Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹37.5 L+₹2.0 L (5.66%)Rejected-Finance | L2 | Rejected-Finance rejected being L2 | |
| 3 | L3₹38.6 L+₹3.1 L (8.64%)Rejected-Finance 15 MOULYA NMH LAYOUT 1ST STAGE CHIKKA BANAVARA POST BENGALURU 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L3 | Rejected-Finance rejected being L3 | |
| 4 | L4₹39.0 L+₹3.5 L (9.78%)Rejected-Finance | L4 | Rejected-Finance rejected being L4 | |
| 5 | L5₹39.0 L+₹3.5 L (9.96%)Rejected-Finance NO 422 CHURCH STREET NEW THIPPASANDRA BANGALORE 560075 | BANGALORE | BANGALORE | KARNATAKA | 560075 | L5 | Rejected-Finance rejected being L5 |
Tender Value
Refer Docs
EMD Value
₹66,000
Closing Date
24 Aug 2021, 6:00 pmClosed
GE I R AND D East Bangalore
GE RD East Bangalore 93
REPAIRS RENOVATION OF PSD ENGINE TEST BAY BUILDING AT ADE UNDER GE I RD EAST BANGALORE
2021_MES_437171_1
8131
Open Tender
Civil Works
Item Rate
270 days
GE I R AND D East Bangalore
D a (i), b (i)
9 documents required · 9 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹66,000
Yes
27 Oct 2021
19 Apr 2021
27 Aug 2021
19 Apr 2021
24 Aug 2021
24 May 2021
20 Apr 2021 - 30 Apr 2021
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level) and removal of debries to a distance not exceeding 100 Metre complete all as specified and directed.
Cutting V grooves 15mm X 15mm in existing roof or terrace and cleaning out and filling /making good with epoxy based compound NITOMARTAR PE of FOSROC chemicals as per directions of manufacturer complete.
M&L for PCC 1:2:4 type B0 (Using 12.5mm graded crushed stone aggregate) as in padding concrete for levelling, filleting at junction of wall and slab etc complete all as specified and directed.
M&L for 10mm thick cement screed in CM 1:3 over roof concrete surface and finishing the surface even and smooth without using extra cement with water proofing compound complete all as specified and directed. (WPC shall be measured and paid seperately).
Supply only integral water proofing compound.
M & L for applying bituminous primer T-10/Polymerised primer oil based coat conforming to IS 3384 applied @ 0.3 ltr/sqm and including laying atactic polypropyle polymer (APP) modified membrane pre fabricated five layer 3 mm thick with non-woven polyeser matt central core of 160 gms (minimum) impregnated and coated on both sides with layers of APP modified bitumen and finished with micro-perforated heat fusible polythene film on both surfaces. The weight of membrabe shall not be less than 3.5 kg per sqm and laid over primed surface by using LPG/Butane torch and applying uniform pressure with a roller/wet cloth to ensure to remove entrapped air if any, over lap of the membrane shall be 100 mm which shall be fused uniformly by LPG torch flame/butane torch. The joints shall be sealed with trowel, apply a coat of hot blown bitumen 85/25 grade @ 1.2 kg/sqm over the membrane, finally apply two coat of aluminium paint as protective layer complete all as specified and directed by Engr-in-Charge. Make - Super Thermolay APP PL/MT ( M/s STP Ltd ), Hydostop (M/S Tiki tar industries ( india ltd)Ltd), Moply FP (M/S texsa india ltd, mumbai), Hyperplas polyester (M/S IWL Ltd), M/s Sika India Pvt Ltd ( Sika WP Shield 103/104, M/s Fosroc Chemicals ( Proofex Tochseal 3 PI), Make of Primer - M/S STP Ltd ( Shali Tex Primer), ( WB & OB & Tiki Flash).
M & L apply two coats of aluminium paint on roof complete all as specified and ad directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), rmoving servicable tiles to store and rubbish off the premises
M&L for 50 mm thick PCC 1:3:6 type C-1 using (20 mm graded crushed stone aggregate) as in sub base etc complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4, type B-0 (using 12.5 mm graded crushed stone aggregate) as in floors/paving finishing the surface even and smooth without using extra cement concrete complete all as specified and directed.
M&L Vitrified ceramic tiles of size 10 mm thick light shade, area of each tile exceeding 0.36 sqm and not exceeding 0.42 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed
M&L Vitrified ceramic tiles of size 10 mm thick dark shade, area of each tile exceeding 0.36 sqm and not exceeding 0.42 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed
M&L Vitrified ceramic tiles of size 10 mm thick light shade, area of each tile exceeding 0.36 sqm and not exceeding 0.42 sqm, in skirting. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick screed bed in cement mortar 1:4 complete all as specified and directed
M & L in repairs for 12 mm thick perforated particle board/tiles for insulation and acoustic purposes on wall surfaces, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid complete all as specified and directed
Ditto but except perforated board/tiles
M & L in repairs for 25 mm thick perforated particle board/tiles for insulation and acoustic purposes as in ceiling, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid complete all as specified and directed
Ditto but except perforated board/tiles
Bonded mineral wool blanket slab in repairs made from glass density 24kg/cu m and fixed as per maker's instructions, 25mm thick
Ditto but except material
M & L in repairs, 2nd class hard, wood plain fillets, square, rectangular or triangular in section, wrought, secured with screws, exc 13 but not exc 25 sq cm
Ditto but except wooden filltes complete all as specifed and directed
Demolition of brick work built in cement mortar including all quions, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles.
Material and labour for brick work with sub class 'B' straight or curved on plan exc 6 m radius with old size bricks built in CM 1:4.
Taking down cement or cement lime plaster of any description from walls, including racking out joints hacking for key scrubbing down with water etc , complete all as specified.
M&L 15 mm thick external plaster in CM 1:4 on fair faces of walls , finishing the surfaces even and smooth w/o using extra cement.
M&L 10 mm thick internal plaster in CM 1:6 on other than fair faces of walls , finishing the surfaces even and smooth w/o using extra cement.
M & L for preparation of plastered or unplastered of un decorated surface of walls, chajja, balcony, facia etc by brooming down or steel wire brushing, scrapping down smoke soots, moulds, moss, efflorescent salts, treading oil and greasy spots, and applying two coat of interior dust proof plastic emulsion paint over and including a coat of priming paint over 2 mm wall care putty including sand papering to obtain smooth finish complete all as specified and directed. Make : Royal in Asian or its equivalent in berger/Johnson/Nicholson.
Ditto but on old surfaces after and including complete removal of existing treatment of any type and condition complete all as directed by EIC
M & L two coat of synthetic enamel paint over old painted steel surfaces, over 10cm in width or girth, not otherwise described incl preparation of new or old previously un treated surfaces.
Material and labour for preparation of old wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
Ditto but on old ceiling surfaces complete all as directed
M&L for preparing new plastered surfaces of wall and including two coat of exterior plastic emulsion paint over a coat of primer complete all as specified and directed
Material and labour for preparation of old wall surfaces by complete removal of existing treatment, preparing wall surfaces and applying one coat of exterior plastic emulsion paint like Apex in asian paint or its equivalent complete all as specified and directed
Taking down chowkhats or frame n.exceeding 1.5 Sq. m each with shutter(s) (without taking off shutters from the frame), including removing to store, complete all as specified.
S&F anodised aluminium frame and shutter powder coated for doors and windows, ventilators, partition with one or more rebates including joining cleat,rubber beading for fixing, star lock etc complete.
S/F sheet glass, 4.00 mm thick, ordinary quality and glazing with rubber beadings suitable for aluminium frame work, in square n.exc. 0.5 sqm in each pane.
S/F pin head sheet glass, 4.8 mm thick, ordinary quality and glazing with rubber beadings suitable for aluminium frame work, in square exc. 0.5 sqm in each pane.
S&F fixing black/golden colour solar control film 25 micron reflective type sticked to glass panes as per instruction of manufacturer
S/F in repairs venetian blinds, vertical type, 100 mm slot width of approved fabric and powder coated aluminium top railsetc complete all as specified, including dismantlilng old damaged one completecomplete all as specified and as directed. Note:The colour,design and shade shall be as approved by GE.
Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of any description, area exc 1.5 sqm and n. exc 4 sqm each complete all as specified.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.
Supplying and fixing FACTORY MADE SOLID PANEL PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site, complete as per direction of Engr-in-Charge, manufacturer’s specification & drawing.
Aluminium handles, cast type, 150 mm size anodised complete all as specified.
S & F Aluminium anodised barrel tower bolts 150 mm length of extruded section
S & F Butt hinges,100mm size extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed type B-21
M&L for 75 mm thick PCC 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection finished even & fair complete all as specified and directed (including joint filling with 1:1 ratio bitumen and sand mixed in equal proportion and compacted complete..
M & L 75mm thick Plain cement concrete type B-2, 1:2:4 (using 40mm graded stone aggregate) as in hardstandings etc.,
Plain Cement concrete 1:2:4 , type B-1 , (using 20mm graded crushed stone aggregate), in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates and similar works including weathering, slightly rouinded for chamfered angles and throating and necessary form work, complete all as specified and as directed by Engr-in -Charge.
Taking down PVC air, vent, soil and rain water pipes of dia, 150 mm fixed to wall or in trenches etc,.
S & F UPVC (SCH-40) pipes 150 mm bore fixed as in vertical stacks including joints/fittings fixed to walls. Note : "Making proper leak proof joint with valley gutter to the newly fixing pipe with funnel type made up galvalume sheet material as same as valley gutter, the same will be measured under item 2 above complete"
S & F 150 mm bore UPVC bends any radius
M & L one coat of aluminium paint over existing painted surfaces including preparation complete.
M & L one coat of synthetic enamel paint over surfaces of any description of old painted wood surfaces over 10 cm width or girth including preparation complete
Material and Labour for providing the sealant (pouring grade) in the existing 10mm wide & 40mm deep groove/joint after preparation of joint as per manufacture instructions along with application of primer as per manufacture instructions. (a) Thioflex 600 shall be of M/s FOSROC/ MASTERFLEX TM 700i of BASF or equivalent in CIPY. (b) Primer 7E shall be M/s FOSROC or equivalent in BASF/CIPY. Note for item No 01 & 02 :- Application of Epoxy and sealant shall be carried out by authorised applicator of manufacture.
M & L in repairs anodised aluminium snap grid frame work for false ceiling all as specified
M & L in repairs 12 mm th prelaminatd particle board as in ceiling board of 600 x 600 mm sizes, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work
Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified
Taking down carefully the existing aluminium point wiring of any size and capacity and type by disconnecting from the either terminals complete including fittings and fixtures such as switches, sockets,ceiling rose, regulators and light fittings any type etc by unscrewing and taken away from site complete. Note :cost of unserviceable materials will be charged from the contractor against schedule of credit.
M & L for point wiring with 1.5 sqmm (Nominal Area)PVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade, with non metalic rigid PVC medium duty conduit with accessories such as junction boxes, bends, tees etc. of suitable size including modular terminal box & Cover plate for mounting of switches, sockets fan regulators etc and including continuous earth wire PVC insulated 1.50 Sq mm copper stranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for the following :-
(a) For one light point controlled by one switch
(b) For one fan point controlled by one switch through regulator
(c) For one Exhaust point controlled by one switch through regulator
(d) For one three pin socket out let 5 amps on independent board complete.
All as per item No 59 here in before but with cable 2.50 sqmm (nominal area) multi stranded copper wire unsheathed for one 3 pin socket out let 15 amps on independent board including continuous eartth wire PVC insulated 1.50 sqmm copper stranded conductor, connecting to common earth and earth dolly complete.
Supply and fixing of Modular switch piano 6 A,230 V
Supply and fixing of Modular switch piano 16 A,230 V
Supply and fixing of Modular fan regulator step type 100 w,230 V
Supply and fixing of Modular socket piano 6 A,230 V
Supply and fixing of Modular socket piano 16 A,230 V
Supply and fixing ceiling rose surface type 3 terminals 65x20mm
M & L for sub main wiring with single core PVC insulated unsheathed , 1100 Volts grade, copper cable 2x10.0 sq. mm+ 1x6.0 sq. mm stranded conductor and drawing through and including rigid PVC non metalic surface conduit of suitable size with conduit accessories such as junction boxes, bends, tees etc. including continus earth wire PVC insulated unsheathed 1100 volts grade, One run of copper cable 6.00 sqmm copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring Note :-(i) One run of PVC conduit two runs of cable and one run of earth wire shall be measured and paid as one unit.
M & L for sub main wiring with single core PVC insulated unsheathed , 1100 Volts grade, copper cable 2x6.0 sq. mm +1x4.0 sq. mm stranded conductor and drawing through and including rigid PVC non metalic surface conduit of suitable size with conduit accessories such as junction boxes, bends, tees etc. including continus earth wire PVC insulated unsheathed 1100 volts grade,One run of 4.00 sqmm cable copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring Note :-(i) One run of PVC conduit two runs of 2 X 6.00 sqmm cable and one run of 4.00 sqmm of earth wire shall be measured and paid as one unit.
M & L for sub main wiring with single core PVC insulated unsheathed , 1100 Volts grade, copper cable 2 X 4.00 sq. mm + 1 x 2.5 sq. mm stranded conductor and drawing through and including rigid PVC non metalic surface conduit of suitable size with conduit accessories such as junction boxes, bends, tees etc. including continus earth wire PVC insulated unsheathed 1100 volts grade,One run of 4.00 sqmm cable copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring Note :-(i) One run of PVC conduit two runs of 2 X 4.00 sqmm cable and one run of 2.50 sqmm of earth wire shall be measured and paid as one unit.
M & L for sub main wiring with single core PVC insulated unsheathed , 1100 Volts grade, copper cable 2x2.5 sq. mm + 1x1.5 sq. mm stranded conductor and drawing through and including rigid PVC non metalic surface conduit of suitable size with conduit accessories such as junction boxes, bends, tees etc. including continus earth wire PVC insulated unsheathed 1100 volts grade,One run of 1.50 sqmm cable copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring Note :-(i) One run of PVC conduit two runs of 2 X 2.50 sqmm cable and one run of 1.50 sqmm of earth wire shall be measured and paid as one unit.
Supply and Fixing of Distribution Board, TPN 8 way, 240V, double door type. Make- C&S/CG/Legrand/Indoasian/simens
Supply and Fixing of Distribution Board, SPN 8 way, 240V, double door type. Make- C&S/CG/Legrand/Indoasian/simens
Supply and fixing of MCB, SP, 240V, upto 40 Amps 10KA rupturing capacity. Make-Indo Asian/C&SLegrand/Havells/simens
Supply and fixing of MCB, SPN, 240V, upto 40 Amps 10KA rupturing capacity. Make-Indo Asian/C&SLegrand/Havells/simens
Supply and fixing of MCB, TPN, 240V, upto 63 Amps 10KA rupturing capacity. Make-Indo Asian/C&SLegrand/Havells/simens
Supply and fixing of LED light 2 X 2 Recessed/Surface mounting 36 watts, Model : POLARIS III, CAT REF : LCTLSN - 36 CDL
M & L for earthing complete with copper earth plate of size 600 x 600 x 3.15 mm buried directly and preferably vertically in ground with top edge not less than 1.25M below ground level connected with copper earth strip of 20 x 3 mm connected to the earthing test point all as specified and all as directed by Engineer incharge including testing and submission of test reports. Note : The rates quoted are inclusive of copper earth strip upto the standard length as specified in the SSR part -1. However additional length will be measured and paid seperately in respective item.
Supply and fixing of LED light 36 watts, slim down light durable LED batten with decorative end caps, TRIM LINEA, CAT REF LDL - 36 CDL, Make : CG/HAVELLS/PHILPS
Supply and fixing of Building security LED light 30 watts Model : FREEDOM + CAT NO : LSTS - 30 - CDL Make : CG/HAVELLS/PHILIPS
Supply and fix new generation post top 40 watts 360 degree energysaving environmental friendly long life aesthetically designed with good indirect symmetrical light distribution of cap, cast aluminium landscape luminarie with high power as light source IP65 protection all prewired fixed on the existing L GI Pipe inclduing testing complete all as specified and as directed. Make : CG, Model : MAPLE, Cat Part NO LPTO-40/CDL Make : CG/ HAVELLS/WIPRO/BAJAJ
Supply and fixing of 70 Watts Circullar Highbay with tappered in design along with IP 66 protection, Make : CG, Model : SURROUND II, CAT REF : LHB11-70-CDL/60 Make : CG/HAVELLS/PHILIPS
Supply and fixing of Sheet metal Enclosure Including provision of MCCB 100 Amps and properly grouting on walls.
Supply and fixing of DOL starter 12.50 HP 3PHASE, 415 Volts
Supply & fixing of SPN enclosure for AC, Including provision of 1 no MCB 20 Amp
(a) MCCB 400 Amps, 4 P, 50 KA-01 No as Incomer
(b) MCCB 100 Amps, 3 P, 25 KA, 04 Nos as Outgoing
(b) MCB 32 Amps, TPN, 16 KA-04 Nos as Outgoing
(g) Digital Ammeter(01 No)
(h) Digital Voltmeter (01 No)
(j) RYB Indication lamp (01 Set)
Supply and fixing of Copper strip 20 x 3 mm
M & L for sub main wiring with single core PVC insulated unsheathed , 1100 Volts grade, copper cable 4 x 10.0 sq. mm+ 2 x 6.0 sq. mm stranded conductor and drawing through and including rigid PVC non metalic surface conduit of suitable size with conduit accessories such as junction boxes, bends, tees etc. including continus earth wire PVC insulated unsheathed 1100 volts grade, One run of copper cable 6.00 sqmm copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring Note :-(i) One run of PVC conduit Four runs of cable and Two runs of earth wire shall be measured and paid as one unit.
Supply and laying of G I wire 4.00 mm dia for connecting for earthing
SAI CONSTRUCTIONS
Moulya Builders
Kaveri Enterprise
Siddivinayaka Constructions
S CHANDRASHEKAR (SREE BUILDERS)
Lucky Enterprises
Meghana and Gowda Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .