BILL OF QUANTITY
SUMMARY OF COST
SUMMARY OF COST - CIVIL WORKS
Amount Amount Total Amount
Amount Amount Total Amount
Sl.No. Description
(DSR-2023) (Non DSR) (DSR+NDSR)
SUMMARY OF COST - DISMANTLING & REBARRING WORKS
Amount Amount Total Amount
Amount Amount Total Amount
Sl.No. Description
(DSR-2023) (Non DSR) (DSR+NDSR)
1 DISMANTLING AND DEMOLISHING 1,40,642.29 - 1,40,642.29
SUMMARY OF COST - PLUMBING WORKS
Amount Amount Total Amount
Amount Amount Total Amount
Sl.No. Description
(DSR-2023) (Non DSR) (DSR+NDSR)
1 SANITARY FIXTURE & FITTINGS 22,270.90 5,490.00 27,760.90
3 INTERNAL WATER SUPPLY 7,45,478.74 1,91,165.00 9,36,643.74
SUMMARY OF COST - HEAT PUMP
Digitally signed by ARTI
Amount Amount Total Amount
Amount Amount Total Amount
Sl.No. Description
(DSR-2023) (Non DSR) (DSR+NDSR)
SUMMARY OF COST - HVAC SYSTEM
Sl.No. Description
(DSR) (Non DSR)
2 SUB-HEAD:- 3 PIPING WITH INSULATION 10,34,378.24 3,83,528.00 14,17,906.24
3 SUB HEAD:- 4 DUCTING & GRILLES - 19,22,606.09 19,22,606.09
4 SUB HEAD:- 5 INSULATION - 7,84,000.00 7,84,000.00
SUMMARY OF COST - HORTICULTURE & LANDSCAPING
Amount Amount Total Amount
Amount Amount Total Amount
Sl.No. Description
(DSR-2023) (Non DSR) (DSR+NDSR)
1 HORTICULTURE & LANDSCAPING 1,09,852.34 - 1,09,852.34
Digitally signed by ARTI
BOQ - Madhyanchal Bhawan - Civil Work
Project Name: “Repair and Renovation of Existing Building of Madhyanchal Bhawan Extension, Vasant Kunj, Delhi.”
SUMMARY OF COST - CIVIL WORKS
DSR Rate DSR Rate Amount Amount
S.No. Description of Work Unit Qty. Rate(@0.97
8.0 CLADDING WORK
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:
15622 (thickness to be specified by the manufacturer), of approved make,
in all colours, shades except burgundy, bottle green, black of any size as
approved by Engineer-in-Charge, in skirting, risers of steps and dados, over
12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and
jointing with grey cement slurry @ 3.3kg per sqm, including pointing in
white cement mixed with pigment of matching shade complete. Size 600 x
CLADDING WORK - SUBHEAD TOTAL 49,348.61 -
Providing and laying Vitrified tiles in floor in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and
conforming to IS:15622, of approved brand & manufacturer, in all colours
and shade, laid on 20 mm thick cement mortar
1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm
including grouting the joints with white cement and matching pigments etc.
The tiles must be cut with the zero chipping diamond cutter only . Laying of
tiles will be done with the notch trowel, plier, wedge, clips of required
thickness, leveling system and rubber mallet for placing the tiles gently and
11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size - -
FLOORING - SUBHEAD TOTAL 14,252.99 -
Digitally signed by ARTI
BOQ - Madhyanchal Bhawan - Civil Work
Project Name: “Repair and Renovation of Existing Building of Madhyanchal Bhawan Extension, Vasant Kunj, Delhi.”
SUMMARY OF COST - CIVIL WORKS
DSR Rate DSR Rate Amount Amount
S.No. Description of Work Unit Qty. Rate(@0.97
Providing and fixing false ceiling at all height including providing and
fixing of frame work made of special sections, power pressed from M.S.
sheets and galvanized with zinc coating of 120 gms/sqm (both side
inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x
1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to
centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x
50mm long with 6mm dia bolts, other flange of cleat fixed to the angle
hangers of 25x10x0.50 mm of required length with nuts & bolts of
required size and other end of angle hanger fixed with intermediate
G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to
centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm
with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm
centre to centre, shall be fixed in a direction perpendicular to G.I.
intermediate channel with connecting clips made out of 2.64 mm dia x 230
mm long G.I. wire at every junction, including fixing perimeter channels
0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the
perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450
mm centre, with 25mm long dry wall screws @ 230 mm interval,
including fixing of gypsum board to ceiling section and perimeter channel
with the help of dry wall screws of size 3.5 x 25mm at 230 mm c/c, including
jointing and finishing to a flush finish of tapered and square edges of the
board with recommended jointing compound , jointing tapes , finishing
with jointing compound in 3 layers covering upto 150 mm on both sides of
joint and two coats of primer suitable for board, all as per manufacturer's
specification and also including the cost of making openings for light
fittings, grills, diffusers, cutouts made with frame of perimeter channels
suitably fixed, all complete as per drawings, specification and direction of
the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095-
Digitally signed by ARTI
BOQ - Madhyanchal Bhawan - Civil Work
Project Name: “Repair and Renovation of Existing Building of Madhyanchal Bhawan Extension, Vasant Kunj, Delhi.”
SUMMARY OF COST - CIVIL WORKS
DSR Rate DSR Rate Amount Amount
S.No. Description of Work Unit Qty. Rate(@0.97
Providing and Fixing 15 mm thick densified tegular edged eco friendly light
weight calcium silicate false ceiling tiles of approved texture of size 595 x
595 mm in true horizontal level, suspended on inter locking metal grid of
hot dipped galvanised steel sections (galvanising @ 120 grams per sqm
including both side) consisting of main ‘T’ runner suitably spaced at joints to
get required length and of size 24x38 mm made from 0.33 mm thick
(minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size
24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced
between main’T’ at 600 mm centre to centre to form a grid of 1200x600
mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of
0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x
600 mm panel to from grid of size 600x600 mm, resting on periphery walls
/partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000
mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs
at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm
interval and laying 15 mm thick densified edges
calicum silicate ceiling tiles of approved texture in the grid, including,
cutting/ making opening for services like diffusers, grills, light fittings,
fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be
suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed
to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I.
adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm,
spaced at 1200 mm centre to centre along main ‘T’. Bottom exposed with
24 mm of all T-sections shall be pre-painted with polyster baked paint, for
all heights, as per specifications, drawings and as directed by Engineer-in-
ROOFING - SUBHEAD TOTAL 32,97,983.50 -
13.0 FINISHING
Distempering with oil bound washable distemper of approved brand and
manufacture to give an even shade
New work (two or more coats) over and including priming coat with cement
FINISHING - SUBHEAD TOTAL 3,47,361 -
Digitally signed by ARTI
BOQ - Madhyanchal Bhawan - Civil Work
Project Name: “Repair and Renovation of Existing Building of Madhyanchal Bhawan Extension, Vasant Kunj, Delhi.”
SUMMARY OF COST - CIVIL WORKS
DSR Rate DSR Rate Amount Amount
S.No. Description of Work Unit Qty. Rate(@0.97
22.0 WATER PROOFING
Providing and applying Membrane HDPE-S at 1.2mm thick, post applied
membrane on cured concrete, which bonds to a sound RC Concrete
substrate and also can be mechanically Anchored as required using
Aluminium nails with washer and top HDPE S can be wielded / patched
using sealed tape as patch. The Membrane HDPE-S, Self-Adhesive
membrane shall be supplied with one self-adhesive selvedge to provide the
overlap of previous sheet 75mm along the adhesive selvedge and along
with a comprehensive range of auxiliary products to simplify the application
1 NS-1 process. Membrane HDPE-S a self-Adhesive membrane Comply with British Sqm 1500.00 0.00 359.91 - 5,39,865.03
Standard 8102 2009 - Code of practice for “Protection of Structures Against
Water from the Ground” to provide basement waterproofing protection to
grades 1, 2 and 3. Membrane HDPE-S Membrane having Hydrostatic head
resistance more than 70m head of water (ASTM E 154), Tensile Strength
(ASTM D 412) – 17Mpa, & Breaking elongation @HDPE backing > 400%
(ASTM E 154) and Water migration 0 - 7 MPa (no migration), complete as
per manufactures specification. Measurements shall be considered as Wall
Providing and laying water proofing treatment in sunken portion of WCs,
bathroom etc., by applying cement slurry mixed with water proofing
cement compound consisting of applying : a) First layer of slurry of
cement @ 0.488 kg/sqm mixed with water proofing cement compound
@ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second
layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing
cement compound @ 0.126 kg/sqm. This layer will be allowed to air
cure for 4 hours followed with water curing for 48 hours. The rate
includes preparation of surface, treatment and sealing of all joints, corners,
junctions of pipes and masonry with polymer mixed slurry.
WATER PROOFING - SUBHEAD TOTAL 9,005.84 5,39,865.03
Digitally signed by ARTI
Project Name: “Repair and Renovation of Existing Building of Madhyanchal Bhawan Extension, Vasant Kunj, Delhi.”
TITLE: SUMMARY OF COST FOR PLUMBING WORK
S.NO. DESCRIPTION UNIT QTY.
Rate Rate(@0.973) Amount Rate Amount
I SANITARY FIXTURES & CP FITTINGS
All porcelain sanitaryware, CP fittings and accessories as specified below will be supplied free of cost to
the contractor at site. The supply will be as made by the manufacturer/vendor as their standard supply.
Contarctor will include providing and fixing of all other accessories like W.C Chairs/CP bolts, nuts, fisher /
Note: anchor bolt are required for hangong of WC, bends, Rubbers, W.C Connectors, brackets, nuts, bolts and
S.S Screws, sealent & White cement, sand stone aggregate, extension pieces, fixing devices etc. in the
respective item rates for the same in his tender. No extra payment on this account will be admissible under
any circumstances.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat
and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device
(handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making
good the walls and floors wherever required :
17.2.1 W.C. pan with ISI marked white solid plastic seat and lid Each 2 6515.55 6339.63015 12679.26
Providing and Fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm PTMT waste of
standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever
require : White Vitreous China Wash basin size 550x400 mm with single PTMT pillar cock.
Fixing, testing and commissioning of CP brass central hole wash basin mixer (table mounted) without
1 popup waste with 450mm long braided hoses & brass nuts casted spout complete including cutting and Each 2 500.00 1000.00
making good wherever required.
18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality
conforming to IS:8931
Fixing, testing and commissioning of CP Brass 115mm long Shower Arm with wall flange and pressure
2 adjustable Shower Rose complete with all accessories as required and making good the walls wherever Each 2 250.00 500.00
Fixing, testing and commissioning of CP Brass Bath and Shower Mixer with provision of overhead
3 shower with 115mm long bend pipe, in built spout, spout/shower selector with wall flange complete with all Each 2 250.00 500.00
accessories as required and making good the walls wherever required.
Digitally signed by ARTI
S.NO. DESCRIPTION UNIT QTY.
Fixing, testing and commissioning of C.P. brass divertor (4 way) with concealed stop cocks, over head
4 shower and bath spout complete including cutting and making good the walls wherever required. Each 2 500.00 1000.00
Fixing, testing & commissioning of Health faucet in PVC Flexible Tube with wall hook. (Spray unit, Flexible
5 Hose and cructh will be supplied.); a) one Number PVC flexible tube of 1.2 m length fitted with wall flange.; Each 2 250.00 500.00
b) Hand operated spray unit (instant type).
Fixing satin finish stainless steel AISI 316 grade wall mounted toilet paper holder including cutting and
making good the walls complete.
Fixing satin finish stainless steel AISI 316 grade wall mounted liquid soap dispenser with indicator
7 having bottom trough of soap complete in all respects, including cutting and making good the wall Each 2 250.00 500.00
wherever required.
Fixing ABS/Plastic body paper towel dispenser complete with brackets fixed to wall with PVC rawl plug
8 with CP brass screws complete in all respects, including cutting and making good the wall wherever Each 0 250.00 0.00
Fixing, texting and commissioning of storage type electric hot water heater made out of heavy gauge steel
jacket finished with rust proof baked-on glossy white enamel paint, inside glass lined heavy gauge steel
tank, 25 mm thick polyurethane foam insulation, thermostatically controlled immersion heater with pilot
9 neon lamp, replaceable magnesium anode bar, suitable for 8.0 bar maximum working pressure, cold water
inlet and hot water outlet pipe, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all
respect including testing etc. (Horizontal/Vertical)
a.) 25 litres capacity Each 2 495.00 990.00
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610
x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet
from back side, including fixing to wall with suitable brackets all as per manufacturers specification and
direction of Engineer-in-charge.
TOTAL CARRIED TO SUMMARY 22270.8997 5,490.00
II SOIL, WASTE & VENT PIPING
Providing, fixing , testing & commissioning of uPVC SWR pipes confirming to IS 13592 (Type B) alongwith
all required fittings like tees, bends, crosses, reducers, end caps etc. with or without access doors jointed
with approved solvent cement as per manufacturer's recommendations, including fixed to walls and
ceilings with material like pipe supports with powder coated galvanised MS slotted angle iron angles,
clamps, angles, nuts, bolts and under floor complete including cutting and making good the floors and
walls where required complete of outer diameter.
Digitally signed by ARTI
S.NO. DESCRIPTION UNIT QTY.
Providing, fixing, testing & commisioning of uPVC pipes, conforming to IS 4985 including injection
moulded fittings, jointing with solvent cement, cutting and making good the floors and walls and jointing to
trap/waste pipe complete in all respects as directed by Engineer-incharge complete as per standard
2.1 40 mm OD (class 3 (6 kg/cm2) Metre 4 400.00 1600.00
2.2 63 mm OD (class 3 (6 kg/cm2) Metre 2 300.00 600.00
Providing, fixing and testing of PP white P Trap (Floor Trap) with 50mm water seal with rubber seal on inlet
3 to push fit hopper for indirect waste connections and making good the walls, floors etc. complete in all
respects as directed by Engineer-incharge complete as per standard design.
Providing, fixing and testing of uPVC multi inlet hight riser fittings with 3 or 4 side inlets of 40/50/63 mm
4 size and fixed to CI/PP/uPVC traps with drip seal/m-seal/solvent cement joint complete in all respects as Each 2 400.00 800.00
directed by Engineer-incharge complete as per standard design.
Providing and fixing, testing and commissioning of 110 OD uPVC reducing Tee for inlet connection with of
5 63 mm size, and fixed to CI/PP/uPVC traps with drip seal/m-seal joint complete in all respects as directed Each 1 250.00 250.00
by Engineer-incharge complete as per standard design.
Providing and laying cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate
20 mm and down gauge) 75 mm in bed and all round uPVC soil and waste pipe under floor including
shuttering and centering complete in all respects as directed by Engineer-incharge complete as per
standard design.
6.1 Pipe 40 to 63 mm dia Metre 3 500.00 1500.00
Providing, fixing and testing of reducing floor drain of 110x63 mm OD as floor drain in cement concrete 1 :
7 2 : 4 float with floor complete in all respects as directed by Engineer-incharge complete as per standard Each 2 500.00 1000.00
Providing and fixing 125 mm dia, 1 mm thick CP grating with frame for floor traps or drains of required
9 pattern including cutting and making good the floors complete in all respects as directed by Engineer-
incharge complete as per standard design.
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement :
19.27 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per
standard design :
19.271 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 0 5957.9 5797.0367
TOTAL C/F TO SUMMARY 10,750.00
III INTERNAL WATER SUPPLY
Digitally signed by ARTI
S.NO. DESCRIPTION UNIT QTY.
Providing and fixing chlorinated polyvinly chloride (CPVC) CTS SDR 11 hot & cold water pipes conforming
to IS capable to withstand 27.6 kg/cm² at room tempreature water and 7.03 kg/cm² at 82°C and all fittings
of CPVC SDR 11 like elbow, tee, reducers, couplers, brass threaded male & female (adapoters, elbow,
18.8 tees). The pipe fitting joining to be done with solvent cement as per manufacturers specifications &
recommendations. The above includes chaise cutting fixing of pipes fittings testing of assembley and
finally making good the wall to the satisfaction complete in all respects as directed by Engineer-incharge
complete as per standard design.
CONCEALED DOMESTIC & FLUSHING PIPING (IN TOILET)
Providing, fixing, jointing, testing & commissioning of GI pipes and fittings conforming to IS:1239 (heavy
class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and
making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager,
complete in all respects for internal works) including pipe supports with walls and ceilings including pipe
supports with powder coated galvanised MS slotted angle iron angles, clamps, nuts, bolts, painting of
exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red
oxide zinc cromate primer including painting of legends in English with direction arrows, disinfecting water
mains by flushing with water containing bleaching powder @ 0.5 gms per litre of water and cleaning the
same with fresh water, operation to be repeated three times including getting the sample of water from the
disinfected main tested in the municipal laboratory complete including cu), complete as per manufactures
specification. Measurements shall be considered as W
EXPOSED DOMESTIC & FLUSHING PIPING (IN SHAFT VERTICAL)
18.10.2 20mm dia nominal bore Metre 312 437.3 425.4929 132753.78
18.10.3 25mm dia nominal bore Metre 416 551.7 536.8041 223310.51
18.10.4 32mm dia nominal bore Metre 208 667 648.991 134990.13
18.10.5 40 mm dia nominal bore Metre 104 811.9 789.9787 82157.78
EXPOSED PIPING FOR DOMESTIC & FLUSHING WATER, ( IN TERRACE )
18.10.4 32mm dia nominal bore Metre 0 667 -
18.10.5 40 mm dia nominal bore Metre 51 811.9 789.9787 40288.91
1.3 65mm dia nominal bore Metre 69 1250.0 86250.00
1.4 80mm dia nominal bore Metre 23 1400.0 32200.00
Providing, fixing, testing & commissioning of full bore brass ball valve (PN 25) with stainless steel (SS) ball
inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete in all
respects as directed by Engineer-incharge complete as per standard design. Tested to 40 kg/cm 2 hyd.
Digitally signed by ARTI
S.NO. DESCRIPTION UNIT QTY.
Supply, installation, testing & commissioning of slim seal wafer type butterfly valves class (PN 1.6) with
stainless steel (SS) disc complete with matching flanges, EPDM rubber insertion, nuts, bolts and washer
etc. of following sizes. (IS: 13095) complete in all respects as directed by Engineer-incharge complete as
per standard design.
TOTAL C/F TO SUMMARY 7,45,479 1,91,165.00
Digitally signed by ARTI
BOQ - Madhyanchal - Dismantling Rebarring Works
BILL OF QUANTITIES
Project Name: “Repair and Renovation of Existing Building of Madhyanchal Bhawan Extension, Vasant Kunj, Delhi.”
DSR Rate Rate(@0.9 Rate Amount Amount
S. No. Description of Item Unit Qty.
C. DISMANTLING AND REBARRING
DISMANTLING AND DEMOLISHING
Actual work of Dismantling and demolition to be taken care of as per the site condition and approval.
Dismantling tile work in floors and roofs laid in cement
1.0 15.23 mortar including stacking material within 50 metres 0.00 0.00
i 15.23.1 For thickness of tiles 10 mm to 25 mm Sqm 50.00 73.40 71.42 3570.91 0.00
Dismantling aluminium/ Gypsum partitions, doors,
windows, fixed glazing and false ceiling including
2.0 15.57 disposal of unserviceable material and stacking Sqm 2500.00 56.35 54.83 137071.38
of serviceable material with in 50 meters lead as
directed by Engineerin- charge.
Total Carried Over to Summary ₹ 1,40,642.29
Digitally signed by ARTI
BOQ - Madhyanchal Bhawan - Heat Pump
Project Name: “Repair and Renovation of Existing Building of Madhyanchal Bhawan Extension, Vasant
ESTIMATED COST OF SOLAR WORKS & HEAT PUMPS
S.No. Description Unit Qty DSR - Rate Rate (NS) Amount (NS)
1 Supply, installion, testing and commissioning of Packaged type Water to
Water Heat Pump. These units shall be completely factory assembled
including 2 Nos. Scroll Hermatically Sealed Scroll / Reciprocating
Compressor(s), evaporator, Condenser and Microprocessor Control Panel
etc with R134a / 410 a Referigerant and COP between 3-4. The Heat Pump
shall have inbuilt hot water heat exchanger, vibratipon isolators, pumps,
valves, expansion valve, Copper / Aluminium fins, and other
accessories.The Heat Pump should be capable of producing hot water at
minimum 55°C temperaure at outlet (condenser circuit) temperatures at
30°C ∆T. The Machine should have an operating ambient temperature
range of 0°C to 50°C. Location: Terrace. (1 Working + 1 Standby)
Heating capacity : Approx. 134.0 kW (Thermal Output)
Input Power : Approx. 2 X 27.0 kW (2 Nos. 1 W + 1S)
Hot Water Outlet Temperature : 55 deg C
Peak Water flow : Approx. 2250 LPH
a. Built in electric panel as per safety norms as manufacturer standard.
b. All other mountings, fittings & controls with all accessories and
c. All other mounting, fittings and controls.
d. Suitable for electric supply of 415 + 10% volts & 50 Hz.
Digitally signed by ARTI
BOQ - Madhyanchal Bhawan - Heat Pump
Project Name: “Repair and Renovation of Existing Building of Madhyanchal Bhawan Extension, Vasant
ESTIMATED COST OF SOLAR WORKS & HEAT PUMPS
S.No. Description Unit Qty DSR - Rate Rate (NS) Amount (NS)
e. All interconnecting wiring / cabling between heat pump and electrical
f. The Heat pump shall have an in-built facility to start / stop depending
on variation in demand at different periods. Each 2 6,50,000 1300000
Plate type Heat Exchangers of 115500 Kcal/Hr Heat Transfer capacity,
(thermal output) (approx.) with Secondary 1 Set (1W+1S) heat transfer
horizontal centrifugal pumps (to be located at terrace level/or as per site
2 conditions) of 10 m head, 180 LPM of reqd. H.P & IE-2 class motor with
brass impeller, SS-304 shaft & CI casing (or as per manufacturer's
standards meeting our technical parameters).
3 Hot Water Mixing Tank
Supply, installation, testing & commissioning of Corrosion Resistant Glass
Lined Tank according to German DIN 4753 with magnesium anode rod for
protection, heavy duty steel, factory fitted thermometer, with PU foam
jacket of min 100mm thickness, suitable for external heater element
mounting upto 100 kW, with access and maintetnace openings, suitable
for 10 bar pressure and 95 deg C Temeperature. Tank shall be provided
with hot water flow meter at inlet & outlet (approved by department of
weights and measures), inlet / outlet, overflow / drain connection with MH
cover (550 mm I.D.) pressure relief valves, pressure gauge at inlet / outlet
with isolation cock, thermometer at inlet / outlet. All the valves &
accessories shall be suitable for an operating pressure as mentioned above.
Digitally signed by ARTI
BOQ - Madhyanchal Bhawan - Heat Pump
Project Name: “Repair and Renovation of Existing Building of Madhyanchal Bhawan Extension, Vasant
ESTIMATED COST OF SOLAR WORKS & HEAT PUMPS
S.No. Description Unit Qty DSR - Rate Rate (NS) Amount (NS)
Capacity : - 3000 Lts.
Hot water mixing tank complete with insulation & MS supporting
structure with access ladder duly paint with red oxide comprising of
Cold Water inlet PN 16 Butterfly / Globe Valve. - 1 Nos.
Cold Water inlet lineCheck Valve. - 1 Nos.
Hot water inlet / outlet.
PN16 Butterfly / Globe Valve. - 2 Nos.
PN:16 Butterfly / Globe Valve - 1 Nos.
PN:16 Butterfly / Globe Valve - 1 Nos.
Spare outlet - PN:16 Butterfly / Globe Valve - 1 Nos.
Hot water return inlet Flanged 40 mm dia Bronze Globe Valve - 1 Nos.
Tank Drain connection PN 16 Ball Valve - 1 Nos.
Temperature sensor at mixing tank suitable for differential temperature
setting shall be made for start / stop of the HWG and other. The control
system shall be complete with necessary cabling / wiring along with
support. - 2 Nos.
4 Water Transfer Pumps - 0
Digitally signed by ARTI
BOQ - Madhyanchal Bhawan - Heat Pump
Project Name: “Repair and Renovation of Existing Building of Madhyanchal Bhawan Extension, Vasant
ESTIMATED COST OF SOLAR WORKS & HEAT PUMPS
S.No. Description Unit Qty DSR - Rate Rate (NS) Amount (NS)
Providing, installation, testing & commissioning of following insulated
pumps suitable for 415 Volts connected with TEFC induction motor, DOL
starter, MS channel, base plate complete with vibration isolators, isolating
valve on suction and discharge, non return valve on discharge, Y strainer
on suction, pressure gauges with stop cock and dial type thermometer on
suction or discharge. The pump shall have mechanical seal. The pump shall
be SS casing, impeller, shaft & CI (epoxy coated) base (suitable for hot
water temperature)
4.1 Domestic Hot Water Primary Pumps - 0
Pump - 2 No. (1W + 1 SB) - 0
Flow - 180 LPM - 0
4.2 Domestic Hot Water (From Heat Pump To Mixing Tank) - 0
Pump - 2 No. (1W + 1 SB) - 0
Flow - 120 LPS - 0
4.3 Domestic Hot Water Transfer Pumps - 0
Pump - 2 No. (1W + 1 SB) - 0
Flow - 180 LPM - 0
Digitally signed by ARTI
BOQ - Madhyanchal Bhawan - Heat Pump
Project Name: “Repair and Renovation of Existing Building of Madhyanchal Bhawan Extension, Vasant
ESTIMATED COST OF SOLAR WORKS & HEAT PUMPS
S.No. Description Unit Qty DSR - Rate Rate (NS) Amount (NS)
5 Providing, jointing, testing & commissioning of following sizes of ERW
heavy class MS pipes conforming to IS-1239 with all accessories like all
fittings including tees, elbows, reducers, union, flanges, rubber gaskets,
washer including galvanised supporting / fixing the pipe on floor / wall
/ceiling with clamps, hangers (using anchor fastners) as per specification.
GI pipe sleeve of suitable higher size shall be provided wherever the pipes
are crossing the walls / floors and sealing the sleeves with glass wool in
between & fire sealent compound at either end all as per Project Manager’s
/ Consultants requirements including cutting holes and chases in brick,
RCC work and making good the same to original conditions complete in
5.1 All hangers, clamps, brackets etc. shall be of galvanized iron and floor
supports with vertical pipes unless specified otherwise and then supply of
the same shall also be included for rates under this head. Cost shall be
inclusive of providing roller / slide support, expansion loops and wooden
brackets / blocks for insulated pipes.
Digitally signed by ARTI
BOQ - Madhyanchal Bhawan - Heat Pump
Project Name: “Repair and Renovation of Existing Building of Madhyanchal Bhawan Extension, Vasant
ESTIMATED COST OF SOLAR WORKS & HEAT PUMPS
S.No. Description Unit Qty DSR - Rate Rate (NS) Amount (NS)
6 BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber
Seal & O- Ring PN 16 pressure rating for chilled water/hot eater
circulation as specified - 0
7 Providing and fixing of Non IBR , Non Return Valve (on hot water line)
having bronze body, SS working parts with screwed ends suitable for
handling hot water. - 0
8 Providing & fixing insulation to Hot Water pipes & fittings in
accordance with specifications rockwool section pipe 60 kg/m³ density
with aluminum cladding of 24 G. - 0
8.1 Pipes in False Ceiling / Shaft / Plant Room - 0
Digitally signed by ARTI
BOQ - Madhyanchal Bhawan - Heat Pump
Project Name: “Repair and Renovation of Existing Building of Madhyanchal Bhawan Extension, Vasant
ESTIMATED COST OF SOLAR WORKS & HEAT PUMPS
S.No. Description Unit Qty DSR - Rate Rate (NS) Amount (NS)
9 Providing and fixing insulated pressure reducing station for cold water
supply comprising of 2 Nos Gun Metal ball valves on inlet & outlet & 1 no.
globe valve for by-pass 1 No pressure reducing valve with flanged /
screwed connection, 1 No. `Y' strainer, 2 Nos Pressure gauge on inlet
& outlet, and 1 No. 15 mm dia safety valve. The complete system is tested
to a pressure not less than 15 Kg/Sq.cm and suitable to reduce the pressure
upto 2 Kg/Sq.cm) Including necessary pipe & fittings; i.e. flanges/ unions,
nuts, bolts and washers complete as required.
9.1 65 mm dia (CI Housing - PRV) No. 1 60,000 - 60000
10 ELECTRICAL INSTALLATION FOR HOT WATER SYSTEM
Digitally signed by ARTI
BOQ - Madhyanchal Bhawan - Heat Pump
Project Name: “Repair and Renovation of Existing Building of Madhyanchal Bhawan Extension, Vasant
ESTIMATED COST OF SOLAR WORKS & HEAT PUMPS
S.No. Description Unit Qty DSR - Rate Rate (NS) Amount (NS)
10.1 Design, fabrication, assembling, wiring, supply, installation, testing and
commissioning of motor control centre shall be fabricated out of 14
gauge CRCA sheet steel in form in 3b formation with reinforcement of
suitable size angle iron, channel ‘T’ sections irons and / or flats wherever
necessary. Cable gland plates shall be provided on top as well as at the
bottom of the panels. Panels shall be treated with all anticorrosive
process before painting as per specifications with 2 coats of red oxide
primer and final approved shade of powder coated paint. 2 No. earthing
terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system.
Lifting hooks shall also be provided in case of large panels. Approval
shall be taken for each panel before fabrication. Cadmium Plated
hardware shall be used in fabrication of panels. Quoted rates shall
inclusive of cables, cable trays, earthing (in accordance to specification)
with earthing from panel to each motor / equipment.
MCC –1 for HEAT PUMP SYSTEM - 0
150 amps TPN MCCB with the following accessories: - 0
a. 0-450 volts 96 x 96 mm square voltmeter with selector switch
protected by 2 amps TP MCB. 1 Set - 0
b. 0-150 amps 96 x 96 mm square ammeter with selector switch and
100/5 amps 10 VA CL:1 CTs. 1 Set - 0
Digitally signed by ARTI
BOQ - Madhyanchal Bhawan - Heat Pump
Project Name: “Repair and Renovation of Existing Building of Madhyanchal Bhawan Extension, Vasant
ESTIMATED COST OF SOLAR WORKS & HEAT PUMPS
S.No. Description Unit Qty DSR - Rate Rate (NS) Amount (NS)
c. Phase indicating lamps protected by 2 amp SP MCB 3 Set
200 amps TPN (50 KA) aluminium bus bar with heat shrinkable
insulation sleeves. - 0
Outgoings - 0
a. 2 No. 100 amps TPN MCCB outgoing feeder to 2 Set. Heat Pump
b. 2 No. suitable rating MPCB for 2.5 KW DOL starter and outgoing
feeder to (Domestic Hot Water Primary Pumps, (including 1No.
standby). Each compartment shall contain auto / manual selector
swtich and indicating / push button lamps with MCB for ON / OFF /
c. 2 No. suitable rating MPCB for 2.5 KW DOL starter and outgoing
feeder to (From Heat Pump To Mixing Tank, (including 1No. standby).
Each compartment shall contain auto / manual selector swtich and
indicating / push button lamps with MCB for ON / OFF / TRIP of
Digitally signed by ARTI
BOQ - Madhyanchal Bhawan - Heat Pump
Project Name: “Repair and Renovation of Existing Building of Madhyanchal Bhawan Extension, Vasant
ESTIMATED COST OF SOLAR WORKS & HEAT PUMPS
S.No. Description Unit Qty DSR - Rate Rate (NS) Amount (NS)
d. 2 No. suitable rating MPCB for 2.5 KW DOL starter and outgoing
feeder to (Domestic Hot Water Primary Pumps, (including 1No.
standby). Each compartment shall contain auto / manual selector
swtich and indicating / push button lamps with MCB for ON / OFF /
e. 125 amps TPN MCB’s 1 No. (For heat plate exchange) - 0
d. Spare MCB’s of following capacities: - 0
i. 40 amps TPN MCB’s 1 No. - 0
ii. 63 amps TPN MCB’s 1 No. - 0
Necessary cable alleys, internal wiring, and interlocking, earthing for all
equipment shall also be included. - 0
Notes: a. All MCCBs shall be of 25 KA breaking capacity and suitable for motor
duty application. - 0
b. Provision shall be made for providing potential free contacts to all pumps starters
for connection to BAS - 0
c. Provision shall be made to ensure system protection from dry running of the pump - 0
10.1.1 MCC - 1 For Plumbing System as described above. Set 1 1,39,585 - 139585
Digitally signed by ARTI
BOQ - Madhyanchal Bhawan - Heat Pump
Project Name: “Repair and Renovation of Existing Building of Madhyanchal Bhawan Extension, Vasant
ESTIMATED COST OF SOLAR WORKS & HEAT PUMPS
S.No. Description Unit Qty DSR - Rate Rate (NS) Amount (NS)
10.2 Supply and fixing in position 1 m wide Insulation mat made of
elastomeric polymers Material (Class -A) of 415V grade as per IS 15642-
2006 . Thickness of insulation mat shall be not less than 2 mm to
withstand 1.1 KV dielectric strength AS PER IS 15652 : 2006. It should
be complete as per specifications & directions of Engineer-in-charge. It
should be complete as per specifications & directions of Engineer-in-
10.3 Supply and fixing in position the best quality Danger Boards of
approved shape and size as specified by Local Electricity Authorities
written in English & Local Languages. No. 1 500 - 500
10.4 Supply and fixing in position the approved “Shock Treatment Charts”
written in English and Local Language. These charts shall be framed in
teak wood frame and covered with glass. No. 1 1,500 - 1500
TOTAL CARRIED TO SUMMARY 0 2539330
Digitally signed by ARTI
TITLE: HVAC BILL OF QUANTITY
Project Name: “Repair and Renovation of Existing Building of Madhyanchal Bhawan Extension, Vasant Kunj, Delhi.”
S.NO. DESCRIPTION UNIT QTY. Rate(18%@
Rate Amount Rate Amount
1.00 SUB-HEAD:- 1- EQUIPMENT
1.10 OUTDOOR UNITS (COOLING ONLY) FOR ONLY VRF UNITS
Supply, Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable
Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having 100% hermetically
sealed inverter type Scroll Compressor(s) with and minimum two compressors along with two Condensing fan,
above 14/18 HP modules, microprocessor based Controller, Side / top discharge type condensing unit(s),
with R-410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required.
The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient
temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power
supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The EER at
100% load with AHRI conditions shall not be less than 3.5 and Including OEM supplied Piping connection Kit
etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/
Supply of QWIK FOOT supports system consisting of a G I Steel frame modular/multiples along with adjustable
legs and UV Stabilised Nylon Rubber Crump- SBR recycled with feet assemblies 205/305 standrd Base. . The
frame dimensions should be designed to take the weight with minimal deflection, manufactured from hot dip GI
Carbon Steel. Rubber Crump in the base shall be resin bonded Polyurethane Polymer. Welding standard to be
as per BS EN ISO 1461-2009 for Hot Dipped GI Assembly. The feet shall be 200/305/mm square made from
Nylon 6 B601L 30% glass fibre filled Underneath Rubber for vibrations absorption.The leg assembly should be
adjustable between 210 to max.350 mm for max loading per foot assemble to 500 kg per foot frame &
accommodate unevenness of the terrace floor levels.
LOWER GROUND FLOOR
UPPER GROUND FLOOR
1.20 INDOOR UNIT-DUCTABLE TYPE
Digitally signed by ARTI
DESCRIPTION installation, testing and commissioning of following minimum capacity and external static UNIT QTY.
pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic
media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor,
coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet,
vibration isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase
AC supply 230 V ± 10%, 50 Hz complete as required. Air Decontamination Chamber in the supply air/
plenum comprising of nanoX coating plasmOX having EPA approved metallic compound of five metals targeted
on Alumninum matrix cell duly enclosed by a poly quartz casing tube with the capability to produce ionized
Hydroxyl oxidizers having Required wattage for different CFM's. The Equipment shall a microbiological testing
report against Bacteriophage (MS-2 FDA) surrogate SARS Cov-2 with a minimum efficiency of 99 percent along
with a Virology report from ICMR approved lab with an minimum efficiency of 99 percent against SARS COV2
within 45 minutes. refer details specification for Air Decontamination System for compliance with the following
certification CE, ROHS, ISO, FDA, Green Pro, CCMB, FICCI, TUV & Human Epithelial test By IIT Guwahati).
The unit shall have automatic force shut down valve in case of fire on receiveing signal from BMS
System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C
WB temperature. All as per pre approved by Engineer in charge. For additional technical parameters of
products/ work , refer Annexure "A" attached with this BSR .
LOWER GROUND FLOOR
4.11 Ductable unit : 2.0 TR HIGH STATIC No. 1 38,913 41,376 41376
4.19 Ductable unit : 8.0 TR HIGH STATIC No. 2 89,590 95,261 190522
UPPER GROUND FLOOR 0 0
4.11 Ductable unit : 2.0 TR HIGH STATIC No. 1 38,913 41,376 41376
4.19 Ductable unit : 8.0 TR HIGH STATIC No. 2 89,590 95,261 190522
FIRST FLOOR 0 0
4.90 Ductable unit : 1.6 TR HIGH STATIC No. 20 35,259 37,491 749818
4.11 Ductable unit : 2.0 TR HIGH STATIC No. 8 38,913 41,376 331010
SECOND FLOOR 0 0
4.90 Ductable unit : 1.6 TR HIGH STATIC No. 21 35,259 37,491 787309
4.11 Ductable unit : 2.0 TR HIGH STATIC No. 5 38,913 41,376 206881
4.19 Ductable unit : 8.0 TR HIGH STATIC No. 2 89,590 95,261 190522
THIRD FLOOR 0 0
4.90 Ductable unit : 1.6 TR HIGH STATIC No. 14 35,259 37,491 524873
4.11 Ductable unit : 2.0 TR HIGH STATIC No. 7 38,913 41,376 289633
1.30 CEILING SUSPENDED DX AHU
Digitally signed by ARTI
DESCRIPTIONinstallation, testing and commissioning of Factory Fabricated Ceiling Hung Type Double Skinned Air UNIT QTY.
Cooled VRF Based Air- Handling Unit fabricated out of extruded aluminium section with 0.6 mm pre-plasticized /
pre-coated Galvanised steel sheet outside & 0.6 mm plain Galvanised steel sheet blower section with AMCA
certified Backward fan with VCD (Suitable static pressure as required , minimum 2 bend GSS/ PVC eliminators )
and blower motor TEFC type with IE-3 Class rating suitable for operation on 415 volts ± 10% , 50 Hz ± 5% AC
supply, 4 Row cooling with UV Cell, coil made of Aluminium finned Copper tube with coil section, filter section
with prefilter, pre filter should be washable synthetic type efficiency of filter should be as per ISO-16890,with
Chemical, Biological and Radiological (CBR) filtration with dia-electric media with efficency not less than <90 %
of PM .1 micron alongwith <95 % of gases contamination removal with 350 mm depth (CBR- Certification IACS
for filteration efficiencport against Bacteriophage (MS-2 FDA) surrogate SARS Cov-2 with a minimum efficiency
of 99 percent along with a Virology report from ICMR approved lab with an minimum efficiency of 99 percent
against SARS COV2 within 45 minutes. refer details specification for Air Decontamination System for compliance
with the following certification CE, ROHS, ISO, FDA, Green Pro, CCMB, FICCI, TUV & Human Epithelial test By
IIT Guwahati). The unit shall have automatic force shut down valve in case of fire on receiveing signal
from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19
Degree C WB temperature. All as per pre approved by Engineer in charge. For additional technical parameters
of products/ work , refer Annexure "A" attached with this BSR .
inculding Air Purification systems in the specified areas where AHU/FCU/Ductable units etc are installed, so as
to improve indoor air quality by using, Self-cleaning Needlepoint Ionizer made of Carbon brush emitters with LED
display The Needlepoint brushes shall be designed to properly release equal amount of positive and negative
ions in the supply air,>400Million ions/cc without any obstruction. The units to be suitable for capacities up to
6000 CFM, with universal voltage input 24V to 240V AC/DC, ionizer indicator LED, set of dry contacts which will
indicate ionizer functionality. The unit shall have capability to be switched on 24/7 and shall have weathertight
conduit of minimum 6ft length.System should kill microorganisms and pathogens and backed with Independent
lab test reports on the real virus and not surrogate. The system also should reduce odors, TVOC’s and reduce
particle/particulate matter/PM2.5/PM10. The products should be UL 2998 listed. The systemshould be fitted with
Air Quality monitor to m etc. as required. All as per pre approved by Engineer in charge. For additional technical
The AHU panels shall be insulated with 25 mm thick & 43±2 Kg/m³ density PU foam.The motor & blower
assembly shall be mounted on Aluminium extruded section only. The complete AHU shall conform to standard
specication. AHU Kit should be under the scope of VRF Manufacturer, however the AHU manufacturer should
maintain the provision for the same during factory fabrication.The face velocity across cooling coil shall be limited
to 152 MPM maxm. The capacity of Air-handlers shall be as follows:
Note : Fins and copper tubes alongwith copper tubing / piping with all joints and U-Bends exposed to coastal
areas corrosive atmosphere / aggressive ambient, shall be painted with special corrosion prevention coating at
Cost should be inclusive the Indoor Unit,Outdoor Unit(Suitable Nearest Capacity As given Below), Local
Electrical Control Panel (Starter Panel) with cabling from Panel to TFA Outdoor Units etc. as required.
Refrigerant should be HFC-134a / HFC-410a
All Fan Motor HP shall be as per Final Selection during construction
Note: all hanging support GRIPPLE / HIRA WALRAVEN guide line (SMACNA)
LOWER GROUND FLOOR
Digitally signed by ARTI
S.NO. UPPER GROUND FLOOR
DESCRIPTION UNIT QTY.
1.40 KIT FOR AHUs
Supply, Installation, Testing and Commissioning of VRV Kits for AHUs having all controllers & Electonic
Expansion Valve (EEV) and temperature set arrangment. It Shall have cut off arrangement after a particular set
value of Supply air Temperature. Price should include all control cabling etc. and all necessary arrangements
whether mentioned or not to make the system working.
1.50 CENTRALISED CONTROLLER
Supply, Installation, Testing and Commissioning of main Intelligent Touch Manager with plus adapter as per
specifications to hook up indoor units as mentioned above. Controller shall however, be suitable for minimum
64 groups of indoor units.Centralised controller shall act as master controller for controlling of cooling mode of
outdoor units and their associated indoor units. Controller shall be suitable of Remote Access with computer and
shall have web access. Controller shall be suitable to autosequence the outdoor as well as indoor units catering
to 24x7 operated areas as required/mentioned under sub head "System Design" of tender document. Controller No 1 1,10,000 110000
shall be suitable to configured the inside temperature as per temperature set point on controller. Controller shall
have time schedulling arrangement for Indoor Units as well as Outdoor Units. Controller shall be BMS
Compatible & suitable for BMS integration.
Quoted price shall be inclusive of all necessary cabling as required from ODU & IDUs to controller.
1.60 UVGI SYSTEM (CEILING MOUNTED)
Supply of UV-C Upper Air Disinfection system with option of Ceiling (surface) mounted and total power
consumption of maximum 36W with UV lamp, which shall emit UV-C between the range of 250-254 nm. The
system should have AL Extrusion Housing for Light Weight, Solid Construction – Built To Last, no corrosion,
Perfectly Molded Polished AL Reflector For Highest Efficiency. The lamellae should be non reflective with black
coating and aluminum back plate. The system shall be able to scatter the radiation in 360 degrees. System Outer
dimensions (lxbxh) should not be more than 550X550X120 mm and weight not more than 10 kgs. Manufacturer Nos. 87 15,000 1305000
must provide in vitro test report to mentioning the efficacy of product with a 99.99% reduction of collectable
active pathogen in the air within 10 minutes of exposure .The avg value of irradiance at the center of vertical 1 m
below the disinfection shall be >=7microwatt/cm2, Leakage shall be <0.2 microwatt/cm2. lifetime: 9000h - 90%
UV-C @ end of life. Mechanical impact protectionroller.ainst Bacteriophage (MS-2 FDA) surrogate SARS Cov-2
Digitally signed by ARTI
S.NO. DESCRIPTION UNIT QTY.
2.00 SUB-HEAD:- 3 PIPING WITH INSULATION
2.10 COPPER REFRIGERANT PIPING
Supply, installation, testing and comissioning of interconnecting copper refrigerant piping of DHE Grade
C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For
Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on
Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high
water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as
per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm
threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for
vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as
required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of
products/ work.
Pipe Size Thickness of CSE
(O.D.) Insulation
5.12 41.1 mm O.D., wall thinkness ≥ 1.4mm (insulation – 19 mm thick) RM 50 1,309 1,392 69593
5.11 38 mm O.D., wall thinkness ≥ 1.4mm (insulation – 19 mm thick) RM 50 1,265 1,345 67254
5.10 34.9 mm O.D., wall thinkness ≥ 1.4mm (insulation – 19 mm thick) RM 85 1,230 1,308 111168
5.80 28.6 mm O.D., wall thinkness ≥ 1.2mm (insulation – 19 mm thick) RM 115 1,108 1,178 135486
5.70 25 mm O.D., wall thinkness ≥ 1.2mm (insulation – 19 mm thick) RM 20 1,022 1,087 21734
5.60 22.2 mm O.D., wall thinkness ≥ 1.0mm (insulation – 19 mm thick) RM 100 865 920 91975
5.50 19.1 mm O.D., wall thinkness ≥ 1.0mm (insulation – 13 mm thick) RM 200 707 752 150351
5.40 15.9 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) RM 250 588 625 156305
5.30 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) RM 180 466 495 89190
5.20 9.5 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) RM 235 331 352 82709
5.10 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) RM 225 245 261 58614
Supply, Installation,Testing & Commissioning of following imported copper fittings to be provided in
refrigerant pipe line.
2.2.1 Refnet Joints (Y- Joints) No 90 2,500 225000
2.2.2 Refnet Headers No 6 1,500 9000
2.30 CONDENSATE DRAIN PIPING -cPVC
Digitally signed by ARTI
S.NO. Providing
DESCRIPTION& Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & UNIT QTY.
10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in
wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including
leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge. For
additional technical parameters of products/ work.
3.00 SUB HEAD:- 4 DUCTING & GRILLES
3.10 GSS DUCT (FACTORY FABRICATED)
Supply, fabrication, installation, testing and commissioning of GSS sheet metal ducting for supply & return air
with all the accessories and hanging arrangement. It shall include bends, elbow, tees, spliter, fittings, gaskets
and all accessories for complete installation of ducting . Refer tender specification for detail description
3.20 GSS DUCT (SITE FABRICATED)
Supply, fabrication, installation, testing and commissioning of G.S.S. sheet metal ducting for supply & return air
with all the accessories and hanging arrangement.It shall include bends,elbow,tees,spliter,fittings,gaskets and
all accessories for complete installation of ducting.Refer tender specification for detail description
3.30 VOLUME CONTROL DAMPER
Supplying, installing, testing & commissioning of GI volume control damper with minimum 1.6 mm flange and
1.8 mm blade thickness within ducts to be provided with suitable links, levers and quadrants for manual control Sqm 5 6,046 30230
of volume of air flow and for proper balancing of the air distribution system as per schedules & drawings.
3.40 SUPPLY AIR GRILL
Supply, installation, testing,balancing and fixing of Powder coated aluminium extruded grill with aluminium
construction collar damper for supply air as per specification & the sizes will be as per schedules and Sqm 17 8,105 134498
drawing.Refer technical specification for detail description
Digitally signed by ARTI
S.NO. DESCRIPTION UNIT QTY.
3.50 RETURN AIR GRILL
Supply, installation, testing ,balancing and fixing of Powder coated aluminium extruded grill for return air
as per specification & the sizes will be as per schedules and drawing.Refer technical specification for detail Sqm 16 4,910 78560
3.60 SUPPLY AIR DIFFUSER
Supply, installation, testing,balancing and fixing of Powder coated aluminium extruded grill with collar
damper for supply air as per specification & the sizes will be as per schedules and drawing.Refer technical Sqm 36 9,310 339182
specification for detail description
3.70 RETURN AIR DIFFUSER
Supply, installation, testing ,balancing and fixing of Powder coated aluminium extruded grill for return air
as per specification & the sizes will be as per schedules and drawing.Refer technical specification for detail Sqm 39 6,121 235671
3.80 EXHAUST AIR GRILL
Supplying, Installing, testing and commissioning of powder coated extruded aluminium exhaust air grille with
min.60 % free area, with metallic frame work & fixing accessories, to be fixed on external wall to exhaust air from
basement area to ambient , it shall be suitable for exhausting required air in CFM . Louvers need to be suitable Sqm 5 6500 32500
in order avoid rain water entry in to basement @ 15 degree deflection with bird screen complete as per
specification approved drawings and schedules.
3.90 FRESH AIR GRILL
Supplying, installing, testing and commissioning of GI construction fresh air louvers with min. 60 % free area, bird
screen and painted in baked enamel shade as per clients or architect approval with metallic frame work Sqm 5 8000 40000
complete as per specification approved drawings and schedules.
3.10 FRESH/EXHAUST AIR LOUVER
Supplying, installing, testing and commissioning of GI construction fresh/exhaust air louvers with min. 60 % free
area, bird screen and painted in baked enamel shade as per clients or architect approval with metallic frame Sqm 5 14500 72500
work complete as per specification approved drawings and schedules.
3.11 FIRE DAMPER
Supplying, Fixing,testing and commissioning of fire damper in supply air duct/main branch and return air path as
and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to
close the damper in the event of power failure automatically and open the same in case of power being restored.
The spring return action shall be inbuilt mechanism and not externally mounted. the damper shall also be closed
in the event of fire signal complete as required adn as per specifications.
3.11.1 Fire damper Sqm 5 10659 53295
TOTAL 19,22,606
4.00 SUB HEAD:- 5 INSULATION
4.10 DUCT ACOUSTIC LINING
Digitally signed by ARTI
S.NO. Supply and fixing of acoustic lining of ducts with chemically cross link Oxide accetate foam open cell structure
DESCRIPTION UNIT QTY.
Acoustic Insulation with density 30 Kg / Sqm, UV protected and Class O Fire propperty Water Vapour absorption
0.002 gm / Sqcm, including cost of adhesive etc. complete in all respect. All as per pre approved by Engineer in
charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work.
4.20 DUCT INSULATION
Supply & fixing of external thermal closed-cell Nitrile rubber Insulation material FM/UL approved with high water
vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per
BS 476 Part 6 in form of sheet on duct including cost of adhesive (CPRX Compound) complete as required. All
as per pre approved by Engineer in charge.
4.2.1 19 mm on Supply/Return duct Sqmt 650 650.00 422500
4.2.2 25 mm on Supply/Return duct Sqmt 150 910.00 136500
4.30 DOUBLE LAYER CANVAS CONNECTION
P & F of Fire retardent flexible canvass connection made of fibreglass weave having silver grey silicon rubber
coating, of height 200 mm with sufficient fold to avoid transmission of vibration with GI frame ,Gasket Nut Bolts
for air cooling Plants/AHU/FCU etc as required. All as per pre approved by Engineer in charge. For additional
technical parameters of products/ work.
TOTAL 7,84,000
Digitally signed by ARTI
BOQ - Madhyanchal - Hortriculture.
Project Name: “Repair and Renovation of Existing Building of Madhyanchal Bhawan Extension, Vasant Kunj, Delhi.”
HORTICULTURE & LANDSCAPING
DSR Rate Rate Amount Amount
S.No. Description of Work Unit Qty. Rates incl GST
2020 (DSR-2020) (NS) DSR NS
2.0 HORTICULTURE & LANDSCAPING
Trenching in ordinary soil up to a depth of 60 cm
including removal and stacking of serviceable materials
and then disposing of surplus soil, by spreading and
neatly leveling within a lead of 50 m and making up the
trenched area to proper levels by filling with earth or earth
mixed with sludge or/and manure before and after flooding
trench with water (excluding cost of imported earth, sludge
Supplying and stacking of good earth at site including
2 2.2 royalty and carriage up to 5 km (earth measured in stacks Cum 150.00 515.60 548.24 82235.62 0.00
will be reduced by 20% for payment).
3 2.7 Fine dressing of the ground Sqm 266.73 3.70 4.37 1164.54 0.00
Spreading of sludge, dump manure and / or good earth in
required thickness as per direction of Officer-in-charge
(Cost of sludge, dump manure and / or good earth to be
paid separately).
Grassing with selection No. 1 grass including watering and
maintenance of the lawn for 60 days or more till the grass
5 2.1 forms a thick lawn, free from weeds and fit for mowing
including supplying good earth, if needed (the grass and
earth shall be paid for separately)
2.10.1 In rows 5 cm apart in both directions Sqm 300.00 17.70 18.82 5646.12 0.00
HORTICULTURE & LANDSCAPING - SUBHEAD TOTAL ₹ 1,09,852.34 ₹-
Digitally signed by ARTI
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT addl work Mandhyanchal.pdf
Tender Document
MPB LIST OF MAKES.pdf
Tender Document
technical spec.pdf
Tender Document
Milestone Renovation MPB.pdf
Tender Document
Drawings.pdf
Tender Document
GCC with 11 amendment.pdf
Tender Document
SCC MPB renovation.pdf
Tender Document
renovationBOQMPB280125.pdf
Tender Document
corrigendum-3522-Corrigendum03pricebid21.pdf
pdf • 0.27 MB
corrigendum-3439-Corrigendum02dateextension.pdf
pdf • 0.28 MB
corrigendum-3393-corrigendum01.pdf
pdf • 0.11 MB
addendum-d881c81c3af5-addendum01.pdf
pdf • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .