Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC A 2 206 SAI DWARKAMAI NIBM ROAD KONDHWA PUNE 411 048 | PUNE | MAHARASHTRA | 411048 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹32.1 L+₹1.2 L (3.96%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹33.4 L+₹2.5 L (8.21%)Rejected-Finance BLDG 9 FLAT 130 MIRA CO OP HOUSING SOCIETY LTD SALISBURY PARK GULTEKDI PUNE 411037 | PUNE | PUNE | MAHARASHTRA | 411037 | L3 | Rejected-Finance High Rate | |
| 4 | L4₹33.4 L+₹2.6 L (8.43%)Rejected-Finance | L4 | Rejected-Finance High Rate | |
| 5 | L5₹34.7 L+₹3.9 L (12.5%)Rejected-Finance MOURYA HEIGHTS SATAVNAGAR HANDEWADI ROAD HADAPSAR PUNE 28 | PUNE | MAHARASHTRA | 411028 | L5 | Rejected-Finance High Rate |
| Sl No | Description | Qty | Unit | REKHA ELECTRICALS L10 | L.T Associate L2 | Vijay Construction and Company L3 | GRACE CONSTRUCTIONS L14 | Ms. S.K. ASSOCIATES L4 | Parhar Enterprise L7 | Gauri Associates L5 | M/s Asrani and sons L6 | M/S Abhishek Builders L8 | M/s.BAJRANG CONSTRUCTION L12 | DURGA CONSTRUCTION & TRANSPORT L9 | EAST PUNE SERVICES L13 | SHREESAMARTH CONSTRUCTION L11 | SARATH ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Complete removal of existing old bitumenous tarfelt (water proofing treatment) including cement screed bed and PCC padding of any thickness and clean the surface with wire brush and washing with water to achieve the original surface of slab and removing the debris outside the defence land all as specified and directed. | 4,900 | Sqm | 15 ₹73,500 | 27 ₹1,32,300 | 30 ₹1,47,000 | 30 ₹1,47,000 | 30 ₹1,47,000 | 20 ₹98,000 | 20 ₹98,000 | 10 ₹49,000 | 10 ₹49,000 | 75 ₹3,67,500 | 30 ₹1,47,000 | 50 ₹2,45,000 | 9 ₹44,100 Lowest | 9 ₹44,100 Lowest |
| 2.00 | M&L for water proofing treatment to RCC roof slab, walls, chajjas etc, shall be carried complete all as specified and directed.
(a) M&L for 10 mm thick plaster screed bed layer in CM 1:3 on concrete surfaces by using water proofing compound
(b) Preparing plastered surfaces of roof slab, walls, chajjas etc, by brooming with broom sweeping free from dirt dust etc and evenly applying one coat of oil based cold bituminous primer @ 0.7Kg per sqm of area M&L for complete all as specified.
(c) Laying APP polymer modified approved membrane, non woven, polyster, weighing not less than 3.6 Kg/Sqm and 3 mm thick with laps and overlaps as specified and joints sealed and applied by torch application method.
(d) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces. | 4,900 | Sqm | 421 ₹20,62,900 | 380 ₹18,62,000 Lowest | 450 ₹22,05,000 | 570 ₹27,93,000 | 400 ₹19,60,000 | 490 ₹24,01,000 | 390 ₹19,11,000 | 380 ₹18,62,000 Lowest | 440 ₹21,56,000 | 505 ₹24,74,500 | 430 ₹21,07,000 | 525 ₹25,72,500 | 540 ₹26,46,000 | 390 ₹19,11,000 |
| 3.00 | Supply only integral waterproofing compound. | 300 | Ltrs | 140 ₹42,000 | 40 ₹12,000 Lowest | 90 ₹27,000 | 70 ₹21,000 | 40 ₹12,000 Lowest | 60 ₹18,000 | 200 ₹60,000 | 70 ₹21,000 | 150 ₹45,000 | 150 ₹45,000 | 70 ₹21,000 | 150 ₹45,000 | 108 ₹32,400 | 51 ₹15,300 |
| 4.00 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate for levelling course for consolidated average thickness 40 mm complete all as specified and directed. | 4,400 | Sqm | 170 ₹7,48,000 | 108 ₹4,75,200 | 110 ₹4,84,000 | 160 ₹7,04,000 | 110 ₹4,84,000 | 100 ₹4,40,000 Lowest | 130 ₹5,72,000 | 200 ₹8,80,000 | 150 ₹6,60,000 | 115 ₹5,06,000 | 230 ₹10,12,000 | 130 ₹5,72,000 | 135 ₹5,94,000 | 117 ₹5,14,800 |
| 5.00 | M&L for PCC 1:2:4 type B0 using 12.5 mm graded agg as in PCC padding in roof kerbs or mud stops, rounded and chamfered on edges and on chajjas laid over RCC surface finished even and smooth without using extra cement includng necessary water proofing chemicals complete all as specified and directed.
(Note : WPC shall be measured and paid separately) | 5 | Cum | 4,500 ₹22,500 | 6,393.4 ₹31,967 | 4,500 ₹22,500 | 2,000 ₹10,000 Lowest | 6,500 ₹32,500 | 3,500 ₹17,500 | 5,800 ₹29,000 | 5,000 ₹25,000 | 6,000 ₹30,000 | 5,850 ₹29,250 | 3,500 ₹17,500 | 6,000 ₹30,000 | 6,300 ₹31,500 | 3,900 ₹19,500 |
| 6.00 | Disconnecting existing OH tanks of any capacity for repairs, cleaning, or water proofing treatment at base of tank etc. and reconnecting and re-fixing in same position after cleaning of tank and including necessary GI fittings such as Tank nipple, union, Tee ect, completion water proofing complete all as specified and directed. | 30 | Each | 120 ₹3,600 Lowest | 200 ₹6,000 | 500 ₹15,000 | 150 ₹4,500 | 210 ₹6,300 | 300 ₹9,000 | 500 ₹15,000 | 500 ₹15,000 | 700 ₹21,000 | 150 ₹4,500 | 500 ₹15,000 | 500 ₹15,000 | 900 ₹27,000 | 360 ₹10,800 |
| 7.00 | Taking down steel tubing necessary fittings connection etc for 20 mm bore pipe complete all as specified and directed. | 120 | Rm | 5 ₹600 Lowest | 20 ₹2,400 | 10 ₹1,200 | 20 ₹2,400 | 22 ₹2,640 | 10 ₹1,200 | 20 ₹2,400 | 20 ₹2,400 | 10 ₹1,200 | 15 ₹1,800 | 20 ₹2,400 | 50 ₹6,000 | 9 ₹1,080 | 6 ₹720 |
| 8.00 | M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed. | 30 | Rm | 120 ₹3,600 | 100 ₹3,000 | 40 ₹1,200 | 150 ₹4,500 | 102 ₹3,060 | 45 ₹1,350 | 90 ₹2,700 | 80 ₹2,400 | 65 ₹1,950 | 150 ₹4,500 | 130 ₹3,900 | 300 ₹9,000 | 18 ₹540 Lowest | 51 ₹1,530 |
| 9.00 | S&F tubes medium grade galvanized with all fittings and fixed M&L for complete to walls and ceiling or laid in floors 20 mm dia complete all as specified and directed. | 50 | Rm | 200 ₹10,000 Lowest | 200 ₹10,000 Lowest | 240 ₹12,000 | 260 ₹13,000 | 202 ₹10,100 | 240 ₹12,000 | 270 ₹13,500 | 300 ₹15,000 | 240 ₹12,000 | 225 ₹11,250 | 250 ₹12,500 | 300 ₹15,000 | 306 ₹15,300 | 222 ₹11,100 |
| 10.00 | Supplying and laying 20mm bore of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all required fittings complete all as specified and directed. | 50 | Rm | 195 ₹9,750 | 180 ₹9,000 | 190 ₹9,500 | 200 ₹10,000 | 195 ₹9,750 | 170 ₹8,500 | 290 ₹14,500 | 250 ₹12,500 | 210 ₹10,500 | 175 ₹8,750 | 70 ₹3,500 Lowest | 300 ₹15,000 | 360 ₹18,000 | 210 ₹10,500 |
Tender Value
₹48.2 L
EMD Value
₹96,460
Closing Date
15 Dec 2025, 6:00 pmClosed
Garrison Engineer (central) Pune
Garrison Engineer (Central) Pune, Arjun Marg, Pune-411001
8653 SPECIAL REPAIR TO ROOF AND OTHER CONNECTED WORK AT BLDGS OF AFMC UNDER GE (CENTRAL) PUNE
2025_MES_741328_1
8653 SPECIAL REPAIR TO ROOF AND OTHER CONNECTED WORK AT BLDGS OF AFMC UNDER GE (CENTRAL) PUNE
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer (central) Pune
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer (Central)
₹96,460
Yes
21 Feb 2026
24 Nov 2025
17 Dec 2025
24 Nov 2025
25 Nov 2025
8 Dec 2025
Amount
Complete removal of existing old bitumenous tarfelt (water proofing treatment) including cement screed bed and PCC padding of any thickness and clean the surface with wire brush and washing with water to achieve the original surface of slab and removing the debris outside the defence land all as specified and directed.
M&L for water proofing treatment to RCC roof slab, walls, chajjas etc, shall be carried complete all as specified and directed. (a) M&L for 10 mm thick plaster screed bed layer in CM 1:3 on concrete surfaces by using water proofing compound (b) Preparing plastered surfaces of roof slab, walls, chajjas etc, by brooming with broom sweeping free from dirt dust etc and evenly applying one coat of oil based cold bituminous primer @ 0.7Kg per sqm of area M&L for complete all as specified. (c) Laying APP polymer modified approved membrane, non woven, polyster, weighing not less than 3.6 Kg/Sqm and 3 mm thick with laps and overlaps as specified and joints sealed and applied by torch application method. (d) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces.
Supply only integral waterproofing compound.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate for levelling course for consolidated average thickness 40 mm complete all as specified and directed.
M&L for PCC 1:2:4 type B0 using 12.5 mm graded agg as in PCC padding in roof kerbs or mud stops, rounded and chamfered on edges and on chajjas laid over RCC surface finished even and smooth without using extra cement includng necessary water proofing chemicals complete all as specified and directed. (Note : WPC shall be measured and paid separately)
Disconnecting existing OH tanks of any capacity for repairs, cleaning, or water proofing treatment at base of tank etc. and reconnecting and re-fixing in same position after cleaning of tank and including necessary GI fittings such as Tank nipple, union, Tee ect, completion water proofing complete all as specified and directed.
Taking down steel tubing necessary fittings connection etc for 20 mm bore pipe complete all as specified and directed.
M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
S&F tubes medium grade galvanized with all fittings and fixed M&L for complete to walls and ceiling or laid in floors 20 mm dia complete all as specified and directed.
Supplying and laying 20mm bore of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all required fittings complete all as specified and directed.
Refixing tubes medium grade galvanized with all fittings and fixed to walls and ceiling or laid in floors 20 mm dia complete all as specified and directed.
Taking down steel tubing necessary fittings connection etc for 25 mm bore pipe complete all as specified and directed.
S&F tubes medium grade galvanized with all fittings and fixed to walls and ceiling or laid in floors 25 mm dia complete all as specified and directed.
Refixing tubes medium grade galvanized with all fittings and fixed to walls and ceiling or laid in floors 25 mm dia complete all as specified and directed.
S&F gun metal globe or gate valves with iron wheel head screwed both end for iron pipe and fixed in repairs to 20 mm bore pipe complete all as specified and directed.
S&F in repair PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110 mm dia complete all as specified and directed.
S&F in repair PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 75 mm dia complete all as specified and directed.
S&F PVC (SWR) bends of 110 mm dia, any radius complete all as specified and directed.
S&F PVC (SWR) bends of 75mm dia, any radius complete all as specified and directed.
Supply and fix in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed in repairs of pipe 20 mm dia complete all as specified and directed.
Dismantling polycarbonate roofing sheets (plian or corrugated etc) complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed.
Supply and fix steel hollow steel section as in main and cross beams, hip and jack rafters; purlins where connected to common rafter and running rails and guides for sliding door fixed with angle cleat or other connecting plates etc conforming to IS-4923-1997 of FE 410-W (Gde-E-250) quality A complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F 10mm thick good quality corrugated polycarbonate roofing sheet polished complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:4), the surface even and smooth without extra cement complete all as specified and directed.
S&F spherical wind driven turbine ventilator having dia of neck 610 mm and speed 350 RPM with following specification :- (i) Material used : Totally Aluminium built (ii) No of vanes : 0.5mm thickness, 38 Numbers (iii) Center shalf : Stainless steel (iv) Bearing : self lubricated - 02 Nos (v) Riverts : Aluminium Pneumatic Riverts (vi) Turbine Doom thickness : 1mm (vii) Turbine outer dia : 680mm (viii) Turbine doom dia : 380mm (ix) Turbine Rotor dia : 655 mm (x) Turbine Throat dia : 610mm (xi) Turbine Height : 360mm (xii) Turbine weight : 3.75 Kgs complete all as specified and directed. Note :- Rate are deemed to be inclusive of scaffolding and safety measures for work to be carried out upto height of 10.0 Mtr from ground level.
M&L for dismantling and removal of damged RCC portion such as slab/columns/beams/chajjas/parapet /roof projection/balcony/staircase and applying two coats with single component, fiber reinforced, dual shrinkage- compensated thixotropic, cementitious mortar Sika monotop 122F capable of applying up to 20-25mm thick in double layer or multiple layers initially by hand and finishing with troweled carefully compacting the same around the rebar and finishing to bring it in line with existing concrete surface with an average specified thickness complete all as specified and directed. Make : STP/Chemsol/Bostik/Chemsol/Choksey/Foscroc as approved by GE.
L.T Associate (BID ID -3496340)
Vijay Construction and Company (BID ID -3496617)
Ms. S.K. ASSOCIATES (BID ID -3499241)
Gauri Associates (BID ID -3500225)
M/s Asrani and sons (BID ID -3500447)
Parhar Enterprise (BID ID -3500031)
M/S Abhishek Builders (BID ID -3500628)
DURGA CONSTRUCTION & TRANSPORT (BID ID -3501034)
REKHA ELECTRICALS (BID ID -3495630)
SHREESAMARTH CONSTRUCTION (BID ID -3500157)
M/s.BAJRANG CONSTRUCTION (BID ID -3500674)
EAST PUNE SERVICES (BID ID -3499723)
GRACE CONSTRUCTIONS (BID ID -3498248)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
BOQ_830100.xls
BOQ • 4.13 MB
TENDER8653.pdf
Tender Documents • 1.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .