Tender Value
Refer Docs
EMD Value
₹4,020
Closing Date
26 Feb 2024, 9:00 amClosed
Resident Engineer
Bhaba Power House Division, HPSEBL,Bhabanagar
Repair maintenance of 22KV HT Line Old Feeder and New feeder from Nathpa Substation to BAP Kafnu Power House
2024_HPSEB_85970_1
HPSEBL/BPHD/2023-24-20
Limited
Repair and Maintenance Works
Item Rate
45 days
Between BAP and Nathpa Substation
Please refer Tender documents.
5 documents required · 5 mandatory
₹590
₹4,020
Yes
6 Mar 2024
15 Feb 2024
26 Feb 2024
15 Feb 2024
26 Feb 2024
15 Feb 2024
Scope of Work
De- stringing conductor of OLD project feeder (Line-II) 6/1/3.35 mm sq. and rollong of conductor and keeping it at safe place till its resagging. Re-sagging of 3 phase ACSR conductor 6/1/3.35 mm conductor per meter i.e laying, stringging, sagging, winding, jointing complete in all respect as per REC standards and to the entire satisfaction of EIC.
De- stringing conductor of NEW project feeder (Line-I) 6/1/3.35 sq. mm and rollong of conductor and keeping it at safe place till its resagging. Re-sagging of 3 phase ACSR conductor 6/1/3.35 mm conductor per meter i.e laying, stringging, sagging, winding, jointing complete in all respect as per REC standards and to the entire satisfaction of EIC.
Shifting of 6 Nos. Single pole structures of 22 KV HT Line (New Project Feeder) from Nathpa S/s to BAP Kafnoo: - - Dismentling of 06 No. single pole structures of 22 KV line along with its associated accessories by manual excuvation of pit and removing soil around poles and then manual lifting of pole to the desired place along with de-stringging of conductor(6/1/3.35 sq. mm). - Erection of 6 Nos. single pole structure i.e. 6 Nos. 11 meter long Steel Tabular Pole with associated accessories, local muffing complete in all respect i.e. digging of earth pit, filling of soil in the pits, fixing of cross arms, fixing of danger plate and fixing of 6 Nos. stay set to single pole structures along with stringing of conductor (6/1/3.35 sq. mm) as per the entire satisfaction of Engineer In-Charge (EIC).
Providing, erection and fixing of 15 Nos. Stay set complete in all respect i.e. digging of pits, fixing of Stay rods, nozzeling, tightening etc. as per REC standards and to the entire satisfaction of Engineer In-Charge (EIC).
Repair & repacement/renewal of all defective parts of 2 Nos G.O switches, one at sherpa colony on 22 KV new projecct feeder Line-I and one at Bahi on 22 kV old project feeder Line-II: - -Replacement/renewal of 06 Nos. burnt/damaged male/moving contact blades, 06 Nos. burnt/damaged female contact blades and 06 nos. pedestal in 22 KV HT Line New project feeder from Nathpa sub station to BAP Kafnoo Power House, HPSEBL, Katgaon as per requirement and direction of Engineer Incharge.
Providing and replacement/renewal of 06 Nos. polymeric type Lighting Arrester/Surge Arrester of following specification: - Voltage level = 22 KV, Isc = 16 KA, In = 5 KA, Class- D, 50/60HZ, Uc - 14.4 KV to Ur - 18 KV, Model No. DAO -18D, for 22 KV Switchyard, Make: - Raychem RPG .
Providing and replacement of 1 Nos. G.O. Switch, at Bahi on 22 KV old Project Feeder Line 11 emanating from Kafnoo to 66/22 KV sub-station Nathpa under Bhaba Electrical Sub Div. No. I, Katgaon.
VINOD CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .