Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹21.0 L+₹5,535.80 (0.26%)Rejected-AOC | L2 | Rejected-AOC Rejected due to not being L1 | |
| 3 | L3₹22.1 L+₹1.2 L (5.53%)Rejected-AOC 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L3 | Rejected-AOC Rejected due to not being L1 | |
| 4 | L4₹24.9 L+₹3.9 L (18.7%)Rejected-AOC | L4 | Rejected-AOC Rejected due to not being L1 |
Tender Value
Refer Docs
EMD Value
₹52,800
Closing Date
28 Dec 2022, 6:00 pmClosed
GE NORTH UDHAMPUR
GE NORTH UDHAMPUR
WORKS GE U(N) 61 2022 23 PROVISION OF TOILET BLOCK CONSISTING OF 2 WC 01 URINAL WASH BASIN AND 2 BATHING CUBICAL NEAR B NO P46 INCLUDING SOME REVENUE AND MINOR WORKS AT DIFFERENT LOCATIONS UNDER GE(N) UDHAMPUR
2022_MES_566249_1
GE/U(N)/61/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE NORTH UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NORTH UDHAMPUR
₹52,800
Yes
9 Jan 2023
30 Nov 2022
30 Dec 2022
30 Nov 2022
28 Dec 2022
14 Dec 2022
Amount
M&L for demolition of brick work or stone masonry built in Cement Mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed by Engr in charge.
M&L for demolition of unreinforced cement concrete in ground floors and paving n.exc 15cm thickness (below or above ground level) complete all as specified and directed by Engr in charge.
M&L for demolition of cement concrete reinforced of any description and in any position not otherwise specifically provided for cement concrete complete all as specified and directed by Engr in charge.
M&L for surface dressing n exc 15cm deep complete all as specified and directed by Engr in charge.
M&L for surface excavation not exc 30cm deep and averging 15cm deep and getting out in any type of soil complete all as specified and directed by Engr in charge.
M&L for excavating in trenches in hard/dense soil, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out complete all as specified and directed by Engr in charge.
M&L for removig excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed by Engr in charge.
M&L for removing excavated material exc 250m but n.exc 500m and depositibg where directed complete all as specified and directed by Engr in charge.
M&L for returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed by Engr in charge.
M&L for earth filling under floors including watering and consolidation complete (earth shall be used from excavation free from vegetation, pebbelse/foreign materials complete all as specified and directed by Engr in charge.
M&L for hard core of gauge exc 63mm, deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface complete all as specified and directed by Engr in charge.
M&L for reinforced cement concrete M-25 design mix in foundation including rafts, footings, foundation beams, plinth beams and mass concrete complete all as specified and directed by Engr in charge.
M&L for reinforced cement concrete M-25 design mix in columns, pillars, piers, post and struts complete all as specified and directed by Engr in charge.
M&L for reinforced cement concrete M-25 design mix in beams, cantilevers, lintel complete all as specified and directed by Engr in charge.
M & L reinforced cement concrete type B1 1:2:4 (using 20 mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engr in charge.
M&L for reinforced cement concrete 1:2:4 type B1 (20mm graded aggregate) over openings including formwork complete all as specified and directed by Engr in charge.
M&L for reinforced cement concrete M-25(Design mix) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like including 15 mm th plastering with water proofing compound as directed laid/made to slope as in RCC roof surfaces complete all as per specified & directed by Engr-In-Charge.
M&L for providing precast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in Kerb stones and in similar works bedded and jointed in CM 1:6 incl necessary exc if necessary complete all as specified and directed by Engr in charge.
M&L for plain cement concrete type C1 1:3:6 (using 20mm down graded stone aggregate) as in kerbs including necessary form work complete all as specified and directed by Engr in charge.
M&L for plain cement concrete type C0 1:3:6 (using 12.5mm down graded stone aggregate) in benching, coping and the like including weathering slightly rounded or chamfered angles as sirected including form work and finishing all exposed complete all as specified and directed by Engr in charge.
M&L for plain cement concrete type 1:4:8 type D2 cement concrete in foundations filling nd mass concrete complete all as specified and directed by Engr in charge.
M&L for plain cement concrete type M-10 (nominal mix) as in surface channel and drains complete all as specified and directed by Engr in charge.
M&L for precast cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in cover slabs ( for manholes etc). and similar articles with plain faces, set in cement mortar 1:6, complete all as specified and directed by Engr-in-Charge. .
M&L for brick work with old size bricks having crushing strength not less than 75Kg/ Sqm, straight or curved on plan exceeding 6m mean radius with old size bricks built in cement mortar 1:4 complete all as specified and directed by Engr in charge.
M&L for brick work with CM (1:6) class 'B' bricks straight or curved on plan exc 6m mean radius complete all as specified and directed by Engr in charge.
M&L for 75mm thick fire brick flooring in fire places, flues etc (other than in chimney shafts), set jointed and pointed in fireclay complete all as specified and directed by Engr in charge.
M&L for brick work using old size bricks, straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4, complete all as specified and directed by Engr in charge.
M&L for use and waste of formwormk to side of concrete foundation, footings, bases of columns, rafts and raft beams, side and soffit of foundation and plinth beams flat, for rough finished surfaces of concrete complete all as specified and directed by Engr in charge.
M&L for use and waste of formwork to sides of pillars, columns and stanchions, square or rectngular, for rough finished surfaces of concrete complete all as specified and directed by Engr in charge.
M&L for use and waste of formwork to sides and soffit of floor and roof beams, beam haunchings, girders, shelves etc flat for rough finished surfaces of concrete complete all as specified and directed by Engr in charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as per specified & directed by Engr-In-Charge.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as per specified & directed by Engr-In-Charge.
M&L for mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending pirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less then 0.9mm dia secuing with clips complete all as specified and directed by Engr in charge.
M&L for TMT steel bars 6 to 8mm dia and over, cut to length, bent to shape required, including, hooking and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engr in charge.
M&L for TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including, hooking and binding with and including mild steel wire (annealed) not less than 0.9mm dia. complete all as specified and directed by Engr in charge.
S&F FI hold fasts 25x6x150 long (06 Nos in equal distance) rivetted to iron & embedded in masonry to support 35x35x6 L I ring complete all as specified and directed by Engr in charge.
S&F 35x35x6 L I ring to support the grating complete all as specified and directed by Engr in charge.
S&F 16mm dia rounded bar grating flattered ends rivetted to LI ring complete all as specified and directed by Engr in charge.
S&F FI hold fasts 25x6x150 long (04 Nos) in feed opening door complete all as specified and directed by Engr in charge.
S&F 40x40x6 LI in feed opening door complete all as specified and directed by Engr in charge.
S&f 6mm thick MS plate shutter in feed opening door complete all as specified and directed by Engr in charge.
S&F 35x35x6 LI ring to support the GI Flute sheet complete all as specified and directed by Engr in charge.
S&F X PM to prevent loose particles. Expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wie not less han 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to steel member complete all as specified and directed by Engr in charge.
M&L for 75mm thick Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base of flooring etc, complete all as specified and directed by Engr in charge.
M&L for 50mm thick plain cement concrete type C-1 1:3:6(Using 20mm graded crushed stone aggregates) as in plinth protection finished fair and even without using extra cement complete all as specified and directed by Engr in charge. Note : The plinth protection shall be laid in panels and length of the each panel shall not be more than 2.00 metre all as directed. 6mm joints filled with 85/25 grade bitumen and sand (1:3 ratio) shall be provided. No deduction for joints shall be made while making payment against the above item.
M&L for cement concrete 50mm thick type B-1, 1:2:4 (20mm graded aggregate) as in sub base complete all as specified and directed by Engr in charge.
M&L for 40 mm th PCC 1:2:4 type B0 using 12.5 mm graded stone agg as in damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed by Engr in charge.
M&L for 75mm thick cement concrete type B-2, 1:2:4 (40mm graded aggregate) in floor complete all as specified and directed by Engr in charge.
Supply only integral water proofing compound
M&L for machine pressed precast interlocking paver blocks any shape and size with grey cement abd pigment confirming to IS 15658-2006 of 60mm thickness (M-35 Grade) including 25mm thick sand cushioning as required at site complete all as specified and directed by Engr in charge.
M&L for cheaquered cement concrete tile 20cm x 20cm x 25mm thick set jointed and pointed with mixture of white and grey cement in equal proportion and no pigment in floors complete all as specified and directed by Engr in charge.
M&L for non skid coloured glazed ceramic tiles area of each tile exc. .11 sqm but n.exc. .18 sqm 7mm to 8mm mm thick as in floor finishes set and jointed in neat cement slurry and pointed in white or coloured cement to match ,including bedding layaers of CM 1:4 (20mm thick) complete all as specified and directed by Engr in charge.
M&L for glazed ceramic tiles (coloured) on vertical surfaces 450x300x6 to 7 mm thick set and jointed in neat cement slurry and pointed in coloured cement to match including rendering 10mm thick cement plaster on fair faceof brick work in cement mortar 1:4 as in backing coat for wall tile complete all as specified and directed by Engr in charge.
S&F butt hinges 50mm long 02 Nos 25x6 mm in size in feed opeing door complete all as specified and directed by Engr in charge.
S&F 8mm thick handle (150mm long) rivetted to MS plate shutter in feed opening door complete all as specified and directed by Engr in charge.
M&L for 40mm thick cement concrete type B1, 1:2:4 (20mm graded aggregate) with checkered finish complete all as specified and directed by Engr in charge.
M&L for 70mm avg. thick PCC benching at the junction of flue pipe & block masonry. Cement concrete 1:2:4 type B0, (12.5mm graded aggregate) complete all as specified and directed by Engr in charge.
S&F 250mm dia flue pipes of mild steel sheet, black, in suitable lengths as approved by the Engr In charge fixed to walls complete all as specified and directed by Engr in charge.
S&F 50x6 mm FI rivetted to GI sheet flue & cowel cover complete all as specified and directed by Engr in charge.
S&F 250mm dia cowl cover complete all as specified and directed by Engr in charge.
M&L for 15mm thick plaster work in CM (1:6),on fair faces of concrete surfaces, including rendering finished even and smooth (without using extra lime or cement) complete all as specified and directed by Engr in charge.
M&L for rendering 15mm thick on fair faces brick surfaces in cement mortar 1:4 even and smooth without using extra cement complete all as specified and directed by Engr in charge.
M&L for rendering 5 mm thick plaster on ceiling surfaces including three coat of white wash over newly plastered surfaces complete all as specified and directed by Engr in charge.
M&L for extra for forming fair finished drain or drain channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred stopped ends etc complete all as specified and directed by Engr in charge.
M&L for two coat of colour wash over a priming coat of white wash including preparation of plastered surface complete all as specified and directed by Engr in charge.
M&L for 50 mm avg thick PCC 1:2:4 type B0, (12.5mm graded aggregate) on cill of feed opening door complete all as specified and directed by Engr in charge.
Add or deduct extra 25 mm girth complete all as specified and directed by Engr in charge.
S&F wooden wall cabinate as for as following requirement complete all as per specified & directed by Engr-In-Charge. -: (a) Wooden wall unit (7 x 30" with six shelves of 340x90mm up right. -13 No (b) Wooden wall unit (7 x 34" with six shelves of 340x90mm up right. -01 No (c) Wooden wall unit (7 x 24" with six shelves of 340x90mm up right. -01 No (d) Wash basin table of length 72"x24"x36" height with top korean top -01 No (e) Extra upright (extra pillar) -04 No
M&L for taking up or down steel tubing and connections, including cleaing for refixing or removal to store 15mm dia complete all as specified and directed by Engr in charge.
M&L for taking up or down steel tubing and connections, including cleaing for refixing or removal to store 20mm dia complete all as specified and directed by Engr in charge.
M&L for taking up or down steel tubing and connections, including cleaing for refixing or removal to store 40mm dia complete all as specified and directed by Engr in charge.
S&F steel water tubing grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 15mm borecomplete all as specified and directed by Engr in charge.
S&F steel water tubing grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 20mm bore complete all as specified and directed by Engr in charge.
S&F steel water tubing grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 40mm borecomplete all as specified and directed by Engr in charge.
S&F vitreous china wash down water closet pan `P` or `S` trap ( pedestal pattern ) white including fixing bolts,including connection to drain pipe ( or out going pipe) and to flushing pipe,Jet spray and PVC seat cover antisyphonage pipe etc complete all as specified and directed by Engr in charge.
Supply and fixing PVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including PVC connection and 32mm dia PVC long bend for squat pattern etc , set with concrete and making good to floor complete all as specified and directed by Engr in charge.
S & F grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40 gms) complete all as specified and directed by Engr in charge.
M&L for concrete bed to drain pipes of bore 150mm including packing under,and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate including necessary shuttering and supports, complete all as specified and as directed. Note:- (i) Thickness of bed belew barrel of pipe -10 cm. (ii) Width of bed :- outer dia of pipe plus 30 cm.
M&L for salt glazed stone ware drain pipes of internal diameter 150 mm, grade 'A' quality, laid in trenches and jointed in cement, complete all as specified and directed by Engr in charge.
Supply and fixing cast iron soil, waste and vent pipe 100mm dia bore (ISI Marked) sand cast pipes, in any length with or without ears, in cement joint, laid in trenches or fixed in walls etc, complete all as specified and directed by Engr in charge.
Supply and fixing cast iron soil, waste and vent pipe 75mm dia bore (ISI Marked) sand cast pipes, in any length with or without ears, in cement joint, laid in trenches or fixed in walls etc, complete all as specified and directed by Engr in charge.
Supply and fixing cast iron soil, waste and vent pipe 50mm dia bore (ISI Marked) sand cast pipes, in any length with or without ears, in cement joint, laid in trenches or fixed in walls etc, complete all as specified and directed by Engr in charge.
M&L for CI floor trap 75mm dia with CI grating including jointing to waste pipe in run lead complete and making good the disturbed surface to match the existing surface, complete all as specified and directed by Engr in charge.
Supply and fixing CI bend/Tee suitable for 100mm bore pipe (any radius), diminishing pieces or tapers ( larger bore measured ) wit oval acess door, fixed as in repairs complete all as specified and directed by Engr in charge.
M&L for cast iron oval access door, fixed in repair for 100/75mm bore of pipe, complete all as specified and directed by Engr in charge.
S & F sheet glass, ordinary quality and glazing with oil putty or fixed in alu beading, in square exc 0.5 sq.m in each pane complete all as specified and directed by Engr in charge.
S & F solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing
S & F factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile:), with 2,4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm Plan colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing
S & F but hinges, extruded aluminium alloy, with galvanised mild steel hinge pin, anodised and fixed, type B-21, 100 mm long complete all as specified and directed by Engr in charge.
S & F Extruded aluminium ally handles, fabricated type., anodised complete all as specified and directed by Engr in charge.
S & F Aluminium, anodised, barrel tower bolts of extruded section and fixed, 125 mm complete all as specified and directed by Engr in charge.
S&F in repair Viterous china wash basin, white flat back size 550 x 400mm incl waste couping CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia & CP getting with holes complete all as specified and directed by Engr-in-Chare.
S & F aluminium hooks (single) 50mm to 60mm complete all as specified and directed by Engr in charge.
M&L for towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90 gms) complete all as specified and directed by Engr in charge.
S & F urinals half stall including spreader and PVC connection and waste pipe complete with all accessories all as specified and dericted by Engr in Charge.
Supply and fixing PVC (SWR) gully trap of size 150 x 110 mm, setting and jointing with solvent cement complete all as specified and directed by Engr in charge.
M&L for two coat of Oil bound distemper including a coat of primer including preparation of newly plastered surfaces of wall complete all as specified and directed by Engr in charge.
M&L for two coat of cement base paint including preparation of newly plastered surfaces of wall complete all as specified and directed by Engr in charge.
S&F stop cock fancy type Cromium plate for 15mm bore complete all as approved complete all as specified and directed by Engr in charge.
S&F stop cock fancy type Cromium plate concealed for 15mm bore complete all as approved complete all as specified and directed by Engr in charge.
S&F 15mm Bib taps, cast copper alloy, fency type chromium plated, with crtuch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engr in charge.
S&F PVC (SWR) floor trap plain with grating including jointing with solvent 75mm complete all as specified and directed by Engr in charge.
S&F chromium plated shower rose fancy type 125mm dia, swivel type suitble for 15mm bore fitting complete all as specified and directed by Engr in charge.
S&F rotational moulded polyethlene water storage tanks three layered white in colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I,capacity of water tank 500 Ltr complete all as specified and directed by Engr in charge.
S&F ball brass valves 20mm , high pressure, with polyethene float & fly-nut complete, screwed for iron pipe or brass ferrule & fixed complete all as specified and directed by Engr in charge.
S&F stop valves, 20mm cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions & fixed complete all as specified and directed by Engr in charge.
M&L for cutting into exising manholes for connecting new drains (internal dia of pipe n.exc 200 mm), making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section ) in cement concrete 1:2:4 type B-1(using 20mm graded crushed stone aggregate) smooth finished, and reforming benching complete all as specified and directed by Engr in charge.
M&L for soakage well 1.2m dia x 2.4m deep in ordinary doil, foundation in PCC 1:3:6, wells of honey cobed and solid in M-25concrete, including interception chamber screen chamber Brick work in CM, RCC cover slab in M-25/RR masonry/filling with brick bats, complete all as specified and directed by Engr in charge.
Excavation over areas exc 1.5m deep and n.exc 3.0m in depth and getting out in any type of soil complete all as specified.
M&L for point wiring with PVC insulated unsheathed, FRLS 1100 volts grade stranded copper conductor cable single core 1.5 Sqmm for one light / fan point/bell point controlled by one way switch, and wire to be drawn in and including concealed conduit of dia not less tham 25mm complete with all accessories including MS sheet metal 1.2 mm thick switch board of suitable size be fixed flush wall , with 3 mm thick ebonite sheet cover and necessary screws, cap washers etc. or to be fixed on wall respectively as directed by EIC and providing earth continuity wire using PVC insulated, un sheathed single core stranded copper conductor FRLS cable of size 1.5 Sqmm.(Cutting chases for counduits shall be measured and paid separately)
All as per item No 110 above but for 3 pins socket outlet 15 Amps independent with 2.5 sqmm incl continous earthing with multistandred copper conductor PVC insulated unsheathed size 2.5 Sqmm complete all as specified and directed.
S&F Switch Piano flush type single pole 5 Amps One way, all as specified and directed by Engineer- in - Charge.
S&F Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body complete all as specified and directed by Engineer - in - Charge.
Supply and fixing Exhaust fans steel body,AC ingle phasee 230 volts of size 300 mm sweep with blades and frame and louver complete all as specified and directed
S&F Slim linear LED lighting fixture 20 watt LED batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete including taking down old US tube light fitting 1x36 Wall as per the direction of Engr-in-Charge. Make -Make model of Havells cat No LHEXCEP7UN1W020 or equilent to CG/ syska CAT No SSK ALB 20W
S&F in replacement E-Lite LED Curve lighting fixture for mirror 10/12 watt LED batten,2' long with full base of extruded Aluminium body environmental friendly, energy efficient ready to use pack with isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete all as per the direction of Engr-in-Charge. Make -Havells as per ordering code LHEXBYPNIN1W010 / wipro cat No D531065/ Syska cat No SSK-T5-12w .
M&L for submain wiring with 2X6.0 SQMM+1X6.0SQMM Earth Wire single core PVC insulated FRSL sheathed cooper cable connecting to common earth dolly in and including heavy duty PVC Concealed Conduit as per site requirement including taking down old us submain wiringand direction by EIC, all accessories complete all as specified and directed by Engr in charge.
S & F single pole and neutral sheet steel powder coated Distribution board for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 8 ways. complete all as specified and directed by Engr in charge.
S&F 'C' series SPN MCB 40 to 63Amps 240V ,50Hz,10kA lighting and other domestic loads incl all termnials, fitting etc. complete all as specified and directed by Engr in charge.
S&F 'C' series SP MCB 06 to 32 Amps 240V ,50Hz,10kA suitable for lighting and other domestic loads incl all termnials, fitting etc. complete all as specified and directed by Engr in charge.
M&L Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-5 of MES Part-1 fixed in replacement including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC Pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of Earthing. Note : (a) On testing after completion of earthing, if the desired earth resistnace is not obtained, the earthing will be done by the contractor at his own risk and cost to the entire satisfaction ot the engineer incharge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
M/S PARDEEP KUMAR
KUMAR CONSTRUCTION CO
JOGINDER SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .