Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC HARIPUSHPA APARTMENT BUILDING NO E 1 FLAT NO 01 REST CAMP ROAD DEOLALI CAMP 422 401 | DEOLALI CAMP | NASHIK | MAHARASHTRA | 422401 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹35.7 L+₹1.7 L (5.07%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹36.6 L+₹2.6 L (7.68%)Rejected-Finance HIMACHAL BUILDING SHOP NO 10 CD BARFYWALA ROAD JUHU LANE ANDHERI W MUMBAI 400058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | L3 | Rejected-Finance BEING L3 |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
8 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF THANE
Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
SR,REPL TO CERTAIN HANGER and OTM BUILDINGS OF MTS AT SITE P AF STN AND ADDN ,ALTR TO EXISTING FIRE FRIGHTENING FACILITIES INCLUDING SWTs, FIRE SHEDS AND PROV OF OVERHEAD POINT WITH 24X7 WATER FILLING FACILITY AT SITE P AND R AFS UNDER GE AF THANE
2023_MES_602556_1
8277/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹82,000
Yes
29 Aug 2023
10 Jun 2023
10 Jul 2023
10 Jun 2023
8 Jul 2023
26 Jun 2023
10 Jun 2023 - 26 Jun 2023
Amount
Taking down the steel rolling shutter gear operated rolling shutter n-exc 30 sqm area including adjustment of gear worms assenbely complete each including hood cover and cleaning the sides of shutter suspension and guide shannelks and greasing all the moving parts of rolling shutter shaft and replacement of bolts and nuts as required for smooth functioninig of shutters and refixing the same including hood cover ,complete all as specified & as directed by Engr-in-Charge.
S & F in repair in MS hood cover made out of mild steel sheets 1.00mm thick including bending the steel sheets to required shape and fixing the sheet to the rolling shutters bracket plate including one coat of red oxide primer and two coat of aluminium paints ,complete all as specified & as directed by Engr-in-Charge.
Taking down the steel rolling shutter push and pull rolling shutter n-exc 12 sqm area including adjustment of gear worms assembely complete each including hood cover ,complete all as specified & as directed by Engr-in-Charge.
S&F in repairs of roller ball bearing ISI marked for 40mm dia pipe shaft , complete all as specified and as directed by Engr-in-charge.
S&F in repair Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type thickness of latch 1.00 mm ,complete all as specified & as directed by Engr-in-Charge.
S & F ,in repairs, MS gear assembly complete including connecting and fixing the gear box to wall with two nos hexagonal bolts 10mm dia 10 cm long complete and grouting the bolt in cement mortar in 1:3 ,complete all as specified & as directed by Engr-in-Charge.
S&F,in repair,mild steel helical wire spring of gauge 1of approved make and 12" long ,complete all as specified & as directed by Engr-in-Charge.
Dismantling cast iron work of any description as in door / window frame and vertical poles , complete all as specified and as directed by Engr-in-charge.
S&F in repair Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates FE410- W (Gde E 250) Quality A, complete all as specified and as directed by Engr-in-charge
S&F in repair Steel work in as Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment (FE410- W (Gde E 250) Quality A complete all as specified and as directed by Engr-in-charge.
M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing ,complete all as specified & as directed by Engr-in-Charge.
Material and labour for powder coated anodised aluminium frame for doors, windows, ventilation and partition walls with one or more rebates including joining cleat for fixing etc. fixed to wall, floor,ceiling complete all as specified and directed (Glass and other filling material in panels shall be measured and paid for separately) ,complete all as specified & as directed by Engr-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden, metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones, complete all as specified and as directed by Engineer-in-charge.
S&F in repair sheet glass ordinary quality 4.00mm thick and glazing with oil putty in squares n.exc 0.5 sqm in each pane,complete all as specified & as directed by Engr-in-Charge.
Dismantling Asbestos cement corrugated /semi corrugated etc sheet in roof covering ,complete all as specified & as directed by Engr-in-Charge.
M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws ,complete all as specified & as directed by Engr-in-Charge.
S&F in repair Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws ,complete all as specified & as directed by Engr-in-Charge.
Taking down cement plaster of any description on brick walls including raking out joints, hacking for key, scrubbing down with water ,complete all as specified & as directed by Engr-in-Charge.
Demolition of Brickwork or stone/boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles ,complete all as specified and as directed by Engr-in-charge.
Rendering 15mm thick (10 mm thick as backing coat in CM 1:6 and finishing coat of 5 mm thick in CM (1:4) ) on fair faces of brickwork or concrete surfaces or for protection of PU coating, finished even and smooth (without using extra cement) using water proofing compound (water proofing compound shall be measured and paid seperately under relevent item of Sch A) complete all as specified and directed.
Rendering 10mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces, finished even and smooth (without using extra lime or cement) ,complete all as specified & as directed by Engr-in-Charge.
M&L for Providing, cement concrete type C1 1:3:6 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angle,complete all as specified & as directed by Engr-in-Charge.
M&L for preparation of newly plastered surface of ceiling and applying two coat of white wash over a coat of chalk whitening on ceiling ,complete all as specified & as directed by Engr-in-Charge.
M&L for preparation of newly plastered surface of wall and applying two coat of white wash over a coat of chalk whitening on walls ,complete all as specified & as directed by Engr-in-Charge.
M & L for preparaing plastered or unplastered surfaces of old walls including Washing, rubbing down and stopping of old painted surfaces and applying two coat of white wash on walls ,complete all as specified & as directed by Engr-in-Charge.
M&L for preparation of surface plastered or unplastered old surface of wall and applying Finishing walls with Acrylic Smooth exterior paint of required shade : (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), as in camoflouge pattern all as specified and as directed by Engineer-in-charge.
M&L for preparation of New steel surfaces of any description over 10 cm in width or girth not otherwise described and apply two coats of EPU weather proof exterier coating synthetic paint over a coat of red oxide primer ,complete all as specified & as directed by Engr-in-Charge.
M&L for preparation of Old steel surfaces of any description over 10 cm in width or girth not otherwise described and apply two coats of EPU weather proof exterier coating synthetic paint over a coat of red oxide primer ,complete all as specified & as directed by Engr-in-Charge.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) floors, aprons etc ,complete all as specified & as directed by Engr-in-Charge.
M&L for M-20 PCC (1:2:4) nominal mix with 20 mm graded coarse aggregate as per relevent IS code for floors, aprons etc,complete all as specified & as directed by Engr-in-Charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) ,complete all as specified & as directed by Engr-in-Charge.
S&F pipes 100 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls / vertical surfaces for rain water collection and conveyance ,complete all as specified & as directed by Engr-in-Charge.
S&F pipes 140 mm dia PVC (SWR) half round pipes as eaves gutters in any length with rubber ring joints fixed to GI sheets for rain water collection and conveyance ,complete all as specified & as directed by Engr-in-Charge.
S&F pipes 140 mm dia PVC (SWR) 90 degree Elbow with outlet fixed to GI sheets for rain water collection and conveyance ,complete all as specified & as directed by Engr-in-Charge.
S&F pipes 140 mm dia PVC (SWR) stop end with outlet fixed to GI sheets for rain water collection and conveyance ,complete all as specified & as directed by Engr-in-Charge.
M&L for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 R ,complete all as specified & as directed by Engr-in-Charge.
M&L for Removal of existing concrete along with loose damaged and cracked concrete/cover concrete at all specified locations up to beyond the corroded steel reinforcements to a depth of 10mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chippers including high pressure water jetting to chipped concrete and reinforcement and removal and disposal of debris. Hard concrete shall not be removed. However if the rebar is corroded, concrete around it shall be removed. Depth of chipping will vary from 50mm to 150mm complete with labor, tools, scaffoldings machinery etc. ,complete all as specified & as directed by Engr-in-Charge. Note : The edges of the repair locations should be saw cut to a depth of at least 10 mm to avoid feather edging and to provide a square edge. Removal of dust, loose particles from concrete surface manually by wire brush, mechanically or any other means to obtain a sound surface over areas other than above.
M&L for the loosely bonded concrete of the R.C.C Deckslab, Beam / Girder and piles shall be chipped out using the mechanical cutter exposing the rebars.Apply FOSROC Rebakleens RR / or equivalent- Rust Remover using small brush and allow to react it for 16-24 hrs. Befoe applying protective etc complete coating,the surface should be wire brushed and thoroughly cleaned for for dust with dry cloth , complete all as specified & as directed.
Material & labour for providing and applying 50 mm thick Renderoc SP 40 - Polymer modified single component, alkaline resistant fibre reinforced, thixotropic, cementitious patch repair mortar. mixing of Renderoc SP 40 with recommended qty. of water using slow speed drill fitted with mixing paddle and apply the same to prepared surface. Finishing the same with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface, Cured Renderoc SP 40 shall exhibit compressive strength (BS 1881 Pt.116) -> 20 Mpa at 1 day & > 45 Mpa at 28 days, Tensile Strength (BS 6319 Pt.7) > 2.5 Mpa at 28 Days, Flexural Strength (BS 6319 Pt.3)>7 Mpa at 28 days, Drying shrinkage to ASTM C 157-93, 28 days < 1000 microstrain. Item rate is inclusive of materials all labour, tools and tackles, scaffolding and transportation etc. ,complete all as specified & as directed by Engr-in-Charge.
M&L for Providing and applying 50 mm thick microconcrete along with proper tight leak proof shuttering make : Fosroc Renderoc RG SPL / or equivalent- Polymer modified cementitious , low permeable, free flow , non shrink, self compacting microconcrete of grade M70 as per recommended w/c ratio and pouring as per the designed thickness , complete all as specified & as directed by Engr-in-Charge.
M&L for concrete surface is thoroughly cleaned once again using wire brush and after that applying One liberal coat of Make Fosroc Nitobond EP / or equivalent- two component Epoxy bonding agent shall be brush applied to the parent concrete ,complete all as specified & as directed by Engr-in-Charge.
S&F of wind turbine ventilation exhaust fan having characteristics of Overall Diameter 750mm, Overall Height 475mm, Wind Velocity (KMH) 8KMH (1950 Exhauster Appro.), Temp Difference (C) 3 to 5(c) , Stake Height 3 to 6 mtr, with material specifications of Typhonic Spindle System , Top Cover & Under Cover, Hindalco Made Aluminum, 2 mm Transparent FRP Sheet, Handmade Riveting, Nut Bolt Structure, 6.5 kg Fan Weight, 8 kg Dome Weight and as per manufacturer specifications ,complete all as specified & as directed by Engr-in-Charge.
M&L for de-watering and taking out sludge / algae / vegitation from SWTs of any size and removing sludge and cleaning the SWTs ,complete all as specified & as directed by Engr-in-Charge.
M&L for opening out cracks, making V grooves, removing the loose material and Filling with Dr Fixit Crack -X shrink free ,complete all as specified & as directed by Engr-in-Charge.
M&L for nominal mix PCC 1:2:4 using 40mm graded stone aggregate as in flooring or mass concreting, complete all as specified and as directed by Engr-in-charge.
M&L for Providing and injecting non shrink, free flow, high strength Anit-washout Polymer Cement Grout (the 5% polymer modified cement slurry through the nipple as fixed at a pressure not exceeding 2.0 to 2.5 kg/cm2 using grouting pump) including adding specified quantity of water in appropriate proportion to produce free flowing grout as per manufacturer's specifications into cracks/honey comb area of concrete/masonry by suitable gun / pump at required pressure as per the direction of the Engineer -in- Charge etc including necessery scaffolding ,form work etc complete all as specified and as directed by Engr-in-Charge.
M&L for Drilling holes for grouting and providing and inserting Rohibb Nylon nipple (10mm or12mm) with approved fixing compound as per technical specifications including cutting V groove in cracks making the crack dust free by blowing compressed air and then washing with water, sealing the distance between the injection nipples with approved epoxy putty and allow it to cure, as per the direction of the Engineer-in-charge etc including necessery scaffolding ,form work complete all as specified and as directed by Engr-in-Charge.
M&L for Providing and applying 15mm thick polymer mortar to load carrying members / R.C.C members in two layers( 10 mm thick base layer & 5 mm thick second layer ) in proportion of 1:5:15 ( 1 part Monobond : 5 Part Cement : 15 Part Quartz sand) by weight of polymer of approved make and quality, cement ratio for desire consistency and applying and finishing by floating, curing after initial setting time etc complete (With prior approval of SEMC) etc including necessery scaffolding ,form work etc,complete all as specified & as directed by Engr-in-Charge.
M&L for water proofing treatment on wall / concrete surface and applying 2 coats of Dr Fixit Rain coat exterior acrylic elastomeric coating ,complete all as specified & as directed by Engr-in-Charge. (Note:- seepage/dampness portion of bldgs only considered for measurement)
Excavating over areas, n exc 1.5 m deep and getting out in Hard / dense soil ,complete all as specified and as directed by Engr-in-charge.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface ,complete all as specified and as directed by Engr-in-charge.
M&L for 75 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base , complete all as specified and as directed by Engr-in-charge.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed by Engr-in-charge.
M&L for pre-cast cement concrete block masonary type C1 1:3:6 (20mm graded aggregate) set in cement concrete (1:4) with solid blocks, exc. 10 cm in width and setting in mortar, complete all as specified and as directed by Engr-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,in soft/loose soil ,complete all as specified & as directed by Engr-in-Charge.
M&L cement concrete type D2 1:4:8 (using 40mm graded stone aggregate )as in foundation,filling and mass concrete ,complete all as specified & as directed by Engr-in-Charge.
M&L preparation of newly steel surface of any description over 10cm width or girth not otherwisw described two coat of synthetic enamel paint over a coat of red oxide primer ,complete all as specified & as directed by Engr-in-Charge.
Supply and fix ,in repair,Galvanised strip of 20x3.00 mm as roof conductor and down conductor till test point,complete all as specified & as directed by Engr-in-Charge. Note-Galvanised strip to be jointed through brazing only
Supply and fix ,in repair,single pointed soild Aluminium rod 300mm long and 12mm dia fixed on suitable flat mounted plate and connected with roof/dowen conductor ,complete all as specified & as directed by Engr-in-Charge.
Supply and fix ,in repair, Medium grade GI pipe of 25 mm dia for fixing air termination rod, the pipe shall be suitably tapered for fixing the saddle insulator at an interval not exceeding 0.5 meter, the pipe should be laid vertically and should be properly supported, length of each vertically pipe should not exceed 3 RM, the air termination rod, down conductors should be insulated from the pipe ,complete all as specified & as directed by Engr-in-Charge.
Supply and fix ,in repair,test point terminals block and supply and fixing the same. The terminal block made with gun metal size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hex head of gun metal screw ,complete all as specified & as directed by Engr-in-Charge.
S&F Porcelain insulators for fixing Aluminimum strip on wall / Roof bldg with necessary screws, washers and nut bolts etc all Specified . Note - Rates are inclusive of copper srewes with washers for fixing Aluminium strip on porceline insulator with minimum size 1 inch and maximum size 1.5 inch with max external dia of screw is 8mm and 2 nos of GI nut for fixing insulator on wall all as per site requirment ,complete all as specified & as directed by Engr-in-Charge.
Material and labour for Brazing of galvanised earth strip 20/25/32 mm with available at site and reconnected properly ,complete all as specified & as directed by Engr-in-Charge.
M&L for earthing in replacement,complete with Galvanised earth plate electrode 600x 600x 3 mm buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal gound level and connected to earth test point by means of galvanised Strip of size 20x3 mm all as specified and shown in electric plate No 3 of MES SSR Part-I 2020 including earthwork,CI cover, PCC chamber in 1: 3 :6 type C1 ( for even finish on both the faces ) , protection and watering pipe, funnel, mesh etc,complete all as specified & as directed by Engr-in-Charge. Note : (1) 7.50 RM GI earth strip including GI pipe light grade is deemed to be included in the quoted rates, beyond 7.50 RM shall be measured and paid separately. (2) Earth resistance of earth pit should be less than 1.0 Ohms on testing after completion. If the desired earth resistance is not obtained the earthing will be redone at no extra cost.
S&F cross arm, bracing, supports, clamps and back plate fabricated from structural steel section including nuts, bolts, washers,welding, bending, drillingholes for bolts in any shape and any size inclusive of one primer coat, two coats of aluminium paints as indicateed ,complete all as specified and as directed by Engineer in charge.
Supply and fixing LED light fitting 2x16 Watt flameproof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size ,complete all as specified and as directed by Engineer in charge.
Supply and fix switch flame proof rotary type with termination box in LM6, 16A, single pole 250V ,complete all as specified and as directed by Engineer in charge.
Supply and fix flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A 250V, 2P+earth ,complete all as specified and as directed by Engineer in charge
Taking down carefully existing aluminium/Copper point wiring light, fan socket or power bell complete with fitting such as sockets, ceiling roses, pendants batten holders regulators socket, call bells & making good to the disturbed surfaces of walls, matching the colour with existing Surface ,complete all as specified and as directed by Engineer in charge. Note: Rate for making good shall be deemed to be included in quoted rate.
M & L for flame proof wiring complete with 1.5 Sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade,multi stranded with copper conductor through and including ERW steel conduit with conduit accessories fixed on wall/roof/floors etc including MS terminal boxes concealed in wall covered with Plastic laminated top sheet cover 3.00mm fixed with cadmium plate iron screws etc. with necessary fixing accessories and earth continuity copper conductor cable of size 1.5 Sqmm PVC insulated unsheathed FRLS copper conductor multi stranded cable 1100V grade and connection to common earth dolly complete all as specified for One Light /fan point/ controlled by one switch .
Ditto-All as per item No 70.00 above but for 2.5 Sqmm wire for 15 Amp socket outlet on independent board
S&F,in repair, Flame proof MCB distribution board double Door of sheet metal Single pole and neutral 8 way with 200 amps rated bus bar 240 volts including MCB SPN 32 Amps and MCB SP-06 Nos ,complete all as specified and as directed by Engineer-in-Charge.
Supplying, installation, commissioning and testing of submersible motor 5 HP BEE 5 Star rating, electic driven, 40 metre head in load, suitable for pumping raw water, complete all as specified and directed and comprising of the following specifications:-(i) submersible motor vertical type discharge dia 50 mm Suction 65 mm, at 40 metre head, 3000 RPM having bronze impeller and stainless steel shaft single stage directly (ii) Common base foundation of ISMC - 100 suitable for installation of above pump set duly drilled holes and painted with two coats of synthetic enamel paint over a coat of red oxide primer(iii) Boudrons type pressure gauge 3" dia dial type Note:- Sluice valve and reflux valve, DI pipe and fittings etc. required for suction and delivery and common header etc. shall be measured and paid separately in respective items.
M&L for earthing complete with Copper earth plate electrode 600x 600 x 3.15 mm buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal gound level and connected to earth test point by means of copper Strip of size 20x3 mm all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 including earthwork, PCC chamber in C1 type 1:3:6 , CI cover, protection and watering pipe, funnel, mesh etc all as required at site and all as directed. Note: (i) 7.5 RM Copper strip in deemed to be included in quoted rates beyond 7.5 RM strip shall be measured and paid separately. (ii) Earth resistance of earth pit should be less than 1.0 Ohms. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of Copper plate.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core ,complete all as specified and as directed by Engr -in-charge.
Taking down GI/CI/DI pipe of any size including light fittings & fixtures ,complete all as specified and as directed by Engr -in-charge.
Supply and lay ductile Iron pipe Class “K-7” ,100 mm (4”) dia ,including specials ,complete all as specified and as directed by Engr -in-charge.
Supply & fixing GI steel tubings of medium grade with all fittings and fixtures complete laid in trench/ floors/wall of size 40 mm dia including taking down existing tubing all as specified and directed by Engr-in-charge.
M&L for JP Joint suitable for 150mm dia pipe line including with packing materials, nuts, bolts, etc , complete all as specified and directed by Engr-in-charge.
M&L for CI/DI Special like bends, Tees, collar, Tail piece etc (any type & shape and angle) tapers of any type (straight, bend, increasing, decreasing or double socket etc) Tee pieces single branch, 'Y' junction double branch, cross (all sockets or socket and spigot) collars, caps and plugs suitable for CI/DI pipe upto 150 mm dia , complete all as specified and as directed by Engr-in-charge.
Supply and fix Valves, Sluice, flanged of class 1.0 PN, 100 mm (4”)dia , complete all as specified and as directed by Engr-in-charge.
Supply and fix Prestressed concrete poles of 9 meter long having 152 mm x 152 mm at top and 152 mm x 260 mm at bottom,Class 9, complete all as specified and as directed by Engr-in-charge.
Supply and fixing LED Street light fitting of 90 watt, 230 v AC IP-66, complete all as specified and as directed by Engr-in-charge.
S&F Junction box with fuse provision and suitable connection for three phase incomming cable 3 phase out going cable and single phase connection for light fitting with controlled MCB SP-6 Amps -01 Nos enclosed in thermo plastic in closed shock proof , complete all as specified and as directed by Engr-in-charge.
M&L for Repair of brick massonry valve pit chamber of inner dimension 100x100x100 cms suitable for sluice valves upto 100mm size, with , brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, including MS sheet cover of thickness 2 mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement and removing the debris from the site , complete all as specified and as directed by Engr-in-charge.
Excavation in trenches n. exc1.5 mtr wide and n.exc.1.50 mtr depth for laying of pipe/cable or other works and getting out in hard /dense soil , complete all as specified and as directed by Engr-in-charge.
Returning filling in excavated soil including spreading leveling and well ramming in layers n. exc 25 cm each any type of soil , complete all as specified and as directed by Engr-in-charge.
Removing the excavated materials not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point , complete all as specified and as directed by Engr-in-charge.
Supply, spreading in trenches fine dry river sand for cable protection and removing down getting by hand , complete all as specified and as directed by Engr-in-charge. Note:Punning thickness after compation shall be mesured for payment .
Supply and laying un reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches , complete all as specified and as directed by Engr-in-charge.
M&L for providing and applying of Dr Fixit / Fosroc / Equivalent exterior acrylic polyurethene elastomeric coating in 2 coats complete all as specified. (a) Apply initial layer of polyurethene elastomeric coating over cement slurry over concrete work (b) After 1 Hrs of drying of initial layer apply 2nd layer of polyurethene elastomeric coating in perpendiculer direction to 1st coat. (c) After that sprinkling the quartz sand over the coating for better adhesion of the next layer of protective screed.. Note : (a) Recommend Coverage rate is approximately 1.1 kg./m2/coat for 1 mm. (Minimum 2 coat.). (b) Allow the slurry to cure for at least 15-30 min. before applying second coat. Do not leave the first coat to dry longer than 8 hours.
MSK Everlast Enterprises
M/s PIONEER CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .