| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC VILL BATABARI PO DALGAON PS DALGAON DARRANG ASSAM 784116 | DARRANG | ASSAM | 784116 | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L2₹27.3 L+₹2.0 L (7.87%)Rejected-Finance THIS INFORMATION IS NOT AVAILABLE IN THE PROVIDED DOCUMENT | KAMRUP METRO | ASSAM | 781005 | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹28.9 L+₹3.6 L (14.3%)Rejected-Finance HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | L3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | L4₹29.5 L+₹4.2 L (16.6%)Rejected-Finance P O RANGIA WARD NO 3 DIST KAMRUP ASSAM | KAMRUP | ASSAM | 781354 | L4 | Rejected-Finance BEING L4 BIDDER |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
11 Dec 2021, 6:00 pmClosed
GE RANGIA
GE Rangia C/O 99 APO Rangia
SPECIAL REPAIRS TO BUILDING NO. ET-129 (RICE SHED) AT RANGIA AND OTHER SANCTIONED WORKS AT RANGIA AND CHANGSARI MILITARY STATION UNDER GE RANGIA
2021_MES_481279_2
8497/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
RANGIA AND CHANGSARI
AS PER NIT
9 documents required · 9 mandatory
₹500
GE RANGIA
₹54,000
Yes
13 Jan 2022
22 Nov 2021
18 Dec 2021
22 Nov 2021
11 Dec 2021
29 Nov 2021
Amount
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and as directed by Engineer-in-charge.
Taking down chowkat or frame exceeding 1.5 Sqm each (without taking off shutter from the frame), complete all as specified and as directed by Engineer-in-charge.
Taking down chowkat or frame not exceeding 1.5 Sqm each (without taking off shutter from the frame), complete all as specified and as directed by Engineer-in-charge.
Demolition of unreinforced cement concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specificied provided for, complete all as per specified and as directed by Engineer-in-charge.
Dismantling Asbestos Cement (Corrugated, Semi corrugated etc.) sheets in roof coverings, complete all as specified and as directed by Engineer-in-charge.
S&F Solid PVC Door Frame of size 50mm x 95mm made out of 5mm single side prelam PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with prelam sheet, reinforced with M.S Square tube complete all as per specified and as directed by Engineer-in-charge.
S&F Factory Made Solid PVC moulded Door Shutter (with wood free EPS) 28 to 30mm thick (style) with 2,4, or 6 raised panel design with 2mm thick moulded prelam sheet on the front face and 2mm prelam PVC sheet on back face complete as per manufacturer's instruction and all as per specified and as directed by Engineer-in-charge.
S&F Factory made solid wire gauzed pvc door shutter 30mm thick (style) consisting of frame made out of M.S.tubes for top & bottom rails.M.S.frame shall be covered with heat moulded prelam PVC "C" channel having a prelam PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panells will be wire gaused in lieu of single side prelam PVC sheet panel. The wire gause shall be wrapped on an additional square 8 mm MS solid tube and this tube shall be welded to MS tubes. The wire gause shall be stretched to tighten firmly. And jointed to gether with solvent cement, suppling & fixing in the frame at site complete all as per specified and as directed by Engineer-in-charge.
S&F in repair brass 4 layers mortice lock, vertical type, size 65 mm fixed, complete all as specified and as directed by Engineer-in-charge.
Demolition of brick work built in any cement mortar complete all as specified and as directed by Engineer-in-charge.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc. 6m mean radius in cement mortar 1:6, complete all as per specified and as directed by Engineer-in-charge.
M&L for brick work with sub-class `B' old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
M&L for 15 mm thick rendering on fair faces of brick work or one side of lathing in cement mortar (1:4), mixing with water proofing compound @2% by weight of cement consumed and surface finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. Note: WPC shall be measured and paid separately as supply only under relevent item.
M&L rendering 10mm thick on other than fair faces of brick work or concrete surface in cement mortar 1:6, surface to be finished fair & even without using extra cement, complete all as specified and as directed by Engineer-in-charge.
Supply only integral water proofing compound confirming to IS complete all as per specified and as directed by Engineer-in-charge.
M&L 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in flooring/ hard standing/sub-base/plinth protections, finished even and smooth without using extra cement complete all as per specified and as directed by Engineer-in-charge.
M&L 25 mm thick Cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) as in floor finished rough, complete all as per specified and as directed by Engineer-in-charge.
S&F galvanised mild steel wire cloth, 0.63 mm dia of wire and average width of aperture 1.4 mm and fixed with galvanised wire staples, complete all as specified and as directed by Engineer-in-charge.
S&F in repair galvanised mild steel wire cloth, 0.63 mm dia of wire and average width of aperture 1.4 mm and fixed with galvanised wire staples, complete all as specified and as directed by Engineer-in-charge.
M&L for steel windows with side hung shuttres including box type hinges with steel handle and steel peg stay ,complete without glazing bars, dovetailed or welded, complete all as per specified and as directed by Engineer-in-charge.
M&L for steel windows with side hung shutter including projecting type hinges with steel handle and steel peg stay ,complete with glazing bars,dovetailed or welded, complete all as per specified and as directed by Engineer-in-charge.
M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as per specified and as directed by Engineer-in-charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and as directed by Engineer-in-charge.
S&F 3 mm thick sheet glass, ordinary quality in squares not exceeding 0.5 Sqm in each pane fixed with cut & mitred beads, complete all as specified and as directed by Engineer-in-charge.
S&F aluminium handle cast type anodised 125 mm size complete all as specified and as directed by Engineer-in-charge.
S&F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
'S&F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as per specified and as directed by Engineer-in-charge.
S&F 125 mm long medium weight, cold rolled mild steel butt hinges, complete all as specified and as directed by Engineer-in-charge.
S&F floor door stopper 14cm long of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor complete all as per specified and as directed by Engineer-in-charge.
S&F 300mm, ordinary rat tail rod pattern springs including roller and roller plate, complete all as per specified and as directed by Engineer-in-charge.
Dismantling Unframed timber scantlings 40 Sqcm and over in section and in any position, complete all as specified and as directed by Engineer-in-charge.
M&L 2nd class hard wood in scantling wrought timber unframed and fixed, complete all as specified and as directed by Engineer-in-charge.
Dismantling boarding, any description fixed in any position with nails, complete all as specified and as directed by Engineer-in-charge.
M&L for 50 mm thick 2nd class hard wood boarding supplied and fixed with nails in any situation (except flooring and skirting) plained one side with butt joints complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing surfaces of wood and wood based materials, new or old of any description and girth, not otherwise described and treated with two coats of cresote oil, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated wood or wood based surfaces of any description, exceeding 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge.
M&L for forming construction joint 30 mm deep x 10 mm wide filled with sealing compound grade "A", complete all as specified and as directed by Engineer-in-charge.
M&L plain cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in surface channels and drains complete all as specified and as directed by Engineer-in-charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends complete all as specified and as directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated or semi-corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge.
M&L for RCC type A-I (1:1.5:3) as in chajjas/lintel complete all as per specified and as directed by Engineer-in-charge.
M&L for RCC type A-I (1:1.5:3) as in column, post complete all as per specified and as directed by Engineer-in-charge.
M&L for form work for side of pillars, posts, columns & similar works vertical or batter complete all as specified and as directed by Engineer-in-charge.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., complete all as per specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality confirming to Fe-410-S 0r Fe-410-O, complete all as per specified and as directed by Engineer-in-charge.
Dismantling mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-Charge.
S&F MS steel work in tubular trusses including special shaped washers etc., complete using ERW or induction butt welded tubes confirming to IS 1161- 1979 graded St 240, complete all as per specified and as directed by Engineer-in-charge.
M&L for steel ventilators with top hung shutter including hinges, steel peg stay, complete all as per specified and as directed by Engineer-in-charge.
M&L for MS rolled section of grade Fe-410-0 or Fe-310-0 (beam, tee, angle channel ot flat section) as in roof trusses (framed), trussed purlins, crane gantries rails, and fastening and heavy bracket framing including destance pieces, wind tie, cleats etc. and one coat of zinc chromate primer & paint complete all as specified and as directed by Engineer-in-charge.
All as per above item No 52, but erection and fixing only.
M&L for preparation of new or previously untreated steel or iron surface of any description and applying two coats of synthetic enamel paint over a coat of red oxide, primer over 10cm width or girth complete all as specified and as directed by Engineer-in-charge.
Dismantling of unframed fillets, rails, posts, rafters, purlins etc., under 40 Sqcm in section, complete all as specified and as directed by Engineer-in-charge.
M&L second class hard wood plain fillets, square or rectangular or triangular in section, clean sawn, secured with nails or brads having sectional area exceeding 6 sqcm but not exceeding 13 sqcm complete all as specified and as directed by Engineer-in-charge.
M&L in repair GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated wood or wood based surfaces of any description, not exceeding 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge.
M&L preparation of old painted steel and iron surfaces of any description over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint, complete all as per specified and as directed by Engineer-in-charge.
M&L for ATT at points of contract of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as per specified and as directed by Engineer-in-charge.
M&L for complete removal of existing treatment of old distempared surfaces and applying two coat of oil bound distemper on walls over 1 mm thick wall putty including one coat of chalk whiting primer, complete all as per specified and as directed by Engineer-in-charge.
M&L for 15 mm thick screed bed or bedding layer of cement mortar (1:6) for laying floor finishes, complete all as specified and as directed by Engineer-in-charge.
M&L 10mm thick backing coat in CM 1:4 on brick or concrete surfaces for fixing of wall tiles as in dado/skirting complete all as specified and as directed by Engineer-in-charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation,etc) or insulation board/Slabs/blankets of any thickness including cover fillets, complete all as specified and as directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as per specified and as directed by Engineer-in-charge.
S&F non-skid ceramic colour tiles 7 to 8 mm thick (Square/rectangular) area of each tile 600mmx600 mm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles complete all as per specified and as directed by Engineer-in-charge.
All as per above item No 66, but on vertical surface surface
S&F exposed GI powder coated snap grid frame of false ceiling 600 X 600 mm size of wall angle 25 X25 X 0.30mm size cross Tee 22 X 35 X 0.60mm with 4mm dia G.I. suspender fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm including supply and fixing of 4 mm thick E- board in false ceiling including fixing arrangement from roof and applying three coats of white wash on exposed surfaces complete all as per specified and as directed by Engineer-in-charge.
S&F Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles complete all as per specified and as directed by Engineer-in-charge.
S&F Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in vertical surface etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles complete all as per specified and as directed by Engineer-in-charge.
S&F exposed GI powder coated snap grid frame of false ceiling 600 X 600 mm size of wall angle 25 X25 X 0.35mm size cross Tee 24 X 38 X 0.70mm with 4mm dia G.I. suspender fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm including supply and fixing of 6 mm thick E- board in false ceiling including fixing arrangement from roof and applying three coats of white wash on exposed surfaces complete all as per specified and as directed by Engineer-in-charge. (Note- Rate included for lowering / shortening of electric fittings such as fan, light fittings etc.)
M&L 6 mm thick Asbestos Cement sheet, corrugated, or semi corrugated sheets in roofs, walls etc. and fixed with fixed with L-type or J-type or cranked hook bolts, complete all as specified and as directed by Engineer-in-charge.
M&L for rendering 15mm thick on fair faces of brick work or one side of lathing in cement mortar 1:4 , surface finished even and smooth without using extra cement using water proofing compound in top layers as per manufacturer's direction complete all as per specified and as directed by Engineer-in-charge. Note - WPC shall be measured and paid saparately.
M&L applying two coats of distemper over a coat of 3 mm thick a layer of wall care putty on walls including preparation of surface complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing new plastered surfaces and applying two coats of cement based paint on walls over a coat of alkali resistant primer, complete all as per specified and as directed by Engineer-in-charge.
M&L for two coats of cement based paint on walls over a coat of alkali resistant primer, including complete removal of existing treatment complete all as per specified and as directed by Engineer-in-charge.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with prelam sheet, reinforced with M.S Square tube complete all as per specified and as directed by Engineer-in-charge.
S&F 100 mm long medium weight, cold rolled mild steel butt hinges, complete all as specified and as directed by Engineer-in-charge.
S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair Stainless steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.40 mm and fixed with tinned stacks, or galvanized wire staples complete all as per specified and as directed by Engineer-in-charge.
S&F 3 mm thick figured glass in squares not exc. 0.5 sqm in each pane glazing with oil putty complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of old painted surfaces of wood and wood based materials of any description, not otherwise described and applying one coat of Synthetic enamel paint over 10 cm width or girth, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paint complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D2 ( using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as per specified and as directed by Engineer-in-charge.
M&L for hard core of gauge exc. 63 mm but not exc.100 mm, deposited, spread and levelled in layers not exc. 150mm thick, watered and rolled/rammed to a true surface complete all as specified and as directed by Engineer-in-charge.
M&L for 100 mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) in flooring/ hard standing laid in alternate bays including finishing the surface even and fair without using extra cement, complete all as specified and as directed by Engineer-in-charge.
Excavation in post holes (or similar holes) each n.exc 0.5cum in soft/loose soil and getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering and removing of surplus soil to a distance n.exc 50 meters and making good surface, complete all as per specified and as directed by Engineer-in-charge.
S&F Rolled Mild Steel sections confirming to Fe 410 - W as in main and cross beams, hip and jack rafters; purlins where connected to common rafters fixed with angle cleats or other connecting plates complete all as per specified and as directed by Engineer-in-charge.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
S&F chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as per specified and as directed by Engineer-in-charge.
M&L for PCC (1:2:4) type B-1 ( using 20 mm grade crushed stone aggregate) as in copping roof kerbs or mud stops, bed plates, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets with necessary form work as required complete all as specified and as directed by Engineer-in-charge.
S&F anodised Aluminium sliding window and ventilator frame made up 62 mm /29.5 mm 1.5 mm thick aluminium section & shutter made up 38 mm / 20 mm/1.5 mm thick without sash bar aluminium section including all necessary joining cleats, hold fast, rubber gasket, anodised snap beading, anodised aluminium fittings, suitable aluminium handle and locking arrangment etc. including taking down old unserviceable one, complete all as per specified and as directed by Engineer-in-charge.
S&F anodised aluminium door using 96.6mm X 44.8 mm X 1.5 mm aluminium chowkhats, 84.0 x44.7mmX1.5mm section vertical styles and 101. 60X44.88X1.5mm rails mounted 04 Nos SS butt hinges 100 mm for each shutter with hydraulic door closer, mortice lock six lever vertical type mild steel 100 mm size, 02 Nos tower bolt 150 mm , sliding bolt 300 mm long 01 No, 200 mm 2 Nos door handles and fittings, bottom panel and top panel fixed with snap beading rubber of suitable size including taking down old unserviceable one, complete all as per specified and as directed by Engineer-in-charge.
S&F Stainless steel wire cloth, 0.56 mm dia of wire and average width of aperture 1.18 mm and fixed with tinned tacles or galvanised wire staples, complete all as specified and as directed by Engineer-in-charge.
Taking down carefully aluminum/copper point wiring (light fan, socket or power) complete including fittings and fixtures such as switches, sockets, light fittings, ceiling rose, pendants, lamp holders, shade conical, regulators etc and removing unserviceable fittings and fixtures with wiring cable, battens, wooden boards etc from site and making good disturbed surfaces of walls, floors, ceiling etc all complete all as specified and directed complete all as per specified and as directed by Engineer-in-charge.
Taking down carefully unserviceable main switches and DB’s including wooden boards and removing from site including making good disturbed surfaces of walls complete all as per specified and as directed by Engineer-in-charge.
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends . elbow crosses etc with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings etc like switches sockets and fan regulator incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly complete all as specified and as directed for one light point controlled by one switch, complete all as per specified and as directed by Engineer-in-Charge.
All as per serial item No. 101 above but for exhaust/ceiling fan point controlled.
All as per serial item No. 101 above but for one 3 pin socket outlet 5 AMPs on independent board.
All as per serial item No. 101 above but for one 3 pin socket outlet 5 AMPs on same board.
All as per serial item No. 101 above but with 4 sqmm (nominal area) cable with 4.00 sq mm size copper earth continuity conductor of green colour for 15 A socket outlet on independent boards.
Supply and fix switch socket combination 05/16 Amp, 5 in 1, flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch socket combination 2 in 1,6 Amp 3 pin flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix socket outlet, 3 pin 6/5 Amps, flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch piano flush type, 5 / 6 Amps 240 volts single pole one way, complete all as specified and as directed by Engineer-in-charge.
Supply and fix ceiling rose surface backelite three terminals, PVC/polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed by Engineer-in-charge.
S&F wall security light fittings 1x 15 Watt LED New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP openning seperate driver compartment with IP65 protection and impact resistance of IK07, complete all as specified and as directed by Engineer-in-charge.
S&F street light bracket made out of GI tubing 25 mm bore medium grade 1.20 Mtr long bend to required shape as in bracket for street light fittings fixed with two pair or MS flat iron 40mm x 5mm size and 30cm long clamp of required shape with bolts nuts and washers suitable for steel tubular pole including painting of mild steel flat iron surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet metal enclosure powder painted for MCB SPN 8 way double door DB with din rail and suitable bus bar complete all as specified and as directed by Engineer-in-charge.
S&F PVC rectangular block for mounting, DBs, etc. with 3mm thick plastic laminated sheet cover of size 250 x 200 x 50 mm deep complete all as specified and as directed by Engineer-in-charge.
Supply and fix MCB SPN 240 Volts 6-32 Amp breaking capacity 10 KA rating, complete all as specified and as directed by Engineer-in-charge.
Supply and fix MCB SP 240 Volts 6 to 32 Amps breaking capacity 10 KA rating complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repair 16 Sqmm 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and as directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down old unserviceable one, complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F PVC terminal boxes 18 module for mounting mounting of DBs with 2 mm thick plastic laminated sheet cover complete all as specified and as directed by Engineer-in-charge.
Supplying and fixing 10 Sqmm, twin core, flat cable 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge.
S&F exhaust fan refresh air of size 300 mm sweep, 230 Volt single phase, Metalic body, outside opening louvers, fixed in wall including cutting of wall to suitable size to fix the exhaust fan with nut bolts etc., complete all as specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S Rajkamal Enterprise
M/S SEWAK SINGH
MUKUL CHOUDHURY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .