| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹27.3 L+₹1.6 L (6.14%)Rejected-Finance 00 A N SINHA ROAD KADAM KUAN PATNA BIHAR 800003 | PATNA | BIHAR | 800003 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹31.6 L+₹5.8 L (22.7%)Rejected-Finance | L3 | Rejected-Finance Other than lowest |
Tender Value
₹32.4 L
EMD Value
₹64,800
Closing Date
31 Jul 2020, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
COMPREHENSIVE E/M WORKS AND REPAIR/ MAINT OF FIRE ALARM SYSTEM, DG SET IN MH, REPAIR/ MAINT OF SOLAR WATER HEATER AND REPAIR/ MAINT OF MT VEHICLE AT BAIRAGARH UNDER GE BHOPAL
2020_MES_358217_1
8677/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
BHOPAL
CLASS E CAT b i
6 documents required · 6 mandatory
₹500
Yes
GE BHOPAL
₹64,800
Yes
4 Sept 2020
3 Jul 2020
3 Aug 2020
3 Jul 2020
31 Jul 2020
17 Jul 2020
Amount
Comprehensive maint with material and servicing, oiling, Engine tuning, overhauling fixture accessories replacement of first moving parts changing oil/fuel filters, replacement of bulbs, fuses, repairing of wiring, replacement of coolant, brake oil, steering oil, engine oil, cleaning and maint of radiators and Air Filter /Air Cleaner, maint of battery with electrolyte solution, distilled water, wheel alignment, Change of Wheel Greasing, Greasing of all mechanical moving parts, Checking of the Battery Charging system as per manufacturer recommendation of the following Eicher vehicles complete all as directed by the Engineer-in-Charge. Note: Major repairs & Parts and Engine Oil shall be measured under relevant items and paid seperately.
Vehicle BA. No. 03D-154424E
Vehicle BA. No. 09D-181304A
Vehicle BA. No. 09D-181305N
Comprehensive maint with material and servicing, oiling, tuning, overhauling fixture accessories replacement of first moving parts changing oil/fuel filters, replacement of bulbs fuses, repairing of wiring, replacement of coolant, brake oil, steering oil, engine oil, cleaning and maint of radiators and Air Filter/Air Cleaner, maint of battery with electrolyte solution, distilled water, wheel alignment, Change of Wheel Greasing, Greasing of all mechanical moving parts, Checking of the Battery Charging system as per manufacturer recommendation of the following Tata Mobile/Tata Indigo/Maruti Zypsy/Maruti Omni vehicles complete all as directed by the Engineer-in-Charge. Note: Major repairs & Parts and Engine Oil shall be measured under relevant items and paid seperately.
Vehicle BA. No. 09C-085832K
Vehicle BA. No. 07C-082122M
Vehicle BA. No. 09B-103879N
Vehicle BA. No. 99B-68184X
Vehicle BA. No. 11B-111599M
Comprehensive maint with material and servicing, oiling, Engine tuning, overhauling fixture accessories replacement of first moving parts changing oil/Air filters, replacement of bulbs fuses, seat cover replacement, mudguard flab, side mirror, tail lamp fitting, accelerator & clutch wire, chain ,clutch plate etc repairing of wiring, Shock Abserber Oil , engine oil, cleaning and maint of battery with electrolyte solution, distilled water, as per manufacturer recommendation of the following Motor Cycles complete all as directed by the Engineer-in-Charge.
Note: Major repairs & Parts and Engine Oil shall be measured under relevant items and paid seperately.
Vehicle BA. No.09A-061336K ( Make : Royal Enfiled )
Vehicle BA. No. 04A-056211L ( Make : Royal Enfiled )
Vehicle BA. No. 11A-062373K (Hero Honda Spl+ )
Vehicle BA. No. 10A-061838E (Hero Honda Spl +)
Vehicle BA. No. 11A-062376W (Hero Honda Spl +)
Vehicle BA. No. 11A-062375W (Hero Honda Spl +)
Taking down the existing defective Self starter from Eicher Vehicle and replacement of work out spares like Bendex drive, carbon brus, solinoid coil, Armature including rewinding stator, refixing in same position and testing complete all as specified and directed by the Engineer-in-charge.
Taking down the existing defective Self starter from Maruti Gypsy and replacement of work out spares like Bendex drive, carbon brush, solinoid coil, Armature including rewinding stator, refixing in same position and testing complete all as specified and directed by the Engineer-in-charge.
Taking down the existing defective Alternator from Tata Mobile Vehicle and replacement of work out spares like Rotor Coil, Field coil, Rectifier, Electronic regulator with Carbon brush with Holder, refixing in same position and testing complete all as specified and directed by the Engineer-in-charge.
Taking down the existing defective Alternator from Eicher Vehicle and replacement of work out spares like Rotor Coil, Field coil, Rectifier,Electronic regulator with Carbon brush with Holder, refixing in same position and testing complete all as specified and directed by the Engineer-in-charge
Dismantling and taking down Eicher vehicle defective clutch system and repair replacement of worn-out spare and refixing, testing complete all as specified and directed by Engineer-in-Charge Note : The rate for the minor parts required for repair other than the parts consider in the below is deem to be included.
Supply only the following spare parts of Eicher of original manufacture:-
Clutch plate
Pressure plate with springs
Clutch cylinder
Sleeve cylinder
Release Bearing
Dismantling and taking down Tata mobile vehicle defective clutch system and repair replacement of worn-out spare and refixing, testing complete all as specified and directed by Engineer-in-Charge Note : The rate for the minor parts required for repair other than the parts consider in the below is deem to be included.
Supply only the following spare parts of Tata Mobile of original manufacture:-
Clutch plate
Pressure plate with springs
Release bearing
Clutch Cylinder
Sleeve Cylinder
Dismantling and taking down Maruti Gypsy vehicle defective clutch system and repair replacement of worn-out spare and refixing, testing complete all as specified and directed by Engineer-in-Charge. Note : The rate for the minor parts required for repair other than the parts consider in the below is deem to be included.
Supply only the following spare parts of Maruti Gypsy of original manufacture:-
Clutch plate
Pressure plate with springs
Release bearing
Repair and overhauling of Eicher Vehicle defective shafting system and checking of parts such as propeller shaft, centre bearing, centre bearing clamp & rubber, universal cross, yok teeth and testing complete all as specified and directed by engineer-in-Charge. Note : The rate for the minor parts required for repair other than the parts consider in the below is deem to be included.
Supply only the following spare parts of Eicher of original manufacture:-
Centre bearing
Centre bearing rubber
Universal cross
Yeok & teeth
All as per item No 15.00 above but vehicle Tata Mobile
Supply only the following spare parts of Tata Mobile of original manufacture:-
Centre bearing
Centre bearing rubber
Centre bearing clamp
Yeok & teeth
Repair and overhauling of Eicher vehicle defective brake system and checking of parts such as wheel cylinder, master cylinder, wheel brake shoe, wheel brake spring system and testing complete all as specified and directed by Engineer-in-charge. Note : The rate for the minor parts required for repair other than the parts consider in the below is deemed to be included.
Supply only the following spare parts of Eicher of original manufacture:-
Wheel cylinder front right
Wheel cylinder front left
Wheel cylinder rear right
Wheel cylinder rear left
Master cylinder
Brake shoe
Brake shoe spring & locking assembly
Repair and overhauling of Tata Mobile defective brake system and checking of parts such as front disc brake, rear wheel cylinder, master cylinder, rear brake shoe, front disc brake pad, front disc brake caliper assembly, complete brake pipe, rear wheel brake shoe spring & locking assembly and testing complete all as specified and directed by Engineer-in-Charge Note : The rate for the minor parts required for repair other than the parts considered below is deem to be included.
Supply only the following spare parts of Tata Mobile of original manufacture:-
Front brake disc
Rear wheel cylinder
Master cylinder assembly
Rear brake shoe
Front disc brake pad
Front disc brake caliper assembly
Rear wheel brake shoe spring & locking assembly
Repair and overhauling of Maruti Gypsy defective brake system and checking of parts such as front disc brake, rear wheel cylinder, master cylinder, rear brake shoe, front disc brake pad, front disc brake caliper assembly, complete brake pipe, rear wheel brake shoe spring & locking assembly and testing complete all as specified and directed by Engineer-in-Charge Note : The rate for the minor parts required for repair other than the parts consider in the below is deem to be included.
Supply only the following spare parts of Maruti Gypsy of original manufacture:-
Front brake Drum
Rear wheel cylinder
Master cylinder assembly
Rear brake shoe
Front brake pad
Rear wheel brake shoe spring & locking assembly
Repair and overhauling of Eicher vehicle defective suspension system and checking of parts such as shock absorber, front spring leaf, centre bolt, front spring leaf hanger, front spring leaf, shackle pin, rear spring leaf, rear spring leaf hanger, rear shackle pin and complete all as specified and directed by engineer-in-charge. Note : The rate for the minor parts required for repair other than the parts consider in the below is deem to be included.
Supply only the following spare parts of Eicher of original manufacture:-
Shock absorber Front/Rear
Shock absorber bush
Centre bolt
Hanger
Hanger bolt TVS
Hanger rear
Hanger Jhula
Shackle pins
Lock pin
Repair and overhauling of Tata Mobile defective suspension system and replacement of the following spare parts as directed. (Spare parts will be paid seperately) and refixing the same and testing complete all as specified and directed by Engineer-in-charge. Note : The rate for the minor parts required for repair other than the parts consider in the below is deem to be included.
Supply only the following spare parts of Eicher of original manufacture:-
Shock absorber bush
Shock absorber
Upper link
Lower link
Ball joint
Hanger
Shackle pin
Centre bolt
UJ Cross
Tie rod end
Repair and overhauling of defective Shock absorber (Front & Rear) of motor cycle (Royal Enfield & Hero Honda) and carry out the repair including replacement of Coil Spring Oil Seal, Rubber Boot etc complete all as specified and directed by engineer-in-charge.
Replacement of floor mat and Mud guard rubber mat of Tata mobile complete all as specified and directed by engineer-in-charge. (including all material use for fixing)
All as per item No 30.00 but Eicher Vehicle complete all as specified and directed by engineer-in-charge.
Taking out seat cover of vehicle Tata Mobile and repair the old one by stitching the worn out seat by filling seat materials of good quality and refixing the new one to their proper place neatly complete all as specified and directed by engineer-in-charge.(including all material use for fixing)
All as per item no 32.00 above but Eicher Vehicle.
Removing wheel complete with tyre and tube, taking out tube repair, puncher of tube of vehicles Tata mobile and refixing properly complete all as specified and directed by engineer-in-charge.
All as per item No 34.00 above but Eicher Vehicle
All as per item No 34.00 above but R/E bullet and hero honda
Scrapping out old painted surface of Vehicles Eicher and M&L for one coat of enameled paint over two coats of red oxide primer including repair to minor dents of vehicles, repairs to scratches, minor damage repair by welding and concerned polishing of veh complete all as specified and directed.
Scrapping out old painted surface of Vehicles Tata Mobile/Maruti Gypsy/Maruti Omni and M&L for one coat of enameled paint over two coats of red oxide primer including repair to minor dents of vehicles, repairs to scratches, minor damage repair by welding and concerned polishing of veh complete all as specified and directed.
Dismantling and taking down the gear box of Tata mobile, repair and overhauling including replacement of worn spare parts (spare parts will be measured and paid separately) refixing the same in original position and testing complete complete all as specified and directed. Note : The rate for the minor parts required for repair other than the parts consider in the below is deem to be included.
Supply only the following spare parts of Tata Mobile of original manufacture:-
Gear liver kit
Synchronizer(1 the to 4th gear)
Gear reverse pinion
Gear pinion Ist, 2nd, 3rd & 4th
Counter
All as per item No 39.00 above but Eicher
Supply only the following spare parts of Eicher of original manufacture:-
Gear liver kit
Sechronizer(1 st to 4th gear)
Gear reverse pinion
Gear pinion Ist, 2nd, 3rd & 4th
Counter
Taking down the existing defective injector and fuel injection pump (FIP) for the Tata mobile engine and replacement of work out spares like delivery valves, Nozzles, bearings, fly weight, packing kit, and copper washer kit and recalibration of FIP along with Injector and refixing in same position and testing of full load checking of pressure and checking the solinoid coil complete all as specified and directed by the Engineer-in-charge
Taking down the existing defective Carburetor pump for the Maruti Gypsy and replacement of new spares pump like and recalibration of pump along with elctric coil and refixing in same position and testing of full load checking of pressure and checking the solinoid coil complete all as specified and directed by the Engineer-in-charge
Supply only coolant.
Supply only brake oil.
Supply Only distilled water.
Supply Only Gear and Differential Oil.
Supply Only Engine Oil 20W 40.
Supply only the following spares for vehicle Eicher of original manufacture:-
Radiator Hose pipe
Fan belt
Timing belt
Back light Assy
Acceleration cable
Clutch cable
Looking glass
Glass handle inner
Glass machine
Door lock
Door hinge
Head light assembly
Indicator and Parking Light Assy
Supply only the following spares for Tata Mobile of original manufacture:-
Radiator Hose pipe
Fan belt
Timing belt
Acceleration cable
Looking glass (mirror)
Glass handle inner
Glass machine
Door lock
Door hinge
Head light assembly
Indicator and parking light Assy
M&L for denting damage portion of vehicle including touching, welding, matching with existing painting with the same color of any vehicle complete all as specified and as directed.
Disconnecting, removing and dismantling radiator assembly from the following vehicels and descaling the radiator throughly with CTC solution/any other chemical solvent agent as approved by the Engineer-in-pcharge, stopping of leakeage at place to copper cores and tubes by brazing scapping the existing Oil paint, dusting and painting the radiator with enamelled paint etc re-installing and commissioning all as directed by Engineer-in-charge
Tata Mobile
Eicher
Gypsy
Disconecting the existing battery of capacity 12V 70/88 AH from the Vehicle, taking it to battery workshop, draining out the complete unserviceable sulphuric acid from the battery, filling up with new sulphuric acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to Vehicle for satisfactory function all as directed by Engineer-in-Charge.
M&L for carry out the Wheel alignment of the Tata Mobile to Authrised centre including Change of the tyre like front left to front right and front right to left or front to rear and rear to front vehicle etc complete all as specified and as directed directed by the Engineer-in-charge.
M&L for carry out the Wheel alignment of the Eicher to Authrised centre including Change of the tyre like front left to front right and front right to left or front to rear and rear to front vehicle etc complete all as specified and as directed directed by the Engineer-in-charge.
Repair and Overhauling of Clutch and transmission system of Motor cycle Royal Enfield and carry out the repair including replacement of Clutch plate, spring circlips, transmission chain etc complete all as specified and directed by the Engineer-in-Charge.
Repair and Overhauling of Clutch and transmission system of Hero Honda Motor cycle and carry out the repair including replacement of Clurtch plate, spring circlips, transmission chain etc complete all as specified and directed by the Engineer-in-Charge.
Supply and fix Battery 12 V 5 Ah complete all as specified and directed by Engineer-in-Charge. Make: Exide/Kirloskar/AMCO
Supply and fix Battery 12V 2.5 Ah complete all as specified and directed by Engineer-in-Charge. Make: Exide/Kirloskar/AMCO
Supply and fix Battery 12V 70 Ah complete all as specified and directed by Engineer-in-Charge. Make: Exide/Kirloskar/AMCO
Supply and fix Cover Outer of size 7.00X16,12 PR with inner tube suitable for Tata Mobile Vehicle complete all as specified and directed by Engineer-in-Charge. Make: JK Tyre/Apollo tyre /MRF/Ceat
Supply and fix Cover Outer of size 2.75X18 - 48P/4PR with inner tube suitable for Spl+ complete all as specified and directed by Engineer-in-Charge. Make: Apollo tyre /MRF/Ceat
Supply and fix Cover Outer of size 2.75X18 - 42P/4PR with inner tube suitable for Spl+ complete all as specified and directed by Engineer-in-Charge. Make: Apollo tyre /MRF/Ceat
REPAIR AND MAINT OF DG SETS AND SOLAR WATER HEATER
M&L for complete servicing of solar hot water system (solar water heater, flate plate collector type), with cleaning of sluge deposited in pipe line of solar pannel by using cleaning regent, check and repair of pipe line for any leakage, including carring out brazing of copper pipe for leakage, cleaning of glass shell, cleaning of hot water tank, replacement of u/s clamps, adopter, hose pipe and minor parts etc including complete sevicing to keep the plant functional of capacity up to 300 LPD (Note :- The spare parts shall be measured and paid for separate under respective items).
M&L for replacement of electrical heating element of 3.0 KW (long thread type, as per existing), ISI marked, of solar water heater of cap up to 300 LPD. Make: Solar Element or equivelent as approved by GE.
M&L for replacement of thermostate, long body, ISI marked of solar water heater of cap up to 300 LPD.
M&L for replacement of solar hot water tank with thermal insulation suitable for solar water heater of cap 100 LPD. Make : TATA/ Supreme solar.
M&L for replacement of solar hot water tank with thermal insulation suitable for solar water heater of cap 200 LPD. Make : TATA/ Suprem solar.
M&L for replacement of solar hot water tank with thermal insulation suitable for solar water heater of cap 300 LPD. Make : TATA/ Suprem solar.
M&L for replacement of hot water pipe insulation with glass wool and aluminium cladding 20 mm bore including all material as required and directed by EIC.
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 2 way, single door without bus bar, enclosure made up of CRCA sheet steel RAL 9003 powder coated, IP 30 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed by Engr-in-charge. Make- Legrand/ Seimens/ Schinder.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor FRLS cable (with colour code), drawn in but including non metallic rigid PVC conduit of 25 mm dia, ISI marked including PVC insulated unsheathed 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete. Make of wire : L&T / Polycab/ C&S
S&F in repair MCB SPN 5 to 32 amps 10 KA , 'C' Curve including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-In-Charge Make- Legrand/ Seimens/ Schinder.
Repair & comprehensive maintenance of DG sets of any make of the following capacities which include replacement of worn out spares such as fuel filter, oil filter, lubricating oil hoses, V- belt, Oil pipes, fuel pipe, water pump, cut out and tightening of nut bolts, washers etc of DG sets complete all as specified and directed.
750 KVA capacity
100/110/160 KVA capacity
30 / 50/ 62.5 KVA capacity
Periodical maintenance of DG set 750 KVA by authorised representative of manufacturer (OEM) by "B" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 750 KVA by authorised representative of manufacturer (OEM) by "C" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 750 KVA by authorised representative of manufacturer (OEM) by "D" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 100/110/160 KVA by authorised representative of manufacturer (OEM) by "B" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 100/110/160 KVA by authorised representative of manufacturer (OEM) by "C" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 100/110/160 KVA by authorised representative of manufacturer (OEM) by "D" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 30/50/62.5 KVA by authorised representative of manufacturer (OEM) by "B" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 30/50/62.5 KVA by authorised representative of manufacturer (OEM) by "C" check of Engines complete all as specified and directed.
Replacement of the following spare parts for 30 to 160 KVA of Make:- Kirloskar / Greaves Crompton / Cummins / Mahendra complete all as specified and directed:-
Head Gasket Kit complete
Fuel Filter
Lubricating Oil Filter
Hose Pipe Set
Replacement of the following spare parts for 750 KVA of Make:- Kirloskar / Greaves Crompton / Cummins / Mahendra complete all as specified and directed:-
Head Gasket Kit complete
Fuel Filter
Lubricating Oil Filter
Hose Pipe Set
Dismantling and taking down radiator assy from engine of any capacity for repairs including descaling, bracing as necessitated to plug leakages, M & L for transporting of the radiator of capacity 30-750 KVA and repair/maintenance to the radiator fins with the help of cleaning coil solution and cleaning the radiator complete and repair to the leakage places by means of gas welding and including initial filling up coolant and re-fixing after repairs including replacement of worn out nut bolts, washers, etc; and testing complete all as specified and directed.
Dismantling and removing fuel injection pump from DG set for repairs including re-calibration at authorised service centres, replacement of necessary spare parts such as delivery valves, plunger, 'O' ring, springs etc and refixing, testing complete all as specified and directed of the following capacity:-
750 KVA capacity
100/110/160 KVA capacity
30 to 62.5 KVA capacity
M & L for cleaning of fuel tank of DG sets of any make and capacity including replacement of fuel level indicating tube and markings complete all as specified and directed.
Replacement of Lubrication Oil 20 W 40 complete all as specified and directed. Make :- Castrol / Servo
M&L for reconditioning of unserviceable battery 12 V, 180 AH by replacing complete cells, PVC seperators, electrolyte, terminals and final sealing, recharging and testing complete all as specified and directed.
M&L in replacement maintenance free lead acid battery 12 volt, 180 Ah with minium 24 months warranty) of stand alone solar LED light complete all as specified and directed. [MAKE:- EXIDE / TATA / AMERON]
Replecement of flame proof asbestos rope of specified dia wrapped around the exhaust pipe complete all as specified and directed.
Repair / Overhauling of self starter 12 / 24 Volt of any make / capacity including replacement of minor items such as carbon brushes, nuts, bolts etc; all as necessitated complete all as specified and directed. Note:- All additional spares as required will be measured and paid seperately.
Replacement of spares for self starter 12 / 24 V complete all as specified and directed :-
Field coil
Armature
Clutch assembly
Replacement of battery lead, copper conductor 25 Sq mm, multi stranded, PVC insulated with suitable terminals at both ends complete all as specified and directed.
M&L for painting of DG set of 30 to 160 KVA capacity with two coats of spray painting with synthetic enamel paint as per colour code after preparation of old painted surfaces and writing SM / MES Nos etc; complete all as specified and directed.
Replacement of battery terminal of brass suitable for 12V, 180 AH battery complete all as specified and directed.
Replacement of Fan belts as per sample for DG sets of capacity:-
750 KVA capacity
160 KVA capacity
100 KVA capacity
30 to 62.5 KVA capacity
Replacement of fuel flexible pipe, heavy duty with check nuts for DG sets of any make/capacity complete all as specified and directed.
Dismantling of alternator assy 30 to 750 KVA DG Set and taking out regulating transformer carefully and rewinding of regulating transformer including refitting and testing complete all as specified and directed.
Replacement of only oil pressure gauge as per sample complete all as specified and directed.
Replacement of only temperature gauge as per sample complete all as specified and directed.
Replacement of only water pump suitable for DG sets of following capacity:-
750KVA capacity
30 to 160 KVA capacity
Replacement of Control Safety (Lub oil) for 30 to 750 KVA DG Set complete all as specified and directed.
Replacement of Control Safety (Water) Part No. for 30 to 750 KVA DG set complete all as specified and directed.
Replacement of S.D. Valve for 30 to 750 KVA DG set complete all as specified and directed.
Replacement of Electronic AVR assembly Complete make : Kirloskar for 750 KVA DG Set complete all as specified and directed.
Replacement of Electronic AVR assembly Complete make : Kirloskar for 100/110/160/750 KVA DG Set complete all as specified and directed.
Replacement of Electronic AVR assembly complete for 30/50/62.5 KVA DG Set complete all as specified and directed.
Replacement of Fan Blade for 100/110/160/750 KVA DG set as per sample complete all as specified and directed.
Replacement of Fan Blade for 30/50/62.5 KVA DG set as per sample complete all as specified and directed.
Replacement of Oil Coolent additive concentrate pack of 10 Ltr suitable for DG Set complete all as specified and directed.
Supply only Distilled water in 5 ltr PVC Container complete all as specified and directed.
Replacement of air filter outer & inner element for 30/62.5/100/110/160/750 KVA D G set as per sample complete all as specified and directed.
Replacement of wiring loom complete all as specified and directed.
Taking out unserviceable alternator from 30/50/62.5 KVA DG set and removing starter and rotor, removing old burnt out winding wire and rewinding the stator of suitable size with super enameled copper wire and insulating materials complete including re-assembling the complete alternator, fixing in position and testing on load complete including replacement of bearing of suitable size – 01 Set complete all as specified and directed.
Taking out unserviceable alternator from 100/110/160/750 KVA DG set and removing starter and rotor, removing old burnt out winding wire and rewinding the stator of suitable size with super enameled copper wire and insulating materials complete including re-assembling the complete alternator, fixing in position and testing on load complete including replacement of bearing of suitable size – 01 Set complete all as specified and directed.
S&F in replacement On load changeover switches, 4 pole, 200 Amp manual changeover in open execution complete all as specified and directed. Make - L&T (Cat No.CO22000OOOA) or equivalent in Havells/C&S as approved by GE.
Supply & Fix in repair Front Mounting add- on aux. Contact Block model - Code -13 100-250V or as per site reqt AF265-40 (1SFC101066M0201), AC 415 V ,50 Hz , 3 phase, 4 pole for contractor of LT panel of AC plant. Make-L&T/Siemens/ABB,
S&F in replacement On load changeover switches, 4 pole, 100 Amp manual changeover in open execution complete all as specified and directed. Make - L&T (Cat No.CO11000OOOO) or equivalent in Havells/C&S as approved by GE.
MAINT OF FIRE ALARM SYSTEM
Replacement of microprocessor based main control panel of 10 zones having provision of indicator for fire alarm, fire, fault,open/short earth circuit complete. Make : SAFE ZONE/APOLLO or equivallent by OEM
Replacement of Zonal Indicator panel for fire alarm system zonal panel of upto 6 zone having provision for indicator fire,fault, open/short earth circuit dulyinterfaced with main control pnel complete Modle SD-1165. Make : Safezone/Apollo
Replacement of Repeater Panel for fire alarm system repeator panel of mann control panel hving provision of Audio Video indicators for fire, faukt, oen/short circuit duly interfaced with main control panel complete. Make : Safezone/Apollo
Replacement of Multi criteria heat cum smoke detector complete. Make : Apollo
Replacement of Response indicator for fire alarm system made of 1.6mm thick CRCA sheet having dual Red LED indicator complete. Make : Safezone.
Replacement of Siren for fire alarm system complete. Make : Safezone.
Replacement of medium intensity hooter for fire alarm system complete. Make : Safezone.
Replacement of manual call points suitable for addressable system duly painted in red colour paint with front glass to be broken in case of fire) complete with test key to check the response with out breaking the glass and die cast aluminium housing with IFD indicator all as specified. Make : APOLLO
Replacement of copper conductor multi stranded armoured cable fixed on wall/ceiling with proper saddles/spacers of size 2 Core 1.5 Sqmm complete. Make : CCI/SUNLIGHT
Replacement of Zone cards, Make : HITESH/GURUTRONIC
Replacement of pillbox complete, Make : MATHS/GURUTRONIC
COMPREHENSIVE E/M MAINT WORKS
Taking down carefully existing point wiring (any type viz. aluminum or copper) with wooden batten/surface PVC conduit (with its fittings)/PVC casing-capping or any other type for light, fan, power point (including switch, socket, ceiling rose, etc.) and making good disturbed surface of wall/ceiling to match with existing surface after necessary rewiring complete all as specified and directed.
Taking down unserviceable sub main wiring including service connections, of any size and any description including conduit pipe and making good disturbed surface of wall/ceiling to match with existing surface after necessary rewiring complete all as specified and directed.
Taking down old unserviceable MCB DB of any size and capacity including wooden boards complete all as specified and directed.
M&L for point wiring for one light / fan / bell point with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in and including non metallic rigid PVC casing capping not less than 25mm base size with all fitting and fixing accessories including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly by suitable lugs, sunken sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators, etc. with 3mm thick laminated hylum sheet cover complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : Wiring to be done as per approved colour code in IE rule.
All as per BOQ item No.138 above, but for one light point controlled by two 2 way switches complete all as specified and directed.
All as per BOQ item No.138 above, but for 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
All as per BOQ item No.138 above, one 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
All as per BOQ item No.138 above, but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination on or 3 pin socket out let 15 amp independent board and provision of 1.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
All as per BOQ item No.138 above, but wiring with 4.0 Sq mm copper cable for 5/15 amp switch socket combination or 3 pin socket out let 15 amp on independent board and provision of 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
M&L for point wiring for one light / fan / bell point with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in & including non metallic rigid PVC conduit (ISI marked) medium grade not less than 20mm diameter with all conduit accessories in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 (except on ceiling for fan point only, surface casing capping will be used in lieu of concealed PVC conduit) including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly, sunk sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators etc. with 3mm thick laminated hylum sheet cover complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : Wiring to be done as per approved colour code in IE rule.
All as per BOQ item No. 144 above, but for 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
All as per BOQ item No. 144 above, one 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
All as per BOQ item No.144 above, but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination on or 3 pin socket out let 15 amp independent board and provision of 1.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
M&L for point wiring for one light / fan / bell point with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in existing concealed conduit including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly by suitable lugs and 3mm thick laminated hylum sheet cover including taking old point wiring (any type without conduit) complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : Wiring to be done as per approved colour code in IE rule.
All as per BOQ item No.151.00 above, but for 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
All as per BOQ item No.151.00 above, one 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
All as per BOQ item No.151.00 above, but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination on independent board and provision of 1.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
All as per BOQ item No.151.00 above, but for two light point controlled by two 2 way switches complete all as specified and directed.
All as per BOQ item No.151.00 above, but wiring with 4.0 Sq mm copper cable for 5/15 amp switch socket combination or 3 pin socket out let 15 amp on independent board and provision of 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way, 5/6 Amps, 230 volt AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR/LEADER/CONA as approved by GE]
S&F Socket outlet multipurpose having provision for 3 pin, 5 Amp and 2 pin, 5 Amp, piano flush type, 230 volt AC complete all as specified and as directed. [MAKE:-ANCHOR/LEADER/CONA as approved by GE]
S&F Switch socket combination, multipurpose, 6 pin, 5-15 Amp, flush type, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR/LEADER/CONA as approved by GE]
S&F Ceiling rose surface bakelite, three terminals complete all as specified and as directed. [MAKE:-ANCHOR/LEADER/CONA as approved by GE]
S&F Bell push, flush type, 5 Amp piano type, 230 volt AC ISI marked with valid CML No complete all as specified and as directed. [MAKE:-ANCHOR/LEADER/CONA as approved by GE]
S&F Switch piano, flush type, single pole, two way, 5/6 Amps, 230 volt AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR/LEADER/CONA as approved by GE]
S&F Bell, electric, single phase, 230 volt, AC ISI marked with valid CML No complete all as specified and as directed. [MAKE:-ANCHOR/LEADER/CONA as approved by GE]
S&F lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings with & including LED lamp white 12 watt retrofit, 230 volts complete all as specified and directed. [MAKE FOR HOLDER:-ANCHOR /LEADER/CONA & LAMP : BAJAJ/PHILIPS/SYSKA all as approved by GE]
S&F ceiling fan regulator electronic step type 240 V, AC 50 Hz single pole, 100 watts flush type, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR/LEADER/CONA as approved by GE]
S&F TPN, 4 way, Distribution board, double door, including fixing and connecting of MCBs/ isolator, ELCBs, etc factory made, confirming to IS: 13032 fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral link and 200 Amps 440 volts rated bus bar. DB shall be semi glossy finished with epoxy polyester based powder paint sprayed and baked at high temperature, between powder painting process the sheet steel having to go through the anti-rust conditioning in not less than seven tank process to ensure smooth finish and protection against corrosive atmosphere. The DB shall be double door type with hinged door with locking arrangement. The DB shall be of same make as MCBs /Isolator. DB shall also be provided with label marking indicating the incoming and outgoing circuits. The DB shall be of IP 43 protection class complete all as specified and as directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE] NOTE:- MCB shall be measured and paid seperatly.
All as per BOQ item No.166.00 above but MCB DB SPN 240 volts 200 amps rated bus bar, 12 way, double door complete all as specified and as directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE] NOTE:- MCB shall be measured and paid seperatly.
All as per BOQ item No.166.00 above but MCB DB SPN 240 volts 200 amps rated bus bar, 8 way, double door complete all as specified and as directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE] NOTE:- MCB shall be measured and paid seperatly.
All as per BOQ item No.166.00 above but MCB DB SPN 240 volts 200 amps rated bus bar, 4 way, double door complete all as specified and as directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE] NOTE:- MCB shall be measured and paid seperatly.
S&F MCB TPN, 415 volts, 10 KA breaking capacity, 'C' curve, of capacity 63 amps complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S&F MCB TPN, 415 volts, 10 KA breaking capacity, 'C' curve, of capacity upto 40 amps complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S&F MCB SP, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 5 to 32 amps complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S&F MCB SPN, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 6 to 32 amps complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S&F MCB SPN, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 40 to 63 amps complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing into rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 20mm external diameter and PVC insulated stranded copper conductor of 2.5 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note: - Two runs of 4.0 sqmm cable, one run of 2.5 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 20mm external diameter and PVC insulated stranded copper conductor of 4 sqmm nominal cross section area as earth wire including taking down old unserviceable sub main wiring complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note: - Two runs of 6.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with four single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 10.0 sqmm nominal cross section area and drawing into rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 25mm external diameter and PVC insulated stranded copper conductor of 10 sqmm nominal cross section area as earth wire including taking down old unserviceable sub main wiring complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note: - Four runs of 10.0 sqmm cable, one run of 10.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
S&F in replacement sheet metal earth plug & socket, single pole and neutral with and including 1no. single pole MCB 20 Amps 240 volts complete all as specified and directed. [Make:-Legrand Cat No. 607841 or equivalent in Crabtree/C&S as approved by GE].
S&F sheet metal enclosure factory fabricated for Multiphase Out going suitable for Mounting MCCB as Incomer of rating 100 Amp Vertical distribution board 4 way with suitable Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified. Cat No - DBVDD04160TAB -MCCB of HPL or Equivalent Model Havells/Legrand/ABB as Approved by GE. ( Note : MCCB & MCB Shall be Measured and Paid Separately )
S&F for MCCB 100 Amp, 16 KA 3 Pole including complete electrical connection by appropriate size of copper lugs complete all as specified and directed by the Engr-in-Charge.
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR-2009 Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by 15mm dia light grade GI pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. NOTE :- (i) The concrete pit shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of GI pipe medium grade for protection of earth wire and 4mm dia earh lead wire upto 7.5 M. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself.
S&F in repairs laminated sheet cover, ISI marked, (Make- Hylem), cut with grooves for mounting of fittings like switches, sockets, fan regulators, etc. including fixing in location with new galvanised screw and cup washer complete all as specified and directed.
S&F in repairs CFL 11 W, 240 V, 50 Hz suitable for 2x11 W surface mounting CFL luminaries complete all as specified and directed. [Make: Bajaj/ Philips/Wipro/Crompton as approved by GE]
S&F in repairs electronic ballast 1 x 11 watt, 240 V, 50 Hz suitable for 2x11 W surface mounting CFL luminaries complete all as specified and as directed. [Make: BAJAJ (Cat No.539315) or equvalent in Philips/Wipro/Crompton as approved by GE]. NOTE:-Ballast without taking down of fitting will be measured under this item.
Taking out u/s CFL lamp 36W from light fittings and S&F LED CFL Lamp 18W , 4 pin type , retrofit complete suitable for surface mounting CFL Luminaires 1X36W or 2X36W, complete all as specified and directed. Make:- Polycab/Syska/CG
Repair/Replacement of us CFL lamp 36W from light fittings, 4 pin typ , retrofit complete suitable for surface mounting CFL Luminaires 1X36W or 2X36W, complete all as specified and directed. Make:- Polycab/Syska/CG
Supply and fixing electronic ballast 36 watt, suitable for 2X36W or 1X 36W surface mounting CFL Luminaires complete all as specified and directed. [Make: BAJAJ/ Philips/Wipro/Crompton as approved by GE].
Taking down u/s light fitting any type and S&F LED 20 W/21Watt tube light fitting (T8 type), including LED retrofit tube 20/21 W one side connection type, 240 v, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, complete with powder coated CRCA decorative patti suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make :-Bajaj ( For Batten Model No. BLRB DB 118 or suitable for mounting T8 LED tube 20 watt and For LED tube Model No. BLRB21WCWc) or C&S cat Part No. LTDC01220WLED/WD (LED battan T8 TARA -M) or Havells (Titania LED tube with Regal batten LED) or equivalent in Philips/ Crompton as approved by GE.
Supply and fixing in replacement electronic ballast 28 watt, suitable for T-5 fittings complete all as specified and directed. [Make: BAJAJ/ Philips/Wipro/Crompton as approved by GE].
Supply and fixing in replacement LED tube rod 28 watt,suitable for T-5 fittings complete all as specified and directed. [Make: BAJAJ/ Philips/Wipro/Crompton as approved by GE].
Supply and fixing in replacement electronic ballast 36 watt,suitable for T-5 fittings complete all as specified and directed. [Make: BAJAJ/ Philips/Wipro/Crompton as approved by GE].
Supply and fixing in replacement tube rod 36 watt,suitable for T-5 fittings complete all as specified and directed. [Make: BAJAJ/ Philips/Wipro/Crompton as approved by GE].
Dismantling of ceiling fans AC single phase 230 volts of sizes 1200mm/1400mm (collected from MES fan store ) any make / model except old vintage, dismantled its stator,rotor, cutting out burnt copper winding and providing new winding with super enamelled copper winding wire existing size including cleaning of slots providing oil impregnated insulation paper or minimax, fibre, insulation in slots and well wraping with cotton tape, bind with cotton thread and varnishing over all with winding varnish as aproved by Engineer - In - chargee cleaning of bearing housing and shaft, replacing spares such as split pins, blade screws etc as required all as specified and directed by Engineer -In - charge.
All as per item no. 193.00 above but for exhaust fan of following sizes :-
400/450mm sweep AC single phase 230/240 volts
300/380mm sweep AC single phase 230/240 volts
230/250mm sweep AC single phase 230/240 volts
All as per item No 193.00 above but for wall fan/padestal fan of any sweep and capacity
S&F condenser carrier clip (PVC) in build connector two way fixed with screw on down rod or housing complete all as specified and directed.
S&F upper set of clips for down rod with rubber Bush (Garari) including set of nut bolts and washer, pin complete all as specified and directed.
S&F rubber bush ( Garari ) for mounted at upper side of down rod clip all as specified and directed
S&F gun metal bush self lubricated, any size ,suitable for ceiling and wall fans complete all as specified and directed
S&F flexible copper conductor stranded 1100 Volt PVC insulated cable twin core twisted 23/0.0076 Sq mm size, complete all as specified and directed.
S&F in replacement Fan condenser, 230 Volts of the following sizes :- [Make: Epcos/Tibcon as approved by GE]
S&F ball bearing of following sizes :- [Make:SKF/NBC/FAG as approved by GE]
NBC/ SKF - 6201 'ZZ' (set of two)
NBC/ SKF - 6202'ZZ' (set of two)
NBC/ SKF - 6203'ZZ' (set of two)
NBC/ SKF - 6204'ZZ' (set of two)
Taking down ceiling fan/wall fan from fan hook and disconnection from ceiling rose and dismantling of ceiling parts i e. down rod and connector/condenser nut bolts, split pins, rubber bush (garari) condenser carrier clip (PVC) in build connector two way complete servicing by cleaning greasing/oiling before in side surface by CTC with sand paper and repair and re - fitted the same position and testing complete all as specified and directed on site. ( Note: - Only rubber packing (garari) condenser, condenser carrier clip (PVC) in build connector two way shall be measured and paid separately)
Taking down Exhaust fan any type and disconnection from ceiling rose and dismantling i.e connector/condenser nut bolts, condenser carrier clip (PVC) in build connector two way complete servicing by cleaning greasing/oiling before in side surface by CTC with sand paper and repair and re - fitted the same position and testing complete all as specified and directed on site (Note: - condenser, condenser carrier clip (PVC) in build connector two way shall be measured and paid separately
Supply and replacement down rod for ceiling fans duly painted with synthetic enameled paint 300 mm long19 mm outer dia with holes on both ends of the rod for connection wire replacement complete.
Supply and replacement down rod for ceiling fans duly painted with synthetic enameled paint 600 mm long19 mm outer dia with holes on both ends of the rod for connection wire replacement complete.
Supply and replacement Exhaust fan blade duly painted suitable for 450 mm/380mm sweep complete all as directed .
Supply and replacement Exhaust fan blade duly painted suitable for 300 mm/230 mm sweep complete all as directed .
S&F in replacement of fan blade suitable for 1200mm sweep ceiling fan complete similar to original make with new screws Complete all as specified and directed by Engr-in-Charge.
All as per item No. 219.00 above but 1400mm sweep.
Supply and replacement outer frame complete with clamps, rubber packing, nut bolts etc & all accessories duly painted suitable for 450 mm /380 mm sweep exhaust fans complete all as directed .
Supply and replacement outer frame complete with clamps, rubber packing, nut bolts etc & all accessories duly painted suitable for 230/300 mm sweep exhaust fans complete all as directed .
Painting of ceiling fan with two coat synthatic enamel paint after surface preparation including Writing/making of MES No size of letters not less than 2.0 CM high and not more than 50 alphabets as approved colour as directed.
Dismantling of cabin fan of any sweep and overhauling complete by means of cleaning of stator, oiling & greasing including replacement of nut and bolt etc and reassembling the same and testing complete all as specification and directed by Engr-in-Charge .
Dismantling of cabin fan of any sweep and rewinding the stator with super enameled copper winding wire of suitable size including greasing, cleaning of all components of fan reassembling , testing, commission complete all as specification and directed by Engr-in- Charge.
Removing unserviceable bearing shaft welding broken area and threading in lathemachine at appropriate size and refixing in ceiling fan any type complete all as specified and directed.
Taking down unserviceable Fresh Air fan and S&F PVC fresh air fan of 300 mm sweep in toilets compete with louvers including all civil work like cutting and making opening in existing wall of toilet etc , including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make:CG/Bajaj/Havells.
S&F in replacement landscaping LED light 9 watt, mushroom shape, integral decorative, LED bollard with IP 65 protection complete all as specified and directed. [Make:-Bajaj (Cat No.BLMC 9W WW LED) or equivalent in Philips/ Crompton/ Havells/ Wipro as approved by GE].
Taking down carefully storage type water heater (Geysers) of any make and any capacity at any height opening for inspection compete Including heating element inner copper tank etc. De-scaling cleaning and re-assembling of Geysers after repairs carrying out and re-fixing in same position (spares as required for repair geyser are measured and paid separately) including making good to walls with CM (1:3) or PCC (1:2:4) and plastering the wall surfaces with CM 1:6 and replacement of old nuts, bolts and rubber gasket etc all as directed by the Engineer-in Charge.
Taking down and Supply and Fixing 1.5 KW capacity Heating Element, Push/ Screw type with ‘O’ ring including making electrical connection complete all as directed by the Engineer-in-Charge.
All as per item No 230.00 above but of capacity 2.0 KW
Supply & Fix in replacement of Geyser assembly suitable for 25 ltr capacity ISI marked including dismantling of old unserviceable geyser assembly complete all as specified & directed.
All as per item No 232.00 above but capacity of geysers 50 litres.
Supply & replacement thermostate suitable for 25/50 Ltr Geyser ISI marked complete all as specified & directed.
Supply & replacement of inner tank made of steel suitable for 25 Ltr geyser including dismantling of old unserviceable inner tank complete all as specified & directed.
Supply & replacement inner tank made of steel suitable for 50 Ltr geyser including dismantling of old unserviceable inner tank complete all as specified & directed.
Supply & replacement outer tank made of steel suitable for 25 Ltr Geyser including dismantling of old unserviceable outer tank complete all as specified & directed.
Supply & replacement outer tank made of steel suitable for 50 Ltr Geyser including dismantling of old unserviceable outer tank complete all as specified & directed.
Supply & replacement bottom cover suitable for 25 Ltr Geyser including dismantling of old unserviceable bottom cover complete all as specified & directed.
Supply & replacement bottom cover suitable for 50 Ltr Geyser including dismantling of old unserviceable bottom cover complete all as specified & directed.
Supply & replacement indicating lamp 230 volts 50 HZ AC suitable for geyser any type (round,squire or rectangular type) any capacity complete all as specified & directed.
Supply & replacement sheet metal enclosure with industrial type 3 pin socket and plug including one MCB single pole 32 Amps 240 volts 50 HZ complete all as specified & directed.
Supply & replacement copper connection 15 mm dia 45 cm long with both side nut complete all as specified & directed.
Supply & replacement PVC connection heavy duty 15mm dia 45 cm long with PTMT nutscomplete all as specified & directed.
Supply & replacement pressure release valve suitable for 25/50 Ltr capacity geyser complete all as specified & directed.
Taking out old U/S voltage stabilizers of capacity 0.5 KVA to 5 KVA from MES store/site and repair the same in MES work shop (if the transformer found burnt, the in same shall be re-winded in the workshop of contractor as directed by Eng in Charge.
Taking out old burnt winding work and re-winded with super enameled copper winding wire (existing size) for 5 KVA voltage stabilizers including all necessary insulating material and testing complete.
All as per item No 247.00 above but capacity of voltage stabilizer 4 KVA/3KVA.
All as per item No 247.00 above but capacity of voltage stabilizer 2 KVA / 1KVA.
Deduct schedule of credit (calculation will be done off line) Rs.94494.00
UMESH ENTERPRISES
RAJPATI CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .