Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC ADARSH COLONY GOLE KA MANDIR GWALIOR MP | GWALIOR | MADHYA PRADESH | 474001 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹22.4 L+₹91,130 (4.24%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹25.6 L+₹4.1 L (19.2%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹26.5 L+₹5.0 L (23.3%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹26.9 L+₹5.5 L (25.4%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | M/S KAPIL CONSTRUCTION CO L8 | anand enterprises L2 | m/s varsha traders L3 | sanjeev enterprises L5 | M/S STEAD FAST L4 | M/s Anupam Construction Co. L9 | SHOURYA ENGINEERING ENTERPRISES L6 | M/S uneversal agency L1 | SIYA ASSOCIATES L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | S&F in repair MCCB, 4 pole, 630 Amps current rating and ultimate breaking capacity ics=Icu =100% 36 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed. | 1 | Each | 28,300 ₹28,300 | 15,000 ₹15,000 Lowest | 18,000 ₹18,000 | 27,000 ₹27,000 | 20,000 ₹20,000 | 30,000 ₹30,000 | 38,664 ₹38,664 | 19,000 ₹19,000 | 28,111 ₹28,111 |
| 2.00 | All as per item here-in-before but MCCB, 4 pole, 400 Amps current rating and ultimate breaking capacity 36 KA. Ics = 100 % of Icu | 2 | Each | 25,800 ₹51,600 | 13,000 ₹26,000 Lowest | 15,000 ₹30,000 | 23,000 ₹46,000 | 17,500 ₹35,000 | 22,500 ₹45,000 | 29,043 ₹58,086 | 15,000 ₹30,000 | 19,111 ₹38,222 |
| 3.00 | All as per item here-in-before but MCCB, 4 pole, 315 Amps current rating and ultimate breaking capacity 36 KA. Ics = 100 % of Icu | 3 | Each | 22,300 ₹66,900 | 11,000 ₹33,000 Lowest | 12,000 ₹36,000 | 21,000 ₹63,000 | 17,200 ₹51,600 | 21,500 ₹64,500 | 28,419 ₹85,257 | 12,000 ₹36,000 | 16,111 ₹48,333 |
| 4.00 | All as per item here-in-before but MCCB, 4 pole, 250 Amps current rating and ultimate breaking capacity 36 KA. Ics = 100% of Icu | 5 | Each | 13,800 ₹69,000 | 8,000 ₹40,000 | 7,000 ₹35,000 Lowest | 13,000 ₹65,000 | 12,500 ₹62,500 | 18,500 ₹92,500 | 25,290 ₹1,26,450 | 10,000 ₹50,000 | 11,111 ₹55,555 |
| 5.00 | All as per item here-in-before but MCCB, 4 pole, 160 Amps current rating and ultimate breaking capacity 36 KA . Ics = 100 % of Icu | 4 | Each | 7,800 ₹31,200 | 5,000 ₹20,000 Lowest | 6,000 ₹24,000 | 7,500 ₹30,000 | 12,000 ₹48,000 | 10,000 ₹40,000 | 12,855 ₹51,420 | 6,000 ₹24,000 | 8,111 ₹32,444 |
| 6.00 | All as per item hereinafter but MCCB, 4 pole, 125 Amps current rating and ultimate breaking capacity .16 KA . Ics = 100 % of Icu | 5 | Each | 7,500 ₹37,500 | 4,500 ₹22,500 | 4,500 ₹22,500 | 6,500 ₹32,500 | 7,000 ₹35,000 | 7,000 ₹35,000 | 6,544 ₹32,720 | 3,000 ₹15,000 Lowest | 3,111 ₹15,555 |
| 7.00 | All as per item here-in-before but MCCB, 4 pole, 100 Amps current rating and ultimate breaking capacity. 16 KA. Ics = 100 % of Icu | 4 | Each | 4,600 ₹18,400 | 4,000 ₹16,000 | 3,500 ₹14,000 | 4,000 ₹16,000 | 6,000 ₹24,000 | 6,800 ₹27,200 | 6,498 ₹25,992 | 2,000 ₹8,000 Lowest | 3,111 ₹12,444 |
| 8.00 | All as per item here-in-before but MCCB, 4 pole, 63 Amps current rating and ultimate breaking capacity .16 KA . Ics = 100 % of Icu | 4 | Each | 3,600 ₹14,400 | 4,000 ₹16,000 | 2,500 ₹10,000 | 3,700 ₹14,800 | 5,000 ₹20,000 | 4,000 ₹16,000 | 6,173 ₹24,692 | 1,500 ₹6,000 Lowest | 3,111 ₹12,444 |
| 9.00 | M&L for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50Mtrs below ground level) connected to GI strip 25×4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm GI tubing medium grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, PCC chamber using PCC(1:3:6) type C-1 using 20mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick CM (1:6) externally up to 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on Electrical plate No.3 of SSR Part-I (2009) and connected to earth test point incl testing and marking Bldg Nos and writing Test Results (in white) on a black painted M.S. Plate (size 300x300x3mm th) duly welded with angle iron of size 40X40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.
Note :- (i) GI strip 25×4mm and GI pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.
(ii) Excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing.
(iii) The rates quoted by the contractor are deemed to be included for PCC chamber and PCC cover as per SSR part-1.- | 12 | Each Job | 4,300 ₹51,600 | 3,800 ₹45,600 Lowest | 5,000 ₹60,000 | 4,500 ₹54,000 | 4,000 ₹48,000 | 5,000 ₹60,000 | 7,500 ₹90,000 | 4,200 ₹50,400 | 5,111 ₹61,332 |
| 10.00 | M&L for preparation of old painted surfaces of LT steel tubular pole/strut, of any description and in any position 9.00/8.50 Mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, GI pipe bracket of street/security light, anti climbing devices etc and providing three Nos radium band strips complete all as specified and directed. | 40 | Each Job | 245 ₹9,800 | 250 ₹10,000 | 350 ₹14,000 | 300 ₹12,000 | 300 ₹12,000 | 200 ₹8,000 | 320 ₹12,800 | 150 ₹6,000 Lowest | 221 ₹8,840 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
30 Jun 2026, 6:00 pmClosed
GE (AF) TA GWALIOR
GE (AF) TA GWALIOR-474020
REPAIR / REPLACEMENT AND MAINT OF LT EXTERNAL ELECTRIC SUPPLY WORKS AND OTHER CONNECTED ITEMS AT EAST AND WEST WING IN TECH AREA UNDER GE AF TECH AREA GWALIOR
2026_MES_770522_1
8900/1668/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Gwalior
Please ref tender documents
7 documents required · 7 mandatory
₹500
GE (AF) TA GWALIOR
₹60,000
Yes
11 Aug 2026
8 Jun 2026
7 Jul 2026
8 Jun 2026
30 Jun 2026
23 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S&F in repair MCCB, 4 pole, 630 Amps current rating and ultimate breaking capacity ics=Icu =100% 36 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed. | 1 | Each | - | - |
| 2 | All as per item here-in-before but MCCB, 4 pole, 400 Amps current rating and ultimate breaking capacity 36 KA. Ics = 100 % of Icu | 2 | Each | - | - |
| 3 | All as per item here-in-before but MCCB, 4 pole, 315 Amps current rating and ultimate breaking capacity 36 KA. Ics = 100 % of Icu | 3 | Each | - | - |
| 4 | All as per item here-in-before but MCCB, 4 pole, 250 Amps current rating and ultimate breaking capacity 36 KA. Ics = 100% of Icu | 5 | Each | - | - |
| 5 | All as per item here-in-before but MCCB, 4 pole, 160 Amps current rating and ultimate breaking capacity 36 KA . Ics = 100 % of Icu | 4 | Each | - | - |
| 6 | All as per item hereinafter but MCCB, 4 pole, 125 Amps current rating and ultimate breaking capacity .16 KA . Ics = 100 % of Icu | 5 | Each | - | - |
| 7 | All as per item here-in-before but MCCB, 4 pole, 100 Amps current rating and ultimate breaking capacity. 16 KA. Ics = 100 % of Icu | 4 | Each | - | - |
| 8 | All as per item here-in-before but MCCB, 4 pole, 63 Amps current rating and ultimate breaking capacity .16 KA . Ics = 100 % of Icu | 4 | Each | - | - |
| 9 | M&L for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50Mtrs below ground level) connected to GI strip 25×4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm GI tubing medium grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, PCC chamber using PCC(1:3:6) type C-1 using 20mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick CM (1:6) externally up to 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on Electrical plate No.3 of SSR Part-I (2009) and connected to earth test point incl testing and marking Bldg Nos and writing Test Results (in white) on a black painted M.S. Plate (size 300x300x3mm th) duly welded with angle iron of size 40X40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.
Note :- (i) GI strip 25×4mm and GI pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.
(ii) Excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing.
(iii) The rates quoted by the contractor are deemed to be included for PCC chamber and PCC cover as per SSR part-1.- | 12 | Each Job | - | - |
| 10 | M&L for preparation of old painted surfaces of LT steel tubular pole/strut, of any description and in any position 9.00/8.50 Mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, GI pipe bracket of street/security light, anti climbing devices etc and providing three Nos radium band strips complete all as specified and directed. | 40 | Each Job | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
tender1668.pdf
Tender Documents • 0.86 MB
BOQ_862876.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .