Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance PLOT NO F28 COMPLETE COOLING SOLUTIONS LLP PHASE 8 INDUSTRIAL AREA SAS NAGAR MOHALI PUNJAB 160055 | S A S NAGAR | PUNJAB | 160055 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
12 Jul 2023, 3:00 pmClosed
Deputy Registrar
Store and Purchase M Visvesvaraya Block Indian Institute of Technology Ropar Rupnagar 140001
Tender for Supply Installation Testing and Commissioning of VRV VRF Air Conditioning System
2023_IITRP_758712_1
1809-23
Open Limited
Laboratory and scientific equipment
Buy
30 days
IIT Ropar
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹40,000
Yes
10 Jul 2024
21 Jun 2023
12 Jul 2023
21 Jun 2023
12 Jul 2023
21 Jun 2023
21 Jun 2023 - 5 Jul 2023
Variable Refrigerant Volume System Outdoor Unit All outdoor shall have approximately following as per OEM standards rated capacities at ARI conditions and, with the criteria of delivering 95% capacity at 43 °C being most likey temperature to occur during summers. (All Unit shall confirm the detailed specification of tender document and providing power/ control cabling/earthing of indoor unit complete with supply and installation of all material in all respect as per specifications and any other items required to make the system complete as required) MAKE : MITSUBISHI, FIJITSU GENERAL, DAIKIN
14 HP Heating and cooling Top Discharge
12 HP Heating and cooling Top Discharge
Indoor Units Supply, Installation, Testing and Commissioning of VRV/VRF Cassette type indoor units with factory fitted electronic expansion valve, multi speed fan motors, dynamically balanced blowers, synthetic washable plasma media filter with hydrophobic coating on cooling coil. Electronic components like PCBs must be essentially enclosed in a metal box compartment being integrated part of indoor unit to ensure enhanced fire protection with auto by pass technology allowing uninterupted operation of indoor units connected to a circuit in event of break down in any indoor connected to same circuit. All indoor units shall have individual fan speed and temperature control mechanism to be operated from corded remote. In addition to all indoor units can also be operated from central remote control. (All Unit shall confirm the detailed specification of tender document and providing power/ control cabling/earthing of indoor unit complete with supplying of all material in all respect as per specifications and any other items required to make the system complete as required) MAKE : MITSUBISHI, FIJITSU GENERAL, DAIKIN
Cassette AC 4.0 TR/ 5.0 HP
Cassette AC 2.6 TR/ 3.2 HP
Cassette AC 2.0 TR/ 2.6 HP
Hi wall Split Units SITC of Inverter Type Split AC with time scheduler 1.9 TR Hi wall type - 1 to 1 Machine
Supply Installation testing and commissioning of Corded remote controls. MAKE : MITSUBISHI, FIJITSU GENERAL, DAIKIN
Supply Installation, Testing and commissioning of fittings (Ref Net) Y-joints etc as per specifications. MAKE : MITSUBISHI, FIJITSU GENERAL, DAIKIN
Supply Installation, Testing and commissioning of fittings Outdoor connecting kit etc as per specifications. MAKE : MITSUBISHI, FIJITSU GENERAL, DAIKIN
Refrigerant Piping for VRV units SITC of Copper tubes 99.90% pure copper and Phosphorous 0.015 to 0.04% confirming to ASTM B280/ JIS H3300:1997/ EN12735-1 or equivalent, manufactured using High Residual Phosphorous De-oxidised Copper Alloy C1220. Tubes shall be horizontally marked with Brand, Standard, Dimensions printed on the Tube with necessary factory test certificates . copper refrigerant pipework 19 mm / 13 mm thick duly insulated with Nitrile insulation between indoor and outdoor units as per specifications
34.9 mm outer dia (insulation 19mm)
28.6 mm outer dia (insulation 19mm)
22.2 mm outer dia (insulation 19mm)
19.1 mm outer dia (insulation 13mm)
15.9 mm outer dia (insulation 13mm)
12.7 mm outer dia (insulation 13mm)
9.5 mm outer dia (insulation 13mm)
6.4 mm outer dia (insulation 13mm)
Supply, Installation, testing and commissioning of UPVC piping complete with fittings, supports as per specifications MAKE : PRINCE, SUPREME, FINOLEX, KISAN
50 mm dia
40 mm dia
32 mm dia
25 mm dia
SITC of Covered Cable Tray
150 MM X 50 mm
100 mm x 50 mm
CONTROL & TRANSMISSION WIRING
Supply, Installation, Testing and Commissioning of control cum transmission wiring of 2 core x 1.5 sq mm copper wire in suitable PVC conduits between indoor & outdoor units to central remote controllers & for connections between indoor unit to remote control
Supply, Installation, Testing and Commissioning of control cum transmission wiring of 3 core x 2.5 sq mm copper wire in suitable PVC conduits From panel to indoor & outdoor units
Supply, Installation, Testing and Commissioning of Electrical wiring of 4 core x 4.0 sq mm copper wire in suitable PVC conduits between Panel to Outdoor units
Optional Items
Optional comprehensive warranty for 1st year after warranty period
Optional comprehensive warranty for 2nd year after warranty period
SMD Solutions
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .