Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.2 LAccepted-AOC | L1 | Accepted-AOC Accept | |
| 2 | L2₹40.4 L+₹18,660 (0.46%)Rejected-Finance | L2 | Rejected-Finance High Rates |
Tender Value
₹39.6 L
EMD Value
₹79,220
Closing Date
9 May 2022, 6:00 pmClosed
GE (MCTE) Mhow
GE (MCTE) Mhow (MP) 453441
SPECIAL REPAIR TO BLDG NO WB-175 (JCOS MD ACCN) INCL CERTAIN B/R MISC WORK AND OTHER ALLIED SERVICES UNDER GE(MCTE) MHOW
2022_MES_518136_1
GE (MCTE)/MHOW/02(T) OF 2022-23
Open Tender
Civil Works
Works
180 days
GE (MCTE) Mhow
As Per Tender Document
8 documents required · 8 mandatory
₹500
Yes
GE (MCTE) Mhow
₹79,220
Yes
4 Jul 2022
13 Apr 2022
11 May 2022
13 Apr 2022
9 May 2022
26 Apr 2022
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing debrish and rubbish off the premises and stacking serviceable tiles.
M&L for Virified Ceramic tiles 10 mm thick light shade (square/ rectangular) polished, area of each tiles exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6
All as item No.02 above but on vertical surfaces such as in skirting incl including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6
All as item No.05 above but on vertical surfaces such as in skirting incl including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles complete all as specified and directed.
M&L for glazed coloured ceramic tiles, first quality (or approved class, colour and design/shade) of 350x 250x 7 mm/ 450X 300X 7mm thick in vertical surfaces, as in dado/skirting etc set & jointed in neat cement slurry & pointed in coloured cement to match with coloured tiles, over and including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles complete all as specified and directed.
Taking down chowkats or frame of any description exc 1.5 Sqm each and n.exc 4Sqm (without taking off shutters from the frames) & remove off the premises complete all as specified and directed.
Taking down chowkats or frame of any description n.exc. 1.5 Sqm each (without taking off shutters from the frames) & remove off the premises complete all as specified and directed.
S&F Pressed steel door frame for single door, size 105 x 60mm x 1.5mm thick with one rebates incl necessary fixing lugs, hinges, lock strike plate, holdfast (size 25mm x 3 mm) of length 30 cm) etc, complete all as specified and as directed.
S&F Pressed steel door frame for single door, size 165 x 60mm x 1.5mm thick with one rebates incl necessary fixing lugs, hinges, lock strike plate, holdfasts (size 25mm x 3 mm) of length 30 cm) etc, complete all as specified and as directed.
S & F 35 mm thick Flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides complete all as specified and directed.
S & F 35 mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass gauge etc with cut and mitred beads for securing glass etc size of member of shutter as specified in SSR Pt-1 section 8 and clause 8.24 (a)
S&F solid PVC door frame of size 50mm x 47 mm with a wall thickness of 5 mm made out of exruded 5 mm single side prelaminated PVC foam sheet, mitre cut at two corners and jointed with 2 Nos of 150 mm long brackets of 15 mm x 15 mm M. S square tube. The two vertical door profiles are to be reinforced with 19 x 19 mm M S square tube. The door frame shall be fixed to the wall using 65/100 mm long M.S screws through the frame by using PVC fasteners. A minimum of 4 Nos of screws to be provided for each vertical member etc. complete as per manufacturers specification and direction of Engr-in-Charge and showe as drawing as Sl Page No.178 of SSR Part-II.
S&F factory made Factory made solid panel PVC door shutter 30 mm thick both side pre-laminated consisting of frame made out of M.S. tube of 19 gauge thickness and size of 19mm x 19mm for style and 15 x 15 mm for the top and bottom rails, MS frame shall have a coat of steel primers of approved make and manufacture. MS frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50mm shall be flat and 20 mm shall be tappered in 45 degree angle on either side forming styles and 5 mm thick 95mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rails. Top bottom and lock rails shall be tapered on both sides to form lock rails. Top bottom and lock rails shall be provided either side of the panel. 10 mm (5mm x 2) thick 20 mm wide side cross PVC sheet be provided as gap insert for the top rail and bottom rail. Panelling of 5 mm thick both side PVC sheet to be fitted in the MS frame welded/ sealed to the styles and rails with 7 mm (5 mm + 2 mm) thick x 15 mm wide PVC sheet beading on inner side and joined togehter with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' channel using PVC solvent adhesive etc. complete as per direction of ENgr-in-Charge. manufacturer's specification & drawing (for W.C and bathroom door shutter. all as specified and directed by Engr-in-Charge and showe as drawing as Sl Page No.175 of SSR Part-II.
M & L for PCC 1:2:4 type B0(12.5 mm graded) aggregate for filling in pressed steel door framed.
S&F 200 mm size aluminium, anodised barrel tower bolt of extruded section.
S&F 150 mm size aluminium, anodised barrel tower bolt of extruded section.
S&F 300mm length, aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy.
S&F120mm size, butt hinges, heady weight, cold rolled mild steel.
S&F 150 mm size extruded aluminium alloy handles, fabricated type.
S&F 125mm size extruded aluminium alloy handles, fabricated type.
M&L for Preparation of new wooden surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specifed and directed.
S&F powder coated aluminium sliding window three track with two glass shutters using 5 mm thick glass tinted modi guard and one shutter with stainless steel wire gauge wire cloth 0.31 mm nominal dia of wire and width of aperature 1.61 mm using aluminium powder coated section aluminium cleat, PVC track, bearing, handle, lock, rubber beading etc complete fittings all as showe on TD drawings of Zonal drowings.
S&F powder coating anodised aluminium ventilator, half portion of the ventilator covered with 5.5 mm thick frosted glasses and half portion fittted with frosted louvers and outer side fitted with mosquito proof galvanised wiremesh including removing old steel ventilators incl finishing the demolished surfaces with rendering 10-15 mm thick CM 1:4 of fair finish including 02 coats of cement based paints with primer incl all fittings, accessories etc all as specifed and directed by Engr-in-Charge all as showe on TD drawings of Zonal drowings.
M&L for 5.5 mm thick sheet glass ordinary quality in panes exc 0.50 sqm each fixed with & including rubber gasket in aluminium frame work complete all as specified and directed (For items except Sl. Items No.24 & 25 above).
S&F in repairs 18 mm thick factory made PVC sheet one side pre-laminated sheet ktichen cabinet shutter. The 18mm thick sheet shutter bent at 90 degree and finish all edges at level for marking edge lipping bending for 0.5 mm thick PVC sheet lipping at all four edges using bonding tape etc complete all as per specified and directed by Engr-in-Charge and as per manufacturers specification.
S & F in repairs factory made PVC shelf/ partition of required size consisting of panel of 18 mm thick required size consisting of panel of 18 mm thick celuka PVC ply and for supporting the hold of shelf /partition and shall be provided 3 edges in size 18mm x 18 mm as per required lenght the front side of the edge visible in the front of the shelf/partition to be edge lipped by 18mm widht x 1 mm thick PVC sheet of density 600 kg/cum manufactured by ISO 9001-2015 Certified Company, using solvent cement etc.
S & F Continuous (piano) hinges, 30 mm Width of flaps (when open) in mm brass, bright finish or electrogalvanised Continuous (piano) hinges, bright finish or electrogalvanised
S&F 50 x 15 mm size magnet door catcher for closing for PVC door shutter complete all as specifid and directed.
S& F 100 mm size MS mat/glossy finish handle complete all as specfied and directed.
Demolition of cement concrete (unreinforced) of any description as in ground floors and pavings not exceeding 15cm thickness (above or below ground floors) complete all as specified and directed.
M&L for broken stone or bounders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a floor/true surface.
M&L for 25mm PCC 1:2:4 Type B-0 (Using 12:5mm stone agg) as in base floor with water proffing compound of Asian Paint, Pidilite, Dr Fixit or equivalent, complete all as directed and specified.
M&L for water proofing treatment to sunken surfaces of the slab in following sequences :- (with 5 Years Gaurantee and Security Deposit there of)
Slope correction by using M-20 (Nominal Mix) concrete minimum 25mm thickness at one end and a slope of 1:20 by using 12.5 mm graded stone aggregate with integral water proofing Chemical PIDI PROOF-LW mixed in proportion 200ml /50 Kg cement of DR Fixit of Pidilite Industries Ltd or STP No 1 (liquid) of STP Ltd in proporation 200ml/ 50 Kg cement or equivalent as per manufacturer instructions complete.
PCC padding with cement concrete 1:1.5: 3 type A 0 (using 12.5 mm graded stone aggregate) 25mm thick with integral water proofing compound "Dr Fixit" manufactured by M/S Bouchemic or equivalent as per manufacturer instructions complete.
Vertical sides plastered in CM 1:3, 15mm thick with WPC @ 3% by weisht of cement and 72 hours testing for water tightness by ponding of water complete.
Application of two coats water proof coats black manufactured by M/S Dr fixit or equivalent as per manufacturer instructions all over and testing again for water tightness by ponding of water for 72 hours complete.
S&F in repair vitreous china sqatting pan (orissa pattern) size 580mmx440mm, white with integral foot rest, any pattern including provision of cement concrete bedding in PCC (1:3:6) Type C1 (excluding fulshing cistern and flush pipe) with S or P trap, Fixed in repairs, complete all as specified and directed
S&F in repairs low level Flushing cistern 10 ltr capacity, PVC valveless syphonic action type, white with inlet, ball valve, float valve and handle, flush pipe, incl brackets and flushing pipe fixed in repairs complete all as specified and directed
S&F in repairs vitreous china, white, wash hand basin, flat back size 550x400mm including MS brackets including cutting for and pinning in, including waste pipe complete all as specified and directed.
S&F in repair 15mm size PVC connections internally threaded with PVC washer, PTMT nuts of length 450mm complete all as specified and directed.
S & F in repairs Stop/angle cock 15 mm bore cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions.
S&F in repair chromium plated brass wall mixer 3-in-1 fancy type with provison for both hand shower and overhead shower complete with wall flange (without hand &over head Shower screwd down for15 mm GI bore pipe complete all as specifed and directed.
S&F in repair chromium plated brass Central hole basinmixer (Hot and cold) without popup waste system complete screwed down for15 mm GI bore pipe complete all as specifed and directed.
S&F in repair 20mm dia brass chromium plated tubular towel rails, D type, 60cm long between flanges, complete all as specified.
S&F in repair 125 mm size Brass Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specifed and directed.
S & F in repairs Corner Glass Shelf of Size 320 x 320 mm with Silver chromium finished border Oval Range premium quality all as specifed and directed by Engr-in-Charge.
S & F in reparis Stainless Steel Soap Dish fixed to wall all as specified and directed by Engr-in-Charge. Make : Prayag Cat Part No BA-15S or equivalnet.
S&F in repair SS towel ring brass chromium plated with glossy finishes as approved.
S&F in repair sinks made of stainless steel kitchen sink, size 610 x 460 x 203 mm incl waste coupling, waste pipe and all necessary fittings complete all as specifed and directed. Make Prayag Cat Part No (Overall size is 610 x 460x 203 mm) and (bowl size is 560 x 405 x 203 mm) or equivalent approved.
S&F in repair 15 mm bore bib tap cast copper alloy (fancy type), chromium plated, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as directed.
S & Fixed in repair Flexible Kitchen Mixers with Flexi Spout, highly durable, food class material, eco friendly, anti-rust, Colour -blue premium quality all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for re fixing complete all as specifed and directed.
S&F laying and testing for 15 mm bore GI tubing medium grade galvanised steel tubing including all fittings such as union, reducer, sockets, reducing bends elbows tee, checknuts, caps, plugs etc fixed to wall and ceilling or laid in floors complete all as specifed and directed.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
S & F 20 mm bore of tube medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors.
Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys, scrubbing down with water etc, complete all as specified and directed.
M&L for Rendering 15 mm thick on fair faces of concrete/ brick surfaces in cement mortar 1:4 mixed with water proofing compound as per manufacturer's instruction, finished fair and even without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid for seprately as supply only under respective item of sch A.
Supply only Liquid water proofing compound ISI Marked (used 200 ml per bag of cement) complete all as specified and directed.
M&L for preparation of newly surfaces of walls and applying two coats with Premium Acrylic Smooth exterior paint and including priming coat of exterior primer and incl one coat wall putty as per manufactor's instructions complete all as directed by Engr-in-Charge. (Note : painting will be done by brush/ spray/ roller of building upto the height G+2) all as directed by Engr-in-Charge).
M&L for complete removal of exisitng surfaces of walls and applying two coats of Premium Acrylic Smooth exterior paint and including priming coat of exterior primer and incl one coat wall care birla white putty as per manufactor's instructions complete all as directed by Engr-in-Charge. (Note : painting will be done by brush/spray/ roller of building upto the height G+1) all as per directed by Engr-in-Charge).
M&L for Rendering 15 mm thick on fair faces of concrete/ brick interior surfaces in cement mortar 1:6 as per manufacturer's instruction, finished fair and even without using extra cement complete all as specified and directed.
M&L for preparation of new surfaces of plastered of walls and applying Two coat of distemper oil emulsion incl priming the surface and incl 1 coat wall care birla white putty all as directed by Engr-in-Charge.
M&L for preparation of complete removal of existing treatment of walls and applying Two coat of distemper oil emulsion incl priming the surface and incl wall care birla white putty all as directed by Engr-in-Charge.
M&L for Rendering 5 mm thick on fair faces of concrete/ brick interior ceiling surfaces in cement mortar 1:3 as per manufacturer's instruction, finished fair and even without using extra cement complete all as specified and directed.
M&L preparation of newly plastered surfaces of ceiling and applying Two coat of distemper oil emulsion incl priming the surface and incl 1 coat thick ceiling birla white putty all as directed by Engr-in-Charge.
Taking down old curtain rods/ drapery rods of any description and S&F 25 mm Stainless Steel Curtain rod with premium quality including brackets and other accessories complete all as specified and directed.
S & F PVC size 110 x 110 mm Nahani Trap all as specfied and directed.
S&F Brass Bottle Trap 300 mm (12") Designer wall connection pipes and wall flange complete all as specified and diretced. Make-Prayag cat No BEA-28 or equivalent approved make by GE.
S&F Granite 20 mm thick green (of any type) work (table rubbed and polished) in steps, jambs, pillars, table top for wash basin, urinal partition, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
Demolition of brick or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone works and precast concrete articles, complete all as specified and directed.
M&L for Brick work with sub class B bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 Complete all as Specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description in any position not otherwise specifically provided for and removing demolished materials to a distance exceeding 250 Mtr complete all as specified and directed.
M & L for RCC type B-01:2:4 (12.5mm graded stone aggt) for shelves supports on walls complete all as specified and directed.
M&L for use and waste form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work for fair finished surfaces of concrete complete all as specified and directed.
M&L for mild steel TMT bars 10 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed.
Dismantling of cast iron, SGSW, PVC or reinforced concrete drain pipes jointed in neat cement mortor and taking out of trenches or floor or wall if required.
S&F PVC (SWR) pipe 75 mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive fixed to wall with iron cleants etc complete all as specified and directed.
S&F PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive fixed to wall with iron cleants etc complete all as specified and directed.
S&F in repair PVC (SWR) bend/shoe 75 mm bore, any radius as required and jointed with approved adhesive and fixed to floor complete all as specified and directed.
S&F in repair PVC (SWR) Tee, Reducer/ junction (single T) equal or unequal 75 mm bore, any radius as required and jointed with approved adhesive and fixed to floor complete all as specified and directed.
S&F in repair PVC (SWR) bend/shoe 110 mm bore, any radius as required and jointed with approved adhesive and fixed to wall complete all as specified and directed.
S&F in repair PVC (SWR) Tee, Reducer/ junction (single T) equal or unequal 110 mm bore, any radius as required and jointed with approved adhesive and fixed to wall complete all as specified and directed.
S&F Grating 100 mm dia of CP with or without hole complete all as specified and directed.
Demolition of stone slab and tiles, interlocking paver block laid bedded and pointed in any mortor of any description or thickness in floor complete all as specifed.
M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 15 mm thick screed bed in CM 1:6
M & L for Machine cutKota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 10mm thick back coat in CM (1:4)
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framed work and similar works complete all as specified and directed.
M & L for Cutting holes in brick walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortor 1:3 or cement concrete 1:2:4 Type B-1, depth of embedded portion of holdfasts exc. Half brick but not exc. One brick from the face of the jamb intl the wall.
M & L for two coats of synthetic enamel paint on surface of any description over 10 cm in width or girth not otherwise described incl preparation of new steel surfaces.
M&L for taking down/dismantling of existing roof treatment of any description such as PCC Padding/ Coba treatment/ mud phuska/Lime conc, Old APP membrance roof treatment etc terracing including screed bed etc. Hessian base felt/tar felt etc. (any type and thickness) complete all as specified & directed.
M&L for Removal of demolished materials to a distance exceeding 250 Mtr but not exceeding 500 Mtr and deposting where directed at a level n.exc 1.5 m above the starting point, complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on roof surface including mixed with WPC as per manufacturer's instruction's and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid for separately as supply only under respective item of sch 'A'.
Supply & providing water proofing roof treatment with polymeric standard water proofing membrane, Aquaflex manufactured by M/s Pidilite, manufactured by STP TEXAS Ltd/ Hyperplas manufactured by IWL Ltd having 10 years gaurantee for water tightness complete all as specified and described as under:- (a) Preparation of RCC roof surface and applying one coat of polymeric modified bitumen 85/25 @ 1.2Kg/Sqm over a coat of polymeric primer @ 0.30 Kg/sqm including cleaning surface all as per manufaturer's specification complete all as specified and directed. (b) Supply & providing water proofing with 3 mm thick APP polymeric proofing membran (centre core shall be 150 GSM, weight not less than 4 kg /sqmtr) of film centre core including coating the surface with compatible primer and torch application of membrane with 10cm overlaps as required thereof, complete all as specified and directed (c) Aluminium bituminous paint @1.10 Kg/Sqm shall be applied over the APP membrane surface.NOTE:- The work of water proofing treatment shall be got executed throughh expert team of manufacturers or authorised applicator of manufacturer.
Demolition of cement concrete (unreinforced) of any description as in ground floors and pavings exceeding 15cm thickness (above or below ground floors) complete all as specified and directed
Disconnecting & taking down existing water tank of capacity exc 500 liter and not exc. 1000 liter and removing from site complte and S&F rotational moulded polyethylene water storage tanks 1000 lts capacity (cylindrical vertical with closed top) hoisted with and including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or for brass ferrule and fixed in position all as per SSR Part-I complete all as specified & directed.
S&Fixed in repair of Size Stainless Steel Kitchen Plate Rack includings arrangement/ joining of all accessories and hanging to wall for utensils for kitchen size 31"x24"x10" complete as as specifed and directed. Make Prayag Cat part No P-346 or equivalent approved.
S&F stainless steel shelf closing hinges 75 mm size for PVC door shutters complete all as specified and directed.
S&F 50 x 15 mm size magnet door catcher for closing for PVC door shutter complete all as specifid and directed.
S& F 100 mm size MS mat/glossy finish handle complete all as specfied and directed.
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples
S&F in repairs Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples
M & L in fixed in repairs 18/19 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work
M&L for 75mm thick cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection finished even and fair incl cutting joints and filling with bitumen and sand mixture complete all as specified and directed.
M&L for Machine coloured Rubber Moulded pressed precast concrete interlocking paver block any shape and size colour rubber finishes in top over confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigments over and including 30-40 mm thick sand cushoining
M & L for excavating hard/dense soil in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surfaces.
M & L for PCC Type C2 1:3:6 (40 mm graded aggregate) in foundations, filling and mass concrete.
S&F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws complete all as specified and as directed.
S & F mild steel work as in main and cross beams, hip and jack rafters, purlins, vertical sections, where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe 410-W (Gde-E 250 (quality A) all as specifed and directed by Engr-in-Charge.
S & F mild steel compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, incuding all lattice bars, stiffeners, gussets plates etc. conforming to Fe 410-W (Gde-E 250 (quality A)
S & F mild steel works in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment with riveted, bolted or welded attachment. conforming to Fe 410-W (Gde-E 250 (quality A)
M & L for preparation of new iron or steel surfaces of any description, over 10cm in width or girth, not applying two coats of synthetic enamel paint over a coat oxide zince chrome primer complete otherwise described
M&L for 100 mm thick PCC type B2 (1:3:6) using 40 mm graded stone aggregate) in subbase, path, paving, hardstanding etc, complete all as specified and as directed by Engineer-in-Charge.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings.
M & L for Demolition of ends for damaged portion of chajja /facia portion scrafying or removing Old loose dirt of cement concrete and removing of Old rusted reinforcement, lathing/welding of new reinorcement for damaged portion, fixing of 0.71mm dia wire netting of galvanised steel wire of size 12mm mesh fixed with tinned tack of wire stable for damaged portion and applying in CM (1:3) with level plaster for width of facia /Chajja exc 10mm and n.exc 60mm finished even and smooth without using extra cement and including necessary use and waste of form work and concerting with PCC (1:2:4) type B-0 using 25mm graded stone agg mixed with Dr fixit concreting bonding solution as per manufacturer Instruction for required places, height of the bldg up to third floor from the above ground level for work all as specified and directed.
M & L for RCC 1:2:4 type B-1 (Using 20mm graded crushed stone aggregate) as in Patch work for certain places of Roof slab, facia, Chajja with necessary form work and the height of the bldg up to third floor from the above ground level for work all as specified and directed. (Note Rate will be include for reiforcement also)
S & F in repair concealed CP brass stop cock 20 mm with flange. Make Prayag cat part No 7120 of equlvalent approved.
Taking down carefully copper/alluminium point wiring (light, fan, sockets or power) complete including all fittings and fixtures such as switches, sockets, ceiling roses, pendens, regulators, light fittings etc, removing materials to store for taking credit and making good disturbed surfaces complete all as specified and directed.
Taking down carefully copper/aluminium sub-main wiring any type and making good the disturbed surface of walls and floors etc all as directed by Engr-In-Charge.
Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M No III Mhow complete all as specified and as directed.
Taking down carefully TPN DB/SPN DBs/sheet metal earth plug socket any size and any type including MCBs any type and making good the disturbed surface of walls and floors etc all as directed by Engr-In-Charge.
Taking down carefully light fitting any type for refixing OR taken in schedule of credit all as specified and as directed.
Taking down existing geyser of any capacity after disconnecting all necessary electrical and water supply connections and deposit to MES store yard of AGE E/M No III Mhow complete all as specified and as directed.
Taking down existing single phase electric energy meter of any capacity after disconnecting all necessary electrical connections and re fixing after work complete all as specified and as directed.
Taking down existing old unserviceble LT UG/ service cable of any descrition and size complete all as specified and directed.
M&L for Point wiring with 1.5 Sqmm (nominal cross sectional area), single core, PVC insulated with multistranded PVC unsheathed FR LSH copper conductor cable in and including rigid non- metallic PVC concealed conduit of suitable size medium grade ISI marked complete, including one continuity earth wire of PVC insulated, unsheathed 1.5 Sqmm (nominal cross sectional area) FR LSH copper conductor connected to all fittings, common earth and connected to earth dolly including modular metal flush box, modular cover plate and modular cover frame of suitable size all fittings and accessories and making good disturbed surface of walls and floors etc. complete all as specified and directed for the following:- Make of cable :- Havells/ Finolex/ RR Kabel Ltd/ L&T Make of PVC Conduit (FRLS) :- Presto Plast / Finolex / Jindal / Asian / AKG
(a) One light/ fan/ bell controlled by one, one way switch 5/6 Amps
(b) One light / fan /bell controlled by one, two way switch 5/6 Amps
(c) One 3 pin, 5/6 amps socket outlet point on independent board controlled by one, one way 5/6 amps switch
(d) One 3 pin, 5/6 amps socket outlet point on capital bold controlled by one, one way 5/6 amps switch
M&L for Point wiring with 2.5 Sqmm (nominal cross sectional area), single core, PVC insulated with multistranded PVC unsheathed FR LSH copper conductor cable in and including rigid non- metallic PVC concealed conduit of suitable size medium grade ISI marked complete including one continuity earth wire of PVC insulated, unsheathed 2.5 Sqmm (nominal cross sectional area) FR LSH copper conductor connected to all fittings, common earth and connected to earth dolly for one three pin 15/16 amps socket out-let point on an independent board including modular metal flush box, cover plate and cover frame of suitable size incl taking down carefully copper/ alluminium power point wiring switches, sockets, and making good disturbed surface of walls and floors etc. complete all as specified and directed Make of cable :- Havells / Finolex / RR Kabel Ltd. / L&T Make of PVC Conduit (FRLS) :- Presto Plast / Finolex / Jindal / Asian / AKG
S&F of Ceiling rose three terminals surface bakelite type, AC, 50 HZ, 230V
S&F modular switch 1 way 6 A, 1 module complete all as specified and directed.
S&F modular switch 2 way 6 A, 1 module complete all as specified and directed.
S&F modular socket 6 Amps 2/3 pin combined 2 module complete all as specified and directed.
S&F switch modular type 16 A, 1 module complete all as specified and directed.
S&F socket modular type multipurposes 6/16 A, 2 module complete all as specified and directed.
S&F bell push flush type, 5 amp as directed by Engr-in-Charge.
S&F lamp holder insulated body with back plate for batten fittings complete all as directed.
S&F Buzzer Ding Dong AC 230 Volts Single pole complete all as directed.
Supply and fixing 20W LED 6500K lights fitting Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient with three core flexible copper conductor cable of suitable size from ceiling rose complete with all connected accessories all as specified and directed. Make : Havells LHEXACP7UN1W020 or equivalent make of Bajaj/ Philips/ syska/ Crompton as approved by GE.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. all as specified and directed. Make : Havells/ Bajaj/ Philips/ syska/ Crompton
Supply and fix in repairs Wall light fittings suitable for & including LED bulb of 7 watt, including connection with all necessary fixing accessories complete all as specified and directed by Engr-in-Charge. Make : Havells Cat No. LHDL06160099 or equivalent in equivalent in Bajaj/ Philips/ Crompton.
Supply and fix LED bulb of 7 watt, Of base B-22, cat part no LHLDBWHB4L8R007, lm 700, col tamp 6500 K suitable for fixing in lamp holder. (Make : Wipro /philips/ havells)
S&F(in replacement) MCB DB SPN 8 way double door with 200 Amps rated bus bar, 230 volts, 50 Hz complete all as specifed and directed. Make : Indo-Asian cat part No 810321 or equivalent make in Bajaj/Philips/Crompton.
Supply and fixing (in replacement) 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 32 Amps and current carrying capacity in the MCB DB complete with connection testing and commissioning. all as specified and directed. Make : L&T/ Havells/ scheider/ Indoasian.
Supply and fixing (in replacement) 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. Make : L&T/ Havells/ schider/ Indoasian.
M & L for sub main wiring with 02 runs of 6 sqmm main wire along with 01 run of 06 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC concealed/ surface conduit (medium grade) wherever necessary with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same & taking down complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length. Make of cable:- Havells / Finolex / RR Kabel Ltd. / L&T Make of PVC Conduit( FRLS):- Presto Plast / Finolex / Jindal / Asian / AKG
All as per item No. 147 here in above but with 2 runs of 4 sqmm main wire along with 01 runs of 2.5 sqmm earth wire.
S&F replacement of exhaust fan, steel body AC single phase 230 volt of size 380 mm sweep complete with blade, frame and louvers all as specified and directed incl making/alteration of hole wherever necessary making good disturbed surface, painting to match with existing surfaces. complete all as specified and directed. Make : Havells/ Polycab or equivalent in Crompton/ Almonard
Supply & fix plastic body exhaust fan, AC single phase 230/ 240 V of size 250 mm sweep with louver, white in colour including cutting of wall and duly connection with copper wire from ceiling rose etc complete all as specified and directed. Make : Havells Model Ventil Air-DX White or equivalent in Crompton/ Almonard
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and directed by Engr-in-Charge.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.necessary electrical connection complete all as directed by Engr-in-charge. (Make : Havells, Model - Puro plus or equivalent)
M&L for Replacement of Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level connect to galvanised earth lead wire of 4.0 sqmm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length including connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150 mm c/c both ways etc complete all as shown in electrical plate No 5, connected to earthing test point complete including testing on completion all as specified.
Supply, laying and testing and commisioning cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core laid in pipes, trenches/ducts, on poles complete all as specified and directed .
Supply, laying and jointing GI pipe 'light grade' 50 mm bore in trenches/under floors or roads/ along poles/ on wall incl clamps for protection of cables incl fittings complete all as specified and directed.
Excavation in trenches not exc. 1.5m wide and not exc 1.5m deep in hard/dense soil and getting out complete all as specified and directed by Engr-in-Charge.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed.
Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed.
M&L for filling approved fine river sand in trenches as cable cushion to the full width of excavated trench, under and over cable complete all as specified and as directed. (Note : Punned thickness of sand shall be measured)
M&L for bricks slightly over burnt (kiln burnt), modular bricks, best quality, locally available, laid flat, dry, laid in trenches along the length of cable transvarsally with width equal to length of brick for cable protection all as specified and as directed.
S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. all as specified and directed. Make: Havells/ CG/Philips/Bajaj
(Ser No 42 contd.) Incoming: MCCB 100 A, 4 pole, 25KA-1 No. including CTs, Digital Ammeter, ASS, Digital Volt meter, VSS, Phase indicating lamps & control fuses/MCBs etc. Bus Bar: Copper strip busbar rating 250A of size for Ph 12 x 10 mm, N&E 12 x 5mm and short circuit capacity 30ka, with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 05 Nos Outgoing: Separate cubical chamber with a cable alley not less than 300 mm width for installation/connecting the following switch gear: (i) MCB, 40A DP amps, 240 volts, ‘C’ curve, 10 KA - 07 Nos (ii) MCB, 10A DP amps, 240 volts, ‘C’ curve, 10 KA - 01 Nos (iii) Fixing only 1phase serviceable existing electric meter- 06 Nos (obtained from item No 7)
sabir and brothers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .