| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | L1 | Accepted-AOC lowest bidder for the work | |
| 2 | L2₹8.9 L+₹45,550 (5.41%)Rejected-AOC 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L2 | Rejected-AOC Other than the lowest bidder |
Tender Value
Refer Docs
EMD Value
₹20,200
Closing Date
13 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander Works Engineer Bhopal
Headquarters Commander Works Engineer Bhopal Military Engineer Services SI Lines Bhopal-462 001
REPAIR AND RENEWAL OF E AND M ITEMS AND ALLIED WORKS AT DHANA MIL STN UNDER AGE (I) DHANA
2021_MES_421389_1
83621/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Dhana
As per tender documents
7 documents required · 7 mandatory
₹500
AGE(I) Dhana
₹20,200
Yes
18 Mar 2021
11 Feb 2021
15 Mar 2021
11 Feb 2021
13 Mar 2021
1 Mar 2021
60 days
Amount
Disconnecting distribution transformer outdoor type 11 kV /415 volts having capacity 25 kVA to 250 kVA, lifting the core and winding using triploid and chain pulley, taking out HT/ LT spindle with bushing, draining of oil, cleaning yoke, winding core, spindle, bushing, replacement of defective parts with providing new cork sheet gasket parking 5 mm thick, assembly, stage inspection and testing the repaired transformers for all the routine tests as per IS 2026 (Part 1): 2011 with latest amendments. Note: - (a) The spare parts excluding nuts, bolts, washer shall be measured and paid for separately (e) The said transformer shall be repaired in reputed workshop as decided by the AGE(I). (b) Transportation charges for transportation of transformer from site to workshop and after repair, workshop to site shall be borne by the contractor and cost thereof shall be deemed to be included in the unit rate quoted for this item. (c) Testing of transformer after repair shall be carried out as per IS 2026 (Part 1): 2011 and the cost of testing shall be deemed to be included in unit rate quoted against this item.
M & L for rewinding of coils on primary side of transformer of any capacity using proper size copper DPC wire having class "F" insulation as per existing size and turns including connected minor insulation materials suitable for HT coil of 11 kV/ 415 V transformer complete all as specified and as directed.
M & L for rewinding of coils on secondary side of transformer of any capacity using proper size copper DPC wire having class "F" insulation as per existing size and turns including connected minor insulation materials suitable for HT coil of 11 kV/ 415 V transformer complete all as specified and as directed.
M & L for reinsulating secondary side of copper and aluminium wound coil as per the existing size and baking the coil in vacuum furnace for 11 kV/ 415 V transformer complete all as specified and as directed.
M & L for rewinding of coils on primary side of transformer of any capacity using proper size, double paper covered aluminium winding wires conforming to IS 6162 (Part-II): 1971 as per existing size, turns and insulation class including connecting minor insulation materials suitable for 11 kV/ 415 V transformer complete all as specified and as directed.
M & L for rewinding of coils on secondary side of transformer of any capacity using proper size, double paper covered aluminium winding wires conforming to IS 6162 (Part-II): 1971 as per existing size, turns and insulation class including connecting minor insulation materials suitable for 11 kV/ 415 V transformer complete all as specified and as directed.
Supply, filling and topping up new transformer oil of dielectric strength not be less than 60 kV and conforming to IS 335: 1993 complete all as specified and as directed.
Supply only HV bushing of 12 kV grade with gasket/ packing materials for transformer upto 250 kVA etc. complete all as specified and as directed.
Supply only LV bushing of 1.1 kV grade with gasket/ packing materials for transformer upto 250 kVA with necessary gasket etc. complete all as specified and as directed.
Supply only oil level indicator clean prismatic type suitable for transformer upto 250 kVA with necessary gasket etc. complete all as specified and as directed.
Supply only complete set of metal parts for HV bushing of 12 kV grade with gasket for transformer upto 250 kVA with necessary gasket etc. complete all as specified and as directed.
Supply only complete set of metal parts for LV bushing of 1.1 kV grade with gasket for transformer upto 250 kVA with necessary gasket etc. complete all as specified and as directed.
S & F XLPE cable end termination, cold shrinkable, outdoor type, suitable for voltage 6.35 kV/ 11 kV (Earthed), 3 core, 120 sqmm to 185 sqmm complete all as specified and as directed.
S & F XLPE cable end termination, cold shrinkable, outdoor type, suitable for voltage 6.35 kV/ 11 kV (Earthed), 3 core, 50 sqmm to 95 sqmm complete all as specified and as directed.
S & F XLPE cable end termination, cold shrinkable, indoor type, suitable for voltage 6.35 kV/ 11 kV (Earthed), 3 core, 120 sqmm to 185 sqmm complete all as specified and as directed.
S & F XLPE cable end termination, cold shrinkable, indoor type, suitable for voltage 6.35 kV/ 11 kV (Earthed), 3 core, 50 sqmm to 95 sqmm complete all as specified and as directed.
Supply and erection in repairs of three piece metal oxide lightning arrestor suitable for 33 kV continuous operating voltage (3 phase) with rated voltage 36 kV (rms) with nominal discharge current rating of 2.5 kA and complete with galvanised clamping arrangements, GI bolts, nuts, washers etc. complete as specified and as directed.
Supply and erection in repairs of three piece metal oxide lightning arrestor suitable for 11 kV continuous operating voltage (3 phase) with rated voltage 12 kV (rms) with nominal discharge current rating of 2.5 kA and complete with galvanised clamping arrangements, GI bolts, nuts, washers etc. complete as specified and as directed.
S & F in repairs silica gel breather including silica gel, indicating type, 4 to 6 mm standard size of the particle, blue colour for transformer of capacity upto and including 500 kVA complete all as specified and as directed.
Disconnecting and Dismantling the existing indoor type, 11 kV horizontal draw out type OCB trolley of rupturing capacity 250 MVA, 400 Amps (Make Crompton Greaves, Type ALAI/XL) from location and repair /overhauling and carrying with following and all as specified and directed by engineer in Charge. (i) Inspecting/overhauling of spring drive mechanism by checking mechanism hold on catch assembly, trip bridge Z screw, Cam U, Aluminium trip bridge, Main trip lever assembly and apply multi grease lubricant to function smoothly. (ii)Inspecting / overhauling of OLTLF assemble, earth fault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system, (iii)Inspecting / overhauling /leaning and inspecting through insulators, moving contacts, fixed contacts, arcing chamber by carbon cleaner solution and apply dry graphite conductive sealant for contacts to avoid carbon deposits on contact surfaces. (iv) Filtration of Transformer oil to improve BDV value upto 50 kV DC (v) Inspecting/Cleaning of oil tank inside and outside surface by CRC thoroughly and replacement of transformer oil (60 liter for each OCB) and apply heavy duty grease for tank raising/lowering guide. (vi) Assembling all items/components parts to the respective position & testing the breaker with High Voltage and Meggering before and after high voltage test complete.
S & F main tripping coil with accessories as per the existing OCB of capacity 11 kV, rupturing capacity 250 MVA, 400 Amps complete all as specified and as directed.
S & F main bushing coil with accessories as per the existing OCB of capacity 11 kV, rupturing capacity 250 MVA, 400 Amps complete all as specified and as directed.
S & F HT bush suitable for capacity 400 A/ 800 A with accessories for OCB/VCB as per the existing complete all as specified and as directed.
M & L for spray painting of transformers (any type power or distribution)) of capacity upto and including 1000 kVA ( in situ ) outdoor type, installed and located at different sites in scattered area under the AGE(I) including the following: - (a) preparation of old surfaces by cleaning, scrapping, rubbing/ polishing etc. complete. (b) Spray painting with two coats of synthetic enamel paint of approved make / quality all as directed at site. (c) Writing the SM MES No of transformer on MS body of transformer all as directed .
M & L for preparing and painting on steel tubular swaged pole 410 SP-55 (11.00 metre long) including cross arms, GI brackets with two coats of aluminium paint over a coat of aluminium red oxide primer on exposed portion and including making strips of width 30 cm upto 1.5 m from the ground level in black and white shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M/S SHIVA TRADERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .