Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹34.4 L+₹5.4 L (18.7%)Rejected-Finance 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹35.0 L+₹6.0 L (20.7%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹38.9 L+₹9.9 L (34.2%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹40.4 L+₹11.4 L (39.3%)Rejected-Finance 24 A RAGHBIR MARG NEAR 22 NO PHATAK PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹89,980
Closing Date
30 Sept 2024, 6:00 pmClosed
LT COL SANDEEP KUMAR
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
REPAIR/MAINTENANCE OF LT NETWORK INCL LT PANELS,LT CABLES, LT OVERHEAD LINES IN SECTOR A MAP POCKET 5,8 AND 9 OF OLD CANTT UNDER GE (N) PATIALA
2024_MES_669750_1
GE (N)/TOKEN-46/2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
PATIALA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE NORTH PATIALA
₹89,980
Yes
30 Oct 2024
2 Sept 2024
2 Oct 2024
2 Sept 2024
30 Sept 2024
16 Sept 2024
Amount
Attending Complaints of locating the fault in LT line in OH/UG Line/cable by visual inspection recce of faulty area and repairs to the fault by means of replacement of Unservicible Jumpers / Fuse wires / Burnt lugs / MCCB/ Cable etc. inclusive o restringing of broken ACSR conductors/ Earth wire incl. taking out and relaying the same after defects rectification upto 5M length. Note : (i) Materials requried for fault repairs will be measured under relevant items included in BOQ. (ii) Contractor will depute the dedicated team, he will completely responsible for all the safety aspects of his team. No dispute regarding safety of person would be entertain later on. If any mishappening occures during rectifaction of fault in LT lines contractor will be fully liable to bear all the expenses of indls. Special Notes:- (a) Contractor will provide all set of T&P, communication device (Mobile Phone) to deployed persons/ electrician team as required for repair of LT Electrical switch gear system including safety equipment (Bamboo ladders, shorting rod, screw drivers, wire/cable cutters with blades, multi meters, cutting pliers, torch lights and rain coat etc.) for routine maintenance and protection of the trademan. (b) On intimation of any type of repair/maintenance work of LT switch gear incomer as well as out going feeder the contractor is responsible to locate the fault by the dedicated team comprising tradesman helpers required numbers as per the gravity /nature of the work involved to restore the power supply (not less than one electrician and one helper) and communicate with SBA on duty and getting permit card for working on LT lines and deposit the permit card after rectification of fault, all the activities shall be carried out within reasonable time as given by the Engr-in-Charge. (c) Contractor will provide necessary complaint slip, complaint boook & permit book, contractor will direct the instructions to indls for lodgging the complaints duly marked the location, time and date for earlier rectifications. (d) After getting the complaints, team deployed by the contractor will rectify the complaints within stipulated time i.e within 2 hours from the time of receiving of complaints. (e) Contractor should also provide a dedicated supervisor for collection of complaints from SBA, JE etc. He would be held responsible, in case complaints are not collected timely
M&L for Dismantling insulators any type, any size from LT poles complete all as specified and directed by Engineer in Charge.
M&L for Dismantling cross-arms of M.S. channel or angle sections etc from LT poles and setting aside for re-use with in 50m complete all as specified and directed by Engineer in Charge.
M&L pin type porcelain vitreous white/brown/green insulator including one galvanized mild steel spindle and two galvanized iron washer and nut complete suitable for 1100 V grade 100mm height 65mm dia.
M&L for shackle type porcelain vitreous, white brown or green insulator for working pressure 1.1 kv of size 75 mm height and 90 mm dia including galvanized mild steel straps of section 31 x 3 mm size 12 mm dia bolt nut and washers complete all as specified and directed .
M&L for Cross arms bracing supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shapes or sizes as indicated or directed and inclusive of one primer coat,one under coat and one finishing coat of paint.
M&L for Dismantling of ACSR conductors after unbinding from insulators
Supply and fixing of ACSR conductor of various size as per site requirement to be drawn straight horizontal on over head lines on existing poles including binding with insulators. Weight of conductor shall be measured straight horizontal distance between centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag ,jointing jumpers,etc complete all as specified and directed,
Supply and fix in replacmement LT spacer 02 way FIX type made out of PVC material and suitable to work on 1100 volts fixed between 02 conductors in any position along the LT line for any size of conductor along the feeder complete all as specified and directed.
Supply and fix in replacement LT spacer 05 way spiral type made out of PVC material and suitable to work on 1100 volts fixed between 05 conductors in any position along the LT line for any size of conductor along the feeder complete all as specified and directed.
Taking up or down 10 sqmm 2 core worn out/ damaged / partially serviceable/unserviceable PVC insulated underground cable, armoured, heavy duty with aluminium conductors 1100 volt grade from trench including taking out unserviceable bricks,pipes etc testing of cable in the presence of Engr-in-charge to ascertain seviceability,seggregating serviceable and unserviceable cable and keeping in safe custody the serviceable portion for reuse, stocking serviceable bricks for reuse complete all as specified and directed (Note: Earth work shall be measured and paid separately under relevant item of Sch 'A').
All as per item No. 11 here-in before but for cable of size 4 core 10 sqmm.
All as per item No. 11 here-in before but for cable of size 4 core 16 sqmm.
All as per item No. 11 here-in before but for cable of size 4 core 25 sqmm.
All as per item No. 11 here-in before but for cable of size 4 core 35 sqmm.
All as per item No. 11 here-in before but for cable of size 3.5 core 95 sqmm.
All as per item No. 11 here-in before but cable of size 3.5 core 120 sqmm.
Supplying, laying, jointing and testing in replacement in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 240 Sq mm including taking down old unserviceable cable complete all as specified .
All as per item No. 18 here in above but of size 3.5 core 185 Sqmm complete all as specified .
All as per item No. 18 here in above but of size 3.5 core 150 Sqmm complete all as specified .
All as per item No. 18 here in above but of size 3.5 core 120 Sqmm complete all as specified.
All as per item No. 18 here in above but of size 3.5 core 95 Sqmm complete all as specified.
All as per item No. 18 here in above but of size 3.5 core 70 Sqmm complete all as specified.
All as per item No. 18 here in above but of size 3.5 core 50 Sqmm complete all as specified.
All as per item No. 18 here in above but of size 3.5 core 35 Sqmm complete all as specified.
All as per item No. 18 here in above but of size 3.5 core 25 Sqmm complete all as specified.
All as per item No. 18 here in above but of size 4 core 16 Sqmm complete all as specified.
All as per item No. 18 here in above but of size 4 core 10 Sqmm complete all as specified.
Excavation in trenches not exc 1.5 m wide and not exceeding 1.5 m depth for foundation laying of cables etc and getting out in soft loose soil all as specified.
all as per item no 29 above but depth exceeding 1.5 n but n exc 3 m
Returning filling including spreading leveling watering and well ramming in layers n.exc 25 cm in soil completed all as specified and directed
Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point as in soil complete all as specified.
M&L river washed and screeened dry fine sand filling in trenches below and above / around under ground cable for cable protection including punniing around cable complete all as specified.
M & L for precast concrete cable covers type 2 flat, size 250mmx150mmx40mm laid dry in trenches for cable protection all as specified and directed by Engineer in Charge.
S&F GI tubing 80 mm bore light grade galavanised with all fitting complete for cable protection under road crossing/on pole/wall or similar position including taking down existing one complete all as specified.
All as per item no 35 here in above but of size 50mm bore complete all as specified.
All as per item no 35here in above but of size 40mm bore complete all as specified.
Making boring to road/cement path/hard standing for providing GI pipe 40/50/80 mm both end socketed for passing armoured cable incl making good the disturbed surface complete all as specified.
S&F end joint kit in replacement for 1.1 KV grade suitable for outdoor type terminal heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 185/240/300 Sq mm.
S&F end joint kit in replacement for 1.1 KV grade suitable for outdoor type terminal heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 70/150 Sq mm.
S&F joint kit in replacement kit for 1.1 KV grade suitable for straight through heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 185/240/300 Sq mm.
S&F joint kit in replacement kit for 1.1 KV grade suitable for straight through heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 70/150 Sq mm.
S&F joint kit in replacement kit for 1.1 KV grade suitable for straight through heat shrinkable type joints with jointing material for 4 core XLPE armoured aluminium conductor cable of size 25/35/50 Sq mm
S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 63 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 16 kA complete all as specified and directed.
S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 100 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 25 kA complete all as specified and directed.
S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 160 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 25 kA complete all as specified and directed.
S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 200 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 250 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 400 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
S&F in replacement of ACB Microprossessor relese based type 50Hz, 4 Pole 630Amp 50 KA,with electronic protection unit with LSI/LSIg+NEUTRAL O/L+OVER TEMPERATURE PROTECTION complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S
S&F in replacement of ACB Microprossessor relese based type 50Hz, 4 Pole 800Amp 70 KA,with electronic protection unit with LSI/LSIg+NEUTRAL O/L+OVER TEMPERATURE PROTECTION complete all as specified and directed. Make : Legrand/Schniders/Simens/ABB/L&T/Indo Asian/HPL/Havells/Standard/C&S
S&F in repalcement Bus Bar Chamber of size 30 x 30 x 15 cm suitable of 3 phase 433 Volts outdoor type and nuteral made out of 3.15 mm thick M S Sheet with 100 Amps rated aluminium busbar (4 Nos ) PVC sleeves and coloured (Red,Yellow,Blue and Black) with locking arrangments and fixing the busbar on the wall with necessary fixing arrangement complete alongwith all necesary cable connection with thimbles nut bolts etcs,lugs and cable gland including 2 coat of grey colour paint over a coat of red oxide primer all as directed.
All as item no 52 above but of size 60x60x45cm with 400Amps busbar complete.
Supply & fix incl taking down LT feeder pillar panel weather proof outdoor type double door fabricated cout of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7035( Siemens grey) shade with matt finish with seven tank pre treatment process.The panel shall be fabricated by CPRI approved manufacturer only.The panel shall be compartmentized designed totally enclosed ,dust & vermin proof,confirming to degree of protection IP-55, gasket between all adjacent units and beneath all covers shall be provided to render the joint dust proof. All doors and covers shall be provided with cyllendrical panel locked .The panel shall be provided with alluminium bus bars, electrolytic grade of adequate rating or as specified below.The bus bars and inter- connecting links shall be insulated with heat shrinkable PVC sleeve with RYB and black colour coding.The bus bar shall be supported on unbreakable, non hygroscopic, SMC insulated supports at sufficiently close interval to prevent bus bars sag and shall be housed in a dedicated compartment.The panel shall be prewired with FRLS PVC insulated coper conductors cables of suitable size properly tagged and secured. The panel shall be provided with digital Voltmeter/Ammeter with cast resign CTs & RYB LED indicating lamps at incoming. The panel shall be provided with heavy duty steel cable glands of adequate size for incoming & ali outgoing cables. The panel shall be provided with manufacturer name plate, skull & bone danger notice board etc. The panel shall be provided with 04 numbers 50 x 50 x 6 mm thick angle iron supports duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth at per site requirement.All MCCBs shall be provided with spreader links with phase seperator on both sided and suitable extended rotary handle for incoming MCCB complete all as specified and as directed. The panel shall be provided with and including the following accessories : - (a) Aluminium bus bar - 1200 Amps rating suitable for 3 phase 4 wire system. INCOMING:- (i) ACB Microprossessor relese based type 50Hz, 4 Pole 800Amp 50 KA,with electronic protection unit with LSI/LSIg+NEUTRAL O/L+OVER TEMPERATURE PROTECTION - 1 No (As incoming) (ii) Digital Ammeter 0-200 Amp-01 Nos (iii) Digital Voltmeter 0-500 Volt-01 Nos (iv) LED Indicating lamp R,Y, B-01 Nos OUTGOING:- (i) MCCB 4P -250Amps 36 KA breaking capacity with fixed thermal & fixed magnetic over load protection -02 Nos (ii) MCCB 4P -160Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection with - 04Nos
Supply & fix LT feeder pillar panel weather proof outdoor type double door fabricated cout of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7035( Siemens grey) shade with matt finish with seven tank pre treatment process.The panel shall be fabricated by CPRI approved manufacturer only.The panel shall be compartmentized designed totally enclosed ,dust & vermin proof,confirming to degree of protection IP-55,gasket between all adjacent units and beneath all covers shall be provided to render the joint dust proof. All doors and covers shall be provided with cyllendrical panel locked .The panel shall be provided with alluminium bus bars,electrolytic grade of adequate rating or as specified below.The bus bars and interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB and black colour coding.The bus bar shall be supported on unbreakable,non hygroscopic,SMC insulated supports at sufficiently close interval to prevent bus bars sag and shall be housed in a dedicated compartment.The panel shall be prewired with FRLS PVC insulated coper conductors cables of suitable size properly tagged and secured..The panel shall be provided with digital Voltmeter/Ammeter with cast resign CTs & RYB LED indicating lamps at incoming.Sthe panel shall be provided with heavy duty steel cable glands of adequate size for incoming & ali outgoing cables..the panel shall be provided with manufacturer name plate,skull & bone danger notice board etc. the panel shall be provided with 04 numbers 50mmx50 mmx6mm thick angle iron supports . duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth at per site requirement.All MCCBs shall be provided with spreader links with phase seperator on both sided and suitable extended rotary handle for incoming MCCB complete all as specified and as directed. The panel shall be provided with and including the following accessories : (a) Aluminium bus bar -400 Amps rating suitable for 3 phase 4 wire system INCOMING:- (i) MCCB 4P 400 Amps 36 KA breaking capacity with adjustable thermal & adjustable magnetic over load protection-01 Nos (ii) Digital Ammeter 0-200 Amp-01 Nos (iii) Digital Voltmeter 0-500 Volt-01 Nos (iv) LED Indicating lamp R,Y, B-01 Nos OUTGOING:- (i) MCCB 4P -160 Amps 25 KA breaking capacity with fixed thermal & fixed magnetic over load protection -02Nos (ii) MCCB 4P-250Amps 36 KA breaking capacity with fixed thermal & fixed magnetic-02 Nos
Supply & fix incl taking down LT feeder pillar panel weather proof outdoor type double door fabricated cout of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7035( Siemens grey) shade with matt finish with seven tank pre treatment process.The panel shall be fabricated by CPRI approved manufacturer only.The panel shall be compartmentized designed totally enclosed ,dust & vermin proof,confirming to degree of protection IP-55,gasket between all adjacent units and beneath all covers shall be provided to render the joint dust proof. All doors and covers shall be provided with cyllendrical panel locked .The panel shall be provided with alluminium bus bars,electrolytic grade of adequate rating or as specified below.The bus bars and interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB and black colour coding.The bus bar shall be supported on unbreakable,non hygroscopic,SMC insulated supports at sufficiently close interval to prevent bus bars sag and shall be housed in a dedicated compartment.The panel shall be prewired with FRLS PVC insulated coper conductors cables of suitable size properly tagged and secured..The panel shall be provided with digital Voltmeter/Ammeter with cast resign CTs & RYB LED indicating lamps at incoming.Sthe panel shall be provided with heavy duty steel cable glands of adequate size for incoming & ali outgoing cables..the panel shall be provided with manufacturer name plate,skull & bone danger notice board etc. the panel shall be provided with 04 numbers 50mmx50 mmx6mm thick angle iron supports . duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth at per site requirement.All MCCBs shall be provided with spreader links with phase seperator on both sided and suitable extended rotary handle for incoming MCCB complete all as specified and as directed.. the panel shall be provided with and including the following accessories : (a) Aluminium bus bar -600 Amps rating suitable for 3 phase 4 wire system INCOMING:- (i) Incoming MCCB 4P 250 Amps 36 KA breaking capacity with adjustable thermal & adjustable magnetic over load protection - 01 Nos (i) Digital Ammeter 0-200 Amp - 01 Nos (iii) Digital Voltmeter 0-500 Volt - 01 Nos (iv) LED Indicating lamp R,Y, B - 01 Nos OUTGOING:- (i) outgoing MCB 4P - 63 Amps 16 KA - 06
M&L in replacement earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected to and including galvanized earth lead strip 32X6 mm size upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and panel all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil, PCC(1:3:6) type C1 chamber, pre-cast RCC slab 50mm thick in cement concrete (1:2:4), type B1, reinforced with welded steel wire fabric or XPM, (weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, GI protection pipe,40mm dia,light grade, upto7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed.
Restretching properly and tightening ACSR conductor including rebinding aftes straining the single conductor on LT pole of any size replacing of jumpers if necessary all as directed by Engr-in-Charge.
Cutting vegetation and surface dressing not exceeding 15 cm deep including removing the materials to a distance not-exc 60 mtr complete. (Note :- Item shall be executed twice in each installation and quantity is given for two operation. However unit rate to be quoted by the tendered for single operation only)
M&L for triming of tree branches (touching HT/LT OH line)uptto 10cm girth at any height carefully taking shutdown including suitable disposal of cut of tree branches as in repair complete. Note:- tools & plants including safety measures equipments like belt,ladder & rops etc shall be arranged by the contractor at own cost.
Paint to existing steel tubular pole of any type complete with two coat of aluminium synthetic enamel paint from bottom to top of the pole including MS clamps, brackets, nuts and bolts with black and yellow paint upto 1.5 mtr height from bottom alternaterely strip 30 cm each including providing pole number with white enamel paint and 100 mm dia (round) background of blue enamel paint at site complete all as directed by Engr-in-charge.
Supply and fix in repairs erecting in true verticle position of steel tublar pole 9 Mtrs long complete with cast iron base plate finial taper plug bolt nuts and screws as as specified and of type 410 SP-31 conforming to relevent IS including two coats of aluminium paint over aone coat of red oxide primer to the full length of the pole and also two coats of bituminus paint inside outside of bottom portion upto 1.5 mtrs length and provide circular bend 32 mm dia 1 Nos of length 2 mtrs duly fixed with necessary clamp for mounting LED security light all as specified and directed by Engr-in-Charge. Note:- Excavation and PCC shall be measured and paid separetaly.
Supply and erecting in replacement LT PCC pole 9 mtrs long cross sectional 102 mm x 172 mm at top and 102 x 79 mm at bottom class 10 complying of relevent IS and painting the pole upto 5 feet from the ground level with black and yellow alternate strip of 30 cm each with synthetic enamel paint incl removing of broken pole debris all as specified and directed by Engr-in-charge. Note:- after commissioning of new pole contractor would liable to connect all the ACSR conductor to the new pole including insulators and cross arms etc inclusive in this unit rate.(ii) Excavation and PCC shall be measured and paid separetaly.
M &l for PCC 1:4:8 TYPE D-2 using 40 mm graded broken stone aggregate as in mass concrete in foundations etc . complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded broken stone aggregate as in mass concrete in foundations etc complete all as specified and directed .
Material and labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for coping around the pole strut above ground level, foundation of stay etc. including neccassory form work and finishing the surface fair and even without using extra cement all as directed and specified
M & L in replacement for GI strip 32 x 6 mm as earth continuity lead beyond test point fixed to wall on batten or recess or chases or buried in ground or drawn in conduit pipe complete all as specified and directed.
Arneja Builders (BID ID -3098851)
m/s s.n. builders (BID ID -3101916)
sanjeev enterprises (BID ID -3107260)
MAHESH KUMAR SINGLA CONTRACTOR (BID ID -3107434)
Jawandha Enterprises (BID ID -3108127)
SHARMA ELECTRICAL ENGINEERS (BID ID -3108463)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .