric driven , single phase, not less than285 litres, not less than 4 star rated all as specified and directed
Supply, install, testing and commissining, submersible pump set capacity not less than 60HP suitable for 415 V 3 phase of capacity pump set having head 108 meter and discharge 120 cum/hr (2000 LPM) complete with following accessories including lifting removing old pumpset and depositing in MES store yard all as specified and directed. (a) 3 core 25 sqmm submersible flat copper cable - Not less than 20 RM with sealent tape (b) FASD starter with ML6 contactors, relay range 110 amps, timer and etc -01 No (c) Necessary reducer, short piece flanged connections etc.
Supply, install, testing and commissining, monobloc pump set suitable for 415 V 3 phase of capacity not less than 5 HP,and pump having head 44 meter and 198 LPM , with necessary fixing arrangemements with following accesories including removing old pumpset and depositing in MES store yard complete all as specified and directed. (a) 3 core 2.5 sqmm submersible flat copper cable - Not less than 10 RM with sealent tape (b) DOL starter -01 No (c) Necessary reducer, short piece flanged connections etc.
Supply, install, testing and commissining submersible sewage pumpset not less than 30 HP 415 V 3 phase of capacity 47 Cum/Hr with 108 M head with necessary fixing arrangements including following accessories complete lifting removing old pumpset complete and handed over to MES office all as specified and directed. (a) 3 core 10 sqmm submersible flat copper cable - Not less than 20 RM with sealent tape (b) FASD starter with ML4 contactors, relay range 75 Amps, timer, ammeter and etc -01 No (c) Necessary reducer, short piece flanged connections etc.
Supply, install, testing and commissining, Pumping sets, centrifugal, electric driven with motor , capacity not less than 50HP and pump in DIAT Technical building basement including coupling complete assembly suitable for 415 V 3 phase discharge 1135 LPM and head 90 Meter ,PCC foundation including removing old pumpset complete from the basement of DIAT technical building and depositing in MES store yard all as specified and directed. (a) 3 core 25 sqmm copper XLPE LT cable - Not less than 20 RM with sealent tape (b) FASD starter with ML6 contactors, relay range 110 amps, timer, ammeter and etc -01 No (c) Necessary reducer, short piece flanged connections etc.
Supply, install, testing and commissining, Air blower AB-47 with capacity of 280-425 m3/Hr @0.5 kg/cm2 including suitable blower motor not less than 15.0 HP 3 phase motor with 1400 RPM Make for motor all as specified and directed. (a) 3 core 4 sqmm PVC insulated sheathed copper flexible cable - Not less than 10 RM with sealent tape (b) Suitable capacity Starter as directed by Engr-in-charge. (c) Necessary MS angle foundatio, masonary works, suitable motor starter,Flanges, Header, Elbow pipe connections, wires and etc including removing old pumpset complete and depositing in MES store yard all as specified and directed.
S&F copper tubing along with necessary insulation as per manufacture standard for 1.5/2.0 TR split AC unit, copper tubing pipe (1/4'')or(3/8") and (1/2'')or(5/8") as per OEM preferred size with necessary fiitings jointing for split type AC including provision of insulation on tubing all as specified and directed.
M&L for Cutting holes into or through brick/stone masonry walls, cement concrete slabs, chajjas, etc. reinforcedor otherwise for making hole for split AC piping including making good the disturbed sufaces and packing all as specified and directed.
UNITED ENGINEERING CORPORATION
somnath engineering corporation
Horizon Construction
Prasur Electricals & Engineering Co.
GKR and CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .