| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹31.9 L+₹50,044 (1.59%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹33.6 L+₹2.2 L (7.16%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹35.1 L+₹3.8 L (12.0%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | Rejected-Technical | - | Rejected-Technical REJECTED BEING ADVERSE REMARKS IN WLR |
| Sl No | Description | Qty | Unit | Mohd Rafiq and Co L2 | SHARMA TRADERS L3 | M/S KALSI ENGINEERS AND CONTRACTORS L4 | narayan construction L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | SCHEDULE-A PART-I (B/R WORKS) Taking down cement plaster on brick wall including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. | 990 | Sqm | 5 ₹4,950 Lowest | 12 ₹11,880 | 10 ₹9,900 | 10 ₹9,900 |
| 2.00 | M & L for Rendering 10mm thick on fair faces of brick work in cement mortar 1:6 finishing even and smooth without using extra cement upto any height, work to be carried out in patches complete all as specified and directed. | 390 | Sqm | 150 ₹58,500 Lowest | 150 ₹58,500 Lowest | 150 ₹58,500 Lowest | 200 ₹78,000 |
| 3.00 | M & L for Rendering 15mm thick on fair faces of brick surface in cement mortar 1:4 finished even and smooth without using extra cement, upto any height from GL, work to be carried out in patches complete all as specified and directed. | 390 | Sqm | 150 ₹58,500 Lowest | 150 ₹58,500 Lowest | 150 ₹58,500 Lowest | 200 ₹78,000 |
| 4.00 | M & L for Rendering 10mm thick in CM 1:3 as in ceilings or concrete surfaces such as chajjas, upward facia, downward facias and similar items finished even and smooth including dubbing coat without using extra cement complete all as specified and directed. | 60 | Sqm | 180 ₹10,800 | 150 ₹9,000 Lowest | 150 ₹9,000 Lowest | 200 ₹12,000 |
| 5.00 | M & L for Preparation of newly plastered surfaces of ceilling,upward facias etc and applying three coats of white wash complete all as specified and directed. | 60 | Sqm | 55 ₹3,300 | 7 ₹420 Lowest | 12 ₹720 | 10 ₹600 |
| 6.00 | M & L for Preparation of newly plastered surfaces of wall and applying two coats of Oil bound distemper over one coat of primer complete all as specified and directed. | 390 | Sqm | 40 ₹15,600 Lowest | 42 ₹16,380 | 70 ₹27,300 | 45 ₹17,550 |
| 7.00 | M&L for preparing the Plastered surfaces of walls and applying two coat of Cement base paint over one coat of chalk whiting complete all as specified and directed. | 390 | Sqm | 5 ₹1,950 Lowest | 25 ₹9,750 | 40 ₹15,600 | 35 ₹13,650 |
| 8.00 | Demolition of trellis work (Jafri), including taking as under of battens intrellis (posts and rails measured separately) complete all as specified and directed. | 245 | Sqm | 5 ₹1,225 Lowest | 12 ₹2,940 | 20 ₹4,900 | 5 ₹1,225 Lowest |
| 9.00 | Demolition of Brickwork or stone/boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. | 14 | Cum | 5 ₹70 Lowest | 4,000 ₹56,000 | 4,500 ₹63,000 | 100 ₹1,400 |
| 10.00 | Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed | 5 | Cum | 4,000 ₹20,000 | 52 ₹260 Lowest | 200 ₹1,000 | 100 ₹500 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
31 Jul 2025, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
PERIODICAL SERVICES REPAIRS TO DRAINS COMPOUNDWALL PATHWAYS REPAIR AND DESILTING CLEANING OF MANHOLES SEPTIC TANKS AND MAINTENANCE OF INTERNAL WIRING AT STN HQ REASI AND MINOR UNITS IN SILA GRN UNDER AGE REASI OF GE NAGROTA
2025_MES_718229_1
CANO GEN-55/2025-2026
Open Tender
Civil Works
Item Rate
180 days
GE NAGROTA
Class D Cat a(i) b (i)
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹1 L
Yes
9 Oct 2025
3 Jul 2025
7 Aug 2025
3 Jul 2025
31 Jul 2025
17 Jul 2025
Amount
SCHEDULE-A PART-I (B/R WORKS) Taking down cement plaster on brick wall including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
M & L for Rendering 10mm thick on fair faces of brick work in cement mortar 1:6 finishing even and smooth without using extra cement upto any height, work to be carried out in patches complete all as specified and directed.
M & L for Rendering 15mm thick on fair faces of brick surface in cement mortar 1:4 finished even and smooth without using extra cement, upto any height from GL, work to be carried out in patches complete all as specified and directed.
M & L for Rendering 10mm thick in CM 1:3 as in ceilings or concrete surfaces such as chajjas, upward facia, downward facias and similar items finished even and smooth including dubbing coat without using extra cement complete all as specified and directed.
M & L for Preparation of newly plastered surfaces of ceilling,upward facias etc and applying three coats of white wash complete all as specified and directed.
M & L for Preparation of newly plastered surfaces of wall and applying two coats of Oil bound distemper over one coat of primer complete all as specified and directed.
M&L for preparing the Plastered surfaces of walls and applying two coat of Cement base paint over one coat of chalk whiting complete all as specified and directed.
Demolition of trellis work (Jafri), including taking as under of battens intrellis (posts and rails measured separately) complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed
M& L for RCC 1:2:4 Type B-1 as in 20 mm graded stone aggregate) Columns, pillars, piers, posts and struts complete all as specified and directed.
M & L for Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide for fair finished surfaces complete all as specified and directed.
M& L for RCC ( 1:2:4 Type B-1 using 20 mm graded stone aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M & L for Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide complete all as specified and directed.
M & L TMT steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and direceted
M & L TMT steel bars 5 mm dia and over upto and including 10mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and direceted
M & L Brickwork with subclass ‘B’ bricks,well burnt straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
M & L for Brickwork with subclass ‘B’ bricks,well burnt straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L PCC 1:3:6 Type-C 1 using 20 mm graded as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for water roughs and the like including weathering, slightly rounded or hamfered angles and throating, including formwork complete all as specified and directed.
M & L for Rendering 15 mm thick on brick work or concrete surfaces in cement mortar 1:4 with water proofing compound finished fair and smooth complete all as specified and as directed. Note: water proofing compound shall be measured seprately.
Supply only liquid water proofing compound complete all as specified and directed.
Material & Labour for priming new surface of wall with alkali resistant priming coat and applying two coats of cement base paint complete all as specified and directed.
Demolition of Plain cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L 100mm thick Cement concrete type 1:4:8 type D-2(using 40 mm graded stone aggregate) as in floors including necessary formwork etc complete all as specified and directed.
M&L coloured rubberised Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and no pigmentcomplete all as specified and directed.
Supply only Fine aggregate (sand) for laying to floor finishes complete all as specified and directed.
M&L for 15 mm thick screed bed in cement mortar 1:6 for laying floor finishes. complete all as specified and directed.
M&L coloured chequered cement concrete tiles 20cmX20cmx25mm thick with white cement & pigments set jointed and pointed in neat cement slurry in floors complete all as specified and directed.
M&L Random rubble stone masonry uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
M & L for Rendering 15 mm thick on other than fair faces of walls of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth complete all as specified and as directed.
M & L 20 mm thick rendering in cement mortar 1:4 over stone wall suface finished even and smooth without using extra cement complete all as specified and as directed.
M & L for Preparing new plastered or unplastered surfaces and applying three coats of white wash on walls complete all as specified and as directed.
M & L for Extra for forming fair faces (finished drain of channel 30 cm inner grith in cement concrete using extra cement including forms moulds mitred stopped end etc complete, all as specified and directed.
M & L for Cleaning/clearing of sewage line (including manholes except 1st manhole) 150mm to 250mm bore of any description under ground any depth, removing any type of blockage including desilting, descaling and de-chocking from drain with combined high pressure water jetting cum suction (vacuum) type machine mounted on LMV/HMV having facility of high pressure vacuum including provision of hydraulic application through high pressure thermoplastic fiber based water jetting hose and through conical round shaped nozzle pipe and flushing after cleaning including clearing of manhole, sludge water shall be disposed of directed including taking of manhole cover and re-fixing the same after cleaning complete all as specified and directed.
M & L for Cleaning/clearing of sewage line (including manholes except 1st manhole) 100mm to 150mm bore of any description under ground any depth, removing any type of blockage including desilting, descaling and de-chocking from drain with combined high pressure water jetting cum suction (vacuum) type machine mounted on LMV/HMV having facility of high pressure vacuum including provision of hydraulic application through high pressure thermoplastic fiber based water jetting hose and through conical round shaped nozzle pipe and flushing after cleaning including clearing of manhole, sludge water shall be disposed of directed including taking of manhole cover and re-fixing the same after cleaning complete all as specified and directed.
M & L for Desludging the solid sludge from septic tank, soakage well including inlet/outlet chamber, removing out all scum, silt reduce sludge (both organic/inorganic nature) after plugging the incoming sewage line through combined high pressure water jetting cum suction (vacuum) type machine mounted on LMV/HMV and facility of high pressure vacuum and removing and dumping off the same in the tank to a place out side cantonment at the place marked for the purpose by local municipality or area controlling authority complete all as specified and directed.
M & l for Cleaning of blockage of any type of wc (Indian/pedestal) from WC pan to Ist manhole in single storied bldg including resetting/ refitting of asccess door in soil pipe where opened without causing any damage to the wc pan 'P' or 'S' trap and pipe including fitting complete all as specified and directed.
M & L for Cleaning/clearing of IWC/ EWC, gully trap /floor trap including CI pipe / PVC pipe upto first manhole by roding, taking out all residue including waste and testing by pouring water after cleaning etc complete all as specified and directed by Engr-in-Charge. (Note: Cleaning of PVC/CI pipe from first floor / ground floor embedded in floor or fixed to wall included in this item) complete all as specified and directed.
Taking up or down steel tubing and connection for 15mm tubing complete all as specified and directed.
Taking up or down steel tubing and connection for 20 mm tubing.complete all as specified and directed.
S&F GI tubing 15mm bore medium grade with all fittings fixed to wall, ceiling / floor complete all as specified and directed.
S&F GI tubing 20 mm bore medium grade with all fittings fixed to wall, ceiling / floor complete all as specified and directed.
Cleaning of service RCC/Ferro/PVC service/over head tank cleaning process as under (a) Dewatering using submerssible pump/bailing out of water to dispose the minimum level of dirty water from the tank. (b) Cleaning the tank/ UG sump bottom, walls and ceiling using high pressure water jet to dislodge the algae calcinations, dirt etc. (c) Disposing the dirt water sludge etc., using specially designed sludge removal pump. (d) Cleaning the tank inside throughly by using industrial grade vaccum pump to make the tank inside free from dirt, algea and sludge etc. (e) Treating the inside walls, bottom, ceiling of tank including all nooks and corners by using and spraying anti bacterial agent such as hydrogenperoxide (bio degradable) for disinfection of tank inside. (f) Total disinfection and sterlisation of tank hyginecally cleaned and bacteria free and safeby Eco-Friendly for storage of water. Note :- Incl cleaning of outlet pipe upto stop cock/gate valve by removing and refixing the same and making the line serviceable after cleaning & Qty of tank are consider for cleaning twice in a Year and Date of cleaning to be written over head tank after cleaning.
(a) For exc 250 ltrs and not exc 500 ltrs capacity
(b) For exc 501 ltrs and not exc 1000 ltrs capacity
(c) For exc 1001 lt and not exc 2000 lt capacty
(d) For exc 2001 lt and not exc 5000 lt capacty
S & F Rotational moulded polyethylene water 500 ltr Capacity storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I incl Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe 20mm bore . (Minimum weight 2 0 m m - 2 1 0 g m s).Including taking down existing water tank and float valve. complete all as specified and directed.
S & F Rotational moulded polyethylene water 1000 ltr Capacity storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I incl Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe 20mm bore . (Minimum weight 2 0 m m - 2 1 0 g m s).Including taking down existing water tank and float valve. complete all as specified and directed.
Supply & Fixed in repairs brass float valves high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed to iron pipe of bore 20mm bore complete all as specified and directed.
Supply & Fixed in repairs brass float valves high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed to iron pipe of bore 15mm complete all as specified and directed.
S & F PVC (SWR) branch bends any radius 110mm bore of pipe in repairs. complete all as specified and directed.
S & F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or floors in repairs complete all as specified and directed.
S&L in repair 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F as in repair Vitreous China Squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rests complete all as specified and directed.
Supply & fixed PVC flushing cistern low level of capacity of 10 ltr, white, valve less symphonic action type complete with inlet ball valve float and handle or Push button type including brackets and fixed in repair complete all as specified & directed.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
Excavation in trenches in soft/ loose soil exc 1.5 m deep and getting out including forming bottom to required level or slop for laying pipe, concrete bed manhole etc n.exc 10 Sqm on plan complete all as specified and directed.
Returning filling in soft/ loose soil including spreading levelling ,watering and well ramming in layers not exc 25 mm thick complete all as specified and directed.
Removing of excavated surplas materials to a distance exc 50 m but nexc 100 mm and depositing where directed a level n.exc 1.5 mtrs above the starting point complete all as specified and directed.
Demolition or breaking up 150 mm internal dia drain pipe including fittings of any desciption in any position and removing rubbish upto a distance of n. exc 50 mtr complete all as specified and directed.
M&L for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 for 150 mm bore of pipe complete all as specified and directed.
M&L Reinforced concrete pipes, class NP3, laid and jointed complete with collars 150 mm bore laid in trenches and jointed with CM 1:1 complete all as specified complete all as specified and directed.
M&L for brick work built in CM 1:4 with sub class 'B' bricks straight or curved on plan exc 6 m mean radius complete all as specified and directed.
M&L for precast RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in manhole cover slab with plain fair faces and set in CM 1:4 all as specified
M& L Excavating in post holes (or similar holes)in hard dense soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm all as specified and as directed
M&L PCC 1:4:8 Type D2( using 40mm graded crushed stone agg) , as in fdn filling and mass concrete.
S& F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including two coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces all as specified and directed.
Preparation of old decorated surface of wall including brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil, greasy spots and applying One coat of Oil Bound Distemper on wall complete all as specified and directed.
M & L for Preparation of old decorated surface of wall including brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil, greasy spots and applying two coat of Oil Bound Distemper on wall complete all as specified and directed.
M &L 3mm thick wall care putty on wall complete all as specified and directed.
M & L for Preparation of old decorated surface including brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil, greasy spots and applying two coat of cement base paint on wall complete all as specified and directed.
M & L for Preparation of old decorated surface including brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil, greasy spots and applying one coat of cement base paint on wall complete all as specified and directed.
M & L for Complete removal of existing treatment and applying one coat of apex exterior quality over a coat of primer complete all as specified and directed.
M & L for Preparing Old steel painted surface to receive painting, including washing and cleaning, etc. over 10cm in width or girth, not otherwise described & applying one coats of synthetic enamel paint in any pattern complete all as specified and directed by Engineer in charge.
M & L for Preparing old surface or unplastered surfaces and applying two coats of white wash on walls complete all as specified and as directed.
M & L for Preparing Old wood and wood based surface to receive painting, including washing and cleaning, etc. over 10cm in width or girth, not otherwise described & applying one coat of synthetic enamel paint complete all as specified and directed.
SCHEDULE-A PART-II (E/M WORKS) Taking down carefully surface aluminium or copper point wiring with PVC casing-caping or conduit (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, regulators, sockets, light fittings etc and making good disturbed surfaces complete all as specified and directed.
M&L for point wiring with PVC insulated sheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium grade ISI marked not less than 20 mm dia ,concealed in wall and surface on ceiling with all conduit fittings & fixing acessories inculding sunken anodised pressed terminal box not less than 1.2 mm thick covered with 3 mm thick bakelite laminated sheet cover of suitable size with suitable size screws for mounting switches, sockets, regulators with and including 1.5 sqmm FRLS multi stranded copper conductor drawing as continuous earth wire connected to main earth and earth dolly for One light/fan point /bell point controlled by one switch switches/sockets/regulators complete all as specified & directed.
All as per Srl item N0 75 above but for one socket out let 5 Amp controlled by one switch on same board with other switch complete all as spd & directed
All as per Srl item N0 75 above for one socket out let 5 Amp controlled by one switch on independent board with other switch complete all as spd & directed
M&L for point wiring in repair with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including PVC casing-caping not less than 32x16 mm ISI marked ivory colour with all conduit fittings / fixing accessories and unwelded sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets for one 16 amp socket outlet point controlled by one switch on independent board.
S&F angle holder,in repair insulated polycabonate body with back plate complete all as specified and directed.
S&F in switch piano flush button single pole one way 6 amp complete all as specified and directed.
S&F in switch piano flush button single pole one way 16 amp complete all as specified and directed.
S&F in socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete all as specified and directed.
S&F in socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete all as specified and directed.
S&F in Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed.
S&F in Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal complete all as specified and directed.
S&F in Plug Top of socket outlet 6 amp complete all as specified and directed.
S&F in Plug Top of socket outlet 16 amp complete all as specified and directed.
S&F in Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp box type complete universal complete all as specified and directed.
S&F in Switch socket combination 2 in 1, 3 pin, 5 Amp box type complete universal complete all as specified and directed.
S & F in Modular switch 5/6 Amps suitable for 1 Module complete all as specified and directed.
S & F in Modular socket 5 pin 5/6 Amps suitable for 2 Module complete all as specified and directed.
S & F in Modular switch 15/16 Amps suitable for 1 Module complete all as specified and directed.
S & F in Modular socket 5/6 pin 15/16 Amps suitable for 2 Module complete all as specified and directed.
S & F in Modular Fan step Regulator electronic, 120 watts 2 Module complete all as specified and directed.
S&F in ceiling rose 3 plates polycarbonate body complete all as specified and directed.
S&Fin hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete all as specified and directed.
S&F in bell push, flush type, 6 amp 240 volts complete all as specified and directed..
S&F in door bell, AC, 240 volts, single pole complete all as specified and directed.
M&L in replacement of sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sq mm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked minimum 20 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sq mm as earth continuity conductor connected to commen earth and earth dolly complete including taking down existing UNSV.complete all as specified and directed
M&L in replacement of sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sq mm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked minimum 25 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 sq mm as earth continuity conductor connected to commen earth and earth dolly complete including taking down existing UNSV.complete all as specified and directed
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion complete all as specified & directed.
S&F in repair MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with following ratings & ways:-
SPN, in 240 volts, 4 ways.
SPN, in 240 volts, 8 ways.
SPN, in 240 volts, 12 ways.
TPN, in 415 volts, 4 ways.
S&F in repair MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:-
Single pole 6 to 32 amp.
Single pole 40 to 63 amp.
Double pole 10 to 32 amp.
Double pole, 40 to 63 amp.
Four pole 40 to 63 amp.
S&F in repair LED tube light batten (1.2 m) made of CRCA sheet housing with a PC glossy difusser and mounting accessories duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not more than 22 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete all as specified and directed.
All as pr Item No 104 here in before but for LED tube light batten warm type (Yellow Lumen) complete all as specified and directed.
S&F in repair LED tube light batten (2 Fit ) made of CRCA sheet housing with a PC glossy difusser and mounting accessories duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not more than 10 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete all as specified and directed.
S&F in LED (bulb) fixture 18 watt including connection complete all as specified and directed.
S&F in LED (bulb) fixture 12 watt including connection complete all as specified and directed.
S&F in LED (bulb) fixture 10/9 watt including connection complete all as specified and directed.
S&F in LED bulkhead fitting 9 watt IP 66 & IK 09 with pressure diecast aluminum housing & polycarbonate diffuser duly prewired connection with 0.75 sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable complete all as specified and directed.
S&F in energy efficient recessed mounted LED luminaire suitable for 2'x2' , 36 watt 230 V 50 Hz, grid ceiling with flat diffuser and lumen output of 3300 lumens having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable in renewal of any type luminaire as required complete all as specified and directed.
All as pr Item No 111 here in before but for LED luminaire warm type (Yellow Lumen) complete all as specified and directed.
Taking down unsv ceiling fans 1200/1400 mm sweep 230 v, AC supply, single phase from site, depositing in MES store yard, dismantling all parts, checking serviceability of all parts & continuity of copper winding, (Burn out winding Fan should be staking aside for rewinding), including cleaning all the components of fan, oiling , greesing, including reolacement of rusted /unsv nuts. bolts split Pin rubber reel machine screws, shaft, capacitor, clamps, etc as required complete all as specified and directed.
Taking down unsv Exhaust Fan 200/230/300 mm sweep 230 v, AC supply, single phase from site, depositing in MES store yard, dismantling all parts, checking serviceability of all parts & continuity of copper winding, (Burn out winding Fan should be staking aside for rewinding), including cleaning all the components of fan, oiling , greesing, including replacement of rusted lunsv nuts. bolts split Din rubber Dad . machine screws. shaft, caoacitor, clamos. etc complete all as specified and directed.
Taking out, burnt winding wire from ceiling fans (Which required rewinging, Obtained from item No.01) motor of 1200/1400 mm sweep 230 v, AC supply, single phase, Transporting to contractor workshop for rewinding the same with super enameled copper winding wire of existing gauge/turns & size, thoroughly cleaning all the components complete all as specified and directed.
Taking out, burnt winding wire from Exhaust fans (Which required rewinging, Obtained from item No.02) motor of 300 mm sweep 230 v, AC supply, single phase, Transporting to contractor workshop for rewinding the same with super enameled copper winding wire of existing gauge/turns & size, thoroughly cleaning all the components of fan, oiling ,complete all as specified and directed.
All as per Sri Item No-116 here-in-above but for exhaust fan of size 400/450 mm of any make complete all as specified and directed.
S&f in replacement ball bearing of ceiling / exhaust fan of any size and make as required with alignment of shaft and testing complete all as specified and directed.
S& F in replacement of AC film capacitor 4.0 mfd, 440 volts suitable for any type ceiling fan/exhaust fan in FR plastic casing including connection complete all as specified and directed.
S& F in replacemen of AC film capacitor 2.5 mfd, 440 volts suitable for any type ceiling fan in FR plastic casing including connection complete all as specified and directed.
S & F in Replacement of old unserviceable fan blades made of MS sheet duly powder coated ,of type make and colour as of ceiling fan suitable for 1200mm sweep ceiling fan of any make incl all accessories complete all as specified and directed.
S & F in Replacement of Blade assembly of Exhaust fan with fixing hexagonal nut of size 300 to 450mm of any make. complete all as specified and directed.complete all as specified and directed.
S & F in Replacement of iron Frame of exhaust fan 4 way with welded and painted complete all as specified and directed.
MIL Gun metal bush of exhaust fancomplete all as specified and directed.
S&f in replacement of rubber reel with a pair of clamp, nuts, bolts, split pins etc suitable for ceiling fan down rods of anv size and make as required complete all as specified and directed.
S&F in replacementl of PVC canopy suitable for ceiling fan of any size and make as required.complete all as specified and directed.
S&F in replacement of PVC insulated and sheathed flexible 3 core cable with copper conductor of size 0.5 sqmm complete all as specified and directed.
S&F in replacement of down rod of ceiling fan made of Gl pipe medium grade 15 mm bore of length upto 600 mm including cutting. threading. painting etc complete all as specified and directed.
Taking down of desert cooler fixed at any position, cleaning internally and externally by scraping all scales dirt etc and repairs to desert cooler to check leakage, tightening ( By replacing screws, nuts and bolts etc) including painting of desert cooler with spray machine with two coats of synthetic enamel hammer tone paint over one coat of red oxide primer, letters, Refixing of the desert cooler after necessary oilling and greasing of fan and water lifting pump complete all as specified and directed.
Supplying in replacement Fan motor 1/6 HP, 230 volt, single phase for the existing desert cooler complete all soecified and directed
Supplying in replacement Water lifting pump, Vertical type, 18 watts, 230 volt, 50 C/S, single phase suitable for desert coolers complete all specified and directed
Supplying in replacement Side panel made out of 1.0 mm thick Gl sheet, fixed with iron handle suitable for desert coolers of capacity 3000 cfm including two coats of synthetic enamel hammer tone paint over a one coat of red oxide primer on both side of Dane! complete all specified and directed
Supplying in replacement High density polythene pipe 15 mm dia complete all specified and directed
Supplying in replacement Complete steel body of desert cooler of capacity 3000 cfm duly painted with two coats of synthetic enamel hammer tone paint over one coat of red oxide primer. The body of desert cooler shall be fabricated as under ( a ) The top and bottom made out of 1.25 mm thick Gl sheet. ( b ) side panels (set of three) made out 1.00 mm thick Gl sheet. ( c) Front Grill of suitable size and of approved quality.
Supplying and Replacement Three-way water distributor, heavy duty, PVC, including necessary nuts and bolts complete and taking out old distributor complete all specified and directed
Supplying in replacement of capacitor 4 mfd suitable for Desert cooler complete all as specified and directed
Re-wiring of desert cooler with suitable size of copper conductor PVC insulated cable and providing main lead three metre long of 3 core PVC insulated copper conductor of size 23/ .0076 complete all specified and directed
Dismantling and taking out Old, Unserviceable fan motor from the desert cooler and rewinding with supper enamel copper winding wire of suitable size, varnishing etc including replacement of bushes, assembling testing and refixing at the existing site complete all as specified and directed
M& L for fabrication of desert cooler stand made out of MS angle iron 40x40x6mm thick all as per existing size suitable at site incl painting ith two coats of synthetic enamelled paint over a coat of red oxide primer coat replacement complete all as specified and directed.
Repairs to voltage stabilizer of any make, single phase with input voltage 135 - 190 V and output voltage 200-240 volt, capacity 5 KVA by dismantling and taking out burnt main transformer and rewinding with super enamelled copper wire of suitable size including varnishing and insulation material etc. Complete all as specified and directed
All as per item No- 141 here in before but for capacity 03 KVA
All as per item No- 141 here in before but for capacity 01 to 02 KVA
Disconnecting the inlet and outlet connections of the existing Geyser 25/50 Ltr, taking down carefully, cleaning/descaling the blocks both in Gl pipes and water heater refixing the bolts by proper grouting in the wall and refixing the water heater in the same or in other places as directed by Engr in charge
S&F in place of unsv PVC connection of any make with (ISI Mark) having10mm dia, 45 cm long with steel reinforcement suitable for hot & cold-water geyser outlet supply with 02 Nos of Unions/ cup shaped cover with washers all as directed by Engr-in-charge.
Replacement of unserviceable heating element of geyser 2KW/1.5 KW of any pattencomplete all as specified and directed.
Replacement of unserviceable thermostat of geyser 2KW/1.5 KW of any patten complete all as specified and directed.
S & F in replacement of pressure release valve suitable for 25/50 ltr electric water heater complete all as specified and directed.
S&F in replacement of U/S apparatus plate of geysers 25/50 litre capacities by brazing not exceeding 5 mm thick complete all as specified and directed.
Replacement of unserviceable Inner Tank of geyser steel body of capacity 25/50 Ltrs as existing patten complete all as specified and directed.
Replacement of unserviceable PVC flexible pipe inlet 16mm outer dia and 450 mm long for hot/cold water heavy duty with brass nuts & bolts. complete all as specified and directed.
Disconnecting the inlet and outlet connections of the existing solar water heater 300 Ltr, taking down carefully, cleaning/descaling the blocks both in Gl pipes and water heater refixing the bolts by proper grouting in the wall and Refixing the water heater in the same or in other places as directed by Engr in charge.
Replacement of unserviceable- heating element of solar water heater 300 Ltr 2KW/1.5 KW of any patten complete all as specified and directed.
Replacement of unserviceable thermostat of Solar water heater 300 ltr 2KW/1.5 KW of any patten complete all as specified and directed.
Replacement of unserviceable appratus plate of Solar water heater 300 ltr capacity by brazing not exeeding 5 mm thick complete all as specified and directed.
Mohd Rafiq and Co (BID ID -3370252)
SHARMA TRADERS (BID ID -3376197)
M/S KALSI ENGINEERS AND CONTRACTORS (BID ID -3378548)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .