Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC 129 2 CHANDER NAGAR ALAMBAGH LUCKNOW UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | ₹31.0 L Quoted ₹31.6 L | L1 | Accepted-AOC Awarded contract accpatance letter |
| 2 | L2₹32.9 L+₹1.2 L (3.91%)Rejected-Finance | ₹32.9 L+₹1.2 L (3.91%) | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | L3₹32.9 L+₹1.3 L (3.96%)Rejected-Finance GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | ₹32.9 L+₹1.3 L (3.96%) | L3 | Rejected-Finance OTHER THAN L1 |
| 4 | L4₹34.4 L+₹2.8 L (8.77%)Rejected-Finance | ₹34.4 L+₹2.8 L (8.77%) | L4 | Rejected-Finance OTHER THAN L1 |
| 5 | L5₹35.2 L+₹3.6 L (11.4%)Rejected-Finance | ₹35.2 L+₹3.6 L (11.4%) | L5 | Rejected-Finance OTHER THAN L1 |
| Sl No | Description | Qty | Unit | QUALITY CONSTRUCTIONS CO L3 | UJJAWAL ENTERPRISES L2 | OM NAMAH SHIVAY ENTERPRISES L4 | vishal L5 | KAWAL PAL SINGH & CO L1 | GYAN ENTERPRISES L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.5 m wide and not exc 1.5m deep for laying of pipe, cable etc and getting out in soft/loose complete all as specified and directed. | 581 | Cum | 140 ₹81,340 | 135 ₹78,435 | 110 ₹63,910 Lowest | 110 ₹63,910 Lowest | 200 ₹1,16,200 | 160 ₹92,960 |
| 2.00 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed. | 470.58 | Cum | 80 ₹37,646.4 | 50 ₹23,529 Lowest | 75 ₹35,293.5 | 60 ₹28,234.8 | 100 ₹47,058 | 60 ₹28,234.8 |
| 3.00 | Removing surplus excavated material to a distance not exc 50 meter and depositing where directed at level not exc 1.5m above the starting point, complete all as specified and directed. | 110.6 | Cum | 140 ₹15,484 | 40 ₹4,424 Lowest | 100 ₹11,060 | 50 ₹5,530 | 100 ₹11,060 | 60 ₹6,636 |
| 4.00 | Supplying and laying bricks common brunt clay building bricks sub class B bricks laid across the cable width equal to length of brick for cable protection incl removing of old bricks complete all as specified and directed by Engr - in - Charge. | 6.4 | Per 1000 Nos | 5,000 ₹32,000 | 4,150 ₹26,560 | 4,500 ₹28,800 | 6,000 ₹38,400 | 4,000 ₹25,600 Lowest | 5,650 ₹36,160 |
| 5.00 | Supplying, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cable for under ground cable complete all as specified & directed by Engr - in - Charge. (Note:- Punned depth of sand should be measured and paid) | 64.8 | CUM | 500 ₹32,400 | 360 ₹23,328 | 350 ₹22,680 Lowest | 750 ₹48,600 | 700 ₹45,360 | 370 ₹23,976 |
| 6.00 | M&L taking out/down of old U/S GI pipeline for the following size from excavated trenches including removal of fitting all as directed for necessary serviceable GI pipeline complete all as specified and directed by Engr-in-Charge.
(a) 15mm bore | 180 | RM | 20 ₹3,600 | 20 ₹3,600 | 1 ₹180 Lowest | 2 ₹360 | 10 ₹1,800 | 12 ₹2,160 |
| 7.00 | (b) All as per item above No 6 but 20mm bore | 750 | RM | 30 ₹22,500 | 25 ₹18,750 | 1 ₹750 Lowest | 4 ₹3,000 | 10 ₹7,500 | 12 ₹9,000 |
| 8.00 | (c) All as per item above No 6 but 25mm bore | 645 | RM | 40 ₹25,800 | 30 ₹19,350 | 1 ₹645 Lowest | 6 ₹3,870 | 20 ₹12,900 | 12 ₹7,740 |
| 9.00 | (d) All as per item above No 6 but 40mm bore | 455 | RM | 50 ₹22,750 | 40 ₹18,200 | 1 ₹455 Lowest | 8 ₹3,640 | 20 ₹9,100 | 25 ₹11,375 |
| 10.00 | (e) All as per item above No 6 but 50mm bore | 325 | RM | 60 ₹19,500 | 45 ₹14,625 | 1 ₹325 Lowest | 10 ₹3,250 | 20 ₹6,500 | 25 ₹8,125 |
Tender Value
₹35.2 L
EMD Value
₹70,360
Closing Date
17 Feb 2026, 6:00 pmClosed
GE EAST LUCKNOW
GE EAST LUCKNOW PIN 226002
SPECIAL REPAIR OF EXTERNAL WATER SUPPLY AND CONNECTED WORK AT MILITARY STATION BARABANKI UNDER GE EAST LUCKNOW
2026_MES_750047_1
GE/E/LKO/T-64 OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
GE EAST LUCKNOW
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE(EAST) LUCKNOW
₹70,360
Yes
23 Mar 2026
27 Jan 2026
24 Feb 2026
27 Jan 2026
17 Feb 2026
10 Feb 2026
Excavation in trenches not exc 1.5 m wide and not exc 1.5m deep for laying of pipe, cable etc and getting out in soft/loose complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed.
Removing surplus excavated material to a distance not exc 50 meter and depositing where directed at level not exc 1.5m above the starting point, complete all as specified and directed.
Supplying and laying bricks common brunt clay building bricks sub class B bricks laid across the cable width equal to length of brick for cable protection incl removing of old bricks complete all as specified and directed by Engr - in - Charge.
Supplying, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cable for under ground cable complete all as specified & directed by Engr - in - Charge. (Note:- Punned depth of sand should be measured and paid)
M&L taking out/down of old U/S GI pipeline for the following size from excavated trenches including removal of fitting all as directed for necessary serviceable GI pipeline complete all as specified and directed by Engr-in-Charge. (a) 15mm bore
(b) 20mm bore
(c) 25mm bore
(d) 40mm bore
(e) 50mm bore
(f) 80mm bore
(g) 100mm bore
M&L Relaying of GI pipe after removal of scalling , cleaning and flushing etc including supply and fixing of new fittings of following sizes of any grade in trenches and testing complete all as specified and directed .(a) 15mm bore
(b) 20mm bore
(c) 25mm bore
(d) 40mm bore
(e) 50mm bore
(f) 80mm bore
(g) 100mm bore
M&L for Relaying only of GI pipe after removal of scalling , cleaning and flushing etc including supply and fixing of new fittings of following sizes of any grade in floor,walls or in ceiling and testing complete all as specified and directed. (a) 15 mm bore
(b) 20 mm bore
(c) 25 mm bore
Supply & laying only of GI pipe medium grade, with all fittings, laid in trenches or on walls, complete, all as specified and directed .( Note:- Contractor is required to submit PV and MTC &ebay bill of all type of GI pipe before submission of running payment) (a) 15mm bore
(b) 20mm bore
(c) 25mm bore
(d) 40mm bore
(e) 50mm bore
(f) 80mm bore
(g) 100mm bore
Supply & laying of GI pipe medium grade, with all fittings, laid in trenches or on walls for new location or re-routing complete all as specified and directed.
S & F in repair Gun metal gate valve repair with iron wheel head, screwed both ends for iron pipe of the following sizes. (a) 15 mm dia
(b) 20 mm dia
(c) 25 mm dia
(d) 40 mm dia
(e) 50 mm dia
Supply and fixing of compact universal STEQUA 411 AE refill applicator of the following specification: Multi-avity 100 L water treatment station with proportinal dose adjustment options, diaphrgm-free tube based self priming fluid delivery drive unit to prevent air/vapour lock and dry-run problems prime loss-zero, agitator free system to prevent enviremental corrosion fluid relese up to 5 LPH independent of back pressure up to 7 bars, Erosion-enabled system for controlled relese of Chlorine with accurate output reprodcibility intregrated plug & play sytem operating on single phase 230 V 50 Hz power source, complete all as specified and directed.
Supply and laying plastic cylindrical sealed disposable sanitiser refill containing solid chlorine for disinfection of drinking water with arrangement for controlled release of disinfectant in water, suitable for operation trough recommended dosing system. replacement indication: visual & weight variation, water contact orifice design: Sealed when dry, exposed upon immersion. Operation type: Non- contact, non-inhalatory Cylinder dia: 2.5 inches+- 0.5 Inches, cylinder hight: Minimum 10.0 inches +- 0.5 inches complete all as specified and directed,
Supply and laying in replacement Flat submersible cable PVC insulated weather / water proof with flexible copper conductor 1100 V grade of size 10 sqm 3 core laid into the bore well with wall support clips along with the submersible pump set from the starter complete all as specified & directed by EIC.
M&L in repair for construction of valve PIT chamber of size 750mmx750mmx750 mm (internal dimension) with PCC 1:4:8 for foundation 150 mm thick , brick work built with CM 1:6 , PCC 1:3:6 coping 50 mm thick plastering 15 mm thick in CM 1:6 to all internal and exposed surfaces including excavation ,earth work in hard / dense soil , MS sheet cover 4 mm thick and with MS angle iron 50 mm x 50 mm x 6 mm as per existing size with locking arrangement embedded in PCC suitable for 25/40/50 mm gate valves and painting the MS cover with two coats of synthetic enamel paint over one coat of red oxide / metal primer on metallic sheet, hinges etc including taking down / dismantling the old materials and finishing exposed surface brick plaster of wall putty and cement base paint and steel with two coat of synthetic enamel paint over a coat of primer complete all as specified and directed.
S&F in repair sluice valve, cast iron body, ISI marked and iron wheel head, flanged, class PN-1.6, IS: 14846-2000 including jointing material, rubber gasket, nuts, bolts, etc complete of 100 mm bore . including taking down / dismantling the old items complete all as specified and directed.
S&F in repair sluice valve, cast iron body, ISI marked and iron wheel head, flanged, class PN-1.6, IS: 14846-2000 including jointing material, rubber gasket, nuts, bolts, etc complete of 80 mm bore . including taking down / dismantling the old items complete all as specified and directed.
S&F in repair Non return valve of DI flanged end, class-I, ISI marked with rubber packing, nuts & bolts etc complete of 100 mm bore ..ncluding taking down / dismantling the old items complete all as specified and directed.
M&L for draining out water from over head reservoir of 50000 Gln capacity , removing sludge deposited, scales and other impurities from inside the tank thoroughly by scrapping with wire brushes, broom stick to make the surfaces free from sludge deposit and impurities, cleaning & washing the surfaces with bleaching powder solution including rewashing with fresh water and writing letters /figures like “Tank cleaned on________(date) and Due date_____ boldly & prominently with thick synthetic enamel with height & width of letters/figures 15cm & 10cm respectively in prominent places of tank ,white washing inside and out side distemper colourcomplete OH Tank as directed.and also painting the all in comming , out going, over flow CI/DI water main including scarping out the old painting and applying two coats of synthetic enamel paint over a coat of red oxide with proper colour coading and marking complete all as specified and as directed. (Note :- Scafolding work shall be provided by contracter at own arrangement and cost of the same shall be deemed included in quoted unit rate. Photo graphs before cleaning & after cleaning painting shall be made and kept on record.)
M&L for writing letters or figures not exc 30 cm height and not exc 5 cm width each in block Roman, Italian or indian letters including suitable size stops, comma, arrows, brackets, dashes etc on walls, sign boards (black or yellow or as required base) including two coats of oil paint over a coat of white base synthetic enamel paint complete all as specified and directed.(Note:-letters will be measured and paid.cost of comma,stops,arrows,brackets will not be measured and paid and it will be deemed included in quoted unit rate )
S&F in repair PVC/SMC weather proof, hinged door, junction box, size 300mm x 200mm x 100mm with 30A Aluminium bus bar 04 Nos, 240V, Neutral link and 1No MCB SP of 06 Amps, alongwith necessary fixing arrangement such as clamps, nut, bolts, etc including taking down / dismantling the old items complete all as specified and directed.
S&F in replacement street light fitting Pressure die cast aluminium housing maximum system wattage 65 W, with PMMA lenses,External built proper heat shinks and toughtened glass/PC ensuring IP66 & IK>05 protection, LED used shall be SMD type and fixture should have minium efficiency at system level (Not chip level) 100 Lumens/Watt, Life of system should 50000 Hrs all including necessary wire for fitting light to pole and 1.2 mtr long and bracket 40 mm GI Pipe light grade bend to shape with all necessary clamp all as specified and directed by Engr-in- Charge
M&L for writting name in LED lighting system with enclosure size 3 mtr x 0.8 mtr CGI Sheet min 2.0 mm thickness (Water Suply E/M BARABANKI) with minimum size 300 x 50 mm in PVC material IP-66 of complete as per sample complete all as specified & directed.
Taking down the old U/S PCC/RCC poles of any height ,struts including Demolition of cement concrete,GI structure supports, stay assemblies, junction box etc complete all as specified and directed.
Supply, fixing ,erecting in replacement in proper position 9.0 Mtr steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 metres long) complete all as specified and directed by EIC.Note: (i) Excavation ,earth work and PCC shall be measured and paid separately.(ii) Painting will be measured and paid seperately under relevent item.
Supply, laying and testing cable in repair XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core, including taking down / dismantling the old u/s cable complete all as specified and directed.
Supply and laying cable in repair XLPE insulated screened meter PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 sqmm 3.50 Core including complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using 40 mm graded crushed aggregate as in base foundation of pole concrete including providing necessary form work complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 using 40 mm graded aggregate crushed stone as in foundation of pole/stay and filling of mass concrete including providing necessary form work complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in coping of pole including providing necessary form work complete all as specified and directed.
Supply, laying and testing cable in repair XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core, including taking down / dismantling the old u/s cable complete all as specified and directed.
Supply and laying cable in repair XLPE insulated screened meter PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 sqmm 3.50 Core including complete all as specified and directed.
M&L in replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 32 x 6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion”.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
Tender64.pdf
Tender Documents • 1.97 MB
BOQ_840042.xls
BOQ • 1.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .