RequiredExperience with Government Pabx System-EPABX ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) EXTENSION AND TRUNK/JUNCTION EPABX system Implementation Tech nology/Architecture Conventional ( Card/microcontroller based ) Conventional ( Card/microcontroller based )
RequiredHybrid ( Microprocessor based also supporting SIP extension )
RequiredServer Based ( Switching through Call Server Application ) Number of Analogue Extensions/FXS Ports 48 * 1/11 Expandable Upto (TDM/FSX Ports) 128 * Number of Digital Extensions 4 4 Number of Analogue Junction/FXO ports 8 * Number of SIP Extensions NA * SIP Extensions expandable upto NA NA Number of SIP Trunks NA 4
Required8
Required16
Required32
Required64
Required96
Required128
Required256
RequiredNA MAIN DISTRIBUTION FRAME(MDF) MDF(Number of pair) 100 * Integrated Protection Module(IPM) Yes Yes
RequiredNo If YES
Requirednumber of Integrated Protection Module(IPMs) 100 * CARDS CARDS Type of Cards Supported BRI
RequiredPRI
RequiredE1
RequiredE&M
RequiredGSM BRI
RequiredPRI
RequiredE1
RequiredE&M
RequiredRadio Interface
RequiredGSM
RequiredNA Number of Ports per Card Supported 8 1
Required2
Required4
Required6
Required8
Required12
Required16
Required24
RequiredNA GATEWAYS Type of Gateways Supported SIP
RequiredFXO
RequiredFXS
RequiredPRI
RequiredGSM
RequiredE 1
RequiredE&M * Number of Ports per Gateway Supported 8 * CONSOLE Type of Operator Console Key phone based PC based
RequiredKey phone based
RequiredServer Based
RequiredNA Number of Operator Console 1 * SERVER SPECIFICATIONS REQUIREMENTS Total Number of Servers Included in the Supply NA * "Number of Hot Standby Servers out of Total Servers
Requiredincluded in the Scope of Supply" 0 * Server Form Factor NA * Rack Size (RU)/Space Required for each Server NA * Processor Make NA * 2/11 Processor Configuration & Description NA * Total Number of processor NA 1
Required2
Required4
Required6
Required8
Required10
Required12
RequiredNA Number of Redundant Processors Included in the Total Number of Processor NA 1
Required2
Required4
Required6
Required8
Required10
Required12
RequiredNA Number of Cores per Processor NA * Type of RAM NA * RAM Size (in GB) NA 4
Required8
Required16
Required32
Required64
Required128
Required256
RequiredNA T ype of Hard Disk Drive NA * Capacity of Hard Disk Drive (in TB) NA * Hot Swap Components NA Power Supply Unit
RequiredFans
RequiredHDD
RequiredNA Network Interface NA * SOFTWARES Applcation Software Type/Capabilities NA Call Server Software
RequiredHot StandBy Server Software
RequiredUnified Communication Server Software
RequiredNetwork Management Server Software
RequiredNA Type of Licence NA Perpetual
RequiredSubscription Based
RequiredNA Name of Softwares - * Name of the OEM - * OEM Model/Part Number - * Software Description - * Software Version - * Date of Launch of Version - * Free supports/updates during validity of license NA * SOFTWARE FEATURES Analog Extention/FXS ( If Yes
RequiredNumber of Software/Licences shall be Commensurate YES YES
RequiredNO
RequiredNA ( For Convensional PBX ) 3/11 Equal to the Number of Analog Extension/FXS Offered under ""EXTENSION AND TRUNK/JUNCTION"" ) "Digital Extension ( If Yes
RequiredNumber of Software/Licences shall be Commensurate Equal to the Number of Digital Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" YES YES
RequiredNO
RequiredNA ( For Convensional PBX ) "Analog Junction/FXO ( If Yes
RequiredNumber of Software Licences shall be Commensurate Equal to the Number of Analog Junction/FXO Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES
RequiredNO
RequiredNA ( For Convensional PBX ) "SIP extension ( If Yes
RequiredNumber of Software/Licences shall be Commensurate Equal to the Number of SIP Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" NO YES
RequiredNO
RequiredNA ( For Convensional PBX ) "SIP trunk ( If Yes
RequiredNumber of Software Licences shall be Commensurate Equal to the Number of Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" NO YES
RequiredNO
RequiredNA ( For Convensional PBX ) "PRI Trunk ( If Yes
RequiredNumber of Software Licences shall be Commensurate Equal to the Number of PRI Trunk Offered YES YES
RequiredNO
RequiredNA ( For Convensional PBX ) 4/11 under ""EXTENSION AND TRUNK JUNCTION"" )" "Radio Interface ( If Yes
RequiredNumber of Software/Licences shall be Commensurate Equal to the Number of Radio Interface Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" NO YES
RequiredNO
RequiredNA ( For Convensional PBX ) "GSM ( If Yes
RequiredNumber of Software Licences shall be Commensurate Equal to the Number of GSM Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES
RequiredNO
RequiredNA ( For Convensional PBX ) "E1 Trunk ( If Yes
RequiredNumber of Software Licences shall be Commensurate Equal to the Number of E1 Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES
RequiredNO
RequiredNA ( For Convensional PBX ) "E&M ( If Yes
RequiredNumber of Software Licences shall be Commensurate Equal to the Number of E&M Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES
RequiredNO GENERAL FEATURES of EPABX SYSTEM Number of Conference Participants Supported 64 8
Required16
Required24
Required32
Required64
RequiredNA Number of Direct Station Selection Keys per Console 16 * Number of Media Channel/Ports Supported 128 8
Required16
Required24
Required32
Required64
Required128
Required256
Required512
RequiredNA Number of IP-TDM Concurrent Calls(2 NA * 5/11 users per call) Supported Call Buffer Memory System Yes Yes
RequiredNo If Call Buffer Memory Available
RequiredNumber of Records 2000 100
Required250
Required500
Required1000
Required2000
RequiredNA Hot Standby Redundant CPU No Yes
RequiredNo If YES
RequiredNumber of Hot Standby CPU Cards NA 1
Required2
RequiredNA Hot Standby Redundant PSU (Power Supply Unit) No Yes
RequiredNo If YES
RequiredNumber of Hot Standby Redundant PSU Cards NA 1
Required2
RequiredNA Inbuilt Voice Mail for EPABX System No Yes
RequiredNo If Voice Mail Available
RequiredNumber of Voice Mail Channels NA 4
Required8
Required16
Required32
Required64
RequiredNA Available for Voice Mail
RequiredNumber of Hours of Recording NA 4
Required8
Required16
Required32
Required64
Required128
Required256
Required512
RequiredNA Auto Attendant Facility No * If Available
RequiredNumber of Auto Attendant Channels NA * ASMDR/CDR Yes Yes
RequiredNo Voice Logger Inbuilt External Connecting facility Inbuilt
RequiredInbuilt External Connecting facility
RequiredNA If YES
RequiredNumber of Simultaneous Calls that can be Recorded in Voice Logger 64 * Security Feature(for server based) NA * Supported Functionalities (for server based) NA * Supported Codecs NA * Any other features Push Button CLI Phone-48 Nos * SYSTEM/EXTENSION/AT System Features Automatic Route * 6/11 TENDANT CONSOLE FEATURES Selection facility
RequiredDID facility(Direct inward dialing)
RequiredDOD facility(Direct outward dialing)
RequiredDISA facility(Direct inward station access)
RequiredDOSA facility(Direct outwards station access)
RequiredMulti Level Voice DISA facility
RequiredPrivacy of Call
RequiredFacility for connecting recorded voice answering
RequiredASMD R/CDR
RequiredProgrammable class of service for (STD/ISD/LOCAL) dialing as per need
RequiredCaller ID information for both internal and external callers (over Analogue
RequiredISDN PRI)
Requiredunique authorization codes for every users
RequiredAutomatic call back
RequiredCall waiting
RequiredMusic-on-hold facility
RequiredCall budgeting
RequiredLeast cost routing
RequiredMix-mode dialing
RequiredProvision for remote logins
RequiredInteractive Voice Response System(IVRS)
RequiredExtensio n to Extension dialing Extension Features Call forwarding
RequiredConsultatio n Hold
RequiredBrokers Call
RequiredAutomatic call transfer
RequiredConference call
RequiredCall pick up
RequiredCall re routing
RequiredAuto call disconnection
RequiredDynamic STD Lock
RequiredPaging on key phone
RequiredBackground music
RequiredPassword control
RequiredVirtual Telephony
RequiredHowler Tone
RequiredCall parking
RequiredAuto answer/Auto off
RequiredEmergency call facili ty
RequiredMissed/Dialed/Receiv ed Call Lists
RequiredLast Caller Call back
RequiredPassword display suppression
RequiredPersonal * 7/11 Identification Number
RequiredHotline
RequiredPreset Conference Calls
RequiredDirect Call billing in rupees
RequiredCall billing printout
RequiredCalling line ide ntification(CLI)
RequiredRemote Maintenance
RequiredOther Extension features Attendant Console Features Answering an incoming call
RequiredCall queuing
RequiredSerial Call
RequiredCall waiting display
RequiredAutomatic Call Distribution
RequiredCall Hold
RequiredTrunk offering
RequiredNight service
RequiredHead phone connectivity
RequiredOther Attendants console Features Answering an incoming call
RequiredCall queuing
RequiredSerial Call
RequiredCall waiting display
RequiredAutomatic Call Distribution
RequiredCall Hold
RequiredTrunk offering
RequiredNight service
RequiredHead phone connectivity
RequiredOther Attendants console Features Voice Prompts and Announcement No * If yes
RequiredNumber of Levels of IVRS 8 1
Required2
Required3
Required4
Required5
Required6
Required7
Required8
RequiredNA POWER SOURCE Supply Voltage 48V DC 230V AC
Required50HZ
Required48V DC
RequiredNA Provision for Inbuilt Battery Charging Arrangement for providing Battery Backup YES * FCBC YES YES
RequiredNO
RequiredNA If YES
Requiredminimum current Rating of FCBC at chrging voltage of 48V (Ampere) 10A 10A
Required12.5A
Required25A
Required50A
RequiredNA Protection against over current and accidental reversal of polarity on the input side and against over current
Requiredover voltage on the output side YES * OPERATING CONDITIONS Minimum Operating Temperature (Degree C) 0 10
Required5
Required0
Required-5
Required-10 Maximum Operating Temperature (Degree C) 45 35
Required40
Required45
Required50
Required55 Operating Humidity (RH) (% ) 95 80
Required85
Required90
Required95 8/11 TEST REPORT DETAILS AND TESTS TEC approval as per the latest TEC specifications YES * TEC approval Certificate number - * Availability of the test report from Central Government/NABL ILAC acredited lab to prove conformity to the specification including Environmental Test Sequence Yes * Test Report Number and date (not a part of biddable parameter) - * Name and Address of the Test lab(not a part of biddable parameter) - * Test reports consist of verification of all the features & functional parameters & environmental tests Yes * conformity to Dry Heat for 16 hours at maximum specified temperature degree C in accordance with IS:9000/part-3/sectio n-5/1977 latest Yes Yes
RequiredNo conformity to Cold Test for 4 hours at minimum specified temperature degree C in accordance with IS:9000/part-2/sectio n-4/1977 latest Yes Yes
RequiredNo conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH in accordance with IS:9000/part-5/s ection-1/1991 latest Yes Yes
RequiredNo INSTALLATION AND MAINTENANCE Installation and Commissioning With With
RequiredWithout Chemical Earthing to achieve resistance < 2ohm No Yes
RequiredNo 9/11 Recommendation Information regarding Supporting Hardware Required to meet the Performance Capabilities of the System - * OPERATION & MAINTENANCE SUPPORT The scope of supply include one set of operation and maintenance manual for each equipment YES * Operation & Maintenance terminal NA(for conventional EPABX) * Training provided to buyers Yes Yes
RequiredNo If YES
RequiredDetails of training On site training for 3 days On site training for 3 days
RequiredOn site training for 5 days
RequiredNA Packing List - * SERVICES Warranty 1 1
Required2
Required3
Required4
Required5
Required6
Required7
Required8
Required9
Required10 Or higher Recommendation Information regarding Supporting Hardware Required to meet the Performance Capabilities of the System
Required- * Compliance to STC of the Product Yes * * Bold specifications are the golden parameters.