Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC Accepted due to lowest |
| 2 | L2₹1.4 Cr+₹4.3 L (3.26%)Rejected-Finance | ₹1.4 Cr+₹4.3 L (3.26%) | L2 | Rejected-Finance Rejected due to not lowest |
| 3 | L3₹1.5 Cr+₹18.6 L (14.0%)Rejected-Finance | ₹1.5 Cr+₹18.6 L (14.0%) | L3 | Rejected-Finance Rejected due to not lowest |
| 4 | L4₹1.6 Cr+₹23.1 L (17.4%)Rejected-Finance 0 NERTHUA RAEBARELI UTTAR PRADESH 229103 | RAE BARELI | UTTAR PRADESH | 229103 | ₹1.6 Cr+₹23.1 L (17.4%) | L4 | Rejected-Finance Rejected due to not lowest |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not admitted due to not fulfilment of eligiblity criteria |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
29 May 2020, 6:00 pmClosed
COL NK SAH
CWE (AF) LOHEGAON
ADDN/ ALTN TO BUILDING NO P-13 AT 9 BRD UNDER GE (AF) LOHEGAON
2020_MES_331198_1
81782/E8
Open Tender
Miscellaneous Works
Item Rate
365 days
GE (AF) LOHEGAON
Please refer tender documents
5 documents required · 5 mandatory
₹1,000
GE (AF) LOHEGAON
₹2.2 L
Yes
14 Jul 2020
4 Mar 2020
1 Jun 2020
4 Mar 2020
29 May 2020
4 May 2020
Amount
B/R WORK
Dismantling of Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engr-in-charge
M&L Anodised aluminium snap grid frame work for false ceiling of grid size 605 x 605 mm all arrangements for hanging using 6mm thick GI wires complete all as specified and directed by Engr-in-charge
M&L for Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) 600 x 600 mm fixed to aluminium grid frame all as specified and directed by Engr-in-charge
Supply & Fix 5 mm thick ESD flooring (EPU Coating system) and to carryout third party tests for resistivity of flooring under permissible limits, as per requirement of user complete all as specified and directed by Engr-in-Charge.
Taking down plaster on brick or stone wall including racking out joints hatching for key scrubbing down with water etc complete all as specified and directed by Engr-in-Charge.
Demolition of brick work/stone work/Block masonary built in cement mortar complete all as specified and directed by Engr-in-Charge.
M&L for brick work with sub-class 'B' bricks, straight or curved on plain to any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed by Engr-in-Charge.
M&L for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm width of type C1 1:3:6 using 20mm graded aggregate and setting in mortar 1:6 , complete all as specified and directed by Engr-in-Charge.
M&L for rendering 10 mm thick in CM 1:6 on broken chajjas /facia/walls/ceilings etc, area n. exc 3 sqm each patch (in repairs) , includings finishing to match with existing surfaces complete all as specified and directed by Engr-in-Charge. .
M & L for rendering 10mm thick in CM 1:6 finished even and smooth w/o using extra cement with thin layer of sagol finished complete all as specified and directed by Engr-in-Charge.
Material and labour for 15 mm thick rendering in cement mortar (1:4) on fair face of brick or concrete surface finished even and fair complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new plastered/unplastered surfaces and applying three coats of whte wash on walls complete all as specified and directed by Engr-in-Charge.
Material and labour for applying two coats of Cement Base Paint over a coat of Chalk whiting on walls including preparation of new or previously untreated surfaces complete all as specified and directed by Engr-in-Charge. .
Complete removal of existing treatment and Material and labour for applying two coats of Plastic emulsion on Surfaces of any description over 10cm girth or width, not otherwise described complete all as specified and directed by Engr-in-Charge.
Material and labour for applying two coats of Plastic emulsion on Surfaces of any description over 10cm girth or width, not otherwise described complete all as specified and directed by Engr-in-Charge.
Taking down shutters of any description exc 1 sqm but n. exc 2 sqm each complete all as specified and directed by Engr-in-Charge.
All as per item No 17 above here in before but each not exceeding 1Sqm each complete all as specified and directed by Engr-in-Charge.
Taking down & refixing the shutters exc 1 Sqm but not.exc 2.00 Sqm each in same opening each complete all as specified and directed by Engr-in-Charge. .
S & F pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, locks, strike plate etc complete and the size of frame is 105 x 60 mm complete all as specified and directed by Engr-in-Charge.
S & F flush shutters water proof BWR grade solid core construction with block board core and ply wood face panel commercial type both sides 30mm thick complete all as specified and directed by Engr-in-Charge.
Taking down chowkats or frame n.exc 1.50 sqm each (without taking off shutters from the frame) for PVC door and frame complete all as specified and directed by Engr-in-Charge. .
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing as directed by Engr-in-charge (Rajeshree or equivalent) complete all as specified and directed by Engr-in-Charge.
S&F Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of ms tubes for top &bottem rails, ms frame shall be covered with heat moulded plain colour PVC 'C' channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour pvc sheetfor top rail ,lock rail, &bottem rail, on either side & as gap insert for top rail , panneling of plain colour pvc sheet to be fitted in the ms frame welded /sealed to the stiles & rails with suitable pvc sheet beading, &jointed together with solvent cement suppling & fixing in the frame at site as per spacification &drawing complete all as specified and directed by Engr-in-Charge. .
S&F 100 mm long butt hinges, medium weight, and cold rolled mild steel complete all as specified and directed by Engr-in-Charge. .
S&F 150 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed by Engr-in-Charge. .
S&F 200 mm long Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and directed by Engr-in-Charge. .
S&F 125 mm extruded aluminum alloy handles, cast type, anodized complete all as specified and directed by Engr-in-Charge.
S&F 125 mm Mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed by Engr-in-Charge. .
S&F 300 mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed by Engr-in-Charge.
M & L for PCC 1:3:6 type CO using 12.5 mm graded aggregate as in filling of pressed steel frame chowkats complete all as specified and directed by Engr-in-Charge.
S & F galvanised mild steel wire cloth 0.45 mm nominal dia of wire and average width or aperture 1.40mm and fixed with tinned tackles or galvanished wire complete all as specified and directed by Engr-in-Charge.
S&F in repairs for GI wire cloth of 0.56 mm nominal dia of wire & 1.18 mm avg width of aparaturre fixed with wooden beeds complete all as specified and directed by Engr-in-Charge.
S & F sheet glass ordinary quality 3mm thick glazing with oil putty in squares n. exc 0.5 sqm in each pane complete all as specified and directed by Engr-in-Charge.
All as per item No 34 above but of frosted glass complete all as specified and directed by Engr-in-Charge.
Taking down chowkats or frame exc 1.50 sqm but n.exc 4 sqm each (without taking off shutters from the frame) complete all as specified and directed by Engr-in-Charge.
S&F Powder Coated Anodised aluminium frame for doors, windows, ventilators and Partition with one or more rebates including jointing cleat for fixing etc complete all as specified and directed by Engr-in-Charge.
S&F Powder Coated Anodised aluminium Sliding Door, window and ventilator shutters, without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, roller and mortise lock etc. complete all as specified and directed by Engr-in-Charge.
S&F Powder Coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed by Engr-in-Charge.
S & F Sheet Glass, Ordinary quality 5 mm Thick including necessary rubber beading complete all as specified and directed by Engr-in-Charge. .
S&F in repairs 12 Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with /rubber beading to Aluminium framework in Partition or Wall Panelling complete all as specified and directed by Engr-in-Charge.
M&L Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed by Engr-in-Charge.
M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete FE209(Gde E 165) complete all as specified and directed by Engr-in-Charge.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engr-in-Charge.
Refixing (labour only) Pre-painted galvanume aluminium zinc coating GI bashed corrugated steel sheeting 0.50mm th of any colour in roof covering/clading of wall , fixed with self tapping screw complete all as specified and directed by Engr-in-Charge.
S&F Pre-painted galvanume sheet 0.50 mm th plain/corrugated/semicorrugated sheet in ridge hipvalley gutters drip and straight flashing (length or girth as fixed) with grade of zinc coating 275 gm/sqm complete all as specified and directed by Engr-in-Charge.
M&L wind ties for roof including securing bolts and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engr-in-Charge.
S & F Rolled sections as in Columns, Vertical posts etc; fixed with angle cleats or other connecting plates Fe 290 (Gde E-165) complete all as specified and directed by Engr-in-Charge.
M&L two coats of synthetic enamel painting over a coat of red oxide primer on new steel surfaces of any description over 10 cm width or girth complete all as specified and directed by Engr-in-Charge.
M&L for Reinforced cement concrete 1:2:4 type B1 (nominal mix) slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-in-Charge.
M&L formwork to soffits suspended slabs as roof slabs , floor slabs,landings and similar work , not exe 200mm thick (horizontal or sloping) complete all as specified and directed by Engr-in-Charge.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for fair finished concrete complete all as specified and directed by Engr-in-Charge. .
M&L for mild steel TMT bar 10mm dia and over, cut to length,bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with including mils steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
M&L for TMT bar 8 mm and over upto and incl 10mm bar cut to length,bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with including mils steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
M&L for Complete removal of existing treatment of wall and appling 2 coat of cement paint over one coat of primer with alkaliresistant priming paint complete all as specified and directed by Engr-in-Charge. .
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and directed by Engr-in-Charge. .
M&L Granite 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms, urinal partition and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engr-in-Charge.
Taking up GI water tubing 15 mm bore from trenches/wall including all fittings, complete all as specified and directed by Engr-in-Charge.
All as per item No 58 above but 20 mm bore complete all as specified and directed by Engr-in-Charge. .
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thick above or below ground level complete all as specified and directed by Engr-in-Charge. .
Material and labour for providing 75 mm thick PCC (1:3:6) type C2 using 40 mm graded aggregate as in Plinth protection finished the surface even & smooth with out using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for PCC (1:2:4) type B1 using 20 mm graded aggregate (25 mm thick) as in levelling course for tiling in flooring complete all as specified and directed by Engr-in-Charge.
Material and labour for screed bed or bedding layers 15 mm thick in cement mortar (1:6) for laying floor finishes complete all as specified and directed by Engr-in-Charge.
Material and labour for Non - skid Ceramic Coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and directed by Engr-in-Charge.
Machine cut kota stone slab flooring 20-25mm thick over & incl 15 mm thick in CM (1:6) cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engr-in-Charge.
Labour only for Kota for mirror Polish and treating the surface with beeswax polish complete all as specified and directed by Engr-in-Charge.
Material and labour glazed ceramic tiles of size 300mm x 200 mm x 6 mm thick coloured tiles on vertical surfaces set and jointed in neat cement slurry @ 3 Kg/Sqm and pointed in white or coloured cement to match the existing surface over and incl 10mm thick backing coat in cm 1:4 complete all as specified and directed by Engr-in-Charge. .
Dismantling water tank and removing Exc 500 & n Exc 1000 ltr water tank complete all as specified and directed by Engr-in-Charge.
S&F 500 ltrs capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed tap) hoisted and fixed in position complete all as specified and directed by Engr-in-Charge.
S&F 1000 ltrs capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed tap) hoisted and fixed in position complete all as specified and directed by Engr-in-Charge.
S&F 15mm ball brass valves high pressure with polythene flot and flynut completescred for iron pipes or brass ferrule and fix complete all as specified and directed by Engr-in-Charge.
S&F 20mm ball brass valves high pressure with polythene flot and flynut completescred for iron pipes or brass ferrule and fix complete all as specified and directed by Engr-in-Charge.
S&F GI tubing medioum grade with all fittings fixed to walls or laid in floors 15 mm bore complete all as specified and directed by Engr-in-Charge. .
-Ditto- all as per item No.73 above, but fixing only old GI tubing complete all as specified and directed by Engr-in-Charge. .
S&F GI tubing medioum grade with all fittings fixed to walls or laid in floors 20 mm bore complete all as specified and directed by Engr-in-Charge.
-Ditto- all as per item No.75 above, but fixing only old GI tubing (20 mm bore) complete all as specified and directed by Engr-in-Charge.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern),white including fixing bolts, flush pipe, Plastic water closet seat, closed pattern with reccessed bottom, and cover and mild steel chromium plated or aluminised hinging device and etc complete all as specified and directed by Engr-in-Charge.
S&F, as in repair, 10 ltrs capacity PVC valve less syphonic action type, low level flushing cistern, white with inlet, ball valve float and handle including brackets complete all as specified and directed by Engr-in-Charge.
Supply and fix, bowel urinal flat back of size 465mm x 355mm x 265mm (minimum), white, with grating and union for discharge pipe, (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinals again complete all as specified and directed by Engr-in-Charge.
Supply and fix, in repair, vitreous china wash basin, white flat back size 550 x 400 mm, excluding taps, waste chain, plug and porcelain stopper but including brackets, cutting for and pinning in ends of bracket or erecting stand complete all as specified and directed by Engr-in-Charge.
S&F 15 mm bore pillar taps fancy type (long neck) cast copper alloy with capstan heads chromium plated screwed down high pressure with or without letter hot or could with long screwed and shanks and fly nuts screwed for iron pipes complete all as specified and directed by Engr-in-Charge.
S&F in repairs for 15 mm bore stop valves cast copper alloy screwed down high pressured with butterfly handle screwed both ends for iron pipes fancy type choromium plate (concealed type) complete all as specified and directed by Engr-in-Charge.
S&F in repairs for 15 mm bore angle stop valves of PTMT colour high pressure screwed for iron pipe and fixed (minimum weight 15mm 90gms) complete all as specified and directed by Engr-in-Charge.
S&F in repairs for 15 mm bore push tap any colour high pressure PTMT screwed for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
S&F in repairs for bib cock 15 mm bore fancy type chromioum plated with long shank & casptan head complete all as specified and directed by Engr-in-Charge.
M&L for 75mm cast iron nahani trap including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed by Engr-in-Charge.
M&L for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engr-in-Charge.
Supply and fix ,Towel rail 450 mm long of PTMT fixed with and incl chromium plated brass screws and wooden/ plastic cleat ( min weight 170 gms) complete all as specified and directed by Engr-in-Charge.
S&F LPDE waste pipes of 32mm bore pressure rating 6 Kgf/Sqcm for wash hand basin, complete all as specified and directed by Engr-in-Charge.
S&F PVC connection 15mm dia sizes with PTMT nuts of length 450 mm complete all as specified and directed by Engr-in-Charge.
S&F soap dish stainless steel complete all as specified and directed by Engr-in-Charge.
S&F in repairs High density polythene pipe(HDPE)of pressure rating 6 Kgf /Sq cm fixed comp to wall or laid in tranches or under floors.(50 mm bore) incl all fittings complete all as specified and directed by Engr-in-Charge.
Demolition and breaking up CI/PVC drain pipes 50 to 110 mm complete all as specified and directed by Engr-in-Charge.
S & F PVC (SWR) pipes 75mm dia in any length with rubber ring joints fixed to walls complete all as specified and directed by Engr-in-Charge.
S & F PVC (SWR) pipes 110mm dia in any length with rubber ring joints fixed to walls complete all as specified and directed by Engr-in-Charge. .
S & F PVC (SWR) bend 110mm dia with access door complete all as specified and directed by Engr-in-Charge.
S & F PVC (SWR) bend 75mm dia with access door complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) junction double, (Double T) equal or unequal 110mm Dia with access door complete all as specified and directed by Engr-in-Charge. .
S&F PVC (SWR) junction double, (Double T) equal or unequal 75mm Dia with access door complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) branch piece double, (Double Y) equal or unequal 110mm Dia with access door complete all as specified and directed by Engr-in-Charge. .
S&F PVC (SWR) branch piece double, (Double Y) equal or unequal 75mm Dia with access door complete all as specified and directed by Engr-in-Charge.
S & F PVC (SWR) gully trap 110 mm dia fixed in cement concrete and providing connection upto 1st manhole with PVC pipe complete all as specified and directed by Engr-in-Charge.
S & F PVC (SWR) P traps bore 125/110 mm dia complete all as specified and directed by Engr-in-Charge.
S&F S&F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engr-in-Charge.
AC WORK
Supply, installtion commissioning & testing of VRF inverter series latest technology microprocessor based control air conditioning system including outdoor units, indore casette type 4 way units, refrigrent heavy duty copper piping with insulation, drain water piping remote control units, having echo friendly refrigrent. Suitable size copper heavy duty armoured electric and control cables & suitable electric panel with all fittings & fixture, Grills, Receiver Kits, MS on site fabricated supports/structures, cable tray with supports/rod, nut bolts, washers etc complete all as specified and directed by Engr-in-Charge. Note:- (i) Size of Room (30x49x12 feet0 - 02 Nos (ii) Min Capacity reqd 24 HP (2x12 HPW) (ii) All other accessories reqd at site shall be provided by the contractor as specified by OEM and directed by Engr-in-Charge. (iv) VRF system has to maintain temp 23+30C in all weather (v) Rates quoted shall be deemed to be inclusive of the necessary parts & accessories has recommended by the OEM & Engr-in-Charge. Make- OGENERAL/BLUESTAR/HITACHI/DAIKIEN
Supply, Installtion, Commisionning and testing of air shower for 2 persons with internal size of 1100x1100x2100 mm mde out of CRCA sheet, pretreated stove enamelled having face velocity 6000 feet/min + 20 feet, operation time (adjustable) 0 to 9.990 seconds, 3 filter, wahsable, prefitters glass plated non-woven fabric filter having 99.99% efficiency down to size 0.3 microns particles airflow control solid state control unit, blower assembly centrifugal lubricated bearing type ISI marked assembly, illumanations using flourescent light elumination greater than 800 lux on work table noise level less than 60 DB,addon sequential teature operation by doormate magnetic switch suitable for operation at 220 to 230 volts 50 Hz single ph, frequency 50/60 Hz all as specified and directed by Engr-in-Charge. Make Purafil
M&L for carefully taking out existing split type Acs up to 1.5 TR cap and refixing including filling refrigerant gas to new location including new copper tubing with insulation and power cord as reqd at site including necessary core cutting in stone masonery wall complete all as specified and directed by Engr-in-Charge
Supply, installtion commissioning & testing of commercial Air curtain, unit for prevention of dust and conditioned air losses, single phase, 20V 50HZ made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS-CRC 18 gauge square perforated suction grills, Aluminium alloy fans and single phase lectric motor, nozzles etc complete with fittings and accessories so as to produce 1-1.5 m/sec air velocity at floor level for door opening 52"x84" complete all as specified and directed by Engr-in-Charge
E/M WORK
Taking down the existing surface batten type point wiring of aluminium for Light, fan, Sockets, power sockets, stair case light point complete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc as directed by Engr- in charge.
Taking down the sub main wiring of any dia / sq mm on teak wood batten / PVC conduit GI earth wire all as directed and making good disturbed surfaces for wall, floors etc as directed by Engr- in charge.
Taking down carfully by unscrewing the unserviceable DB Boxes, MC distribution boards SP & TPN with porcelain cutouts etc all as directed and making good disturbed surfaces for wall, floors etc as directed by Engr- in charge.
Taking down carefully ceiling fan, dismantling the blades from fans and disconnecting ceiling cable ends & removing fan & blades and depositing to AGE E/M store complete as directed by Engr- in charge.
Taking down existing tube light fittings and disconnecting connection cable ends complete from ceiling rose /juction box etc complete as directed by Engr- in charge
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board ) ISI Marked (IS:14772) for housing switches / sockets all a specified and directed (a )One light point controlled by one switch.
(b) One E xhaust Fan or wall mounted fan point controlled by one regulator/switch
(c) One 3 pin socket 5 A on independent board.
Material and labour for providing point wiring with two runs of 2.5 Sqmm multi stranded copper conductor Flame retardant Low Smoke (FRLS) PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core copper stranded Flame retardant Low Smoke (FRLS) PVC insulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board ) ISI Marked (IS:14772) for housing one 15 A Switch / sockets etc complete as directed by Engr- in charge.
S&F Vertical double door Distribution board TPN 4 way 200 A rated busbar consisting of MCCB. 100A 10KA - 1 NO etc complete as directed by Engr- in charge . Note - Rate in deemed to be inclusive of 4 pole 16 kA 100 Amp MCCB Make- L&T, ABB,Legrand
Supply and fix sheet metal enclosure MCB DB double door SPN 12 way 230 V with neutral link and with 200 A bus bar etc complete as directed by Engr- in charge
Supply and fix sheet metal enclosure MCB DB double door SPN 8 way 230 V with neutral link and with 200 A bus bar etc complete as directed by Engr- in charge
Supply and fix sheet metal enclosure MCB DB double door SPN 4 way 230 V with neutral link and with 200 A bus bar etc complete as directed by Engr- in charge
Supply and fix MCB SPN 40 Amp,10 KA 230 volt 'C' series etc complete as directed by Engr- in charge
S&F MCB SP 240 volt 6 to 32 A 10 KA 'C' series etc complete as directed by Engr- in charge
Supply and fix switch piano flush type 5 A one wayetc complete as directed by Engr- in charge
Supply and fix switch socket combination multipurpose 5 Pin 5 Amps.etc complete as directed by Engr- in charge
Supply and fix switch socket combination multipurpose 6 pin 6/16 Amps etc complete as directed by Engr- in charge
Supply and fix ceiling rose surface type bakelite/PVC three terminal 65x50mm etc complete as directed by Engr- in charge
Supply and fixing LED mirror light fitting 09 Watt including electrical connections etc complete as directed by Engr- in charge
Supply and fix Energy efficient recess mounted LED luminaire 34 Watt suitable for 2x2 grid in white colour with flat diffuser and lumen constant of 3300/4000K colour temperature with current electronic connections etc complete as directed by Engr- in charge
S & F wall mounting fans 230 volts 400mm sweep swing etc complete as directed by Engr- in charge
Supply and fix heavy duty metal body incl clamps, lovers, exhaust fan 380mm sweep, 1400 RPM, 230 volts etc complete as directed by Engr- in charge Note- Necessary wall cutting for fixing the E/ fan is deemed to be incl in the unit rate quoted
M&L for sub main wiring with two runs of single core 4.0 Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 650 / 1100 V grade with colour code and one run of 2.5 Sq mm ( 22 / 0.3 mm ) single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor including PVC casing & caping all as directed.. ( Note :Two runs of 4.0 Sqmm copper cable,one run of earth wire of 2.5 Sqmm copper cable shall be measured & paid as one length.) etc complete as directed by Engr- in charge
Material and labour for supply, installation, testing and commissioning of chemical earthing maintenance free earthing based on 6 mtr, set of three pure copper electrode pipe of 76 mm bore(ID) with wall thickness of 3 mm, interconnected in grid with distance of each electrode 2.5 mtr minimum including excavation/Earthwork in rock soil, duly fixed with connector at top connection of copper strip 20x 3 mm ( strip in pipe type electrode )and copper pipe electrode shall be filled with MFC for improvement of conductivity of electrode, 120 KGS approx of BFC shall be filled around the copper pipe elecrode ,including providing FRP pit cover of size 250 mm at top ,330 mm at bottom and 260 mm in height capable to withstand minimum 2 ton driving load.Rate included for testing,commisioning including checking of earth continuity and earth result complete all as specified and directed. Vendors are bound to get earthing result less than or upto1 Ohm with grid of earthings. Copper strip required to interconnection of earth pits in grid must be laid 01 ft below the ground level and the same must be treated with chemical (BFC) if required to achieve resistance value.Rate is included for boring of earthing in any type of soil/rock upto 200 mm bore.Continuity of good earth resistance shall maintained upto 1 year and testing will be carried out by MES authority and contractor's rep after completion.Copper strip must be connected with copper pipe electrode and other joints with exothermic joints complete all as directed and specified by Engr-in-charge Note:- (i) Earth strip for grid network and from top connector of electrode to test point and further connection to LT panel/AF equipments/ for grid of earthing shall be measured and paid separately. (ii)Any additional electrodes/material required to get result less than 01 Ohm will be provided by the contractor without any extra cost.
Material and labour for supply, installation, testing and commissioning of chemical earthing maintenance free earthing based on 6 mtr, set of two GI pipe electrode pipe of 76 mm bore(ID) with wall thickness of 3 mm, interconnected in grid with distance of each electrode 2.5 mtr minimum including excavation/Earthwork in rock soil, duly fixed with connector at top connection of copper strip 20x 3 mm ( strip in pipe type electrode )and copper pipe electrode shall be filled with MFC for improvement of conductivity of electrode, 120 KGS approx of BFC shall be filled around the copper pipe elecrode ,including providing FRP pit cover of size 250 mm at top ,330 mm at bottom and 260 mm in height capable to withstand minimum 2 ton driving load.Rate included for testing,commisioning including checking of earth continuity and earth result complete all as specified and directed. Vendors are bound to get earthing result less than or upto 3 Ohm with grid of earthings. Copper strip required to interconnection of earth pits in grid must be laid 01 ft below the ground level and the same must be treated with chemical (BFC) if required to achieve resistance value.Rate is included for boring of earthing in any type of soil/rock upto 200 mm bore.Continuity of good earth resistance shall maintained upto 1 year and testing will be carried out by MES authority and contractor's rep after completion.Copper strip must be connected with copper pipe electrode and other joints with exothermic joints complete all as directed and specified by Engr-in-charge Note:- (i) Earth strip for grid network and from top connector of electrode to test point and further connection to LT panel/AF equipments/ for grid of earthing shall be measured and paid separately. (ii)Any additional electrodes/material required to get result less than 05 Ohm will be provided by the contractor without any extra cost.
Supply & Lay copper strip 20 x 3 mm with saddle and fixing screws etc for roof conductor and down conductor barried in ground & wall/ floor all as specified and directed by Engineer-in-charge.
Supply & fix aluminium strips 25x3 mm on insulator 15 BMD type 'T' placed not more than 50 cm apart all as directed by Engr - in - Charge . ( Note : Porcelain insulators with nuts bolts and Acrews will measured and paid separatly under relavent items)
S&F DMC porcelain insulators of size 20x3 mm T type with nut bolts / screws for fixing of copper strips on walls etc all as specified and directed by Engineer-in-charge.
S&F test point terminal block made out of gun metal or phosphorous bronze size 150x150x75 mm depth , drolled , cutting upper & lower portion for incoming & outgoing including double insulators two coat of synthic enamel paint etc complete as directed by Engr- in charge.
Supply and fix air termination rod single pointed aluminium 12 mm dia & 300 mm long etc complete as directed by Engr- in charge
S&F GI earth strips 32 mm x 6 mm fixed on insulator fixed on wall using cadmium plated screw or laid in tranches etc complete as directed by Engr- in charge
Supply and errect vertically GI steel tubing 40 mm bore medium grade complete with fittings for raising height of existing air termination rods to site present light requirements etc complete as directed by Engr- in charge
M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32x6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified. Note:- (i) Venders are bound to get resistance value result less than 5 Ohm for single earthings. Any additional work and material required to achive the required result is included in the cost quoted by the tenderer.(ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with M&L for black cotton soil 1 cum.
Supply install, factory testing and commissioning of distribution transformer step down, outdoor type copper wounded having primary side of HT three phase 11 KV & secondary for 3 phase 433 volts, 4 wire 40 hertzs capacity of 160 KVA with the following specification:- (i) No load voltage ratio-11/433KV (ii) Nos of phase-three (iii) Type of cooling - ONAM (iv) Frequency-50Hz (v) Vector group -DYN 1 (vi) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing (vii) Oil level guage indicating oil level minimum and maximum (viii) Lifting Lugs (ix) Rating and terminal marking plates (x) Dehyderation breathing device which would not permit ingress of moisture rain water and insects (xi) Drain cum sampling value (3/4" nominal thread) preferably steel with plug (xii) Thermeter pocket (for transformers of rating above 25 KVA)” etc etc complete as directed by Engr- in charge
Supply and fix steel tubular swaged poles erected to truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap, bolts, nuts & screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II type 410-SP-55 (11m long) including drilling of holes of required size for fixing of cross arms, panting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint internally & portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately and marking pole No. with black paint at suitable height etc complete as directed by Engr- in charge
Supply and fix gang operated air break switches 12 insulators mounted on MS Channel with operating mechanism worked from ground level suitable 11000 volts, 200 Amps including GI pipe handle clamps bolts, nuts, jumper wire connecting with stranded conductors complete with locking arrangements etc complete as directed by Engr- in charge
M&L for cross arms , bracings supports clamps and back plates fabricated from structural steel section including nuts bolts , washers welding , bending cold or hot ,drilling holes for bolts in any shape or size as indicated or directed as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide zinc chrome primer etc complete as directed by Engr- in charge
S&F lightning arrestor non linear resister type (Surge) suitable for 11000 volt grade conforming to IS-3070 Part-I with discharge capacity 5 kilo Amps including stranded coloured sleeved jumper connection with PG clamps mounted on steel mounting fabrication of MS clamps, bolts, nuts, washers etc complete as directed by Engr- in charge
Supply & fixing pin type, porcelain, vitreous, white, brown or green insulator includingone galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade etc complete as directed by Engr- in charge
S & F Disc type insulator, porcelain, vitreous145 mm high and 255mm dia ball and socket type, white, brown or green :Single disc assembly for 11000 VOLTS etc complete as directed by Engr- in charge
Supply, laying and testing cable XLPE insulated screened PVC bedded, GI steel strip or wire armoured, electric power cables (heavy duty) earthed with standard aluminium conductor, 11000 volts grade of size 3 core 185 Sqmm etc complete as directed by Engr- in charge
Supplty and fixing cable jointing kit for 11 KV grade cable for outdoor termination heat shrink type earthed complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm etc complete as directed by Engr- in charge
Supply, laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified of size 185 sqmm 3.5 core etc complete as directed by Engr- in charge
Supply, laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified of size 95 sqmm 3.5 core etc complete as directed by Engr- in charge
Supply, laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified of size 25 sqmm 4 core etc complete as directed by Engr- in charge
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole etc etc complete as directed by Engr- in charge (a) soft/loose soil
(b) Hard/dense soil
Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil etc complete as directed by Engr- in charge
Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point etc complete as directed by Engr- in charge
Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 15 cm( for HT cable) and 10 cm (for LT cable) after laying and stretching jointing and testing the cable etc complete as directed by Engr- in charge [Note : Measuremenet will be done after punning]
Supplying and laying unreinforced precast concrete cable cover, class HV, type 1 flat of size 300mm x180mm x 40mm placed perpendicular of the cable etc complete as directed by Engr- in charge
Supplying and laying un-reinforced precast concrete cable cover, class LV, type I, flat of size 250mm x 150mm x 40mm placed perpendicular of the cable etc complete as directed by Engr- in charge
M&L for cement concrete (1:4:8) type D2 in foundation filling and mass concrete using 40mm graded stone aggregate for pole/stay foundation etc complete as directed by Engr- in charge
M&L for cement concrete (1:3:6) type C2 in foundation filling and mass concrete using 40mm graded stone agg for pole/stay foundation etc complete as directed by Engr- in charge
UG cable route indicator made out of 100 mm dia MS plate with 20mm dia 50cm long MS bar as legs for writing HT cable fixing with and including necessary PCC 1:2:4 in grouting route etc complete as directed by Engr- in charge
S & F MCCB, 4P, 200 Amp, 25 KA with sheet metal enclosures etc complete as directed by Engr- in charge
S&F on poles aluminum conductor steel reinforced (ACSR), stretched on HT poles without any kink and bends complete including fixing to insulator with copper binding wire and coloured sleeved jumper connection with PG clamps all as specified and directed. Note: The size of conductor shall be squarel/weasel/Mink
M & L for reinforced concrete pipes class NP -3, of size 100 mm bore for protection of HT/LT cables under road crossing, in trenches etc complete as directed by Engr- in charge
Cutting of existing road not exc 1.5 mtr in depth and not exceeding 1.5 mtr wide including black top sub base and WBM, well ramming in layers with watering after laying of RCC /GI pipe under road making good in all respect to match with the existing surface all as directed by E-in-charge.
S/F GI tubing 50 mm dia light grade in trench or on wall for the protection of UG cable etc complete as directed by Engr- in charge
S/F GI tubing 80 mm dia light grade in trench or on wall for the protection of UG cable etc complete as directed by Engr- in charge
M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32x6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified. Note:- (i) Venders are bound to get earthing result upto 5 Ohm for single earthings. Any additional work and material required to achive the required result is included in the cost quoted by the tenderer.(ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with M&L for black cotton soil 1 cum.
M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to copper earth strip 20 x 3 mm by means of bolts, nuts, checknuts & washers of copper and connecting to test point , providing charcoal and common salt ,all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including copper earth strip 20 x 3 mm with GI protection pipe of 25 mm medium grade 7.5 meter long, etc complete all as specified. Note-- (i) Vendors are bound to get earthing result upto 3 Ohm with single earthing. Any additional work and material required to achive the required result is included in the cost. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with M&L for black cotton soil 1 cum.
S & F GI earth continuity conductor or main earthing lead of size 32x6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required etc complete as directed by Engr- in charge
S & F copper earth continuity conductor or main earthing lead of size 20x3 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required etc complete as directed by Engr- in charge
Supply and fix in replacement of drop out fuse unit expulsion type for outdoor air break gang operated switch, single pole, mounted on and including insulators for 11 KV working pressure, fixed to and including MS channel with nuts, bolts, washers etc, synthetic bounded fuse carrying tube complete with line taps and suitable for current carrying capacity upto 25-50Amps and connected with suitable size of ACSR conductor as jumper between GOD and DO fuse, with 11 KV HT PVC sleeve, with all fittings/accessories etc, including taking down of only 3 fuses etc complete as directed by Engr- in charge
Supply, laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified of size 35 sqmm 3.5 core..” etc complete as directed by Engr- in charge
M/S V C SHETH
KSP ENTERPRISES
M/s Kirti Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .