| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC 13 218 MASJID EXTEN SADAR BAZAR | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹19.0 L+₹1.8 L (10.3%)Rejected-Finance | L2 | Rejected-Finance Not Being L1. | |
| 3 | L3₹19.5 L+₹2.3 L (13.6%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L3 | Rejected-Finance Not Being L1. | |
| 4 | L4₹21.5 L+₹4.4 L (25.4%)Rejected-Finance | L4 | Rejected-Finance Not Being L1. | |
| 5 | L5₹21.7 L+₹4.5 L (26.1%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L5 | Rejected-Finance Not Being L1. |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
18 Jul 2024, 6:00 pmClosed
GE South Delhi Cantt-10
GE South Delhi Cantt-10
REPAIR/REPLACEMENT OF DBs SUBMAIN WIRING, EARTHING, BUILDING SECURITY LIGHTS AND MISC WORKS AT OTM AND MD ACCN AT SHANKAR VIHAR, BANASINGH, YOGENDRA VIHAR, 18 MADRAS AND 5/11 GR UNDER AGE E/M OF GE (SOUTH) DELHI CANTT-10
2024_MES_660586_1
GE/DS-40/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹90,000
28 Sept 2024
19 Jun 2024
25 Jul 2024
19 Jun 2024
18 Jul 2024
4 Jul 2024
Amount
S&F in repairs of sub main wiring using single run PVC FRLS grade insulated unsheathed, multisrand copper conductor cable 2 runs of 06 Sqmm for Phase and neutral and 1 run of 06 Sqmm for earth wire drawn through existing PVC/MS conduit and including replacement of unsv pressed steel terminal boxes of in wall as per suitable/existing dia with fittings like tees, bends junction/terminal boxes etc as per site requirement complete all as specified and as as directed. Note : (a) Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be of green colour. (b) Three runs of main cable and one run of earth cable all together shall be considered as one length. (c) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
S&F in repairs of sub main wiring using single run PVC FRLS grade insulated unsheathed, multisrand copper conductor cable 2 runs of 10 Sqmm for Phase and neutral and 1 run of 10 Sqmm for earth wire drawn through existing PVC/MS conduit and including replacement of unsv pressed steel terminal boxes of in wall as per suitable/existing dia with fittings like tees, bends junction/terminal boxes etc as per site requirement complete all as specified and as as directed. Note : (a) Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be of green colour. (b) Three runs of main cable and one run of earth cable all together shall be considered as one length. (c) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
S&F in repairs MCCB 4 pole 200 Amp 36 KA 415 Volts with breaking capacity 36 KA complete all as specified and as directed.
S&F in repairs MCCB 160 Amps 4 pole 415 volts fixed type with breaking capacity 25 KA 415 Volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as specified and as directed.
S&F in repairs MCCB 125 Amps 4 pole 415 volts fixed type with breaking capacity 16 KA 415 Volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as specified and as directed.
S&F in repairs MCCB 100 Amps 4 pole 415 volts fixed type with breaking capacity 16 KA 415 Volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as specified and as directed.
S&F in repairs MCB TPN 3 pole 63 Amp 415 Volt, 'C' Series 10 KA' as per site requirement complete all as specified and as directed.
S&F in repairs MCB SPN 40 to 63 Amp 240 Volt, 10 KA 'B' all as per site requirement complete all as specified and as directed.
S&F in repairs MCB SPN 32 Amp 240 Volt, 10 KA 'B' all as per site requirement complete all as specified and as directed.
S&F in repairs MCB SP 6 to 32 Amp 240 Volts, 10 KA, 'B' curve all as per site requirement complete all as specified and as directed.
S&F in repairs VTPN DB 8 way double door type with Rubber gas kit for fixing MCCB upto 250 Amps as incomer and MCB as out going with metal door and IP 43 protctions & connecting complete all as specified and as directed.
S&F in repairs of sheet metal enclosures for DBs when MCBs to be used VTPN-4 Way, 415V with Rubber gas kit double door with bus bar as per site requirement complete all as specified and as directed.
S&F in repairs of sheet metal enclosures for DBs when MCBs to be used SPN-16 Way, 240V with Rubber gas kit double door type without busbar as per site requirement complete all as specified and as directed.
S&F in repairs of sheet metal enclosures for DBs when MCBs to be used SPN-8 Way, 240V with Rubber gas kit double door type with busbar as per site requirement complete all as specified and as directed.
S&F in repairs of sheet metal enclosures for DBs when MCBs to be used SPN-12 Way, 240V with Rubber gas kit double door type with busbar as per site requirement complete all as specified and as directed.
S&F in repairs single pole and neutral metal clad sheet metal enclosures with 2 pin and earth plug and socket complete with one no MCB SPN upto 32 Amps as per site requirment of existing type for AC's/Geyser complete all as specified and as directed.
S&F in repairs earthing complete with galvanized steel earth plate electrode 60cmx60cmx6cm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to GI wire 4 mm as earthing lead by means of nut, bolts and check nuts and washers, GI light grade protection pipe 15 mm dia upto 7.5 M, GI watering pipe 20 mm medium grade, RCC cover with funnel, excavation in any type of soil, PCC pit charcoal, salt all as shown in electrical plate No.5 of SSR Part-I, including earth test point upto panel board complete all as specified and as directed.
S&F in repairs earth continuity conductor/main earthing lead fixed to wall on batten, buried in ground, drawn in conduit pipe or fixed, poles or any other indicate situation for loop earthing etc. as required 4 mm dia galvanised iron wire complete all as specified and as directed.
S&F in repairs LED building security light 45 Watts from existing bracket complete all as specified and as directed.
S&F in repairs GI pipe's bracket suitable for fixing of bldg security LED light fitting of 45 Watts including grouting and fixing the same on wall for installation of light fitting with necessary clamps, nut, bolts & washer and painting by synthetic enameled good quality paint in white/grey colour over one coat of red oxide primer until unless smoothness of bracket complete all as specified and as directed. Note:- GI pipe should be 25 mm bore with medium grade and the same to be moulded in 45 degree angle at the 1 Mtr height to fix the building security light fitting.
S&F in repairs LED post top lantern fitting with die cast aluminium spigot, spun aluminium power coated top cover aluminium PDC heat sink opal PC diffuser clear acrylic IP-65 with 45 Watt power including all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete including making a hole in pillar/wall with light grade GI pipe of suitable size for fixing the post top lantern fitting complete all as specified and as directed.
M&L for excavation of existing LT cable of any size and taking it out from the floor/protection pipe and including incomer electrical connection of in 4P MCCB of VTPN with suitable size of thimble complete with retirning filling and make good of excavated surface/floor complete all as specified and as directed.
Supply & laying and testing in repair of cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 2 core complete all as specified and as directed.
Supply & laying and testing in repair of cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and as directed.
Supply & laying and testing in repair of cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and as directed.
Excavating in trenches n. exc 1.5 mm wide and n.exc 1.5 m in depth, for laying under ground cable, and getting out in soft/loose soil complete all as specified and as directed.
Returning and filling including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in hard/dense soil/Soft loose soil complete all as specified and as directed.
Removing excavated material (soil) to a distance n.exc 50 m where directed at a lever not exc 1.5m above the starting point complete all as specified and as directed.
M&L for sand filling under floors or in foundatins includng watering and consolidation/trenches below and around under ground cables for cushioning of calbes etc. complete all as specified and as directed.
Supply and laying Bricks common burnt clay building bricks sub class A designation 75, size 230mmx115mmx75mm complete all as specified and as directed.
Supply and laying High density polyethylene(HDPE) pipes of pressure rating 6kg/sq.cm (IS marked) and laid in trenches/under roads/ in drains/fixed to poles/walls of size 50 mm dia complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or pwer) complete including fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets etc making good disturbed surfaces of walls, floors etc. complete all as specified and as directed.
M&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLSH 1100 volts grade electrical cable suitable concealed PVC/MS conduit and including replacment of unsv pressed steel terminal boxes of required size and factory painted with stove enameled black paint with top cover 3mm thick plastic/laminated sheet of required colour with screwed and cup washer with all accessories including 1.5 Sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sqmm for phase and neutral and 1.5 Sqmm for earthing) complete all as specified and as directed. Note:- The rate is inclusive cutting/chasing and making good distrubed surface with CM 1:3 adn same surface finishes with the adjoining surface of distribed area with ODB/colour wash/white wash completed.
All as per Srl item No.33 above, but one 3 pin socket outlet, 5/6 Amps, independent, with cable 1.5 Sqmm suitable concealed PVC/MS conduit complete all as specified and as directed.
All as per Srl item No.33 above, but 5 Amp socket outlet on same board complete all as specified and as directed.
All as per Srl item No.33 above, but for one socket outlet 15 Amps on independent board with cable 2.5 Sqmm size for phase and neutral and 2.5 Sqmm for earthing with through existing PVC/MS conduit complete all as specified and as directed.
All as per Srl item No.33 above, but for one socket outlet 15 Amps on independent board with cable 4.0 Sqmm size for phase and neutral and 4.0 Sqmm for earthing with through existing PVC/MS conduit complete all as specified and as directed.
All as per Srl item No.33 above, but for one light controlled by 2 Way switch using cable 1.5 Sqmm size for phase and neutral and 1.5 Sqmm for earthing with through existing PVC/MS conduit complete all as specified and as directed.
S&F switch piano flush type 5/6 Amps SP one way complete all as specified and as directed.
S&F switch piano flush type 5/6 Amps SP two way complete all as specified and as directed.
S&F bell push, flush type 5/6 Amps complete all as specified and as directed.
S&F socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose complete all as specified and as directed.
S&F switch piano flush type 15/16 Amps SP one way complete all as specified and as directed.
S&F universal socket outlet 2-in1 (multipurpose) 5 pin 6/16 Amps flush mounted type complete all as specified and as directed.
S&F 0-4 step type electronic regulator for ceiling fan 1200/1400 sweep, 240 V complete all as specified and as directed.
S&F electric bell ding dong any type complete all as specified and as directed.
S&F ceiling rose surface bakelite 65x25 mm two to three terminals complete all as specified and as directed.
S&F lamp holder bakelite insulated body with back plate suitable for batten fitting complete all as specified and as directed.
S&F in repairs wall mounted LED integrated batten T-5 20 Watt - 4ft white 6500K, indoor decorative PVC extruded T-5 LED batten - integrated type in repairs of old unsv existing 36/40 Watt FTL fitting any type complete all as specified and as directed.
S&F in repairs of wall mounted LED integrated batten T-5 10 Watt - 2ft white 6500K, indoor decorative PVC extruded T-5 LED batten - integrated type in repairs of old unsv existing 36/40 Watt FTL fitting any type complete all as specified and as directed.
S&F in repairs of decorative wall light mounting suitable for LED lamp upto 15 Watt complete all as specified and as directed.
S&F in repairs of surface mounting round/square shape LED down lighter 12 Watt complete with including new flexible wire as requried on site in repairs of old unsv existing ceiling light fitting complete all as specified and as directed.
S&F in repairs of LED 10 Watt white bulk head in engineering plastic housing with clear prismatic including required LED bulb and all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete all as specified and as directed.
S&F in repairs of LED rechargable bulb 15 Watt B-22 Cap, AC 230V, 50 Hz suitable for Batten Holder/Bulk head/SK light fittings in repairs of old unsv lights any type complete all as specified and as directed.
S&F in repairs of recessed/surface mounting 36 watt 2' x 2' flat LED panel fitting with soft light and glare free symetrical ilumination suitable for RCC/POP ceiling supplied with wedge bracket to fix in existing ceiling in repairs of existing old unsv CFL fitting any type from ceiling of common areas and making good disturbed surface/POP ceiling to match and getting electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and as directed.
M&L for concealed point wiring complete with stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable drawn through concealed PVC conduit in wall and Existing conduit in ceiling and including replacement of unserviceable pressed steel terminal boxes with Modular steel terminal boxes including white cover modular plate with frame suitable for modular switches, modular sockets, modular fan regulators etc of required size complete including 1.5 sqmm copper cable earth continuity wire to common earth and connected to earth dolly complete all as specified and as directed. Note :- The rate is inclusive cutting/chasing and making good disturbed surface with CM 1:3 and same surface finishs with the adjoining surface of disturbed area with OBD/Colour wash/white wash complete. One light /fan/Bell point/security light controlled by one way switch
All as per Srl item No.56 above, but one 3 pin socket outlet 5 amps on same board.
All as per Srl item No.56 above, but one 3 pin socket outlet 5 amps point independent board with cable 1.5 Sqmm for main current and 1.5 sqmm as earth wire as power point.
All as per Srl item No.56 above, but one 3 pin socket outlet, 15 amps on independent board with cable 2.5 Sqmm for main current and 2.5 sqmm as earth wire as power point.
S&F switch Modular type switch, 6 A 1- way SP switch complete all as specified and as directed.
S&F modular type 2/3 pin combined shuttered type 6A socket complete all as specified and as directed.
S&F switch Modular type switch, 16 A 1- way SP switch complete all as specified and as directed.
S&F modular type 2/3 pin combined shuttered type 16 A socket complete all as specified and as directed.
S&F Fan regulator-2M,100W Dura ISI mark complete all as specified and as directed.
S&F modular bell push complet all as specified and as directed.
Note :- The contract sum shall be after deducting the amount of Credit shown in Sch of Credit of this Tender.
J V ENGINEERS / JAI SINGH
Chaudhary Constructions
Vijeta Solutions
M P TYAGI ENGINEERS AND CONTRACTORS
P R Constructions
H.B. Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .