Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-AOC 59 4 23 TANTI PARA LANE HOWRAH PIN 711104 | HOWRAH | HOWRAH | WEST BENGAL | 711104 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹4.1 L+₹37,605 (10.0%)Rejected-Finance MOSAT HARIPUR RD P O HARIPUR HOOGHLY | HARIPUR | HOOGHLY | WEST BENGAL | 712701 | L2 | Rejected-Finance 2nd lowest bidder | |
| 3 | L3₹5.0 L+₹1.2 L (33.0%)Rejected-Finance 90 E B C ROAD KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | L3 | Rejected-Finance 3rd lowest bidder | |
| 4 | Rejected-Technical 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 | MURSHIDABAD | WEST BENGAL | 742237 | - | Rejected-Technical Disqualified in technical evaluation |
Tender Value
Refer Docs
EMD Value
₹8,000
Closing Date
22 Nov 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Exe.Engr._I, Kol. South Health El. Divn., PWDte
75 D H Road Kidderpore Kol_23
Electrical installation work for proposed ward at 5th floor of Trauma Care Centre in the premises of IPGMER-SSKM Hospital, Kolkata-E.I Work.
2023_WBPWD_596161_1
WBPWD/EE-I/KSHED/Q55/23-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Kolkata
Please refer Tender documents.
3 documents required · 3 mandatory
₹8,000
4 Apr 2025
20 Oct 2023
24 Nov 2023
20 Oct 2023
22 Nov 2023
24 Oct 2023
Amount
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (6way, Make - Legrand/Schneider/Siemens) (Make and model to be approved by EIC)
Supplying and fixing 2+14way double-door SPN MCB Distribution Board with IP-42/43 protection, on wall surface by necessary wall fasteners & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [ Make - Legrand/Schneider/Siemens) (Make and model to be approved by EIC)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. [ Make - Legrand/Schneider/Siemens) (Make and model to be approved by EIC)
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. [ Make - Legrand/Schneider/Siemens) (Make and model to be approved by EIC)
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] (Avg Run. 9 Mtrs)
Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch, 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 12 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc (Make: Legrand Myrius/ Schneider Livia/ L&T Englaze)
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(Make:Legrand Myrius/ Schneider Livia/ L&T Englaze)
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(Make: Legrand Myrius/ Schneider Livia/ L&T Englaze)
S & Drawing following sizes PVC insulated Cu. Wire (Make:- Finolex / Havells / RR Kabel /Gloster) in 20/25/ 32mm size PVC rigid/flexible conduit 'FR' (Precision make) on wall, ceiling with saddles and other accessories as required and mending good damages to building works.
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC ( From Panel to PBDB )
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC in 20mm rigid PVC Conduit ( From PBDB to SPN DB )
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC in 20mm rigid PVC Conduit (For Computer Board)
3x22/0.3 (1.5 sqmm) as ECC in 20mm rigid PVC Conduit (For Separate Board)
Finishing the end of following sizes copper wire end / PVC cable/Al. with dowells solderless socket by crimping method as pre GS as follows :-
S&F of 240V LED luminaire complete with all accessories suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length as follows:-
Supply & Fixing of new single LED Tube light fitting complete with 1x 18/20 Watt tube lamp (LED ) [Make - Philips cat no. TMC 502 P 1x T-LED, Master LED tube model no.18W 865 T8 I/ or similer specificition of wipro/Osram]
S&F of 240V 36/34 watt recess mounted LED slim (2' x 2') light fittings complete with all accessories. incl hanging provision suitable for 2'x2' grid ceiling to be fixed in false ceiling by S&F GI wire from ceiling with anchor fasner or bullet, nut, bolt etc. and necy. connection by 2 x1.5mm² PVC insulated Cu. Wire per direction of EIC.. [Make:-Wipro /Philips/Osram] (Make and model to be approved by EIC)
S/F of 240V., 1420 RPM, 300mm (12") Dia A.C. Exhaust Fan (EPC - Heavy Duty) incl. Cutting hole on wall, S&F Louver Shutter with Nuts, Bolts, washers etc. & mending good the damages to original finish. (Make - E.P.C. Electrical Pvt. Ltd., Heavy Duty)
S& Fixing only 18" (450mm) 4 (four) Blades Industrial type Bracket Fan complete with all accessories with S&F sequential timer (Approved Make) to be grouted on wall inclu. Making necesy. Connection as per direction of the EIC for lift m/c room. (Make - E.P.C.Electrical Pvt. Ltd., Heavy Duty).
S&F of MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat ncluding making good damages to building roof with satisfactory inishing and painting – (As per Drawing no. 475 of PWD pecification Book – May 1991)
S & F of 240 V. 1200 mm (48") sweep A.C. ceiling fan (Five Star rated) without regulator incl. down rod, canopy & fan blades etc. and engraving & Painting the Departmental Number (up to 14 digit) on Fan Body with black japan paint and interconnection complete in all respect. [Make: Crompton HB+ or HS+/Orient Energy star / Usha Striker plus].
Defect Liabibility Period 1 (One) year
Make & model of each and every material to be approved by EIC
GHANASHYAM ELECTRIC STORES
SIMPSON AND FERRIS PVT LTD
technical_1261355.pdf
PDF • 0.08 MB
techsummary_1261355.pdf
PDF • 0.08 MB
finance_1261355.pdf
PDF • 0.08 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_1261355.pdf
PDF • 0.08 MB
AOC.pdf
PDF • 0.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .