Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-Finance 4 AND 5 DDA MARKET 4 AND 5 DDA SHOPPING COMPLEX SOUTH EXTENSION PART 1 SOUTH EXTENSION PART I | L1 | Accepted-Finance ok | |
| 2 | L2₹14.3 L+₹35,369.10 (2.54%)Accepted-Finance GROUND FLOOR G 1154 A MANSAROVAR PARK SHAHDARA DELHI 110032 | SHAHDARA | DELHI | 110032 | L2 | Accepted-Finance ok | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹14.1 L
EMD Value
₹28,295
Closing Date
13 Mar 2026, 3:00 pmClosed
Executive Engineer (E) M 253 PWD
Executive Engineer (E) M 253 PWD, Delhi Sachivalaya, New Delhi
RMO EandM services installed at Delhi Sachivalaya New Delhi during 2025-26 AMC of Daikin Make VRF VRV type equipment
2026_PWD_288299_1
123/EE(E)/PWD M-253/2025-26
Open Tender
Electrical Works
Percentage
365 days
M 253 PWD, Delhi Sachivalaya, New Delhi
Please refer Tender documents.
14 documents required · 14 mandatory
₹0
₹28,295
17 Mar 2026
7 Mar 2026
13 Mar 2026
7 Mar 2026
13 Mar 2026
7 Mar 2026
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority: Executive Engineer(E) PWD M-253
Name of Work:- RMO E&M services installed at Delhi Sachivalaya New Delhi during 2025-26 (SH: AMC of Daikin Make VRF/VRV type equipment )
NIT No.:123/EE(E)/PWD M-253/2025-26 Estimated Cost:-14,14,764/-
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Sub Head Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1 AMC of VRF Air-conditioning system with following specifications:- Air cooled outdoor unit having all hermetically sealed inverter type Scroll Compressor(s) ,minimum two compressors for above 14HP modules, microprocessor based Controller,top discharge type condensing unit(s), with 410A Refrigerant, vibration isolators This AMC shall include repair/ replacement of PCB cards,Fan motor, Transformer, Magnetic switch, motors, compressors, sensor, top up for both indoor and outdoor units and all defective accessories for VRF /VRV System. Preventive Maintenace and breakdown maintenance shall include in this AMC. (Qty :-84 hp) Months 70623 374800 Excess(+) Full Conversion INR
2 Providing gas recharge in a existing VRV/VRF air conditioning system due to environmentel corrosion i/c checking system pressure, temperature, low gas symptoms, cooling ineffeciency, oil traces, nitrogen pressure testing, soap solution test, welding of identified leaking joints, deep vaccuming system, mositure removal from the refrigent and recharging referigent gas R410A refrigent, to ensure proper cooling performance and system efficenency. kg 1289 374800 Excess(+) Full Conversion INR
3 Providing of Anti corrosive paint on the condenser coils, copper joints etc. to avoid corrosion damage. The coatings shall act as a shield, preventing corrosive agents such as pollutants and high levels of sulfuric acid in the air which triggers the chemical reaction that corrodes the copper etc. complete as reqd. 6 Hp to 12 HP ODU nos 10904 374800 Excess(+) Full Conversion INR
4 12 HP to 20 HP ODU nos 13630 374800 Excess(+) Full Conversion INR
5 4 way cassatte indoor nos 374800 Excess(+) Full Conversion INR
6 1 way cassatte indoor nos 3181 374800 Excess(+) Full Conversion INR
7 Ductable indoor upto 4.5 HP nos 4089 374800 Excess(+) Full Conversion INR
8 Ductable indoor upto 8.5 HP nos 5907 374800 Excess(+) Full Conversion INR
9 Comprehensive Annual Maintenance contract and services charges for 11 TR Package/Ductable Daikin Air Conditioners installed at Delhi Sachivalaya Building, New Delhi which includes supply and replacement of components found defective, servicing, repairing, rectification of thermostat relay, PCB fan motor, electrical wiring, gas charging if found necessary including replacement/repairing of sealed compressor, fan motor , PCB , transfomer and other electrical parts etc. complete as required – 2 Nos Months 8809 374800 Excess(+) Full Conversion INR
10 Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet sqm 1213 374800 Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.13 MB
BOQ_382288.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .