Loading…
Loading…
Tender Value
₹33.3 L
EMD Value
₹33,332
Closing Date
18 Feb 2026, 5:00 pmClosed
Executive Engineer Agril Northern Zone Horticultur
Executive Engineer Agril Northern Zone Horticulture
Construction of RCC Roof Godown At BLT EC Parjang District Dhenkanal
2026_DOH_125620_19
09/Hort. / NZ / 2025-26 Dt. 05.02.2026
Open Tender
Civil Works - Others
120 days
Parjang Dist Dhenkanal
Please Refer tender documents
2 documents required · 2 mandatory
₹6,000
Assistant Director Of Horticulture Kamakshyanagar
₹33,332
Yes
9 Feb 2026
9 Feb 2026
23 Feb 2026
9 Feb 2026
18 Feb 2026
9 Feb 2026
9 Feb 2026 - 13 Feb 2026
Earthwork in excavation of foundation in all kinds of soil within 50 m initial lead and 1.5 m initial lift including rough dressing and breaking rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 m in depth including cost and conveyance, royalty & taxes of all materials and cost of all labour T&P required for the work etc. complete as per the direction of the Engineer In Charge.
Supplying, Filling sand in foundation & plinth well watered and rammed including cost, conveyance, taxes, royalty of sand, labour & T&P etc. complete as per specification and direction of the Engineer In Charge.
Cement Concrete (1:4:8) by using 40 mm size hard granite crusher broken chips of approved quality and form approved quarry including lowering laying concrete, watering and curing etc. complete for required levels laid in layers including cost and conveyance, royalty & taxes of all materials and cost of all labour T&P required for the work including watering & curing, etc. complete as per the direction of the Engineer- in- charge.
Plain cement concrete (1:2:4) using 12mm size hard granaite crusher broken chips of approved quality and from approved quarry including lowering laying concrete,watering and curing etc.complete for required levels laid in layers including cost and conveyance,royality & taxes of all materials and cost of all labour T &P required for the work etc.complete as per the direction of the Engineer in charge.
Providing Fly Ash brick masonry work in using 230 mm X 110 mm X 80 mm in foundation (with dimensional tolerance of ± 2% ) Fly Ash bricks having crushing strength not less than 75 kg. / sq cm, mortar of mix 1:6 (1 cement : 6 sand) (Using Branded Cement), immersing the bricks for minimum 6 hrs in water before use, with all necessary projections, splay cutting, circular moulding, corbelling, etc., including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, watering, curing, sundries, tools and plants,etc. complete as per the direction of the Engineer In Charge.
Providing Fly Ash brick masonry work in using 230 mm X 110 mm X 80 mm in superstructure (with dimensional tolerance of ± 2% ) Fly Ash bricks having crushing strength not less than 75 kg. / sq cm, mortar of mix 1:6 (1 cement : 6 sand) (Using Branded Cement), immersing the bricks for minimum 6 hrs in water before use, with all necessary projections, splay cutting, circular moulding, corbelling, etc., including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, watering, curing, sundries, tools and plants,etc. complete as per the direction of the Engineer In Charge.
Reinforced Cement Concrete (M20 grade) with 20mm & down graded size hard granite crusher broken chips of approved quality and from approved quarry including centring, shuttering, lowering, laying concrete, watering and curing etc. complete for required levels laid in layers including cost, conveyance, royalty and taxes of all materials and cost of labour, T&P,required for the work etc. complete as per specification and direction for the Engineer In Charge.
Column Foundation
Plinth Band
Lintel Band
Roof Beam
Column
Chajja
Roof Slab
Supplying, fitting and placing MS round/ deformed/ tor steel HYSD bar reinforcement of only approved manufacturing companies of approved grade of required diameters of approved quality complete in proper position including cost of binding wire 18 to 20 gauge as per direction of Engineer In Charge.
2.5 cm tick grading concrete (1:2:2) on roof slab with 6 mm size hard granite chips. On new work of approved quality complete as per the direction of Engineer- in- charge.
6 mm thick cement plaster (1:4) to CC surface including closed deep chipping and cleaning to C.C. surface to receive cement plaster,watering and curing etc.complete with cost,conveyance,royalities,all taxes and cost of all materials and cost of all labour with T & P required for the work complete.
16mm thick cement plaster (1:6) to inside of brick walls surface after racking out the joints…curing and watering with all cost etc.complete
12 mm cement plaster in cement mortar (1:6) to outside including necessary scaffolding curing etc. in Foundation and Superstructure as per direction of Engineer In Charge.
Finishing walls with priming 1 coat with any approved primer complete as per the direction of the Engineer- in- charge.
Finishing walls two coats with plastic emulsion paint of approved shade complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work etc. complete as per direction of Engineer In Charge.
Fitting vitrified tiles in floors,treads or steps and landing on 25mm thick bed of cement mortar(1:1) joined with neat cement slurry mixed with pig ments including cost of tiles including cost of all material labour t&P etc. required for the work all complete as per direction of Engineer in Charge.
Fitting vitrified tiles in dadoes skirting and riser of steps on 12mm thick cement plaster(1:3) joined with neat cement slurry mixed with pigments to match the shade of tiles including rubbing &polishing complete including cost of tiles.
Supply and fixing of MCM Modified Clay Material - MCM R Series Brick (087089) - 222 x 63 mm of PHOMI make, as per company standard dimension, pattern, color as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation - Class A— ASTM E84- 15. The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate
Supplying, fitting and fixing of MS Fabricated Grills by using square bar 50 X 50 X 5 mm thick MS angle etc. as per approved specification complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work etc. complete
Priming one coat to steel surface with Red oxide over iron work complete including cost and conveyance and taxes of all materials and cost of all labour with T&P required for the work etc. complete as per the direction of the Engineer in charge.
Painting 2 coats with any approved enamel paint coat of shade over a coat of wall primer by means of brush to outside surface of walls after cleaning the surface including cost of material with all taxes and cost of all labour with T & P required for the work etc.complete in all respect.
Supplying, fitting, fixing up window (sliding type) made up aluminum Section 151-154, 151-155, as windows frame section No. 151- 155, 151-153 and 151-167 as shutter frame with 5mm thick black glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of materials all taxes labour, T&P etc
Filling Foundation and Plinth with excavated earth including watering and ramming to proper section 2/3 rd rate of respective item of work
Internal Electrical Work
Recresed wiring to light point/fan point/ exhaust fan point/ call bell point with 1.5 sq mm FR PVC insulated single standard multistandard copper conductor of ISI marked and ceilling rose ISI marked mounted on MS box having front modular cover of suitable size MS modular box with 1.0 sqmm FR PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer In Charge.
Group A
Group B
Supplying and fixing of 5/6 amp one way modular type switch on existing switch box/cover including connections etc as required.
Recessed writing to 5/6 amp socket oulet with 6 amp 250 V clip in modular type swich ISI marked mounted over GI modular box with face plate and cover of suitable size including all accessories complete as per direction of engineer in charge.
Supplying and fixing of 15/16 amp one way modular type switch on existing switch box/cover including connections including all accesories and connection as per direction of Engineer-in-charge.
Recessed wiring for 6 pin 15/16 amp modular socket outlet with 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer-in-charge.
Supplying and fixing batten holder/BK angle holder ISI marked including connection etc including all accesories and connection as per direction of Engineer-in-charge.
Installation, testing and commissioning of pre-wired 12 W LED Light fitting of all sizes complete with all accessories etc. directly on ceiling, excluding connection and earthing
Supply, Installation, Testing and Commissioning of 48 inch ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, etc. complete as per the direction for the Engineer in charge.
Installation, testing and commissioning of stepped type modular fan regulator, in existing switch box including connection with 1.5 sq. mm FR PVC insulated single core multistrand copper conductor, earthing the regulator
Supplying and fixing of 25 mm PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required.
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.18 MB
BOQ_580118.xls
BOQ • 0.29 MB
DTCN.pdf
Tender Documents • 0.91 MB
Download all tender documents and submit your bid