Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 CrAccepted-AOC | ₹4.3 Cr Quoted ₹4.4 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹4.7 Cr+₹36.8 L (8.40%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | ₹4.7 Cr+₹36.8 L (8.40%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹4.9 Cr+₹48.6 L (11.1%)Rejected-Finance C 101 ADG P CHENNAI | ₹4.9 Cr+₹48.6 L (11.1%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹5.1 Cr+₹77.1 L (17.6%)Rejected-Finance | ₹5.1 Cr+₹77.1 L (17.6%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹5.6 Cr+₹1.2 Cr (28.0%)Rejected-Finance D 3 7TH BLOCK JAIN GREEN ACRES DHARGA ROAD ZAMIN PALLAVARAM CHENNAI 600043 | CHENNAI | CHENNAI | TAMIL NADU | 600043 | ₹5.6 Cr+₹1.2 Cr (28.0%) | L5 | Rejected-Finance Being L5 |
Tender Value
Refer Docs
EMD Value
₹5.2 L
Closing Date
26 Aug 2021, 6:00 pmClosed
Chief Engineer
CE FY HYDERABAD SECUNDERABAD
CONSTRUCTION OF 12 NOS TYPE IV MD ACCN PHASE-I AT CORDITE FACTORY ARUVANKADU
2021_MES_451210_1
870096/AVD/E8
Open Tender
Civil Works
Lump-sum
365 days
Aruvankadu
As per NIT and Tender Document
7 documents required · 7 mandatory
₹2,000
Garrison Engineer (I) (P) Fy Avadi
₹5.2 L
Yes
14 Oct 2021
14 Jun 2021
1 Sept 2021
14 Jun 2021
26 Aug 2021
12 Aug 2021
14 Jun 2021 - 30 Jun 2021
Amount
Lump sum price worked out by the Contractor for “BUILDING AND STRUCTURES” as listed in Schedule ‘A’ Part-I.
Lump sum price worked out by the Contractor for “DEMOLITION/DISMANTLING ” as listed in Schedule ‘A’ Part-II.
Lump sum price worked out by the Contractor for “SITE CLEARANCE AND AREA DEVELOPMENT” as listed in Schedule ‘A’ Part-III.
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A’ Part-IV.
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-V.
Lump sum price worked out by the Contractor for “RETAINING WALL” as listed in Schedule ‘A’ Part-VI.
Lump sum price worked out by the Contractor for “ROAD/PATH AND CULVERT” as listed in Schedule ‘A’ Part-VII.
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part-VIII.
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY ” as listed in Schedule ‘A’ Part-IX.
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part-X.
Lump sum price worked out by the Contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part-XI.
Lump sum price worked out by the Contractor for “SECURITY AND COMPOUND WALL” as listed in Schedule ‘A’ Part-XII.
DEMOLITION (Sch 'A' Part II (A))
Taking down old and unserviceable sub main wiring any size/type/core included earth wire complete with batten/conduit etc complete all as specified and directed.
Taking down old and unserviceable distribution board and any type/way/capacity including fuses, MCB,s insulaltor complete all as specified and directed.
INTERNAL ELECTRIC SUPPLY (Sch 'A' Part IV (A))
Supply and fixing energy efficient, wall mounted LED batten type fitting not less than 22W, 230 volt, provided with extruded aluminium housing for efficient heat dissipation with polycarbonate diffuser and all accessories alongwith integrated electronic driver including connecting up with ceiling rose using twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply & hanging ceiling fan, 1200 mm sweep, 5 star rated with baldes, down rod and all accessories, 230 volt complete all as specified and directed.
Supply and fixing security lighting luminaire for use with LED lamps of capacity not less than 40 watts, 230 volts with high quality lenses & reflector, high grade aluminium pressure Die-cast housing with toughened glass cover, IP_65 class of protection complete with control gear and all accessories fixed with 25 mm bore light grade GI pipe bracket 1.2 mtr long bent to shape, fixed on wall with MS flat clamps, nuts & bolts as required complete all as specified and directed. Cat No BRP 409 LED040CWHOMRFGS1PSGR of Philips or equivalent inWipro/C&S
Supply and fixing exhaust fan, 230 volt, 50 Hz, single pole, 300 mm sweep, 1400RPM with louvers and all accessories including making necessary opening in the wall, fixing on wall using necessary nuts, bolts and washers complete all as specified and directed.
S&F PVC insulated overall PVC sheathed, twin core, 1mm, white cable with copper conductor suitable for telephone drawn through conduit complete all as specified and directed.
S&F PVC insulated overall PVC sheathed, twin core cable with copper conductor suitable for audio video cable for TV. Antenna, satellite, DVR and amplifiers drawn through conduit complete all as specified and directed. Notefor item No 14.05 & 14.06- PVC conduit and conduit accessories measured and paid under approximate items.
M&L for modular type TV Co-Axial socket complete all as specified and directed.
M&L for modular type Telephone Co-Axial socket complete all as specified and directed.
S&F sheet metal box of size 75 x 75mm including fixing of telephone socket and TV socket with hylam sheet complete all as specified and directed.
Supply and fix AC three phase static energy meter of accuracy class 1.0, 3 x 240 V, 50 Hz with bracket LCD display of rating 10-60A complete all as specified and directed.
EXTERNAL WATER SUPPLY (Sch 'A' PART-VIII (A))
Excavating/cutting the hard standing/path/road etc in trenches not exceeding 0.45 mtrs wide and not exceeding 0.60 mtrs in depth for laying the GI protection pipes any size and retruning filling of excavated soils after layingt of GI protection pipe upto a depth of 0.30 mtrs and removing thesurplus soil to a distance of not exceeding 50 mtrs complete all as specified and directed. Note : PCC for make good of the disturbed surface upto 30cm depth from ground level will be measured and paid under respective items.
M&L for labour for construction of brick masonry valve pit chamber of inner dimension not less than 600 x 600 x 600 mm and suitable for sluice valve of size 80mm bore with PCC 1:4:8 type D2 for foundation, brick work in CM 1:6, rendering 15mm thick in CM 1:4 mixed with water proofing compound, coping in pcc 1:2:4 type B1 including necessary earth work fame work and provision of MS sheet cover of size 3.0 mm on 25x25x6mm anlge iron frame with locking arrangement including painting of MS sheet and angle with two coat of synthetic enamel paint over a coat or red oxide primer etc complete all as specified and directed.
EXTERNAL ELECTRIFICATION (Sch 'A' PART-IX (A))
Supply and fix MCCB enclosure suitable for TPN MCCB or rating 160 Amps, 415 V AC, 50 Hz to be fixed on wall in existing sub station of the user to fix MCCB for initial tapping with necessary grouting bolt 04 Nos complete all as specified and directed. Note: MCCB will be measured and paid under respective item.
Supply, install , testing and commissioning of self supporting totally enclosed double door at front, LT feeder piller compartmentalised design, dust and varmin proof of size 1500 mm (Height) x 1000 mm (length) x 450mm (width) suitable for 440 volt 3 phase 4 wire system made out of 3.15mm thick CRCA sheet and built upon rigid frame work having front and rear hinged doors with neoprene rubber gasket including danger plate, earthing strip point and ventilation louvers at the rear side bottom detachable gland plate complete with suitable size of zinc/chromium plated and nuts, bolts and washers etc. The panel shall be synthetic enamelled painted and the control circuit diagram shall be with colour code solid conductor copper 1.5 sqmm cable for easy identification including incomming/outgoing cable holes at the bottom. The panel shall be embedded with 75 x 75 x 6 mm MS angle iron frame 50 cm above the normal ground level complete with pcc foundation (1:2:4) type B2 complete all as specified and directed by Engineer-in-Charge and comprising of the following :- BUS BAR :- Electrolytic grade high conductivity TP & N solid copper bus bars, rated 800 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - 04 Nos. INDICATING DEVICES : LED indicating lamps for main supply indicating R', Y', B' - set of 3. (Contd...16.02)
Note: Since it is a outdoor panel, hence no measuring devices i.e. ammeter& voltmeter have been considered as per policy. CONTROLS (i) MCCB 4 pole, 415 volts, adjustable type, 160 Amps with breaking capacity 36 KA-01 No (Incoming). (ii) MCCB 63 Amps, 4 pole, 25 KA-04 Nos (03 Nos buildings+01 No spare). (iii) MCB SPN 40 Amps for street lgiht - 01 No. (iv) Street light timer with 2 pole contractor 20 Amps -01 Set
Earthing complete with galvanised steel earth plate electrode 600x 600 x 6mm thick, buried directly in ground with earth pit not less than 2.25 metres deep below ground level with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI strip 25 x 6 mm by means of bolts, nuts, and washers of galvanised iron or steel all as shwoin in electrical plate No 3 SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and as directed. Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, RCC 1:2;4 type B-1 cover 40mm thick reinforced with 8 mm dia CTD bars @ 75mm c/c both ways, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 40mm dia, earthing lead upto 7.5m complete all as specified in prembles of SSR Part-II and shown in electrical plate No 3 of SSR Part-I
Supply and fix LED street light 35 watt complete all as per Cat No ENDURACITYLITEPLATPLUSSL35WLED 757SASYB OPC of make Havells or equivalent makes of Bajaj/HPL/Wipro
Supply and fix stree light bracket made out of 40mm bore galvanised iron, light grade tubing (approx 1 mtr in length) including necessary two Nos suitable size of clamps with nuts, bolts and washers etc and two coat of sytnethic enameled paint over a coat of red oxide primer complete all as speciified and directed.
S&F cable junction box 167 x 125 x 82mm in size, made out of thermoplastic sheet having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (cat loge No 1555, 17.06 of make : Hensel complete all as per Cat No K9100 of make : HENSEL or equivalent model lin SPELSBERG/SINTEX, fixed on poles with flat aluminium clamps of size 20x3 mm, nuts, bolts, washers etc cable junction box complete all as specified and directed
Supply and connect PVC insulate, PVC sheathed three core twiested flexible copper conductor cable of size 1.5 sqmm from junction box to street light fitting including 15mm dia light grade GI pipe for cable protection and minimum 02 sets iron clamps, nuts, bolts and washers etc for fixing the GI pipe complete all as specified and directed.
Excavating/cutting in the hard standing/path/road etc in trenches not exceeding 0.45 mtrs wide and not exceeding 0.60 mtrs in depth for laying the GI protection pipes any size and returning filling of excavated soils after laying of GI protection pipe upto a depth of 0.30 mtrs and removing the surplus soil to a distance of not exceeding 50 mtrs complete all as specified and directed.
Sree Constructions
ACE PROMOTERS
K S MUTHU CONSTRUCTTIONS
lakshmibuilders
M SUNDARARAJAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .