Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC NO 17 GANDHI STREET ARUMPARTHAPURAM PUDUCHERRY 605 110 | CUDDALORE | TAMIL NADU | 605110 | ₹26.1 L | L1 | Accepted-AOC lowest tenderer |
Tender Value
₹25.1 L
EMD Value
₹50,110
Closing Date
21 Mar 2024, 4:00 pmClosed
The Executive Engineer, ID., PWD., Puducherry.
The Executive Engineer, Irrigation Division, PWD., No.3, Eveche Street, Puducherry.
Construction of 2 Nos. of RCC Slab culverts across the Oulgaret Pallavoikkal at Main Road and 3rd Cross Street of Thirumalai Thayar Nagar in Oulgaret Revenue Village, Puducherry-(IV Call).
2024_PWDC2_15604_1
TN.27/PW/IRRN/2023-2024-4-CALL
Open Tender
Civil Works
Item Rate
120 days
Puducherry
Please Refer Tender Documents
3 documents required · 3 mandatory
₹525
₹50,110
6 Dec 2024
7 Mar 2024
22 Mar 2024
7 Mar 2024
21 Mar 2024
7 Mar 2024
Amount
Earth work in excavation for foundation of structures as per drawings and technical specifications, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material - Oridnary Soil - Mechanical Means - Depth upto 3 metres including the cost of labour hire charge of hydraulic excavator and overhead charges.
Supply of Quarry rubbish including stacking to department gauge for premeasurement and spreading required thickness
Cement concrete 1:4:8 mix with stone aggregate 40mm nominal size in foundation upto a depth of 1.5 metres below ground level and upto height of 1.5 above ground/bed level.
Centring and shuttering including strutting , propping etc. and removal of form work for - foundations, footings, bases for columns
Centring and shuttering including strutting , propping etc. and removal of form work for - retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns,piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping,bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. upto floor five level, excluding the cost of centering ,shuttering and finishing - 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Reinforced cement concrete m-20 mix with stone aggregate 20mm nominal size mechanically mixed and vibrated for reinforced concrete work in slab excluding steel reinforcement, but including centering and shuttering, laid in position.
Steel reinforcement for R.C.C. works including bending, binding and placing in position - Thermo Mechanical Treated Bars (TISCON / VIZAG / IISCO / SAIL/JSW) Fe - 415 or more
Plain cement concrete m-15 mix with stone aggregates 20mm nominal size mechanically mixed and vibrated in foundation upto a depth of 1.50 metres below ground level and/or 1.50 metres above ground/bed level.
Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes - 110 mm diameter
12mm cement plaster finished with a floating coat of neat cement of mix - 1:3 (1 cement :3 fine sand)
Extra providing and laying Ready mix concrete - in all grade of concrete in PCC works / RCC works
Applying one coat of water thinnable cement primer of approved brand and manufacturer on wall surface - water thinnable cement primer
Wall painting with plastic emulsion paint - Royal of approved brand and manufacture to give an even shade - two or more coats on new work
Making of bund wall with HDPE cement bags filled with stone dust/quary rubbish for discharge regulation, breach closing/ diversion arrangement. The rate includes head load the cost of empty HDPE bags, cost of stone dust, labour charges for filling the bags and placing in position of its purpose working in or under foul/slush condition ,in or under water and / or liquid mud, including pumping out water as required all as directed by the Engineer-in-charge
Steel work welded in built up sections / framed work , including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required - in gratings, frames, guard bar, ladder, railings, brackets,gates and similar works
Providing and laying filter media using HBG metal of 12.5 mm size to a required thickness
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .