Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹188.7 Cr
EMD Value
₹3.8 Cr
Closing Date
29 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ADDITIONAL CHIEF ENGINEER
Office of the Additional Chief Engineer PHED, Jaipur Region II Near RBI Colony, Gandhi Nagar, Jaipur
Bids for the work of Providing Water Supply From Bisalpur Jaipur System for RWSS of 130 nos Villages of Sanganer Block District Jaipur under JJM with O and M for 10 Years after DLP of 1 Year
2025_PHCJA_523080_1
NIT NO-18/2025-26/ACE PHED REGION-II/JAIPUR
Open Tender
Civil Works - Water Works
Percentage
600 days
SANGANER JAIPUR
Please refer Tender documents.
4 documents required · 4 mandatory
₹25,000
EE PHED DD-I/MD RISL JAIPUR
₹3.8 Cr
Yes
CHIEF ENGINEER JJM PHED
16 Jan 2026
24 Dec 2025
30 Jan 2026
24 Dec 2025
29 Jan 2026
9 Jan 2026
6 Jan 2026
Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in- charge.(excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
100 mm dia
150 mm dia
200 mm dia
250 mm dia
300 mm dia
350 mm dia
Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M. HDPE PE-100 PN-6
63 mm dia
75 mm dia
90 mm dia
110 mm dia
Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M. HDPE PE-100 PN-6
125 mm dia
140 mm dia
160 mm dia
180 mm dia
200 mm dia
225 mm dia
Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification.
300 mm Dia 8 mm thick casing pipe with protective coating.
400 mm Dia 8 mm thick casing pipe with protective coating.
600 mm Dia 10 mm thick casing pipe with protective coating.
Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. Note: The rates for DI double flanged pipes shall be reduced 5%, if used other than OHSR pipes.
400 mm dia
Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.
100 mm dia
150 mm dia
200 mm dia
250 mm dia
Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. For Pump Piping
100 mm dia 6.0 mm thick
150 mm dia 6.0 mm thick
200 mm dia 6.0 mm thick
250 mm dia 6.0 mm thick
300 mm dia 6.0 mm thick
350 mm dia 6.0 mm thick
400 mm dia 6.0 mm thick
800 mm dia 8.0 mm thick
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.
In all types of Soils
upto 1.5 m
In Soft Rock
upto 1.5 m
In Hard Rock (Blasting Required)
upto 1.5 m
In Hard Rock (Blasting Probihited)
upto 1.5 m
Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date) Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, FloatLP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside .Fasteners - CS/ Galvanised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with DI metal seated D/F Non rising stem. Sluice Valves as per (IS: 14846 amended upto date) PN 1.6 ratings. Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work Class PN 1.6
40 mm dia
50 mm dia
80 mm dia
Construction of RCC air valve pillar including GI pipes, flanges, bend, MS clamps, rubber sheet, nut bolts/jointing materials etc in M-20 grade cement concrete of 2m height from Natural Ground Level in required shape and size as per approved drawing in all types of soils/rock disposing of surplus excavated materials within a lead of 50 m as per approved drawing complete including all charges at appropriate location in pipeline as per specification mentioned in the scope of work and as per direction of Engineer In Charge. MS pipes and fittings of dia.
Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
80 mm dia
100 mm dia
125 mm dia
150 mm dia
200 mm dia
250 mm dia
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Manually Operated Resilient Seated Sluice Valves of Class PN 1.6
80 mm dia
100 mm dia
150 mm dia
200 mm dia
250 mm dia
300 mm dia
350 mm dia
400 mm dia
500 mm dia
800 mm dia
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirfing to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6
100 mm dia
150 mm dia
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0
80 mm dia
100 mm dia
125 mm dia
150 mm dia
200 mm dia
250 mm dia
300 mm dia
350 mm dia
500 mm dia
Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (Fabricated Steel) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer.
100 mm dia
150 mm dia
200 mm dia
250 mm dia
300 mm dia
350 mm dia
400 mm dia
800 mm dia
Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR "O "ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Class PN 1.6, Manually Operated with Gear
350 mm dia
Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR "O "ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Class PN 1.6, Motorised Operated
200 mm dia
300 mm dia
350 mm dia
Construction of Valve Chamber in required size and shape as per drawing including required excavation of earth in all types of soil such as murrum, sand, sandy silt, black cotton soil, hard soil, kankar and all types of rocks etc.,disposing of surplus excavated material within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it withcovering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in charge
1200 mm x 900 mm x 1450 mm (upto 150 mm dia)
1500 mm x 1200 mm x 1550 mm (upto 350 mm dia)
Construction of Junction Chamber in required size and shape as per drawing including required excavation of earth in all types of soil such as murrum, sand, sandy silt, black cotton soil, hard soil, kankar and all types of rocks etc.,disposing of surplus excavated material within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in charge
SITC of Bulk Flow Meter with removable mechanism class "B" confirming to ISO:4064:2005/ IS: 2373 of approved make of following dia sized pipelines and specifications complete: Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68, Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.
100 mm dia
150 mm dia
Construction of Village Transfer Chambers
Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.
Bituminous courses
Granular courses
Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.
Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.
Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.
M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
Removing & Re-fixing of Precast concrete interlocking blocks by manual, stacking of severciable & un serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlocking block and cost of required new precast concrete interlocking block, all lead and lift as per general specifications. (Interlocking block manufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001 Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm)
100 mm thick
Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix
Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc.
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code)
Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
Up to 5.5 KW (7.5 HP) & head up to 120 mtr.
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.
Above 5 HP and up to 10 HP
Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.
3 core 4.0 Sq.mm
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
10.0 Sq. mm 4 core
Providing & Lowering in tube well ISI marked GI Pipe “B" class as per IS:1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
50 mm dia
Providing , lowring laying , aligninng, fixing in position at all level/ depth C.I. class-B specials as per IS:1538, amended up to date in trench complete including all material, labour, testing and commissioning along with pipe line/ appurtenance as per Technical specification and as per direction of Engineer( Note:- E/W to be measured and paid seperately) plain ended CI specials including tail pice, spigot end and socket end.
Upto 300mm
120cm. high fencing with angle iron posts 50x50x6mm. placed at every 3 Mtr. apart 30cm. in ground embedded in cement concrete 1:3:6 50x50x6mm angle iron provided with four horizontal lines and two diagonals of black barbed wire between two posts G.I. staple including earth work in excavation etc. complete. fitted and fixed with
Providing Household Tap Connection as per technical specification and approved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittings in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. Note: Road cut and restoration is not part of this item and paid seperately.
For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.
Providing Household Tap Connection as per technical specification andapproved drawing as per relevant IS code (amended up to date) fromHDPE/uPVC/DI/AC/MS/GI pipe line up to consumer meter/premisesby using PP mechanical Integrated saddle with inbuilt flow controlvalve made out of SS316 designed for 5 LPM discharge at 0.5 barpressure , not exceeding the flow of 7 LPM at 2 bar and acompression elbow, moulded in single piece/ fusion welded(Complete job) including digging out suitable size of pits and trench forlaying service line in all kinds of soil; depositing and refilling of pit &jhiri with watering & ramming /compacting in layers and disposal ofsurplus excavated soil as directed with in a lead of 100 meter ;providing & fixing of all fitting duly approved in accordance withspecification for potable water including GM Full-way Valve (IS:778Mark) or wheel valve and specials with 20 mm nominal dia MDPE pipePE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Threelayered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and aboveground level using PPR-C pipe with standard PPR fittings/ GI pipes inthe premises for fixing a tap / meter box (excluding) ,includingaccessories with flushing, cleaning, disinfecting and testing of pipe linecomplete required for making of service connection complete in allrespect including labour charges . The service line should be laid atleast 45 cm below ground level. Note: Road cut and restoration is not part of this item and paidseparately.
For connection with 20 mm dia MDPE/PPR-C pipe length up to 05mtr.
P& F Bib cock (IS : 8931 mark), superior quality of approved make , brss 400 gm, 15 mm nominal bore.
Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be done by using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.
Add extra over item no 1.21 & 1.22 for providing 20 mm PE 80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr.
Civil work such as construction of pump House.
At Hargun ki Nagal Pump House
At Neota Pump House
At Ajairaipura Pump House
At Shaligrampura Pump House
At Bhated Pump House
At Phagodiyawala Pump House
At Nohara Pump House
Providing, installation, testing, trial run and commissioning of the following, as per specifications (HSC Pumps)
CPS-1 TO CHARANWALA @HARGUN KI NANGAL PROP CHARANWALA @HARGUN KI NANGAL EX ARCHARWALA PROP KAPOORWALA NS KAPOORWALA EX KHATIPURA NS route 16 LPS / 65 m head/22 KW (1W+1S)
CPS-5 TO DEHMI KALAN EX 100KL, DEHMI KALAN NS 350KL, AWANIYA PROP 150KL, KODAR PROP 100KL route 19 LPS / 65 m head/30 KW (1W+1S)
Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at syncronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
CPS-1 (HARGUN KI NANGAL)TO BALAWALA EX 50 KL, SHRIRAMPURA NS, SHRIRAMPURA EX, SITARAMPURA EX, RATLIYA EX, JAGNNATHPURA PROP route 12 LPS / 70 m head/18.5 KW (1W+1S)
CPS-2 (NEOTA) TO NEOTA PROP 200 KL , NEOTA EX , HASAMPURA,BASNEWATA EX, KALWARA EX 75, KALWARA PROP 200KL route 20 LPS / 37 m head/18.5 KW (1W+1S)
CPS-2 TO KHATWARA NS, KHATWARA EX, MAHAPURA PROP, MAHAPURA EX route 12 LPS / 65 m head/18.5 KW (1W+1S)
CPS-7 (AJAIRAJPURA) TO AJAIRAJPURA NS, SIRANI EX,CL-14-B-CHATARPURA EX route 11 LPS / 55 m head/15 KW (1W+1S)
CPS-4 (SALIGRAMPURA) TO SALIGRAMPURA EX, VIMALPURA NS, VIDHANI EX route 9 LPS / 35 m head/9.3 KW (1W+1S)
CPS-3 (BHATED) to BHATED EX, RAMSINGHPURA EX route 6 LPS / 30 m head/5.5 KW (1W+1S)
CPS-3 (BHATED) TO GANWAR JATAN EX, DADIYA PURSHOTTAMPURA EX, SURAJPURA PROP route 5 LPS / 50 m head/7.5 KW (1W+1S)
CPS-5 (PHAGODIYAWALA PH) TO SARANGPURA EX 70 KL, NARSINGHPURA NS 100KL route 5 LPS / 45 m head/7.5 KW (1W+1S)
CPS-5 TO THIKARIYA EX 100KL, RAMPURA BAS DEVLIYA PROP 100KL, SANJHARIYA EX 100KL, SANJHARIYA PROP 75KL route 12 LPS / 55 m head/15 KW (1W+1S)
CPS-5 TO SARANGPURA PROP, BHAMBHORIYA NS, BHAMBHORIYA EX, BAGRU KHURD EX, TILAWAS PROP, HARICHANDPURA NS, DEHMI KHURD NS route 20 LPS / 35 m head/15 KW (1W+1S)
CPS-6 (NOHARA PS) TO DAYALPURA PROP, VATIKA EX 300, VATIKA EX 300, MOHANPURA PROP route 26 LPS / 30 m head/18.5 KW (1W+1S)
CPS-6 (NOHARA PS), TO KHERI GOKULPURA EX, BADANPURA EX, GANWAR BRAHMAN EX, BAKSHA WALA NS route 8 LPS / 70 m head/15 KW (1W+1S)
CPS-6 (NOHARA PS) TO CL-25-C-SUKHDEOPURA @ NOHARA SAN, CL-25-C-SHYOSINGHPURA EX, CL-18-A-SUKHDEOPURA @ NATANI P, CL-25-A-ASAWALA P route 16 LPS / 45 m head/15 KW (1W+1S)
CPS-8 (MUHANA) TO CL-29-MUHANA EX, CL-29-MUHANA 2SAN,CL-28-PEEPLA BHARATSINGH P route 17 LPS / 45 m head/18.5 KW (1W+1S)
Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions. Note: Duty condition of required pump shall also be mentioned in BoQ.
IPS-01 Hargun Ki Nangal to CPS-08 Muhana (Tapping) - IPS-02 Neota route 67.4249257278669 LPS / 45 m head/55 KW (1W+1S)
IPS-01 Hargun Ki Nangal to CPS-03 Bhater - CPS-06 Nohara (Tapping) - CPS-04 Saligrampura route 86.0065285204991 LPS / 50 m head/75 KW (1W+1S)
IPS-01 Hargun Ki Nangal to Pawaliya. EX - Pawaliya 2SAN - Bhapura. EX - CPS-07 Ajayrajpura route 116.694141414141 LPS / 30 m head/55 KW (1W+1S)
CPS-05 PHAGORIYAWALA route 33 LPS / 55 m head/37 KW (1W+1S)
CPS-7 (AJAIRAJPURA) TO HASAMPURA EX, BHANKROTA KHURD PROP, LAXMINARAYANPURA NS, ANNOPPURA PROP, UTIRAMPURA NS, CHITROLI PROP route 22 LPS / 70 m head/30 KW (1W+1S)
CPS-4 TO GONER EX, GONER NS, SIROLI PROP, CHATARPURA EX, DANTLI EX, DANTLI NS route 25 LPS / 65 m head/37 KW (1W+1S)
CPS-6 (NOHARA PS) TO CL-20-A-KHETAPURA EX, CL-18-B-SHRI RAM KI NANGAL EX, CL-18-B-SHRI RAM KI NANGAL PRO, CL-25-B-JAISINGHPURA @ BAS B EX, CL-25-B-JAISINGHPURA @ BAS B 2SAN,CL-24-A-BEELWA KALAN EX,CL-24-C-MANPUR NAGALYA P route 26 LPS / 40 m head/22 KW (1W+1S)
Providing,installation, testing and commisioning of vacuum Feed Gas Chlorinator with all assessories and making connection with existing pipeline required including supply & instalation of trunnion roller support, auxillary container valve, fluxible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragm Valve on injector inlet & outlet, 32 OD uPVC pipe for chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GM gate valve on pump suction & delivery, 25 NB GM 'Y' type stainer on pump suction, 25 NB GM Check valve on pump delivery, pressure gauge with Isolated valve on pump delivery and chlorine booster pump with motor of required capacity complete in all respect as per specification and the direction of the Engineer.
Hargun ki Nagal 1 kg/hr capacity
Neota 1 kg/hr capacity
Bhated 1 kg/hr capacity
Saligrampura 1 kg/hr capacity
Phagodiyawala 1 kg/hr capacity
Nohara 1 kg/hr capacity
Ajairajpura 1 kg/hr capacity
Muhana 1 kg/hr capacity
Supply of Chlorine Tonner as per specifications with rollers complete in all respect as per the direction of Engineer.
Glycerine filled pressure gauges (0-10 kg)
Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and direction of Engineer In-Charge.
100 mm dia
150 mm dia
200 mm dia
300 mm dia
350 mm dia
SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.
100 mm dia
150 mm dia
200 mm dia
250 mm dia
300 mm dia
400 mm dia
Providing, lowering, aligning, fixing in position in pipe line, CI double flanged Dual plate check valave of approved make of following Pressure rating & dia complete, as per API: 594/ API: 598 and of following specifications: Body & Cover of Grey cast iron of IS:210/ FG200 , Disc / plates - Cast steel ,Disc seal ring of EPDM/ NBR (food grade quality) ,Body seat of SS ,Face to face dimensions as per API: 594 ,Flanges Drilled as per IS:1538. Epoxy (Non-Toxic & suitable for drinking water) applied on body & cover inside and outside . Shaft/Stop Pin of SS- AISI- 304/410 , Hinge SS AISI 316/304 / CS ,Spring SS AISI 316/304 , Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR "O "ring seal.Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel) ,Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.as per API: 594 and flanges as per ISS of approved make of following Class and dia complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
Class PN 1.0
100mm dia
Providing, lowering, aligning, fixing in position in pipe line, DI double flanged resilient seated Dual plate check valave of approved make of following Pressure rating & dia complete, as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,Spring SS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR "O "ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel) , Insersion rubber of black EPDM 6mm thick .Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Class PN 1.6
100 mm dia
150 mm dia
200 mm dia
300 mm dia
350 mm dia
Construction of Flow Meter Chamber 1500 x 1200 x 1550 mm 200-300 mm
Construction of Flow meter chamber
Supply, installation, testing and commissioning of MNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation of PV module on MS frame as per approved design and drawings. Mounting structure shall be suitably designed to withstand wind velocity up to 150km/hr. Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of >98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as per detailed technical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. and suitable provision shall be included in tender document. FOR LIGHTING PURPOSE
Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: -
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.
h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4
BHATER
AJAIRAJPURA
Design & Construction of clear Water Reservoirs of required capacity at following places, including its piping, fittings, etc complete in all respect as per the scope of work & specifications given in the tender document for the following sizes
IPS HARGUN KI NAGAL
Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: -
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. . b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.
h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE2,3
IPS NEOTA
PHAGODIYAWALA
NOHARA
Construction and commissioning of RCC flat slab Over Head Service Reservoir of following capacity and staging including all material and labour charges as per the Scope of work and Technical Specification, consisting of the following main activities: -
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface roof slab, and 600 mm height of the vertical wall. e) Successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the roof slab. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top Slab to bottom Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony and MS ladder with safety cage from balcony to top slab.
j) Providing and fixing water level indicator (float type). k) Providing and fixing of hand railing all around the balcony, roof and staircase, consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm p) CI/DI puddle collar shall be fixed in the bottom/slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 15 M
50 KL, Staging Height 15 m
75 KL, Staging Height 15 m
Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: -
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall. e) Conducting successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab. j) Providing and fixing water level indicator (float type).
k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm. p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II 18 M Staging
100 KL, staging Height 18 m
150 KL, staging Height 18 m
200 KL, staging Height 18 m
Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II 20 M Staging
100 KL, staging Height 20 m
250 KL, staging Height 20 m
Supply, installation, testing and commissioning of CI Float Valve (Auxiliary type) at Inlet of OHSR/GLSR including all necessary specials required
100 mm dia
Providing and fixing of flanged/ plain ended MS special of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depth in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.
MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet)
Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below: 1. Depth of foundation- 900 mm. 2. PCC in M-10, width -900 mm and thickness 100 mm, 3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonary in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm. 5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6. 6. Expansion joint shall be on every 30 mtr. 7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided. 8. Pillar for main gate 350x350 mm in size is part of boundary wall. 9. Cement paint of approved colour in 3 coat shall be done.
Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints.
Providing, lowering, laying, aligning, fixing in position CI Duckfoot bend in pipe line as per IS:1538 (amended up to date) suitable for potable water at all level/ depth including all material, labour hydraulic testing and commissioning as per technical specifications and as per direction of Engineer for following sizes:
100 mm dia
150 mm dia
200 mm dia
250 mm dia
Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 :
Upto 300 mm dia
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
Brick masonry with F.P.S. bricks of class designation 75 in foundation and plinth with bricks
Cement mortar 1 : 6 (1 cement : 6 coarse sand)
Providing and fixing angle iron frame 25 x 25 x 3mm for ventilators fixed with 24 gauge square mesh of 14 gauge stainless steel wire including 10 mm square bars at interval of 100 mm welded to frame with metal beading of 20 x 3mm complete in all respect as per technical specifications and drawings as per technical specification and as per direction of Engineer.
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding:
Old work (One or more coats).
Providing and fixing 50 mm dia G.I. steel pipe railing in 3 rows duly painted on medium weight steel channels (ISMC series) 100 mm x 50 mm, 1.2 metres high above ground, 2 m centre to centre, complete as per approved drawings including all material, labour.
Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods watering, rolling each layer with 1/2 tonne roller, or stone or steel rammers and rolling every 3rd and top- most layer with power roller of minimum 8-10 tonne capacity and dressing up in embankment for roads, flood banks marginal banks and guide banks or filling up ground depressions, lead up to 50 Mtr. and lift up to 1.5 Mtr.: All kinds of soil
upto 1.5 mtrs
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs, griders having slopes up to 15°, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases up to floor three level including curing, compaction, finishing with rendering in cement sand mortar 1 : 3 (1 cement : 3 coarse sand) and making good and joints excluding the cost of centering, shuttering and reinforcement : with 1 : 1 : 2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size).
Providing & fabricating steel reinforcement for R.C.C. work including cutting, bending, palcing in position and binding complete including cost of binding wire in foundations, Raft footing step Beams base of column etc. upto plinth level. Hot rolles deformed (IS:1139) cold twisted (IS:1786) bars.
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 Mtr. in width as well as 10 Sqm on plan including disposal of excavated earth upto 50 Mtr. and lift upto 1.5 Mtr. disposed soil to be levelled and neatly dressed : All Kind of spoil
Supply of dry manure including loading unloading transportation & stacking at site :
Goat Dungmanure
Supply of different varities of tree/ shrubs/ climbers according to height and age of the plant at site including loading/ unloading & transportation etc. complete :
Different varities of Climber 900 mm to 1500 mm
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.
M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing up to floor Three Level pre cast cement concrete string or lacing courses, copings, bed plates, anchor blocks, windows sills, shelves, louvers steps, staircases, etc. including carriage, hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand) cost of required centering, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surface, including all T & P, curing etc. complete:M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
Supply and erection of hot dipped galvanised steel swaged tubular pole conforming to IS: 2713-1980 (part I to II) with galvanised base plate of size 400mm x 400mm x 7mm in position including excavation of the pit and filling the same with C.C. of M-10 grade (1:3:6) from base plate to 50cm above ground level, with the help of steel frame not less than 40 cm dia up to 114.3mm outer dia and 50 cm beyond 114.3mm outer dia around the pole. Duly finished with cement plaster, earthing terminals , cable entry, GI cable sleeve complete as required. The pole shall be galvanised using ISI mark tube for structural purpose. (SEE TABLE ): 7.5 mt high- GROUP-1
P & F IP-65 protected street light luminaire on existing bracket LED street light fixture 30-40 watt
P/Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size- 10 Sq mm- 4 Core- Group-1
Providing and fixing cow catcher made of R.S. joist angles channels MS rounds including cutting welding and fabrication with priming coat of red oxide (as per design).
Construction of Soakage well in all types of soil 300mm thick dry stone masonry, top and bottom 300 mm course in CM 1 : 6, 80 mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C. flooring earthwork complete as per approved drawing including disposal of earth within a lead of 50 Mtr.
Size 300 cm dia outside & 300 cm depth
Construction of Septic Tank in all types of soil with 40 Cm. thick masonry in CM 1 : 6, 15 Cm. thick C.C. bed of 1 : 5 : 10, M-15 grade C.C. flooring & over stone slab covering, 80 mm thick slab, jointing of slab in CM 1 : 3 Ralthal, Kharanja, 50 mm thick stone partition walls, 20 mm thick plaster in CM 1 : 6 finished with neat floating cement, 4 Nos C.I. foot rests of approved design, two No. 450 mm dia 25 Kg. of each C.I. cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 Mtr.
Size 400 x 140 x 150 cm (for 50 users)
Providing Laying & Jointing glazed S.W. pipes grade "A" (IS : 651 Marked) of approved make with spun yarn & stiff mixture of cement mortar 1:1 excavation & refilling of earth in all types of soil upto 1.2 m. depth, S.W. fittings, including testing of joints etc. complete.
150mm dia
Providing and Laying C.C. 1 : 5 : 10 (stone aggregate 40 mm nominal size) all around S.W. pipe including 15 cm. thick bed concrete as per Rajasthan PWD specifications : (Width W = Diameter of pipe in Cm + 40 Cm.). (Excluding cost of pipe )
150mm dia
Providing and fixing G.I. pipes (External Work) with G.I. fittings (IS : 1239 Mark) including trenching & refilling earth etc.
25mm dia nominal bore
Providing and fixing Ball Cock (IS : 1703 Mark) with Rod & P.V.C. Ball complete.
Brass wt. 1000 gm 25 mm
Supply, Installation, Testing and commissioning of copper wound ISI marked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories like, conservator, Silicagel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Lifting lugs, Bi-directional Plain/ Flanged Rollers,Earthing terminal,Air relaese plug.Off load tap changer (+5% to -10% in steps of 2.5%), winding / Top oil temperature rise of 45°C/40°C, ISI marked drain valves, Dial type temperature gauge, first fill oil, Epoxy based paint etc having max. total losses as per energy efficiency level - 2 at basic Insulation level conforming to IS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 BEE star level - I as per Govt. of India, Ministry of power notification Dated 16th Dec., 2016. Transformers described as above and as per the following continuous rating
Supply, Installation, testing and commissioning of 11 KV Double Pole structure With Air Break SWITCH having following specifications : (a) DP : Double pole structure made of two nos. 9 meter long PCC poles (400 Kg) & 7 nos. MS Channel each of size 100 mmx50mmx2500mm complete with earthing of the structure as per REC standards in all respect with nuts, springs washers, clamps as required. (b) GO:Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3 phase, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 Nos pin insulator ,GI pipe of suitable length for operation. c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set / Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Post insulators. (c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators (d) LA:3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. (e) JUMPERS: 3 no 11kv acsr conductors mounted on pin type insularors as required. GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’
Supply, Installation, Testing & Commissioning of HT metering cubical panel as approved By DISCOMs fabricated out of 14 SWG CRCA sheet steel in two compartment & MS angle of size 60mmX6mm having provision for Following: (i) Provision for fixing Trivector Meter (To be supplied by DISCOMs) (ii) Provision for fixing of combined CT PT Set (To be supplied by DISCOMs) (iii)TT Block (iv) 6mm Bakelite sheet on all sides.
Earthing Schedule Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 40 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required.
50mm x 6mm copper strip
50mm x 6mm G.I. Strip
32mm x6mm G.I. Strip
25mm x 3mm G.I. ( Hot Dipped ) Strip
Providing & Laying XLPE insulated IS:7098/II/85 of approved make H.T.cable for working voltage 11 K.V.Un-Earthed with Stranded Compacted Circular Aluminium Conductor, Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated, Insulation Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanised flat steel strip armoured and overall Extruded PVC Type ST-2 Outer Sheathed cable direct in ground including excavation of 30cmx100cm size trench, 25cm layer of river sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection testing etc.as required of size.
3 core 120.0 Sq.mm
Providing & making heat shrinkable type indoor/outdoor/straight through terminations/joint kit of approved make suitable for XLPE insulated 11 KV cable, with required components, prepration of cable ends,testing etc. as required of following sizes .
3 core 120/150/185 Sq.mm
3 core 120/150/185/225 Sq.mm
Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection,Complete as per technical specifications and as directed by Engineer in charge.
300 SQMM, 3.5 CORE
120 SQMM, 3.5 CORE
50 SQMM, 3.5 CORE
240 SQMM, 3 CORE
95 SQMM, 3 CORE
70 SQMM, 3 CORE
50 SQMM, 3 CORE
35 SQMM, 3 CORE
25 SQMM, 3 CORE
16.0 SQMM, 3 CORE
10.0 SQMM, 3 CORE
4.0 SQMM, 3 CORE
Providing and laying XLPE/PVC insulated & PVC sheathed armoured control cables of 1.1 KV grade with copper conductor as per IS 1255 including excavation of 30 CmX75 Cm size trench 25 Cm thick under layer of sand and second class bricks covering, backfilling & compaction
4C x 2.5 sq.mm
8C x 2.5 sq.mm
Supply, Fabricating & installing following sizes of ladder type cable trays with rungs at span of 250 mm including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling/wall with suspenders and including painting as required.
100mm x 50mm x 1.6mm
150mm x 50mm x 1.6mm
300mm x 50mm x 1.6mm
Supply, Fabricating & installing following sizes of perforated cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with suspenders and including painting as required.
100mm x 50mm x 1.6mm
150mm x 50mm x 1.6mm
Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the matwith synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure "A" attached with this BSR . 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage 45 KV
415 V LT Panel SITC of floor mounted PMCC (Indoor, Dust proff IP-4X front operated with 2 mm thick sheet metal ompartmentalised) with all accessible parts, head shrinkable sleeves, SMC/DMC bus bar supports, padlocking facility on outgoing feeders etc.
250 A MCCB Incomer with metering CTs , multi fuction meter compatible to scada ,Ampermeter with SS,Voltmeter with SS,Indicating Lamps,Control Fuse,wiring etc.complete in all respect. Size:900(W)X2400(H)X1000(D)
250 A MCCB Incomer with metering CTs , multi fuction meter compatible to scada ,Ampermeter with SS,Voltmeter with SS,Indicating Lamps,Control Fuse,wiring etc.complete in all respect. Size:900(W)X2400(H)X1000(D)
400 A MCCB Incomer with Meetering CT's,multi fuction meter compatible to scada ,Ampermeter with SS,Voltmeter with SS,Indicating Lamps,Control Fuse,wiring etc.complete in all respect. Size:900(W)X2400(H)X1000(D)
400 A MCCB Incomer with Meetering CT's,multi fuction meter compatible to scada ,Ampermeter with SS,Voltmeter with SS,Indicating Lamps,Control Fuse,wiring etc.complete in all respect. Size:900(W)X2400(H)X1000(D)
Incommer feeder for transformer 630A/800A,50KA,ACB 3 pole,Al Bus Bars,Digital Multifunction meter compatable to SCADA, metering, Protection CT's,IDMT 3O/C&1 E/F, indicating lamps,control fuse ,wiring etc.complete in all respect of the size appxo 900(D)X.2400(H)X1000(D)
Bus Coupler Feeder, 630/800 A ACB ,50KA,3 Pole without release with Al Bus Bars, Protection CT's ,IDMT 3 O/C & 1 E/F,Indicating Lamps,Control Fses and wiring etc.complete in all respect. (Size : 900(W) x 2400 (H) x 1000 (D)
MCCB up to 100A as outing CT's,Ampermeter with SS,Voltmeter with SS, Indicating Lamps,Control Fuse,wiring etc.complete in all respect. Size:600(W)X2400(H)X1000(D)
MCCB up to 100A as outing CT's,Ampermeter with SS,Voltmeter with SS, Indicating Lamps,Control Fuse,wiring etc.complete in all respect. Size:600(W)X2400(H)X1000(D)
MCCB up to 100A as outing CT's,Ampermeter with SS,Voltmeter with SS, Indicating Lamps,Control Fuse,wiring etc.complete in all respect. Size:600(W)X2400(H)X1000(D)
MCCB up to 100A as outing CT's,Ampermeter with SS,Voltmeter with SS, Indicating Lamps,Control Fuse,wiring etc.complete in all respect. Size:600(W)X2400(H)X1000(D)
MCCB up to 100A as outing CT's,Ampermeter with SS,Voltmeter with SS, Indicating Lamps,Control Fuse,wiring etc.complete in all respect. Size:600(W)X2400(H)X1000(D)
160 A MCCB as outgoing CT's,Ampermeter with SS,Voltmeter with SS, Indicating Lamps, Control Fuse,wiring etc.complete in all respect. Size:600(W)X2400(H)X1000(D)
250 A MCCB as outgoing CT's,Ampermeter with SS,Voltmeter with SS, Indicating Lamps, Control Fuse,wiring etc.complete in all respect. Size:900(W)X2400(H)X1000(D)
SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus.
7.5 KW to 9.3KW
SITC of Local Push Button station fabricated with 16 SWG CRCA sheet, painted with polyster Powder coated finish after chemical treatment with Folliwng items and accessories:- i Shrouded Type push button with 2 NO Contacts element for Start/forward-reverse. ii Lockable Mushroom head type push buuton with 2 NC Contact element. iii 2.5 Sqmm clipon type terminals as requried with 20% spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried.
Supply and erection of Octagonal pole of following length and dimension as per table-3 with base plate on the cement concrete foundation of M-15 /M-20 grade (1:1.5:3) with the help of anchor bolts of grade 6.8 (IS 1367 P III ). The pole shall be made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. The pole shall have a weatherproof flush door and locking arrangements. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning.
Supply, Erection and Fixing of hot dipped galvanised Overhang (60 X 3.25 mm) with cap (250 x 137.9 x 4.05 mm) over the poles
Single arm overhang
P/ F IP-65/ IP-66 protected street light luminaries on bracket / Arm. Fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with high power LEDs . Diffuser / glass cover for ensuring IP-65 protection for lamp and control gear compartment, system lumen output of 100 lum/watt high power LED. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards. System life of 50000 burning hours with 70 % of initial lumens maintained. Fixture shall be in CE compliance. IP-65 protected LED street light luminaries
LED street light fixture 80-90 watt
P & F IP -65 protected integral flood light luminaire suitable for HPSV/ Metal halide lamp comprising of powder coated die cast aluminium housing, electrochemically brightened and anodized stippled aluminium reflector, covered with suitably gasketed heat resistant and toughened glass, porcelain holder, integral control gear box having copper ballast, capacitor, electronic ignitor prewired with pvc insulated copper conductor up to terminal block including making connection testing etc.
1 X 250 Watt
P & F High pressure sodium vapour/ High pressure mercury vapour/ Metal halide/ Halogen lamp as required. HPSV tubular lamp normal output.
Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metre depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of Building and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer.
Heavy Duty AL & CU Lugs, Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Electrical Taps, HT Tap, Danger Plates, First Aid box complete with all standard medical , 4.5 Kg. CO2 type portable fire extinguisher , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per requirements.
11 KV Switchyard Civil work for Transformers Foundations, DP Structure, Chain Link Fencying 1500mm Height, MS Gate , 40mm Gravels, boundary wall, Earthing Chambers, HT/LT cable Trench, Pre-cast covers ect.
Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metre depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of PUMP HOUSE, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of PUMP HOUSE and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer.
HMI Display, Colour, 12" having Ethernet Port, USB Port ect.
Quad-band GSM/GPRS modem with Ethernet bridge/ router/ serial server (RS232/485) interface.
Providing, installation, testing and commissioning of UPS, 3Phase 415 V, 50 Hz with 60 min back up Ni+Cd battery bank.
Providing and laying Stranded/ Flexible Annealed Bare copper conductor ,XLPE/PVC insulated suitably laid up together overall polyester taped Al (inner sheeted GI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steel Armoured overall PVC sheathed (ST-1) overall screened Core Armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009.
1 SQMM, 12 Core
1 SQMM, 24 Core
Providing and laying Stranded/ Flexible Annealed Bare copper conductor ,XLPE/PVC insulated suitably laid up together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wire overall PVC sheathed (ST-1) overall screened Pair Armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009.
1 SQMM, 2 Pair
Providing and laying XLPE/PVC insulated & PVC sheathed Armoured control cables of 1.1 KV grade with copper conductor as per IS 1255 including excavation of 30 CmX75 Cm size trench 25 Cm thick under layer of sand and second class bricks covering, backfilling & compaction.
6C x 1.5 sq.mm
4C x 1.5 sq.mm
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application : Principle : Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4- 20mA / Display: Integral display for programming and Display Reading / IP 66
Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA with HART / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 - 1/2" M (NPT)
Providing, installation, testing and commissioning of Diaphragm Type Pressure Gauges Dial size 150 mm glycerin filled shatterproof glass, Over range protection: 125% of maximum pressure, Material of sensor and other wetted parts: SS type 316, Housing material: Die cast aluminum
Providing, installation, testing and commissioning of Diaphragm type Pressure Switches Sensing Element: Bellows / Diaphragm, Material of sensor and other wetted parts: SS type 316, Housing: Die cast aluminum, Switch type: Microswitch, Repeatability: ± 1% of span, Switch Contacts: 2 NO + 2 NC
Providing, installation, testing and commissioning of Level Switch ( Conductivity) Conductivity Probes: (i) Rigid for lengths of up to 3 meters (ii) Flexible for lengths above 3 meters (Rigid probes preferred), Probe insulation: Teflon, Probe head protection class: IP 65 of IS 13947 Part I, Probe head housing material: Aluminum
Providing, installation, testing and commissioning of Capacitance Level Transmitter for tank /sump level Accuracy: ±1.5 % of span, Probe type: Rod, Probe material: SS type 316, Weather Protection Class: IP 65 of IS 13947 Part I, Output: 4-20 mA DC (Isolated), Material of wetted parts: SS 316, Probe insulation material: Teflon, Stilling pipe: SS type 316 with perforations
Providing, Installation, Testing and Commissioning of CHLORINE ANALYSER for Water Application: Transmitter : Range: 0.05 to 20 ppm, Power Supply 230 VAC, Input: 2 Digital Sensors - one for chlorine and second for pH, Output: 4-20mA HART, IP66/67 Protection / Tx protection cover required / Sensor Range 0-14 pH , able to transmit digital signal to transmitter, calibration data can be transferred to Transmitter , process temp: 65 deg cen/ Sensor range:0.05 to 20 mg/l
Modular RTU for ESR complete with DI, DO, AI and modbus communication ports and power supply 24 VDC or for variable power supply using batteries, rechargeable batteries, solar or 10.8 V DC to 28.8 V DC with VPN modem (3G/4G/5G) ; connection to control center via VPN and Communication protocols as per industry segment, on-board I/Os min. (8 DI, 4 DQ, 2 AI), configuration and diagnostics , web interface, RJ 232/ RJ45/Ethernet port, mobile communications antenna , SIM card slot with adapter Micro SIM card also, GPRS, DIN rail mounting, TCP/IP, Open VPN-Client. Panel Enclosure for RTU Location, wall/floor mounted along with Internal Pre-wiring and related accessories and arrangement of mounting of RTU, Modem having IP-5X outdoor Protection with canopy. Power supply arrangement shall be Solar Based along with Solar Batteries & Solar Invertors suiatble for applicable. RTU application software (multiusers) shall be provided for pump houses, MCC, and Jal Dhara Commond centre at Jaipur Jal Bhawan.
Supply, installation, testing and commissioning of MNRE approved off Grid Solar Panels with 25 years of Linear Generation warranty, Work includes designing of min 150/200/300W solar panel asper site requirement, Solar Battery 24VDC, Inverter, MS fabricated structure, showing arrangement of panel in available space and installation of PV module on frame structure such that minimum height of lower edge of panel shall be 1.0 mtr from ground level to safeguard against damage. The foundation of structure shall be in RCC/ MS Clamps with anchor fastnesr. Mounting structure shall be suitably designed to withstand wind velocity up to 150km/hr. The work shall be executed as per detailed technical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for solar panel and mounting structure and suitable provision shall be included in tender document.
Supply of GSM based data transmitter ( Data Logger) for Bulk Flowmeter (Only for woltman Type BFM - Pulse Output ), Battery Powered -7.4V, battery life 3-5 Years, (1 no Data transmit in a day), 4-20 mA From Pressure Transmitter (If Required) + RS485, Display-16*2 LCD, Encloser-165*120*65 mm, ABS Protection-IP65/67, Operating tempreature -55 Deg. C
For the 1st year of O&M after DLP
For the 2nd year of O&M after DLP
For the 3rd year of O&M after DLP
For the 4th year of O&M after DLP
For the 5th year of O&M after DLP
For the 6th year of O&M after DLP
For the 7th year of O&M after DLP
For the 8th year of O&M after DLP
For the 9th year of O&M after DLP
For the 10th year of O&M after DLP
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.33 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
TD-18.pdf
Tender Documents • 20.09 MB
BOQ_933002.xls
BOQ • 0.88 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .