GE North Bikaner
GE North Bikaner
REPAIR MAINTAINANCE OF EM INSTALLATION CLEANING OF OVER HEAD TANKS RAW WATER RESERVOIRS CLEAR WATER RESERVOIRS AND REPAIR MAINT OF SUMMER APPLIANCES AND DEEP FREEZER WATER COOLER AC AT MFFR UNDER GE NORTH BIKANER
2021_MES_445900_1
GE (N) BKN-Token/20 /2021-2022
Open Tender
Miscellaneous Works
Item Rate
330 days
GE North Bikaner
Class D category b i
8 documents required · 8 mandatory
₹500
GE North Bikaner
₹60,000
Yes
15 Sept 2021
26 May 2021
25 Jun 2021
26 May 2021
23 Jun 2021
9 Jun 2021
Amount
Note for srl item No 01 to 17:- (i) Contractor must start cleaning proceess as and when asked by Engr In charge,if contractor failed to start work as on required time or delay the cleaning process intensioly then penalty of 1000 per day will be imposed for delayed time. (ii) The contractor shall write in white letters on black base colour with date of cleaning and next due date of cleaning with capacity of underground tank/sump/OHSR etc). Cleaning of raw water reservoir of capacity 8500KL of 5 metre depth complete by drain out water below the suction pipe by temporary pump arrangement by contractor and taking out sludge/foreign particle from bottom of reservoir by manually or mechanically and depositing at a distance of 200mtr away from the reservoir and cleaning all the walls of reservoir by metal brush and repairing the cracks and damages in walls and floor as per requirement of site and making good with cement and sand mortar, painting of wall and bottom of reservoir with 02 coats of cement base paint & Black and white painting in water proof of measurement scale, cleaning/removing sand and mud around the reservoir up to 5 meter circumstance of reservoir including removing grass and bushes at phase-II West Camp, Devaser water point complete all as specified and directed by Engineer-in-Charge - (cleaning of Water collection chamber Near canal is also included in Lump sump quated rate by tenderer
Ditto- all as per srl No 01 here-in-before but capacity of reservior is 6700 KL at west camp water point kharbara road PH-I.
Ditto- all as per srl No 01 here-in-before but capacity of reservior is 3600 KL at south camp water point.
Ditto- all as per srl No 01 here-in-before but capacity of reservior is 3600 KL at DBS water point.
Ditto- all as per srl No 01 here-in-before but capacity of reservior is 200 KL at East Camp phase-I (RD-160)
Ditto- all as per srl No 01 here-in-before but capacity of reservior is 5000 KL at East Camp phase-II
Ditto- all as per srl No 01 here-in-before but capacity of reservior is 3400 KL at North Camp phase-I (Rajana minor pump house)
Ditto- all as per srl No 01 here-in-before but capacity of reservior is 750 KL at RD 535 water point.
Cleaning of over head reservoir 100 KL capacity complete by drain out water taking out sludge foreign particle from bottom of reservoir and depositing at a distance of 100mtr away from the reservoir cleaning of wall of same by metal brush. Repairing the cracks and damages in wall and floor as per requirement of site and making good with cement and sand mortar. Painting of wall, outside area of OHSR and bottom of reservoir with 02 coats of cement based paint at phase-II South camp water point complete all as specified and directed by Engineer-in-Charge.
All as per item No 9 here-in-before but OHSR capacity 190 KL at Rajana Water point.
All as per item No 9 here-in-before but OHSR capacity 100 KL at DBS Camp
All as per item No 9 here-in-before but OHSR capacity 100 KL at East Camp
Cleaning of PVC Overhead tank 10x10000 liters capacity (i.e. 100 KL)complete by drain out water taking out sludge foreign particle from bottom of all tank and depositing at a distance of 100mtr away from the water point and cleaning of staging roof including all necessary materials and tools at West Camp Ph II Devasar complete all as required at site and directed by Engineer-in-Charge
Cleaning of underground sump of clear water reservoir 100 KL capacity complete by drain out water taking out sludge foreign particle from bottom of reservoir and depositing at a distance of 200mtr away from the sump, cleaning of wall of same by metal brush. Repairing the cracks and damages in wall and floor as per requirement of site and making good with cement and sand mortar. Painting of wall, MS Sheet cover plate, outside area of CWR and bottom of reservoir with 02 coats of cement based paint after inside and outside cleaning/removing sand and mud inside the sum & removing the same up to 5 mtr around the sump including removing grass and bushes at phase-II South camp water point complete all as specified and directed by Engineer-in-Charge.
All as per item No 14 here-in-before but CWR capacity 100 KL at DBS
All as per item No14 here-in-before but CWR capacity 100 KL at East camp
All as per item No 14 here-in-before but CWR capacity 95 KL at Rajana Water point
Excavation in trenches in soft/loose soil not exc 1.5mtr wide and not exc 1.5mtr in depth for taking out old pipe and laying new pipe line etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out complete all as specified and as directed.
Returning and filling including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and as directed.
Note for srl item No 21 to 78:- (i) Contractor must attand the complaint withib 24 Hours or resolve within in 72 hoursb if contractor failed to attand then penalty of 1000 per day will be imposed for delayed time. Supply and fixing in replacement of existing pipe any type and size in any condition at various location including GI pipe medium grade 50 mm bore (ISI marked) laid in trenches/ road crossings/along walls/ path /drain/floors with and including clamps, nuts, bolts, washers,sockets,elbow etc and all necessary arrangement to connect existing branch pipe of any type and size including all necessary fittings required at site and testing complete all as specified and as directed by the Engineer-in-Charge. (Note:- Earth work shall be measured and paid for separately.)
All as per item No 21 above but size 25mm dia.
M & L Taking out u/s rusted corroded GI pipe of size 50 mm dia after cutting/unscrewing including all fittings from trenches /along walls/under roar etc complete all as specified and directed.
M & L Taking out u/s rusted corroded GI pipe of size 25 mm dia after cutting/unscrewing including all fittings from trenches /along walls/under roar etc complete all as specified and directed.
M & L for repairing the leakage of CI/DI pipe line 150 mm dia incl necessary excavationand bailing out of stagnent water and removing wild bushes/grass 3 mtr away from both sides of pipe line and removing u/s lead from the joint by burning and making new run joint all as directed by Eng-in-Charge.
M & L for repairing the leakage of CI/DI pipe line 100 mm dia incl necessary excavationand bailing out of stagnent water and removing wild bushes/grass 3 mtr away from both sides of pipe line and removing u/s lead from the joint by burning and making new run joint all as directed by Eng-in-Charge.
M & L for repairing the leakage of CI/DI pipe line 80 mm dia incl necessary excavationand bailing out of stagnent water and removing wild bushes/grass 3 mtr away from both sides of pipe line and removing u/s lead from the joint by burning and making new run joint all as directed by Eng-in-Charge.
M & L for repairing the leakage of GI/ pvc pipe line 50 mm dia incl necessary excavationand bailing out of stagnent water and removing wild bushes/grass 3 mtr away from both sides of pipe line and removing u/s fittings from the joint/ leakage point and making new joint/repair with neccessary GI/PVC fiitins and testing or all as directed by Eng-in-Charge.
Supply and fixing in replacement of cast iron sluice valve 80 mm, heavy duty class PN 1:6 ISI marked (IS-14846-2000), long body, both ends flanged, complete with high tensile stainless steel spindle, cast iron hand operated wheel and cap top, nuts, bolts, washers including 3mm thick rubber gasket joints, suitable for 80 mm bore GI/PVC pipe any type any size and also including testing and commissioning complete all as specified and as directed. Make - Leader/Sant/Kirlosker
Ditto all as per serial item No. 29 here in before but suitable for 100mm bore.Make - Leader/Sant/Kirlosker
Ditto all as per serial item No. 29 here in before but suitable for 150mm bore.Make - Leader/Sant/Kirlosker
Ditto all as per serial item No. 29 here in before but suitable for 200mm bore.Make - Leader/Sant/Kirlosker
Supply and fixing in replacement of existing flexible hose pipe(as per sample approved by Engr in charge) of 100 mm dia suiatable for lorry filling point all as specified & directed by the Engineer-in-Charge.
Supply and Fixing in replacement of Reflex Valve/NRV/Dual plate check valve, PN 1.6 rating of size 80 mm dia with all necessary accessories and testing complete all as specified & directed. Make - Leader/Sant/Kirlosker
All as per item No 34 above but size 100mm suitable for 100mm dia GI/DI pipe line
All as per item No 34 above but size 150mm suitable for 150mm dia GI/DI pipe line
Supply and Fixing in repair foot valve of any type & in any condition CI Foot Valve size 80 mm dia conforming to IS suitable for 80mm bore pipe any type i.e thread/flanged type complete all as required at site. Make - Leader/Sant/Kirlosker
All as per item No 37 above but size 100mm suitable for 100mm dia GI/DI pipe line
Supply and Fixing in repair butterfly t valve of any type & in any condition butterfly Valve size 80 mm dia conforming to IS suitable for 80mm bore pipe any type i.e thread/flanged type complete all as required at site. Make - Leader/Sant/Kirlosker
S&F in replacement of four pole offload changeover switch 200 Amps, 415 Volts with sheet steel enclosure including disconnecting existing cable connection and reconnecting after fixing the same as directed by Engineer-in-Charge complete all as specified and as directed by Engineer-in-Charge.Make :- Havells HSN code 8563 or equilant in L&T/Siemens//C&S
All as per item No 40 above but suitable for size 100 Amps 415 volts.
All as per item No 40 above but suitable for size 63 Amps 415 volts.
Dismantling the electric induction motor AC 3 Phase, 7.5 HP, 440 V, 1470RPM, 50Cycle of any make and type from the foundation and pump after disconnecting electric cable connection and earthing etc. and transportation to civil workshop for repair/rewinding, strip opening the motor and removing of defective burnt winding, rewinding the motor after cleaning the roter and stator with super enameled copper winding wire of suitable turn and gauge as per the original with proper insulation including varnishing, providing all high grade material and class ‘B’ varnish for insulation, reassembling the complete motor and re-fixing at site with electric cable connection, earthing and testing the motor on full load at site after coupling the pump for its serviceability up to entire satisfaction of Engineer-in-charge.
Removing the existing unserviceable electrical cable connection from star delta starter to motor and replace the same with PVC insulated unsheathed copper conductor multi stranded cable single core 6 x 16 sqm , 1100 volts grade confirming to IS 694 drawn through and including rigid/flexible PVC conduit of suitable size including connecting up etc all specified and directed .Note:- 6 runs of cable and one run of PVC conduit will be measured as one unit length
Supply and fixing in replacement MCCB four pole Fixed thermal fixed magnetic , 250 Amp, 415 Volts,4Pole , 50 cycle, breaking capacity 50KA complete all as specified and as directed by Engineer-in-charge.Make : L & T/ Havells / Siemens/BCH/ Legrand/Indo Asian
All as per item No 45 above but suitable for size 200 Amps 415 volts.
All as per item No 45 above but suitable for size 100 Amps 415 volts.
Dismantling the electric driven air compressor twin blower rotary type cap 7.5 HP 350 cum/hr pressure 1440 RPM 440 V, 50 Cycle of any make and type from the foundation and disconnecting electric cable connection and earthing etc. and transportation to civil workshop for repairing and replacing the worn out bearings ,suction filter ,pressure relief valve ,pressure gauge and V belts with initial filling new compressure oil of superior grade all as per original quantity and draining out the existing ol and reassembling the complete and re-fixing at site with electric cable connection, earthing and testing theair compressor on full load at site up to entire satisfaction of Engineer-in-charge.
Supply, laying, jointing, testing and commissioning LT XLPE insulated, PVC sheathed armoured heavy duty electric cables LT 1100 volt grades with copper stranded conductor passing through pipes, in duct, on poles,in trenches, under road etc complete all as specified and directed of following :- (a) 10 Sqmm 4 core
(b) 25 Sqmm 4 core
(c) 50 Sqmm 3.5 core
Rapid Gravity Filter (a) Fine Sand with silt content not more than 5% free from all impurities (0.45 to 0.65mm) Thick (As per sample). It should be cleaned and pass through sieve no. 10 (1.67mm) and should be retain on sieve no.66 (size0.25mm) the Silt should not exceeds 2%
Gravels It should be cleaned hard & uniform quality one free from dirt, clay and organic matters .It should be laid in layer of effective size 5 mm to 40mm complete all as specified & directed
Pressure filter M & L Fine Sand with silt content not more than 5% free from all impurities (0.45 to 0.65mm) Thick (As per sample). It should be cleaned and pass through sieve no. 10 (1.67mm) and should be retain on sieve no.66 (size0.25mm) the Silt should not exceeds 2%
M&l Gravels .It should be cleaned hard & uniform quality one free from dirt, clay and organic matters .It should be laid in layer of effective size 5 mm to 40mm complete all as specified & directed
Taking out the existing filter media of any size from filter bed of tank any depth including removing material to a distance exceeding 50 meter not exc 100 meter complete all as specified and directed.
Cleaning and scratching the surface of filter bed walls, floor truffs, drains etc by wire brushes or otherwise to remove the deposited mud silt etc, washing and cleaning all the affected surface with water complete all as specified and directed
Cleaning, washing of existing of natural pebbles (i.e. fine/coarse sand, gravel etc) obtained from serial item No 56.00 here in before for making it free from silt and other deterious material, screening aggreegate of different size and depositing packing in layer as per direction in filter bed etc complete all as specified and directed
S&F in replacement of foundation frame made out of MS angles/channels etc including drilling holes & welding suitable for 3 to 20 HP monoblock/centrifugal pump set with nut bolts etc as per sample including all necessary arrangements with grouting of foundation bolt in PCC making good damaged foundation complete all as required at site.
Supply and fixing in replacement of star coupling of rubber for motor pump set of capacity 03 to 40 HP complete all as specified & as directed by Engr-in-charge.
Supply and fixing in replacement of MS Housing for star coupling for motor pump set of capacity 03 to 40 HP complete all as specified & as directed by Engr-in-charge.
Material and labour for existing LT Panel wiring Circuit complete with new internal wiring set connection in panel including all necessary arrangement & testing etc including removing of old unserviceable wiring set, circuit set etc any type any size and in any condition replacement of worn out spare parts as mentioned under resective item No-64 to 69 here in after.complete all as required at site and directed
Supply and Fixing in replacement of Electronic contactor suitable for 5 to 10 HP Pump set starter, 415 volt, 50 Hz, 3 phase, Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic relay suitable for 5 to 10HP Pump set starter, 415 volt, 50 Hz, 3 phase, Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic contactor suitable for 20HP Pump set starter, 415 volt, 50 Hz, 3 phase, Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic relay suitable for 20HP Pump set starter, 415 volt, 50 Hz, 3 phase, Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic contactor suitable for 3HP Pump set starter, 415 volt, 50 Hz, 3 phase, Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic relay suitable for 3HP Pump set starter, 415 volt, 50 Hz, 3 phase, Make-L&T/Scneider/siemens
Earthing complete with galvanised steel earth plate electrode of size 60cmx 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including earth lea of size 32x6mm GI strip by means of GI bolts/nuts/check nuts/washer/thimbles etc protected by 40mm bore light grade pipe and connecting to main switch board or panel and testing on completion. Earth plate shall be surrounded by packed layer of coat dust 300mm and common salt 15cm thick all around 40mm bore GI light grade pipe for eatering and including funnel, wire mesh 75mm thick cover of RCC 1:2:4 type B-1 with kand including CI frame, PCC (1:3:6) type C-2 (Using 40mm graded stone aggreagate) as in earthing pit including necessary excavtion and rarth work, all as speciied and shown in electrical plate No-3 of SSR Part-I (Notes for srl item No.70 here-in-before :- (i) GI pipe including fittings for watering shall be provided upto plug at top and cost of the same shall be deemed to be included in the unit rate quoted for earthing. (ii) G I pipe 20mm dia light grade from earth electrode upto main switch panel for protection of earth lead wire shall be deemed to be included in the unit rate quoted for earthing).
S&F in replacement of pressure guage of 0 to 10.0 Kg/sqcm with all accessories including all necessary arrangement i.e. cutting,drilling,threading etc in existing pipe required at site & testing complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fixing in replacement of Air Release Valve (ARV) size 50 mm Dia with two air outlet for fixing up in DI/GI/HDPE water supply pipe line including all necessary arrangement i.e. cutting,drilling,threading of 2.5 mtr long GI pipe 50 mm bore ISI mark medium grade as required at site & testing complete all as specified & directed.
Supply and Fixing of Bulk Water Meter size 150 mm dia in existing GI/PVC/DI pipe including all necessary arrangement i.e. cutting,drilling,threading etc in pipe required at site & testing including taking out old unserviceable meter any type any size and in any condition complete all as specified & directed by the Engineer-in-Charge.
All as per item No 75 above but size 100mm dia.
Material and labour for CI/DI pipe cutting 200 mm dia for water supply header of required length by reducing to required length and for insertion of new branches, tees, collar, tail pieces etc in position and reconnectiting , jointing and testing existing pipeline complete all as specified.
Material and labour for CI/DI pipe cutting 150 mm dia for water supply header of required length by reducing to required length and for insertion of new branches, tees, collar, tail pieces etc in position and reconnectiting , jointing and testing existing pipeline complete all as specified.
Supplying and laying testing of CI pipe of bore 200 mm (ISI marked) with spigot & socketed ends centrifugally cast, class K-9 suitable for rubber tyton joints laid in trenches complete & re-connection to existiong water pipelines with all neccessary fittings all as specified and directed by Engr-in-Charge. (Note : - Rubber tyton joints and fittings will be measored separately in respective items.
All as per item No 79 here-in-before but suitable for 200 mm dia
Supplying & fixing CI special fitting of any size, type, radius, angle, tapers, increasing, decreasing sockets, tees, tail pieces and collars etc complete up to 150 mm dia.
Desert Cooler Repair to Desert Cooler Removing of old paint complete with emery paper and cleaning with scrapper and preparation of internal surfaces & bottom of the desert coolers and apply one coats of black bituminous paint complete all as specified
All as per item No. 79 here in before but applying one coats of synthetic enamel paint to external surfaces of desert coolers including steel grills, removing of wooden grass pad & refixing the same after necessary work side panel etc complete all asp specified.
Taking down carefully old unserviceable water pumps heavy duty of capacity 1/70 HP, 230 volts 50 HZ single in lieu providing new submersible type water pump including necessary wire connection etc. M Make;- Bajaj/CG/ Havells
Taking down carefully fan motor from existing desert coolers and in lieu providing new fan motor 1/5 to 1/6 HP 230 volts, 50 HZ, including replacement of mounting legs & nuts bolts capacitor 4 Mfd as reqd at site complete all as specified and directed. Make;- Bajaj/CG/ Havells
Taking down carefully fan motor 1/5 to 1/6 HP 230 volts, 50 HZ, from existing desert coolers of each camp at MFFR and refixing the same camp fan motor after rewinding with super enameled copper wire of existing size complete including replacement of bush/bearing, mounting legs & nuts bolts capacitor 4 Mfd as reqd at site complete all as specified and directed. Make: Milan/chetak Note:- Contractor will be arranged all required T&P (winding machine) repair for desert cooler motor/sevicing i.e winding/greasing /oiling in AGE MFFR yard)
Taking down the following parts from the existing desert coolers & providing new parts in same possition as listed below- (a) Capacitor for desert cooler 4 MFD 230 volts Make: Asian/Tibcon
GI sheet as per existing guage front grill including nuts bolts and washers suitable for 18/20" sweep desert coolers including necessary wire connection, regulator & on/off switch etc reqd at site, Make-Alka/kinark.
Taking down following part of desert cooler old rusted as under and M & L out of 20 gauge GI plain sheet class-III including cost of riveting welding, nuts and bolts as required accessories for fixing etc complete (a) Bottom tank as existing size
Top cover as existing size
Side panels size- set of three
Wood wool pad for desert coolers (set of three)
Supporting jali for desert coolers (set of three)
Plug Top 3 pin, 5-A, 230 Volt
Plug Top 3 pin, 15-A, 230 Volt
Fan blades made of aluminium for desert cooler as per sample
Cable, 3 core, copper conductor size 23/0.0076 for desert cooler. Make: plaza/finolex/kalinga
Supply only condenser 2.5 MFD
Replacement of PVC pipe 15mm for desert cooler including all necessary 'T' joints & clamps reqd at site
Distributor of PVC for desert cooler with fixing bolt
Replacement of Elbow of PVC for desert cooler
S&F in repair tap mounting with nipple 1/2" as per sample.
S&F in repair water outlet nipple with washers and check nuts (copper/brass)
DEEP FREEZER Taking down unserviceable compressor from deep freezer including bushes, gromments, sleeves, washers, mounting rubbers, nuts, bolts terminal cover brazing and clips from existing deep freezers of capacity 320 ltr, Make: voltas/Usha/Sidhwal/Blue star complete all as directed.
Supply and fixing compressor suitable for deep freezer 320 ltr make- Blue star/Gulmarg/Usha, Compressor of make: Emerson Model No. CAJ 34/KCE 444 HAG with necessary accessories including provn of new bushes, gromments, sleeves, washer, mounting rubbers, nuts and bolts, terminal covers, brazing and clips.
Supply and fixing compressor suitable for deep freezer 405 ltr make- Blue star, Compressor of make: Emerson Model No. CAJ 34/KCE 444 HAG with necessary accessories including provn of new bushes, gromments, sleeves, washer, mounting rubbers, nuts and bolts, terminal covers, brazing and clips.
Cleaning of complete deep freezer existing gas system with CTC, testing of leakage, charging of refrigerant with R-134 (a) after rectification of leakage in existing deep freezer of 320 /405 ltrs capacity of make and model as per existing complete all as specified and as directed.
Water Cooler Taking down unserviceable compressor form deep freezer including bushes, gromments, sleeves, washers, mounting rubbers, nuts, bolts terminal cover brazing and clips from existing water coolers of Make: voltas/Usha/Sidhwal/Blue star 60/120,150/180.
Supply and fixing new hermetically sealed unit (compressor) of following Makes and model including provision of new bushes,grommets, sleeves , washers, mounting rubers nuts boltes,terminals,covers,brasing and clips in the existing Water coolers 60/120 Ltrs Make :- Blue star /usha /voltas with necessary accessaries and all as directed.
all as per item No. 106 here in before but for 150/180ltrs capacity complete all as specied and as directed by engr -in-charge.
Taking down carefully existing internal wiring of existing water coolers and in liu provision of new internal wiring of with PVC insulated copper conducter cable of size 40/ 0.0076 sq mm including replacementof main lead 03 meter long, terminals clips, thimbles, 03 pin plug top 15 amps & soldering extra compelte all as specified. Make :- of wiring plaza/finolex
Cleaning of complete existing gas system with CTC, testing of leakage, charging of refrigerant with R-134 (a) after rectification of leakage in existing water cooler complete all as specified and directed.
Removing of old rusted warn out portion of sheet/angle/flat iron from base, front and top etc. of the water cooler/ air conditioner and providing new mild steel sheet, angle iron/MS flat including necessary bending, welding. reveting etc. including making provision for mounting of fan motors, compressor, and condenser complete all as specified.
Complete removing old faded paint from steel surfaces of water cooler by scrapers making the surface smooth including filing material and painting the surface of any description over 10 Cm in width of girth not otherwise described with one coat of red oxide primer and two coats of synthetic enamel paint complete all as specified and directed.
Taking down deffective fan motor from water coolers, dismentling the old burnt winding from the motor and rewinding with super enameled copper wire as per existing size. Make : Milan/Chetak including replacement of shaft, boshes, mounting rubbers, nuts, bolts and refixing after reassembling and testing in existing water cooler for under mentioned fan motors :- (Note : The unit rate coated shall be deemed to be included replacement of minor spares such as rubbers, nuts, washers, insulating materials and clams) Fan motors of capacity 1/16 HP 230 Volts single phase.
Fan motors of capacity 1/32 HP 230 Volts single phase.
Fan motors of capacity 1/35 HP 230 Volts single phase.
fan blade made out of aluminium as per sample
Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/35 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and directed.
Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/16 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and directed.
Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/10 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and directed.
Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/25 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and directed.
S & F push cock (stainlees steel) for water cooler as per sample existing.
S & F thermostat for water cooler as per sample existing.
S & F relay with OLP suitable for water cooler existing as per sample.
S & F runing capacitor 36 MFD. Make : Tibcon/Sharda/Epcos
S & F runing capacitor 60/80 MFD. Make : Tibcon/Sharda/Epcos
S & F runing capacitor 80/100 MFD. Make : Tibcon/Sharda/ Epcos
S & F runing capacitor 100/120 MFD. Make : Tibcon/Sharda/ Epcos
S & F runing capacitor 10MFD. Make : Tibcon/Sharda/Epcos
S & F runing capacitor 15MFD. Make : Tibcon/Sharda/Epcos
S & F runing capacitor 40/60 MFD. Make : Tibcon/Sharda/Epcos
Cable, 3 core, copper conductor size 40/0.0076 for water cooler. Make: plaza /finolex/kalinga
Air Conditioner Taking down unserviceable compresor 2TR capacity from the window/split AC of any make and supply and fixing new compresor 2 Ton capacity of including bushes, grommets, sleeves, washers, mounting rubbers, nuts, bolts, terminal covers, brazing and clips from existing AC complete all as specified and as directed.
All as per srl Item No. 131 here-in before but for window type AC 1.5 TR capacity of any make as per existing.
Cleaning of complete existing gas system with CTC, testing of leakage, charging of refrigerant with R-134 (a) after rectification of leakage in existing window/split type air conditioner of 1.5/2 TR capacities of make and model as per existing complete all as specified and directed.
Taking down unserviceable fan motor of any capacity from the window type air conditioner 1.5/2 TR capacity and dismantling old and unserviceable burnt winding wire and rewinding with super enameled copper wire of existing guage and size including heat varnishes replacement of shaft, bearing and bush complete all as found unserviceable after opening complete all as specified and required and as directed.
Removing of existing window/split type AC 1.5/2 Ton capacity mounting, cleaning of evaporator and condenser with alkaline based solution, washing of AC, oiling of fan motor and refixing on mounting including provn for making opening air tight and dust proof including testing and commissioning complete all as directed.
S & F running capacitor 45 MFD Make : Tibcon/Sharda/Epcos
S & F running capacitor 60 MFD Make : Tibcon/Sharda/Epcos
S & F running capacitor 50 MFD Make : Tibcon/Sharda/Epcos
S & F PCB (Printed Circuit Board) of window/split type capacity 1.5/2 Ton all as specified and as directed.
Replacement of remote control of 1.5/2 Ton window/split type AC of any make/type all as specified and as directed.
Taking down carefully the following parts from the existing AC and in lieu providing new accessories/parts as per existing and complete overhoauling of AC 1.5/2 ton capacity all as specified: -Note- Accessories/parts paid saperately under relevent items
PVC filters for AC (window/split)
Contactor for split AC
Starting relay for AC
Replacement of burnt out transformer and S&F new transformer of 3 or 4 KVA voltage stabilizer of any make.:'V' guard
Taking down unserviceable indoor unit of split AC capacity 1.5 TR from existing place and supply and fix new indoor unit of split AC 1.5 TR capacity of including mounting frame with nuts, bolts in existing place complete all as specified and as directed. Make :- Sumsung
Taking downunserviceable Exhaust rooler of split AC capacity 2.0 TR from existing place and supply and fix new Exhaust rooler of split AC 1.5 TR capacity of including bush/bearing as per existing type complete accessories fix in existing place complete all as specified and as directed. Make :- Sumsung
Taking downunserviceable out door unit of split AC capacity 1.5 TR from existing place and supply and fix new indoor unit of split AC 1.5 TR capacity of including mounting frame with nuts, bolts and complete accessories fix in existing place complete all as specified and as directed. Make :- Sumsung
Supply and laying PVC insulated stranded aluminium conductor cable heavy duty 1100 Volts grade served with an inner sheathing of PVC tape & overall PVC sheathed 06 Sqmm 2 core nominal cross section incl remove unserviceable cable complete all as specified. Make - (Asian Cable Co./Finolex/Polycab)
Ceiling Fan Taking down ceiling fan for repair/servicing i.e. winding/greasing/oiling etc., 1200/1400 mm sweep, of any make and any type model, ceiing cable end with tape, dismandling the blades, removing fan and deposit the blades/motor to store for repairing/servicing complete all as specified and as directed by Engineer-in-charge. (Note:- Contractor will be taking down ceiling fan of each camp in MFFR and carrying with saftey deposit for repair/sevicing i.e winding/greasing /oiling in AGE MFFR yard and camp wise marked each fan by permnent marker and informed to JE E/M )
M&L re-winding of ceiling fan of size 1200 mm sweep with super enameled copper winding wire of gauge as per existing size/No of wire conforming to IS, including varnishing the motor windings with best quality varnish, capacitor 2.5 Mfd and fixing the same place complete all as specified and as directed by Engineer-in-charge. (Note:- Contractor will be arranged all required T&P repair for ceiling fan/sevicing i.e winding/greasing /oiling in AGE MFFR yard)
S&F in replacement of ball bearing of size/No. 6201 conforming to IS complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of ball bearing of size/No. 6202 conforming to IS complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of ball bearing of size/No. 6203 conforming to IS complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of brass bush suitable for ceiling fan of any make and model conforming to IS complete all as specified and as directed by Engineer-in-charge
Taking down and dismantling of exhaust fan 250 mm/350 mm/450 mm sweep of any make and model, opening the cover, separating the rotor and startor assembly, locating the fault and maing the fan in fully serviceable condition including replacing the defected worn out screw, flexible wire size 23/0.0076, oiling/greasing the fan and re-assembling the samd and testing complete to the entire satisfaction of Engineer-in-charge.
Re-winding of exhaust fan 250 mm sweep with super enameled copper winding wire as per existing size conforming to IS including varnishing the motor windings with best quality varnish, capacitor and fixing the same place complete all as specified and as directed by Engineer-in-charge. Note:- Contractor will be arranged all required T&P repair for exhaust fan/sevicing i.e winding/greasing /oiling in AGE MFFR yard)
Ditto all as per item No. 157 here in above but of size 350 mm sweep complete all as specified and as directed by Engineer-in-charge.
Ditto all as per item No. 157 here in above but of size 450 mm sweep complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of blades suitable size for exhaust fan 250 mm duly approved by Engineer in charge complete all as specified and as directed by Engineer-in-charge.
Ditto all as per item No. 160 here in above but size of exhaust fan 350 mm sweep complete all as specified and as directed by Engineer-in-charge.
Ditto all as per item No. 160 here in above but size of exhaust fan 450 mm sweep complete all as specified and as directed by Engineer-in-charge.
S&F D clamp with nuts, check nuts, quarter pin and rubber reel suitable for 1200/1400 mm sweep of ceiling fan all as required at site and as directed by Engineer in charge.
S&F PVC canopies (set of two) as required at site and as directed by Engineer in charge.
S&F condenser 2.5 MFD conforming to IS complete all as specified and as directed by Engineer-in-charge.
S&F in replacement stepped type electronic fan regulator flush type on existing laminated sheet as per requirement including taking down old regulator complete all as specified and as directed by Engineer-in-charge.
Taking down unsv louver and supply and fix new louver of exhaust fan of size 300 mm complete all as specified and directed by Engr-in- charge.
Taking down unsv louver and supply and fix new louver of exhaust fan of size 450 mm complete all as specified and directed by Engr-in- charge.
Supply and fixing PVC fresh air fan (Exhaust fan) of size 250/300 mm sweep and connecting up including three core PVC insulated multi stranded copper conductor cable of size 1.5 Sqmm wire from ceiling rose/connector to fan of length not less than 1.0 meter complete all as specified and directed. Make: - Usha/Bajaj/Havells
Gill Construction Co
singh enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .