| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹15.3 L+₹32,735 (2.19%)Rejected-Finance RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹20.4 L+₹5.4 L (36.4%)Rejected-Finance | L3 | Rejected-Finance Rejected |
Tender Value
₹24.7 L
EMD Value
₹49,420
Closing Date
12 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
IMPROVEMENT TO SEWAGE SYSTEM AND PROVISIONING OF ASSOCIATED AT WAC (U), PROVN OF WALL MOUNTED, CEILING, PEDESTAL FANS
2022_MES_563544_1
GE/SP/ TOKEN-49/2022-23
Open Tender
Civil Works
Item Rate
120 days
Subroto Park Delhi Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹49,420
Yes
10 Feb 2023
16 Nov 2022
19 Dec 2022
16 Nov 2022
12 Dec 2022
30 Nov 2022
Amount
Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through and including non metallic rigid PVC concealed conduit, medium grade, ISI marked not less than 20 mm dia, concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal modular box powder coated of suitable size for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) For one wall mounted fan point controlled by one SP switch complete all as specified. Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
All as per item No 2 above but for one 3 pin 5 amps socket outlet on indipendent board with other switchs.
All as per item No 2 herein before but One socket outlet 5 Amps 5 Pin on same board with other switches
All as per item No 2 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including single core 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire connected to gang box of required size.
S&F switch piano, flush type single pole, one way, 5/6 Amps, 240 volts all as specified and directed at site.
S&F switch piano, flush type single pole, one way, 15 Amps, 240 volts all as specified and directed at site.
S&F socket outlet 5 pin 5 Amps all as specified and directed at site.
S&F socket 16 Amps, 2 in 1, flush type all as specified and directed at site.
Supply and fixing in replacement ceiling roses, surface bakelite 65x50mm ,3 terminals 3 phase, PVC/Polycarbonate, isolated body all as specified and directed at site.
M & L for in replacement submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified Note- 2 Runs of 4.0 Sqmm single core and one run of 4.0 sqmm single core cable shall be measured as one unit length.
Dismantling of unserviceable light fitting of any type and wattage from the buildings after disconnecting the electric supply and keeping in safe custidy for giving credit to the contractor all as specified and directed by engr-in-charge.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,10 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
S&F Exhaust fan 250 mm sweep 230 Volt, 1400 RPM including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCBs 10 KA breaking capacity, single pole, 240 volts, 6 to 40 amps C Curve capacity.
Supply and fixing in replacement MCBs 10 KA breaking capacity, single pole, and neutral, 240 volts, 63 amps C Curve capacity.
S&F wall mounting fan 450 mm sweep 230 Volt, rated motor speed not more than 1400 RPM, pull cord type 3 step regulator, pull cord type oscillation and mechanism for upwad and downword adjustment including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified.
S&F Exhaust fan steel body AC single 300 mm sweep 230 Volt, 1400 RPM with louver including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling fan heavy duty 1200 mm sweep, 230 Volt including necessary fixing arrangement for proper fixing/hanging as per site requirement complete all as specified and as directed by Engineer-in-Charge.
S&F pedestal fan heavy duty 450 mm sweep including necessary fixing arrangement for proper fixing/hanging as per site requirement complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 12 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. (Note :- MCB shall be measured and paid seperately.)
S&F MCB SP 6 to 32 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
S&F MCB SPN 40 Amps 10 KA, 240 volt 50 Hz 'C' Series all as specified and directed by engineer-in-charge.
Demolition of cement concrete (unreinforced) in ground floor and pavings n exc 15 cm thickness (below or above ground level) complete all as specified.
Demolition of brick work built in cement mortar incl all quoins, arches, pillars etc Complete all as specified.
Taking down cement plaster on brick walls built in cement mortar including raking out joints, hacking for key, scrubbing down with water etc complete all as specified.
M& L PCC, type B-1, 1:2:4 ( using 20mm graded crushed stone aggregate) as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, berms, road speed breakers not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating and including necessary form work, all as specified.
M&L for brick work with sub class 'B' bricks old size bricks strainght or curved on plan exc 6m mean radius built in CM 1 : 6 . Complete all as specified.
M&L for brick work with subclass B bricks, staright or curved on plan on plan to any redius in half brick thickness wall, biult in 1:4 cement mortar complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in hard / dense soil complete all as specified.
All as per item No 32 here-in-before but exc 1.50m and n exc 3.00m in depth.
M&L PCC 1 : 4 : 8 type D2 using 40mm graded stone aggregates as in foundation/bed of manholes,RCC pipes /posts etc complete all as specified.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1 : 4 mixed with water proofing compound finished even and smooth without using extra cement complete all as specified. (Water proofing compound shll be measure and paid separatelly).
Supply only liquid water proofing compound.
Extra for forming fair finished drain or channel 30 CM inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc.
M&L Rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces of walls, finished even and smooth ( without using extra cement) complete all as specified
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr In Charge.
S&F M S frame work such as grills,gratings etc and similar works all as specified .
M & L for preparation of new steel surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer.
M&L for reinforced concrete pipe class NP2,laid and jointed complete with collars of bore of pipe 450 mm.
M&L for concrete bed type C2, 1:3:6 for NP2 450mm pipes including packing under and haunching against the sides after they are laid and tested in all as specified and directed by Engineer-in-Charge
M& L for 80 mm thick, M-40 grade machine pressed precast colour concrete paver block in any shape and size as approved confirming to IS 15658-2006 complete all as specified and directed.
M&L Sand filling under floors or in foundation including watering and consolidtion as per specified.
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified.
Removing excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m from straight point outside of MOD land.
M&L Pre-cast cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) block masonry with solid blocks, exceeding 10cm in width as in kerbs stone and setting in cement mortar 1:4 complete all as directed by Engineer-in-charge.
M&L for preparing surfaces of new plaster on walls and applying two coats of cement base paint complete all as specified Over a coat of alkali resitant primer
SM CONSTRUCTION COMPANY
AARYANS GLOBAL INDIA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .