Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹7.2 LAdmitted-Finance | Admitted-Finance | |
| 2 | ₹7.3 LAdmitted-Finance | Admitted-Finance | |
| 3 | ₹7.5 LAdmitted-Finance | Admitted-Finance | |
| 4 | ₹7.7 LAdmitted-Finance | Admitted-Finance | |
| 5 | ₹7.7 LAdmitted-Finance | Admitted-Finance |
| Sl No | Description | Qty | Unit | INSTANT TRADE CORPORATION | HYDROCON ENGINEERS | CHANDERA BUILDERS | DEEPAK ENTERPRISES | R K CORRUGATEDBOX AND ALLIED PRODUCTS | Goodwill Enterprises | M/S CHAITANYA CONSTRUCTION CO. | Raj Engineering Co. | Volts And Watts Electronics Pvt. ltd. | Shiva Buildtech | R.K. Enterprises(India) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of old pump set after disconnecting from suction and delivery pipeline, decoupling with motor, removing of electric connections from motor i/c taking out old pump from existing system etc., closing of suction & delivery line with the help of suitable size dead flange. | 2 | Jobs | 18,800 ₹22,184 | 10,000 ₹11,800 | 24,000 ₹28,320 | 2,000 ₹2,360 Lowest | 30,000 ₹35,400 | 13,000 ₹15,340 | 29,000 ₹34,220 | 15,000 ₹17,700 | 20,000 ₹23,600 | 16,000 ₹18,880 | 24,000 ₹28,320 |
| 2.00 | Providing of horizontal split casing centrifugal pump suitable to handle potable water Having flanged suction & delivery with CI impeller, CI body, S.S. Shaft & S.S. Sleeve suitable for head 45 mtr., Discharge 85 m3 /hr., 1450 RPM Suitable for prime mover (motor) of capacity 20 HP. Make of Pump:- KBL /Any DJB approved make.
Providing of 20 HP 1450 RPM Squirrel case induction motor suitable to operate on 430V,3 phase,50 Hz, horizontal foot mounted confirming to IEC:60034-1.
Make of Motor- ABB/Kirloskar electric Co./ DJB Approved | 2 | Jobs | 4,39,000 ₹5,18,020 | 4,16,000 ₹4,90,880 | 3,76,000 ₹4,43,680 | 4,00,000 ₹4,72,000 | 3,99,998 ₹4,71,997.64 | 2,82,400 ₹3,33,232 Lowest | 8,71,600 ₹10,28,488 | 4,78,000 ₹5,64,040 | 3,20,000 ₹3,77,600 | 3,00,000 ₹3,54,000 | 4,41,000 ₹5,20,380 |
| 3.00 | Dismantling and taking out M S Base frame from CC foundation after cutting of nut bolts, Breaking the Damaged RCC foundation of the old pump set by the help of concrete breaker and labour. Also taking out malba from the pump house by manual labour & dumping the same as per directions. | 2 | Jobs | 23,900 ₹28,202 | 10,000 ₹11,800 | 22,000 ₹25,960 | 2,000 ₹2,360 Lowest | 20,000 ₹23,600 | 24,400 ₹28,792 | 25,000 ₹29,500 | 11,000 ₹12,980 | 20,000 ₹23,600 | 22,000 ₹25,960 | 25,800 ₹30,444 |
| 4.00 | Making a RCC foundation of new Pump Set of material Ratio 1:1.5:3 (cement, coarse sand and graded stone aggregates) concrete with foundation/rag bolts as per site requirement. Providing & fixing of M.S base frame of suitable size with nut bolt & washer etc for pump sets as per site requirement. | 2 | Jobs | 48,000 ₹56,640 | 50,000 ₹59,000 | 52,000 ₹61,360 | 20,000 ₹23,600 | 50,000 ₹59,000 | 35,000 ₹41,300 | 71,600 ₹84,488 | 15,000 ₹17,700 Lowest | 60,000 ₹70,800 | 46,000 ₹54,280 | 50,000 ₹59,000 |
| 5.00 | Providing & fixing of Suitable size coupling for pump set with Suitable size coupling guard & fixing with nut bolt & washer etc as per site requirement. | 2 | Jobs | 19,000 ₹22,420 | 10,000 ₹11,800 Lowest | 12,000 ₹14,160 | 20,000 ₹23,600 | 10,000 ₹11,800 Lowest | 22,400 ₹26,432 | 25,000 ₹29,500 | 11,000 ₹12,980 | 20,000 ₹23,600 | 18,000 ₹21,240 | 20,000 ₹23,600 |
| 6.00 | Supply of CIDF Non rising spindle sluice valve PN 1.0 of size 100 mm dia DJB Item code 4.22.3. Make: Kirloskar/IVC/ DJB Approved. | 2 | Nos. | 41,100 ₹48,498 | 40,000 ₹47,200 | 36,000 ₹42,480 | 30,000 ₹35,400 | 16,000 ₹18,880 Lowest | 41,000 ₹48,380 | 25,000 ₹29,500 | 24,800 ₹29,264 | 28,000 ₹33,040 | 36,000 ₹42,480 | 44,000 ₹51,920 |
| 7.00 | Supply of CIDF Swing type Non-return valve PN 1.0 of size 80 mm dia. DJB Item code 4.14.3Make: Kirloskar/IVC/ DJB Approved. | 2 | Nos. | 17,400 ₹20,532 | 40,000 ₹47,200 | 18,000 ₹21,240 | 15,000 ₹17,700 Lowest | 16,000 ₹18,880 | 16,400 ₹19,352 | 90,000 ₹1,06,200 | 19,400 ₹22,892 | 28,000 ₹33,040 | 17,200 ₹20,296 | 18,000 ₹21,240 |
| 8.00 | Supply of CIDF Non rising spindle sluice valve PN 1.0 of size 80 mm dia. DJB Item code 4.22.2Make: Kirloskar/IVC/ DJB Approved. | 2 | 2 Nos. | 31,200 ₹36,816 | 40,000 ₹47,200 | 26,000 ₹30,680 | 24,000 ₹28,320 | 14,000 ₹16,520 Lowest | 33,000 ₹38,940 | 25,160 ₹29,688.8 | 19,400 ₹22,892 | 24,000 ₹28,320 | 30,000 ₹35,400 | 34,000 ₹40,120 |
| 9.00 | Supply of PVC Insulated single core un-armoured Flexible Copper Cable of size 25 Sq.mm. Make : Grandley / Gloster/Havells/DJB approved | 100 | Mtr | 38,800 ₹45,784 | 50,000 ₹59,000 | 32,000 ₹37,760 | 50,000 ₹59,000 | 41,100 ₹48,498 | 45,000 ₹53,100 | 45,000 ₹53,100 | 24,000 ₹28,320 Lowest | 36,000 ₹42,480 | 35,000 ₹41,300 | 39,000 ₹46,020 |
| 10.00 | Providing & fixing of Bourdon pressure Gauge of suitable size in delivery line of Pump set.. | 2 | Jobs | 2,200 ₹2,596 | 5,000 ₹5,900 | 3,000 ₹3,540 | 4,000 ₹4,720 | 700 ₹826 Lowest | 45,000 ₹53,100 | 2,500 ₹2,950 | 1,600 ₹1,888 | 20,000 ₹23,600 | 2,200 ₹2,596 | 2,400 ₹2,832 |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
25 Jul 2025, 2:00 pmClosed
EXECUTIVE ENGINEER (EM) M-10
GREATER KAILASH, PART-I, NEW DELHI
Replacement of Pump sets and other allied works at Vasant apartment BPS R.K PuramAC-44.
2025_DJB_275650_21
NIT No. 7/EE(EM)M-10/(25-26)
Open Tender
Electrical Work/ Equipment
Works
30 days
EXECUTIVE ENGINEER (EM) M-10
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹19,000
Yes
26 Sept 2025
18 Jul 2025
25 Jul 2025
18 Jul 2025
25 Jul 2025
18 Jul 2025
Dismantling of old pump set after disconnecting from suction and delivery pipeline, decoupling with motor, removing of electric connections from motor i/c taking out old pump from existing system etc., closing of suction & delivery line with the help of suitable size dead flange.
Providing of horizontal split casing centrifugal pump suitable to handle potable water Having flanged suction & delivery with CI impeller, CI body, S.S. Shaft & S.S. Sleeve suitable for head 45 mtr., Discharge 85 m3 /hr., 1450 RPM Suitable for prime mover (motor) of capacity 20 HP. Make of Pump:- KBL /Any DJB approved make. Providing of 20 HP 1450 RPM Squirrel case induction motor suitable to operate on 430V,3 phase,50 Hz, horizontal foot mounted confirming to IEC:60034-1. Make of Motor- ABB/Kirloskar electric Co./ DJB Approved
Dismantling and taking out M S Base frame from CC foundation after cutting of nut bolts, Breaking the Damaged RCC foundation of the old pump set by the help of concrete breaker and labour. Also taking out malba from the pump house by manual labour & dumping the same as per directions.
Making a RCC foundation of new Pump Set of material Ratio 1:1.5:3 (cement, coarse sand and graded stone aggregates) concrete with foundation/rag bolts as per site requirement. Providing & fixing of M.S base frame of suitable size with nut bolt & washer etc for pump sets as per site requirement.
Providing & fixing of Suitable size coupling for pump set with Suitable size coupling guard & fixing with nut bolt & washer etc as per site requirement.
Supply of CIDF Non rising spindle sluice valve PN 1.0 of size 100 mm dia DJB Item code 4.22.3. Make: Kirloskar/IVC/ DJB Approved.
Supply of CIDF Swing type Non-return valve PN 1.0 of size 80 mm dia. DJB Item code 4.14.3Make: Kirloskar/IVC/ DJB Approved.
Supply of CIDF Non rising spindle sluice valve PN 1.0 of size 80 mm dia. DJB Item code 4.22.2Make: Kirloskar/IVC/ DJB Approved.
Supply of PVC Insulated single core un-armoured Flexible Copper Cable of size 25 Sq.mm. Make : Grandley / Gloster/Havells/DJB approved
Providing & fixing of Bourdon pressure Gauge of suitable size in delivery line of Pump set..
Fixing of new pump in the system by bolting in MS base frame in RCC foundation, coupling with Existing motor including minor civil work required for leveling of pump-motor with suction and delivery line. Installation/fixing of sluice Valves, NRVs, etc and making All electrical connections of motor with suitable size lugs, nut bolt & washer etc as per site requirement.
Providing of suitable size MS Gap piece, flange, Suitable size reducer, nut bolts, rubber packing etc and Making suction &delivery connections with pump set with the help of suitable size MS Gap piece, flange, Suitable size reducer, nut bolts, rubber packing etc as per site Requirement by using Gas cutter, welding set, manual labour
Testing the complete system on no load and on full load as per the complete satisfaction of the Engineer –in-charge.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .